PubMed Health⌕ Search

Biomedical subjects

Donald H Johnson

Publications and source records attributed to Donald H Johnson.

7 recordsLinked to original sources

Arthroscopic meniscal repair using the BioStinger.

PURPOSE: Biodegradable devices are available for all-inside meniscal repairs. One device, the BioStinger (Linvatec, Largo, FL), is made of molded poly-L-lactic acid. The purpose of this study was to evaluate the effectiveness of and any adverse events associated with meniscus repair using this device. TYPE OF STUDY: Nonrandomized prospective cohort study. METHODS: A prospective, consecutive, 3-center meniscal repair series using BioStingers (group 1), vertical inside-out sutures (group 2), or hybrid repairs combining BioStingers and sutures (group 3) was studied. Lysholm, Tegner, Cincinnati, and IKDC activity scores were obtained and clinical outcomes and adverse events documented. RESULTS: There were 85 patients who underwent 89 meniscus repairs with an average 26.5 months of follow-up. There were 47 BioStinger repairs (group 1), 29 suture repairs (group 2), and 13 hybrid repairs (group 3). The tear length was statistically greater for the hybrid repair group (P < .5). There were 73 repairs associated with anterior cruciate ligament reconstructions and 12 repeat arthroscopies were performed. Meniscal healing failed in 6 knees (4 in group 1, 0 in group 2, and 2 in group 3). The meniscal healing failed in 7% of those associated with anterior cruciate ligament reconstructions. Mean Tegner scores improved from 2.8 to 6.3, the final IKDC activity score was 3.2 out of 4, the mean Lysholm score improved from 51 to 88, and the mean Cincinnati score improved from 44 to 84. Two BioStinger repair cases had joint-line tenderness from device migration confirmed by magnetic resonance imaging. No tenting of the skin or articular cartilage scuffing was observed. CONCLUSIONS: The success rate for the 29 suture repairs was 100% and for the 47 BioStinger repairs was 91%. These preliminary results are consistent with other repair techniques. LEVEL OF EVIDENCE: Level II, Therapeutic Prospective Cohort Study.

Absorbable Implants↗

A review of ski injuries resulting in combined injury to the anterior cruciate ligament and medial collateral ligaments.

Alpine skiing is a global winter recreational sport with 15 million participants in the United States alone, and an overall injury rate of 2.5 per 1,000 ski person-days. Isolated injury to the anterior cruciate ligament (ACL) or the medial collateral ligament (MCL) is common among ski injuries; however, combined injury to these structures is rare. Controversy in the management of ACL instability following alpine ski injury is diminishing with improvements in the techniques of intra-articular cruciate reconstruction. However, the management of the combined ACL-MCL injury remains something of an enigma. Evidence exists to support both surgical and nonsurgical management strategies for the medial structures, but little consensus exists for the timing of the repair. This paper highlights the mechanisms of ski injuries that can result in combined injury to the ACL and MCL. The anatomy and biomechanics of the medial complex as it relates both to stability and operative repair are reviewed, and literature on the techniques and indications used for MCL repair in the setting of a combined injury is presented. On the basis of this review, we believe that an injury to the MCL does not need to be repaired if the ACL is reconstructed after a combined injury.

Anterior Cruciate Ligament↗

Basic science in digital imaging: storage and retrieval.

This practical discussion reviews the current methods available for digital image storage and retrieval. The organization of digital images is important to allow easy retrieval of the data in the future. Examples of several software programs that will catalogue and retrieve the images are demonstrated.

Diagnostic Imaging↗