PubMed Health⌕ Search

Biomedical subjects

Dobrin Nedelkov

Publications and source records attributed to Dobrin Nedelkov.

26 records · Page 2Linked to original sources

Novel mass spectrometric immunoassays for the rapid structural characterization of plasma apolipoproteins.

Novel mass spectrometric immunoassays (MSIAs) for the isolation and structural characterization of plasma apolipoprotein A-I (apoA-I), apoA-II, and apoE have been developed. The assays combine selective isolation of apolipoprotein species via affinity capture with mass-specific detection using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. In application, plasma (from 50 microl of whole blood drawn from individuals, using finger lancet) was addressed with affinity pipette tips derivatized with antibodies toward the specific apolipoprotein. The time required for each assay was approximately 15 min, less if assays on multiple individuals were performed in parallel. In a brief study of five individuals, several recently reported apoA-II variants were identified and observed consistently in all individuals. Additionally, the apoE phenotype of E3/E3 was observed in three of the individuals, and E2/E3 and E3/E4 observed in the remaining two individuals, the latter of whom suffers from Alzheimer's disease. Overall, the MSIA approach offers a rapid, sensitive, and highly accurate means of profiling apolipoproteins from small volumes of plasma.

Adult↗

Comparative phenotypic analyses of human plasma and urinary retinol binding protein using mass spectrometric immunoassay.

Mass spectrometric immunoassay (MSIA) is a proteomics technology that combines the selectivity of affinity capture with the sensitivity and resolution of mass spectrometric detection. This unique approach allows for intact protein identification therefore is readily capable of discriminating between protein variants, i.e., mutations, posttranslational modifications, and truncations. In this work, MSIA is used in the comparative analyses of retinol binding protein (RBP) from the plasma and urine of a small study population. Detailed RBP profiles were obtained from both biological fluids, resulting in the identification of several catabolic RBP products (present in urine) that have not been previously reported. In addition, comparative analysis of urine samples taken from healthy and renally impaired individuals revealed different breakdown profiles. These results illustrate the use of MSIA for the rapid, sensitive, and accurate profiling of RBP both within and between individuals.

Adult↗

High-throughput protein characterization using mass spectrometric immunoassay.

A high-throughput mass spectrometric immunoassay system for the analysis of proteins directly from plasma is reported. A 96-well format robotic workstation was used to prepare antibody-derivatized affinity pipette tips for subsequent use in the extraction of specific proteins from plasma and deposition onto 96-well format matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) targets. Samples from multiple individuals were screened with regard to the plasma protein transthyretin (TTR), followed by analysis of the same plasma samples for the transthyretin-associated transport protein, retinol-binding protein (RBP). Analyses were able to detect the presence of posttranslationally modified TTR and RBP, as well as a mutation present in the TTR of one individual. Subsequent analyses of wild-type and mutated TTR using enzymatically active MALDI-TOF MS targets were able to identify the site and nature of the point mutation. The approach represents a rapid (approximately 100 samples/2 h, reagent preparation-to-data) and accurate means of characterizing specific proteins present in large numbers of individuals for proteomic and clinical/diagnostic purposes.

Antibody Affinity↗

Design of buffer exchange surfaces and sensor chips for biosensor chip mass spectrometry.

The feasibility of buffer exchange in biosensor chip mass spectrometry, along with the construction of base sensor chips and use of alternative chip chemistries, is demonstrated in this work. Beta-2-microglobulin (beta2m) was used as an analyte and captured in the first flow cell (FC1) on the sensor chip surface by an immobilized anti-beta2m antibody. Low pH buffer was then used to elute the captured analyte from the flow cell and route it to a second flow cell (FC2) downstream that served as a cation exchanger that retains the analyte. Following additional washes in FC1, the analyte present in FC2 was either eluted with a higher pH buffer (to demonstrate the possibility of elution into a downstream trypsin flow cell), or it was subjected to matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) mass spectrometry analysis to verify its presence in FC2. In a separate experiment, a gold-sputtered glass slide (base chip) was activated through a formation of 11-mercaptoundecanoic acid self-assembled monolayer and via reaction with 1,1"-carbonyldiimidazole. The activated chip was placed manually into the biosensor and two surfaces (flow cells) were derivatized with antibodies to beta2m and cystatin C (cysC). To evaluate the chip performance, diluted human urine aliquot was injected over the flow cells. Following the surface plasmon resonance analysis, the chip was MALDI-TOF MS analyzed, yielding signals from beta2m and cysC from their respective flow cells. Artifacts arising from the surface chemistries were not observed in the analysis.

Buffers↗

Delineating protein-protein interactions via biomolecular interaction analysis-mass spectrometry.

