PubMed Health⌕ Search

Biomedical subjects

Donald E Brooks

Publications and source records attributed to Donald E Brooks.

9 recordsLinked to original sources

The influence of grafted polymer architecture and fluid hydrodynamics on protein separation by entropic interaction chromatography.

Entropic interaction chromatography (EIC) provides efficient size-based separation of protein mixtures through the entropy change associated with solute partitioning into a layer of hydrophilic homopolymer that has been end-grafted within the pores of a macroporous chromatography support. In this work, surface-initiated atom-transfer radical polymerization (ATRP) is used to prepare a library of EIC stationary phases covering a wide range of grafted-chain densities and molecular weights. Exhaustive chain cleavage and analysis by saponification and GPC-MALLS, respectively, show that the new ATRP synthesis procedure allows for excellent control over graft molecular weight and polydispersity. The method is used to prepare high-density grafts (up to 0.164 +/- 0.005 chains/nm(2)) that extend the range of EIC applications to include efficient buffer-exchange and desalting of protein preparations. Reducing the graft density allows for greater partitioning of high molecular weight solutes, extending the linear range of the selectivity curve. Increasing graft molecular weight also alters selectivity, but more directly affects column capacity by increasing the volume of the grafted layer. Protein partitioning in high-density EIC columns is found to decrease with mobile-phase velocity (u). Although solute mass transfer resistances leading to an increase in plate height can explain this effect, pressure drop data across the column are indicative of weak convective flow through at least a fraction of the grafted architecture. Modeling of the grafted brush properties in the presence of solvent flow by subjecting a self-consistent-field theory representation of the brush to a viscous shear force predicts that the grafted chains will tilt and elongate in the direction of flow. The shear force may therefore act to reduce the number of conformations available to chains, increasing their rigidity without significantly altering the thickness of the grafted layer. A reduction in protein partitioning is then predicted when the dependence on u of the solute entropy loss is stronger than that of the grafted polymer, a condition met at high graft densities.

Chromatography, Gel↗

Blood compatibility of novel water soluble hyperbranched polyglycerol-based multivalent cationic polymers and their interaction with DNA.

A novel class of hyperbranched polymers based on polyglycerol (PG) and poly(ethylene glycol) (PEG) are synthesized by multibranching anionic ring opening polymerization. Multivalent cationic sites are added to these polymers by a post-amination and quarternization reactions. Blood compatibility studies using these polymers at different concentrations showed insignificant effects on complement activation, platelet activation, coagulation, erythrocyte aggregation and hemolysis compared to branched cationic polyethyleneimine (PEI). The degree of quarternization does not have large influence on the blood compatibility of the new polymers. Cytotoxicity of these polymers is significantly lower than that of PEI and is a function of quarternized nitrogen present in the polymer. Also, these polymers bind DNA in the nanomolar range and are able to condense DNA to highly compact, stable, water soluble nanoparticles in the range of 60-80 nm. Gel electrophoresis studies showed that they form electroneutral complexes with DNA around N/P ratio 1 irrespective of the percentage of quarternization under the conditions studied.

Biocompatible Materials↗

Biocompatibility testing of branched and linear polyglycidol.

Polyglycidols are flexible hydrophilic polyethers that are potentially biocompatible polymers based on their similarities to the well-studied poly(ethyleneglycol). Polyglycidols can be prepared as branched or linear polymers by suitable synthetic methods. Biocompatibility testing of these polymers conducted in vitro as well as in vivo are reported here. The in vitro studies included hemocompatibility testing for effects on coagulation (PT and APTT), complement activation, red blood cell aggregation, and whole blood viscosity measurements. In vitro cytotoxicity experiments were also conducted. The results were compared with some of the common biocompatible polymers already in human use. Results from these studies show that polyglycidols are highly biocompatible. Hyperbranched polyglycidols were found to be well tolerated by mice even when injected in high doses.

Animals↗

Entropic interaction chromatography: separating proteins on the basis of size using end-grafted polymer brushes.

