PubMed Health⌕ Search

Biomedical subjects

Dolores J Cahill

Publications and source records attributed to Dolores J Cahill.

18 recordsLinked to original sources

Profiling humoral autoimmune repertoire of dilated cardiomyopathy (DCM) patients and development of a disease-associated protein chip.

Dilated cardiomyopathy (DCM) is a myocardial disease characterized by progressive depression of myocardial contractile function and ventricular dilatation. Thirty percent of DCM patients belong to the inherited genetic form; the rest may be idiopathic, viral, autoimmune, or immune-mediated associated with a viral infection. Disturbances in humoral and cellular immunity have been described in cases of myocarditis and DCM. A number of autoantibodies against cardiac cell proteins have been identified in DCM. In this study, we have profiled the autoantibody repertoire of plasma from DCM patients against a human protein array consisting of 37,200 redundant, recombinant human proteins and performed qualitative and quantitative validation of these putative autoantigens on protein microarrays to identify novel putative DCM specific autoantigens. In addition to analyzing the whole IgG autoantibody repertoire, we have also analyzed the IgG3 antibody repertoire in the plasma samples to study the characteristics of IgG3 subclass antibodies. By combining screening of a protein expression library with protein microarray technology, we have detected 26 proteins identified by the IgG antibody repertoire and 6 proteins bound by the IgG3 subclass. Several of these autoantibodies found in plasma of DCM patients, such as the autoantibody against the Kv channel-interacting protein, are associated with heart failure.

Amino Acid Sequence↗

High throughput identification of potential Arabidopsis mitogen-activated protein kinases substrates.

Mitogen-activated protein kinase (MAPK) cascades are universal and highly conserved signal transduction modules in eucaryotes, including plants. These protein phosphorylation cascades link extracellular stimuli to a wide range of cellular responses. However, the underlying mechanisms are so far unknown as information about phosphorylation substrates of plant MAPKs is lacking. In this study we addressed the challenging task of identifying potential substrates for Arabidopsis thaliana mitogen-activated protein kinases MPK3 and MPK6, which are activated by many environmental stress factors. For this purpose, we developed a novel protein microarray-based proteomic method allowing high throughput study of protein phosphorylation. We generated protein microarrays including 1,690 Arabidopsis proteins, which were obtained from the expression of an almost nonredundant uniclone set derived from an inflorescence meristem cDNA expression library. Microarrays were incubated with MAPKs in the presence of radioactive ATP. Using a threshold-based quantification method to evaluate the microarray results, we were able to identify 48 potential substrates of MPK3 and 39 of MPK6. 26 of them are common for both kinases. One of the identified MPK6 substrates, 1-aminocyclopropane-1-carboxylic acid synthase-6, was just recently shown as the first plant MAPK substrate in vivo, demonstrating the potential of our method to identify substrates with physiological relevance. Furthermore we revealed transcription factors, transcription regulators, splicing factors, receptors, histones, and others as candidate substrates indicating that regulation in response to MAPK signaling is very complex and not restricted to the transcriptional level. Nearly all of the 48 potential MPK3 substrates were confirmed by other in vitro methods. As a whole, our approach makes it possible to shortlist candidate substrates of mitogen-activated protein kinases as well as those of other protein kinases for further analysis. Follow-up in vivo experiments are essential to evaluate their physiological relevance.

Arabidopsis↗

Profiling of alopecia areata autoantigens based on protein microarray technology.

Protein biochips have a great potential in future parallel processing of complex samples as a research tool and in diagnostics. For the generation of protein biochips, highly automated technologies have been developed for cDNA expression library production, high throughput protein expression, large scale analysis of proteins, and protein microarray generation. Using this technology, we present here a strategy to identify potential autoantigens involved in the pathogenesis of alopecia areata, an often chronic disease leading to the rapid loss of scalp hair. Only little is known about the putative autoantigen(s) involved in this process. By combining protein microarray technology with the use of large cDNA expression libraries, we profiled the autoantibody repertoire of sera from alopecia areata patients against a human protein array consisting of 37,200 redundant, recombinant human proteins. The data sets obtained from incubations with patient sera were compared with control sera from clinically healthy persons and to background incubations with anti-human IgG antibodies. From these results, a smaller protein subset was generated and subjected to qualitative and quantitative validation on highly sensitive protein microarrays to identify novel alopecia areata-associated autoantigens. Eight autoantigens were identified by protein chip technology and were successfully confirmed by Western blot analysis. These autoantigens were arrayed on protein microarrays to generate a disease-associated protein chip. To confirm the specificity of the results obtained, sera from patients with psoriasis or hand and foot eczema as well as skin allergy were additionally examined on the disease-associated protein chip. By using alopecia areata as a model for an autoimmune disease, our investigations show that the protein microarray technology has potential for the identification and evaluation of autoantigens as well as in diagnosis such as to differentiate alopecia areata from other skin diseases.

