Publications and source records attributed to Dominik Morhard.

2 recordsLinked to original sources

Material differentiation by dual energy CT: initial experience.

The aim of this study was to assess the feasibility of a differentiation of iodine from other materials and of different body tissues using dual energy CT. Ten patients were scanned on a SOMATOM Definition Dual Source CT (DSCT; Siemens, Forchheim, Germany) system in dual energy mode at tube voltages of 140 and 80 kVp and a ratio of 1:3 between tube currents. Weighted CT Dose Index ranged between 7 and 8 mGy, remaining markedly below reference dose values for the respective body regions. Image post-processing with three-material decomposition was applied to differentiate iodine or collagen from other tissue. The results showed that a differentiation and depiction of contrast material distribution is possible in the brain, the lung, the liver and the kidneys with or without the underlying tissue of the organ. In angiographies, bone structures can be removed from the dataset to ease the evaluation of the vessels. The differentiation of collagen makes it possible to depict tendons and ligaments. Dual energy CT offers a more specific tissue characterization in CT and can improve the assessment of vascular disease. Further studies are required to draw conclusions on the diagnostic value of the individual applications.

Algorithms↗

Introducing a freely accessible internet database for identification of cerebral aneurysm clips to determine magnetic resonance imaging compatibility.

OBJECTIVE: Knowledge of the magnetic properties of cerebral aneurysm clips in patients undergoing magnetic resonance imaging (MRI) is imperative. In daily practice, however, it is often impossible to derive this information from previous medical records. The aim of this study was to develop a freely accessible internet database to identify unknown cerebral aneurysm clips on the basis of conventional x-ray images of the cranium and to provide reliable information about their magnetic properties to allow safe MRI investigations in these patients. METHODS: The 17 most commonly used clip series of the past 50 years were selected. The ferromagnetic properties of 47 example clips were examined by means of the Food and Drug Administration-approved "deflection angle test." An HTML-based database has been developed using standard x-ray images in two planes and photographs of the clips. Furthermore, details about alloy, ferromagnetic properties, MRI compatibility, year of construction, and other characteristics identifiable on x-rays were included. RESULTS: Seven aneurysm clips (of four clip models) were judged to be not MRI-compatible. The database named "ClipFinder" allows easy identification of cerebral aneurysm clips on standard cranial x-rays by comparing the films with the databank images supported by information on unique features of the clip design. CONCLUSION: On exemplary applications, ClipFinder provides a fast and easy-to-use database to identify unknown cerebral aneurysm clips via the internet and determine their MRI compatibility. The reliability of the identification system needs to be further evaluated in clinical practice before it can be recommended for widespread use.

Contraindications↗