Partitioning of a macromolecule into the interfacial volume occupied by a grafted polymer brush decreases the configurational entropy (DeltaSbrush(c)) of the terminally attached linear polymer chains due to a loss of free volume. Self-consistent field theory (SCF) calculations are used to show that DeltaSbrush(c) is a strong function of both the size (MWp) of the partitioning macromolecule and the depth of penetration into the brush volume. We further demonstrate that the strong dependence of DeltaSbrush(c) on MWp provides a novel and powerful platform, which we call entropic interaction chromatography (EIC), for efficiently separating mixtures of proteins on the basis of size. Two EIC columns, differing primarily in polymer grafting density, were prepared by growing a brush of poly(methoxyethyl acrylamide) chains on the surface of a wide-pore (1,000-A pores, 64-microm diameter rigid beads) resin (Toyopearl AF-650M) bearing surface aldehyde groups. Semipreparative 0.1-L columns packed with either EIC resin provide reduced-plate heights of 2 or less for efficient separation of globular protein mixtures over at least three molecular-weight decades. Protein partitioning within these wide-pore EIC columns is shown to be effectively modeled as a thermodynamically controlled process, allowing partition coefficients (K(P)) and elution chromatograms to be accurately predicted using a column model that combines SCF calculation of K(P) values with an equilibrium-dispersion type model of solute transport through the column. This model is used to explore the dependence of column separation efficiency on brush properties, predicting that optimal separation of proteins over a broad MWp range is achieved at low to moderate grafting densities and intermediate chain lengths.

Acrylamides↗

Evaluation of an atomic force microscopy pull-off method for measuring molecular weight and polydispersity of polymer brushes: effect of grafting density.

The accuracy of the molecular weights Mn and polydispersities of polymer brushes, determined by stretching the grafted chains using atomic force microscopy (AFM) and measuring the contour length distribution, was evaluated as a function of grafting density sigma. Poly(N,N-dimethylacrylamide) brushes were prepared by surface initiated atom transfer radical polymerization on latex particles with sigma ranging between 0.17 and 0.0059 chains/nm2 and constant Mn. The polymer, which could be cleaved from the grafting surface by hydrolysis and characterized by gel permeation chromatography (GPC), had a Mn of 30,600 and polydispersity (PDI) of 1.35. The Mn determined by the AFM technique for the higher density brushes agreed quite well with the GPC results but was significantly underestimated for the lower sigma. At high grafting density in good solvent, the extended structure of the brush increases the probability of forming segment-tip contacts located at the chain end. When the distance between chains approached twice the radius of gyration of the polymer, the transition from brush to mushroom structure presumably enabled the formation of a larger number of segment-tip contacts having separations smaller than the contour length, which explains the discrepancy between the two methods at low sigma. The PDI was typically higher than that obtained by GPC, suggesting that sampling of chains with above average contour length occurs at a frequency that is greater than their spatial distribution.

Journal Article↗

Molecular weight and polydispersity estimation of adsorbing polymer brushes by atomic force microscopy.

We have estimated the molecular weight, Mn, and polydispersity, PDI, of densely grafted poly(N-isopropylacrylamide) (PNIPAM) brushes using a novel atomic force microscopy (AFM) approach. When compression of a polymer brush induced adsorption of multiple chains to an AFM tip, the resulting decompression force profile exhibited a maximum attractive force at a separation, Lm, that decayed to zero with increasing tip-sample separation. We have found that the separation Lm approximates the average contour length, Lc, determined by gel permeation chromatography (GPC). The detection of a decaying attractive force at separations larger than Lc suggests that chains of above average length sequentially break free from the tip as they are stretched away from the grafting surface. The shape of the decompression profile in this region approximately paralleled the cumulative weight fraction of the grafted chains determined by GPC. The fraction of chains of a given molecular weight determined from a single force curve fit a log-normal distribution, having a standard deviation that provided an estimate of the PDI. We have characterized two PNIPAM brushes by this AFM technique as well as by GPC coupled to a multiangle laser light-scattering detector (MALLS). The values obtained by AFM-(1) Mn,AFM = (3.8+/-0.5) x 10(4), PDI,(AFM) = 1.3+/-0.1 and (2) Mn,AFM = (9.4+/-1.4) x 10(4), PDI,(AFM) = 1.3+/-0.1-agreed quite well with the corresponding GPC/MALLS values of (1) Mn,GPC = 4.77 x 10(4), PDI,GPC = 1.33 and (2) Mn,GPC = 9.49 x 10(4), PDI = 1.35. This technique requires only a single force curve to obtain a statistical distribution of contour lengths and provides a novel method for estimating the Mn and PDI of appropriate uniformly grafted dense polymer layers.

Acrylic Resins↗

Attractive bridging interactions in dense polymer brushes in good solvent measured by atomic force microscopy.