Adult↗

Protein biochips: A new and versatile platform technology for molecular medicine.

The human genome has been sequenced and the challenges of understanding the function of the newly discovered genes have been addressed. High-throughput technologies such as DNA microarrays have been developed for the profiling of gene expression patterns in whole organisms or tissues. Protein arrays are emerging to follow DNA chips as possible screening tools. Here, we review the generation and application of microarray technology to obtain more information on the regulation of proteins, their biochemical functions and their potential interaction partners. Already, a large variety of assays based on antibody-antigen interactions exists. In addition, the medical relevance of protein arrays will be discussed.

Animals↗

Bacterial protein microarrays for identification of new potential diagnostic markers for Neisseria meningitidis infections.

Neisseria meningitidis is the most common cause of meningitis and causes epidemic outbreaks. One trait of N. meningitidis, which is associated with most of the currently recognized virulence determinants, is the presence of phase-variable genes that are suspected to enhance its ability to cause an invasive disease. To detect the immune responses to phase-variable expressed proteins, we applied protein microarray technology for the screening of meningitis patient sera. We amplified all 102 known phase-variable genes from N. meningitidis serogroup B strain MC58 by polymerase chain reaction and subcloned them for expression in Escherichia coli. With this approach, we were able to express and purify 67 recombinant proteins representing 66% of the annotated genes. These were spotted robotically onto coated glass slides to generate protein microarrays, which were screened using 20 sera of patients suffering from meningitis, as well as healthy controls. From these screening experiments, 47 proteins emerged as immunogenic, exhibiting a variable degree of seroreactivity with some of the patient sera. Nine proteins elicited an immune response in more than three patients, with one of them, the phase-variable opacity protein OpaV (NMB0442), showing responses in 11 patient sera. This is the first time that protein microarray technology has been applied for the investigation of genetic phase variation in pathogens. The identification of disease-specific proteins is a significant target in biomedical research, as such proteins may have medical, diagnostic, and commercial potential as disease markers.

Bacterial Proteins↗

Mouse protein arrays from a TH1 cell cDNA library for antibody screening and serum profiling.

The mouse is the premier genetic model organism for the study of disease and development. We describe the establishment of a mouse T helper cell type 1 (T(H)1) protein expression library that provides direct access to thousands of recombinant mouse proteins, in particular those associated with immune responses. The advantage of a system based on the combination of large cDNA expression libraries with microarray technology is the direct connection of the DNA sequence information from a particular clone to its recombinant, expressed protein. We have generated a mouse T(H)1 expression cDNA library and used protein arrays of this library to characterize the specificity and cross-reactivity of antibodies. Additionally, we have profiled the autoantibody repertoire in serum of a mouse model for systemic lupus erythematosus on these protein arrays and validated the putative autoantigens on highly sensitive protein microarrays.

Animals↗

Seeing better through a MIST: evaluation of monoclonal recombinant antibody fragments on microarrays.

Automation is the key approach for genomewide and proteomewide screening of function and interaction. Especially for proteomics, antibody microarrays are a useful tool for massive parallel profiling of complex samples. To meet the requirements of antibody microarrays and to obtain a great variety of antibodies, new technologies such as phage display have partly replaced the classical hybridoma method. While the selection process for phage-displayed antibody fragments itself has been automated, the bottleneck was shifted further downstream to the identification of monoclonal binders obtained from the selections. Here, we present a new approach to reduce time, material, and waste to extend automation beyond the selection process by application of conventional microarray machinery. We were able to express recombinant antibody fragments in a single inoculation and expression step and subjected them without purification directly to an automated high-throughput screening procedure based on the multiple spotting technique (MIST). While obtaining comparable sensitivities to enzyme-linked immunosorbent assays, we minimized manual interaction steps and streamlined the technique to be accessible within the automated selection procedure.

Antibodies, Monoclonal↗

ICln, a novel integrin alphaIIbbeta3-associated protein, functionally regulates platelet activation.

