PubMed Health⌕ Search

Biomedical subjects

Dominique Ploin

Publications and source records attributed to Dominique Ploin.

4 recordsLinked to original sources

Risk factors for piperacillin/tazobactam-resistant Escherichia coli in ICU patients: a clinical study.

OBJECTIVE: To determine risk factors of infections with piperacillin/tazobactam-resistant Escherichia coli in critical care patients. DESIGN: Prospective, consecutive sample survey study. SETTING: Surgical intensive care unit (ICU) in a university hospital. PATIENTS: A consecutive series of 133 patients from whom culture results were positive for E. coli during their ICU stay. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Multivariate logistic regression analysis identified the following significant independent factors associated with the emergence of a piperacillin/tazobactam-resistant Escherichia coli: prior use of amoxicillin (odds ratio, 4.15) and amoxicillin/clavulanate (odds ratio, 3.25). CONCLUSIONS: Treatment with amoxicillin or amoxicillin/clavulanate is a major risk factor for the detection of piperacillin/tazobactam-resistant E. coli in ICU patients.

Anti-Bacterial Agents↗

Influenza burden in children newborn to eleven months of age in a pediatric emergency department during the peak of an influenza epidemic.

BACKGROUND: The aim of this study was to determine the burden of influenza-related diseases in children 0 to 11 months of age during the peak of the 2001 to 2002 influenza epidemic. METHODS: This was a prospective study at the Pediatric Emergency Department of Edouard Herriot tertiary teaching hospital in Lyon, France. The study included 304 infants 0 to 11 months of age. Consecutive patients were systematically enrolled during the 4 weeks of the influenza epidemic peak (Weeks 3 to 6, 2002). Influenza viruses were detected by antigen detection and virus culture from nasal swabs. Structured telephone interviews were conducted on Days 8 and 15 after virus detection. There was also a 6-month survey into the medicoadministrative database to detect late complications that required delayed hospitalization of influenza-positive children. RESULTS: Influenza virus was detected in 99 (33%) of 304 patients (A/H3N2 in 30% and B in 3%). Nonrespiratory symptoms were the dominant clinical manifestations in 30% of influenza-positive children. One child with influenza presented with febrile seizures. Twenty (20%) children with influenza were hospitalized. Parents reported recovery from the illness in 63 and 94% of children on Days 8 and 15, respectively. The median length of an influenza episode was 8 days. CONCLUSIONS: Our results confirm the high prevalence of influenza-related morbidity in infants during the epidemic peak. One child in three consulting to the pediatric emergency room had a virologically confirmed influenza infection regardless of the body temperature. Every fifth child with influenza was admitted to hospital, which corresponds to an admission rate of 237 per 100 000 children 0 to 11 months of age.

Age Factors↗

Clinical evaluation of a self blood pressure monitor according to the First International Consensus Conference on Self Blood Pressure Measurement.

BACKGROUND: The Calor TensioSense Bras automatic blood pressure monitor has obtained European Union certification, but the clinical validity of this new oscillometric device when handled by lay subjects has yet to be evaluated. DESIGN: The design employed prospective and blinded blood pressure measurements and a validation procedure according to the criteria set out by the First International Consensus Conference on Self Blood Pressure Measurement (1999). METHODS: Thirty-three subjects were recruited, 11 in each of three strata of systolic blood pressure (<130, 130-160 and >160 mmHg). Blood pressure was measured sequentially seven times, alternating observer and lay measurements. Two certified observers used two mercury columns and a double stethoscope; the subjects used the automatic device. All blood pressure readings and recordings were blinded. Adequate cuff sizes were used, and the subjects' position was standardized. Discrepancy analysis between manual and automatic measurements was carried out using VAPA software. RESULTS: Dispersion of the discrepancies between manual and automatic measurements showed no specific trend. Out of the 99 systolic blood pressure measurements, 53, 76 and 89 discrepancies were less than 5, 10 and 15 mmHg, respectively. Of the 99 diastolic blood pressure measurements, 62, 86 and 97 discrepancies were less than 5, 10 and 15 mmHg, respectively. The mean inter-observer discrepancy was 1 mmHg for both systolic and diastolic blood pressure comparisons. CONCLUSION: This evaluation showed that this device complies with the international validation protocol requirements. Thus, the device can, providing adequate instruction is given in the clinic, be recommended for self-measurement by patients at home, as well as for clinical or epidemiological research.

Blood Pressure Determination↗