Using an atomic force microscope (AFM), we have investigated the interaction forces exerted by latex particles bearing densely grafted polymer brushes consisting of poly(N,N-dimethylacrylamide) (PDMA), poly(methoxyethylacrylamide) (PMEA), poly(N-isopropylacrylamide) (PNIPAM), and PMEA-b-PNIPAM in aqueous media (good solvent). The brushes were prepared by controlled surface-initiated atom transfer radical polymerization, and the hydrodynamic thicknesses were measured by dynamic light scattering. The molecular weight (Mn), grafting density (sigma), and polydispersity (PDI) of the brushes were determined by gel permeation chromatography and multiangle laser light scattering after cleaving the polymer from the latex surface by hydrolysis. Force profiles of PDMA (0.017 nm(-2) < or = sigma < or = 0.17 nm-2) and PMEA (sigma = 0.054 nm-2) brushes were purely repulsive upon compression, with forces increasing with Mn and a, as expected, due to excluded volume interactions. At a sufficiently low grafting density (sigma = 0.012 nm-2), PDMA exhibited a long-range exponentially increasing attractive force followed by repulsion upon further compression. The long-range attractive force is believed to be due to bridging between the free chain ends and the AFM tip. The PNIPAM brush exhibited a bridging force at a grafting density of 0.037 nm(-2), a value lower than the sigma needed to induce bridging in the PDMA brush. Bridging was therefore found to depend on grafting density as well as on the nature of the monomer. The grafting densities of these polymers were larger than those typically associated with bridging. Bridging interactions were used to confirm the presence of PNIPAM in a block copolymer PMEA-b-PNIPAMA brush given that the original PMEA homopolymer brush produced a purely repulsive force. The attractive force was first detected in the block copolymer brush at a separation that increased with the length of the PNIPAM block.

Journal Article↗

The glycan-rich outer layer of the cell wall of Mycobacterium tuberculosis acts as an antiphagocytic capsule limiting the association of the bacterium with macrophages.

Mycobacterium tuberculosis, the causative agent of tuberculosis, is a facultative intracellular pathogen that infects macrophages and other host cells. We show that sonication of M. tuberculosis results in the removal of material from the surface capsule-like layer of the bacteria, resulting in an enhanced propensity of the bacteria to bind to macrophages. This effect is observed with disparate murine and human macrophage populations though, interestingly, not with freshly explanted alveolar macrophages. Enhanced binding to macrophages following sonication is significantly greater within members of the M. tuberculosis family (pathogens) than within the Mycobacterium avium complex (opportunistic pathogens) or for Mycobacterium smegmatis (saprophyte). Sonication does not affect the viability or the surface hydrophobicity of M. tuberculosis but does result in changes in surface charge and in the binding of mannose-specific lectins to the bacterial surface. The increased binding of sonicated M. tuberculosis was not mediated through complement receptor 3. These results provide evidence that the surface capsule on members of the M. tuberculosis family may be an important virulence factor involved in the survival of M. tuberculosis in the mammalian host. They also question the view that M. tuberculosis is readily ingested by any macrophage it encounters and support the contention that M. tuberculosis, like many other microbial pathogens, has an antiphagocytic capsule that limits and controls the interaction of the bacterium with macrophages.

Animals↗

Plasma protein adsorption to surfaces grafted with dense homopolymer and copolymer brushes containing poly(N-isopropylacrylamide).

Growing polymer chains from surface initiators in principle allows much more dense polymer surface layers to be created than can be produced by grafting of whole (self-excluding) chains. We have utilized aqueous atom transfer radical polymerization to graft a series of cleavable hydrophilic poly(N-isopropylacrylamide) (PNIPAM) homopolymers and block copolymers of substituted acrylamides from polystyrene latex to give brushes of controlled MW and surface density. Average chain separations much less than their free solution radii of gyration have been achieved. Exposure to radiolabeled single proteins or to whole plasma and subsequent analysis by SDS-PAGE shows that PNIPAM brushes decrease protein adsorption relative to the latex surface or other substituted polyacrylamides. The PNIPAM brushes exhibit a second-order phase transition around 30 degrees C as reflected by a decrease in the hydrodynamic thickness of the brush at higher temperatures. Total plasma protein adsorption is increased at 40 degrees C compared to 20 degrees C but there is significant differential adsorption behavior among the proteins detected by gel-electrophoresis analysis.

Acrylic Resins↗