A critical role for the conserved alpha-integrin cytoplasmic motif, KVGFFKR, is recognized in the regulation of activation of the platelet integrin alpha(IIb)beta(3). To understand the molecular mechanisms of this regulation, we sought to determine the nature of the protein interactions with this cytoplasmic motif. We used a tagged synthetic peptide, biotin-KVGFFKR, to probe a high density protein expression array (37,200 recombinant human proteins) for high affinity interactions. A number of potential integrin-binding proteins were identified. One such protein, a chloride channel regulatory protein, ICln, was characterized further because its affinity for the integrin peptide was highest as was its expression in platelets. We verified the presence of ICln in human platelets by PCR, Western blots, immunohistochemistry, and its co-association with alpha(IIb)beta(3) by surface plasmon resonance. The affinity of this interaction was 82.2 +/- 24.4 nm in a cell free assay. ICln co-immunoprecipitates with alpha(IIb)beta(3) in platelet lysates demonstrating that this interaction is physiologically relevant. Furthermore, immobilized KVGFFKR peptides, but not control KAAAAAR peptides, specifically extract ICln from platelet lysates. Acyclovir (100 microm to 5 mm), a pharmacological inhibitor of the ICln chloride channel, specifically inhibits integrin activation (PAC-1 expression) and platelet aggregation without affecting CD62 P expression confirming a specific role for ICln in integrin activation. In parallel, a cell-permeable peptide corresponding to the potential integrin-recognition domain on ICln (AKFEEE, 10-100 microm) also inhibits platelet function. Thus, we have identified, verified, and characterized a novel functional interaction between the platelet integrin and ICln, in the platelet membrane.

15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5↗

Cell-free protein expression and functional assay in nanowell chip format.

The expression and characterization of large protein libraries requires high-throughput tools for rapid and cost-effective expression and screening. A promising tool to meet these requirements is miniaturized high-density plates in chip format, consisting of an array of wells with submicroliter volumes. Here, we show the combination of nanowell chip technology and cell-free transcription and translation of proteins. Using piezoelectric dispensers, we transferred proteins into nanowells down to volumes of 100 nL and successfully detected fluorescence using confocal laser scanning. Moreover, we showed cell-free expression of proteins on a nanoliter scale using commercially available coupled transcription and translation systems. To reduce costs, we demonstrated the feasibility of diluting the coupled in vitro transcription and translation mix prior to expression. Additionally, we present an enzymatic inhibition assay in nanowells to anticipate further applications, such as the high-throughput screening of drug candidates or the identification of novel enzymes for biotechnology.

Cell-Free System↗

Characterization of the proteins released from activated platelets leads to localization of novel platelet proteins in human atherosclerotic lesions.

Proteins secreted by activated platelets can adhere to the vessel wall and promote the development of atherosclerosis and thrombosis. Despite this biologic significance, however, the complement of proteins comprising the platelet releasate is largely unknown. Using a proteomics approach, we have identified more than 300 proteins released by human platelets following thrombin activation. Many of the proteins identified were not previously attributed to platelets, including secretogranin III, a potential monocyte chemoattractant precursor; cyclophilin A, a vascular smooth muscle cell growth factor; calumenin, an inhibitor of the vitamin K epoxide reductase-warfarin interaction, as well as proteins of unknown function that map to expressed sequence tags. Secretogranin III, cyclophilin A, and calumenin were confirmed to localize in platelets and to be released upon activation. Furthermore, while absent in normal vasculature, they were identified in human atherosclerotic lesions. Therefore, these and other proteins released from platelets may contribute to atherosclerosis and to the thrombosis that complicates the disease. Moreover, as soluble extracellular proteins, they may prove suitable as novel therapeutic targets.

Arteriosclerosis↗

A nonredundant human protein chip for antibody screening and serum profiling.

There is burgeoning interest in protein microarrays, but a source of thousands of nonredundant, purified proteins was not previously available. Here we show a glass chip containing 2413 nonredundant purified human fusion proteins on a polymer surface, where densities up to 1600 proteins/cm(2) on a microscope slide can be realized. In addition, the polymer coating of the glass slide enables screening of protein interactions under nondenaturing conditions. Such screenings require only 200-microl sample volumes, illustrating their potential for high-throughput applications. Here we demonstrate two applications: the characterization of antibody binding, specificity, and cross-reactivity; and profiling the antibody repertoire in body fluids, such as serum from patients with autoimmune diseases. For the first application, we have incubated these protein chips with anti-RGSHis(6), anti-GAPDH, and anti-HSP90beta antibodies. In an initial proof of principle study for the second application, we have screened serum from alopecia and arthritis patients. With analysis of large sample numbers, identification of disease-associated proteins to generate novel diagnostic markers may be possible.