The utility of biomolecular interaction analysis-mass spectrometry (BIA/MS) in screening for protein-protein interactions was explored in this work. Experiments were performed in which proteins served as ligands for screening of possible interactions with other proteins from human plasma and urine. The proteins utilized were beta-2-microglobulin, cystatin C (cysC), retinol binding protein (RBP), transthyretin (TTR), alpha-1-microglobulin, C-reactive protein, transferrin and papain. The immobilization of functionally active proteins was confirmed via interactions with antibodies to the corresponding proteins. Various dilutions of human urine and plasma were injected over the protein-derivatized surfaces. It was observed that the urine injections generally yielded smaller SPR responses than those observed after the plasma injections. The BIA/MS experiments did not reveal novel protein-protein interactions, although several established interactions (such as those between RBP and TTR, and cysC and papain) were validated. Few protein ligand deficiencies (such as truncations) leading to false negative and false positive BIA/MS results were also discovered.

Humans↗

Design and use of multi-affinity surfaces in biomolecular interaction analysis-mass spectrometry (BIA/MS): a step toward the design of SPR/MS arrays.

The feasibility of multi-affinity ligand surfaces in biomolecular interaction analysis-mass spectrometry (BIA/MS) was explored in this work. Multi-protein affinity surfaces were constructed by utilizing antibodies to beta-2-microglobulin, cystatin C, retinol binding protein, transthyretin, serum amyloid P and C-reactive protein. In the initial experiments, all six antibodies were immobilized on a single site (flow cell) on the sensor chip surface, followed by verification of the surface activity via separate injections of purified proteins. After an injection of diluted human plasma aliquot over the antibodies-derivatized surfaces, and subsequent MALDI-TOF MS analysis, signals representing five out of the six targeted proteins were observed in the mass spectra. Further, to avoid the complexity of the spectra, the six proteins were divided into two groups (according to their molecular weight) and immobilized on two separate surfaces on a single sensor chip, followed by an injection of human plasma aliquot. The resulting mass spectra showed signals from all proteins. Also, the convolution resulting from the multiply charged ion species was eliminated. The ability to create such multi-affinity surfaces indicates that smaller-size ligand areas/spots can be employed in the BIA/MS protein interaction screening experiments, and opens up the possibilities for construction of novel multi-arrayed SPR-MS platforms and methods for high-throughput parallel protein interaction investigations.

Biosensing Techniques↗

Comparative urine protein phenotyping using mass spectrometric immunoassay.

Reported here, human urine samples were analyzed for beta-2-microglobulin (beta2m), transthyretin (TTR), cystatin C, urine protein 1 (UP1), retinol binding protein (RBP), albumin, transferrin, and human neutrophil defensin peptides (HNP) using mass spectrometric immunoassay (MSIA). MSIA is a unique analytical technique, which allows for the generation of distinct protein profiles of specific target proteins from each subject, which may be subsequently used in comparative protein expression profiling between all subjects. Comparative profiling allows for the rapid identification of variations within individual protein expression profiles. Although the majority of analyses performed in this study revealed homology between study participants, roughly one-quarter showed variation in the protein profiles. Some of these observed variants included a point mutation in TTR, absence of wild-type RBP, monomeric forms UP1, a novel beta2m glycated end product and altered HNP ratios. MSIA has been previously used in the analysis of blood proteins, but this study shows how MSIA easily transitions to the analysis, of urine samples. This study displays how qualitative urine protein differentiation is readily achievable with MSIA and is useful in identifying proteomic differences between subjects that might be otherwise overlooked with other analytical techniques due to complexity of the resulting data or insufficient sensitivity.

DNA Mutational Analysis↗

Quantitative mass spectrometric immunoassay of insulin like growth factor 1.

Reported in this work are the development of mass spectrometric immunoassay (MSIA) devices and methods for the qualitative analysis of IGF-1 and -2, and the rigorous quantification of IGF-1 from human plasma. A method involving addition of SDS in moderate concentration to unfractionated plasma for disrupting IGF/IGFBP complexes was initially developed. The method is suitable for the direct extraction of the IGFs and subsequent mass spectrometric analysis. Rat plasma, containing IGF-1 that is mass shifted from human IGF-1, was used as an internal reference standard (IRS) for the quantification of IGF-1 directly from human plasma. A standard curve with linear dynamic range of at least 2 orders of magnitude was constructed from serially diluted IGF-1 standards containing equal amounts of rat plasma. Using the standard curve, IGF-1 levels in plasma samples from eight individuals were determined. The limit of detection for the IGF-1 MSIA was also evaluated and established to be approximately 15 pM. The assay is rapid and can be performed in parallel via high-throughput robotics processing. Furthermore, the mass spectrometry aspect of the developed IGF-1 immunoassay offers a new dimension in the ongoing study of IGF-1 and related diseases.

Animals↗