PubMed Health⌕ Search

Biomedical subjects

Donald A Severyn

Publications and source records attributed to Donald A Severyn.

4 recordsLinked to original sources

Usefulness of angle corrected tissue Doppler to assess segmental left ventricular function during dobutamine stress echocardiography in patients with and without coronary artery disease.

The application of angle correction to tissue Doppler (TD) during dobutamine stress echocardiography (DSE) extends the application of TD to all left ventricular segments, improves the differentiation of abnormal from normal segmental responses to stress, and has promise to improve its clinical utility for objectively evaluating wall motion during DSE.

Adult↗

The influence of hemodynamics and wall biomechanics on the thrombogenicity of vein segments perfused in vitro.

This study addresses the hypothesis that exposure to peripheral arterial (ART) or coronary (COR) hemodynamics and wall biomechanics affect platelet deposition on vein segments. Intact human saphenous vein (HSV) and porcine internal jugular vein (PIJV) segments were studied under venous (VEN), ART, and COR environments using in vitro perfusion systems. Wall shear stress (tau) and circumferential wall stress (sigma(theta)) were calculated for PIJV segments. Platelet deposition was measured using a radioactive assay. PIJV ART segments exhibited a 14% increase in inner diameter over time (P < 0.05). tau, acting on PIJV ART specimens, was less at 6 h compared with time 0 (P < 0.05). sigma(theta) was lower in the VEN specimens compared with ART and COR groups (P < 0.01). Platelet deposition decreased by 40% on PIJV ART segments (P < 0.05) but increased 3.2-fold on PIJV COR segments (P < 0.05) versus VEN control segments. Platelet deposition was increased 1.75-fold in COR HSV cases versus VEN segments. These data indicate that short-term exposure to COR conditions lead to enhanced platelet deposition, whereas ART conditions decrease platelet deposition.

Animals↗

Regional correlation by color-coded tissue Doppler to quantify improvements in mechanical left ventricular synchrony after biventricular pacing therapy.

Cardiac resynchronization therapy (CRT) can improve cardiac function in patients with heart failure and left bundle branch block. To test a new synchrony index derived from mitral annular velocity by color tissue Doppler, 19 subjects were studied: 9 patients with heart failure and left bundle branch block at baseline and at 1, 3 and 6 months after CRT and 10 normal controls. The synchrony index in patients with heart failure was less than that in controls at baseline (r = 0.60 +/- 0.13 vs 0.94 +/- 0.02; p <0.01), but improved at 6 months after CRT (r = 0.77 +/- 0.09; p <0.05 vs baseline).

Aged↗

Second-generation tissue Doppler with angle-corrected color-coded wall displacement for quantitative assessment of regional left ventricular function.

To test the hypothesis that a new tissue Doppler (TD) approach using angle-correction and transformation of velocity data to color-coded displacement data may objectively quantify regional left ventricular function, in vitro experiments were first performed with an oscillating echo target precisely controlled by a microstepping motor. Displacement varied from 1 to 15 mm (60 to 130 cycles/min) at angles of 0 degrees and 45 degrees to the echo transducer. Custom software transformed TD data to displacement data. Sixty-five subjects were then studied: 35 with wall motion abnormalities and 30 normal controls. Results were compared with independent visual assessment and caliper measurements of endocardial excursion from gray-scale images. In vitro displacement imaging strongly correlated with true displacement (r = 0.99, p <0.0001). In humans, peak transmural displacement discriminated normal results (6.3 +/- 3.2 mm) from hypokinesia (2.7 +/- 1.8 mm, p <0.05), akinesia (0.4 +/- 1.2 mm, p <0.05) from hypokinesia, and dyskinesia (-1.9 +/- 1.2 mm, p <0.05) from akinesia. Normal subendocardial displacement was 5.9 +/- 2.9 versus 4.0 +/- 3.9 mm in the epicardial layer (p <0.01). This displacement gradient was absent in abnormal segments. Displacement data correlated with endocardial excursion by calipers (parasternal views: r = 0.86, all views: r = 0.79, both p <0.0001). Overall accuracy of displacement imaging was 82% (kappa = 0.71) versus 66% (kappa = 0.43) for visual assessment with caliper data as the standard of reference. Angle-corrected displacement imaging was superior to routine visual assessment and is a promising new method to quantify regional left ventricular function.

Aged↗