Alopecia↗

3D protein microarrays: performing multiplex immunoassays on a single chip.

The enzyme-linked immunosorbent assay (ELISA) is typically applied in the format of microtiter plates. To increase throughput and reduce consumption of precious samples, efforts have been made to transfer ELISA to the microchip format using conventional microarrays, microfluidic systems, and chips bearing microwells. However, all three formats lack the possibility to screen several analytes on several immobilized binders at a time or require complicated liquid handling, surface modifications, and additional equipment. Here, we describe an immunoassay performed on a standard microscope slide without the requirement for wells or tubes to separate the samples using standard surfaces and machinery already available for microarray technology. The new multiple spotting technique (MIST) comprises immobilization of a binder onto a surface and subsequent spotting of the second compound on the same spot, on top of the immobilized binder. We show that the analytes bind their ligands immediately within the confined space of separate droplets on the chip surface, thereby eliminating the need for extra incubation time. We illustrate the feasibility of the new technique by spotting dilution rows of proteins or monoclonal and polyclonal antibodies on top of their immobilized binders. Moreover, we demonstrate specificity by applying a mixture of antibodies in a multiplex format and demonstrate that the technique is compatible with conventional microarray protocols, such as total incubation. Finally, we indicate that the technique is capable of quantifying as little as 400 zmol (240,000 molecules) of analyte.

Antibodies↗

Next generation of protein microarray support materials: evaluation for protein and antibody microarray applications.

The performance of protein and antibody microarrays is dependent on various factors, one of which is the use of an appropriate microarray surface for the immobilisation of either protein or antibody samples. We have investigated the properties of seven new surfaces in the context of both protein and antibody microarray technology. We have demonstrated the functionality of all new slide coatings and investigated the mean signal to spotted concentration ratio, determined detection limits and calculated coefficients of variation. Moreover, new concepts for slide coatings such as dendrimer and poly(ethylene glycol)-epoxy slides were evaluated and improved qualities of novel slide surfaces were observed. Optimal slide coatings for antibody and protein chips were proposed and the requirements for both technologies were discussed.

Antibodies↗

Protein arrays and their role in proteomics.

Arraying technologies have shown the way to smaller sample volumes, more efficient analyses and higher throughput. Proteomics is a field, which has grown in significance in the last five years. This review outlines recent developments in protein arrays and their applications in proteomics, and discusses the requirements, current limitations and the potential and future perspectives of the technology.

Gene Expression Regulation↗

Toward optimized antibody microarrays: a comparison of current microarray support materials.

With the advent of protein and antibody microarray technology several different coatings and protocols have been published, which may be broadly divided into two types: gel-coated surfaces and plain non-gel-coated glass or plastic surfaces, some with chemical groups attached. We have screened 11 different array surfaces of both types and compared them with respect to their detection limit, inter- and intrachip variation, and storage characteristics. Five different antibodies were immobilized onto each type of microarray support, with total protein concentrations ranging from 40 fmol to 25 amol per spot. From these results, it was seen that some antibodies were more suited for use on antibody arrays. All measurements were performed in quadruplicate, and the results revealed high signal uniformity and reproducibility of most plain glass and plastic slides. Lower detection limits were obtained with polyacrylamide-coated slides, making them more suitable for the detection of very low concentrations of antigen. All microarray coatings could be stored for a period of 8 weeks; however, improved results were seen after 2 weeks of storage. In conclusion, the results indicate the need to test each antibody to be used on an antibody array and to select the microarray coating based on experimental requirements.

Acrylic Resins↗

The impact of protein biochips and microarrays on the drug development process.

With the genome sequences of several organisms now in public databases, the scientific community has realized that it is time to prepare for the next step: the understanding of biological systems or systems biology. Whereas genes contain the information for life, the encoded proteins and RNAs fulfill nearly all the functions, from replication to regulation. At present, there is a perceived demand for high-throughput and parallel analytical devices as research tools in systems biology, and, in addition, for new concepts to extract knowledge and value from these data. Protein biochips will play a decisive role in meeting this need in the future.

Drug Evaluation, Preclinical↗

Generation of minimal protein identifiers of proteins from two-dimensional gels and recombinant proteins.

We describe the technical feasibility and methodology to characterize a protein by a minimal set of structural information generated by matrix assisted laser desorption/ionization (MALDI)-mass spectrometry, termed a "minimal protein Identifier" (MPI). MPIs can be determined for proteins from two-dimensional gels and recombinant proteins and can be used to compare and identify proteins from these sources.

Brain↗