Normotensive and hypotensive closed-loop resuscitation using 3.0% NaCl to treat multiple hemorrhages in sheep.

OBJECTIVE: NaCl solutions (7.5%) have been reported to be effective for resuscitation in animals and trauma patients, but these solutions are not approved for use in the United States. We hypothesized that infusion of Food and Drug Administration-approved 3% NaCl provides superior cardiovascular and metabolic function while reducing the overall fluid requirement for resuscitation of hemorrhage. Our objective was to compare four groups, hypotensive and normotensive resuscitation of hemorrhage using 3% NaCl (HS) or lactated Ringer's (LR). DESIGN: Sheep were hemorrhaged in three separate bleeds, 25 mL/kg at T0 mins and 5 mL/kg at both T50 and T70 mins. SETTING: University laboratory. SUBJECTS: Instrumented conscious sheep. INTERVENTIONS: Resuscitation was started at T30 mins and continued until T180. Normotensive and hypotensive resuscitation to mean arterial pressures of 90 mm Hg and 65 mm Hg, respectively, was performed with LR or HS using a closed-loop resuscitation system. MEASUREMENTS AND MAIN RESULTS: All four groups were successfully resuscitated to near target levels. Two animals in the hypotensive treatment protocols died during the second and third bleeding, one with the LR65 group and one with the HS65 group. Mean infused volumes were 59.9 +/- 7.0 and 18.0 +/- 5.9 in the LR90 and LR65 groups, respectively, and were 19.6 +/- 2.2 mL/kg and 13.3 +/- 5.7 mL/kg in the HS90 and HS65 treatments (p < .05; LR90 vs. each of the groups). Cardiac indexes were significantly higher with normotensive vs. hypotensive treatment. However, there was no hemodynamic advantage apparent with HS vs. LR when compared with the normotensive or hypotensive treatments. Some animals had high lactate levels (>10 mmol) with both of the hypotensive treatments and also with the HS90 treatment, while not one of the 11 LR90 treatment animals had lactate levels >8 mmol. CONCLUSIONS: Volume sparing was apparent with HS, but no hemodynamic or metabolic advantage was apparent when used for either normotensive or hypotensive resuscitation. Trends toward lower base excess values and higher occurrences of deaths only in the hypotensive treatment protocols suggest that resuscitation to a target mean arterial pressure of 65 mm Hg may be too low.

Animals↗

Optoacoustic monitoring of blood hemoglobin concentration: a pilot clinical study.

The optoacoustic technique is noninvasive, has high spatial resolution, and potentially can be used to measure the total hemoglobin concentration ([THb]) continuously and accurately. We performed in vitro measurements in blood and in vivo tests in healthy volunteers. Our clinical protocol included rapid infusion of intravenous saline to simulate rapid change in the [THb] during fluid therapy or surgery. Optoacoustic measurements were made from the wrist area overlying the radial artery for more than 1 h. The amplitude of the optoacoustic signal generated in the radial artery closely followed the [THb] measured directly in concurrently collected blood samples.

Acoustics↗

Optoacoustic, noninvasive, real-time, continuous monitoring of cerebral blood oxygenation: an in vivo study in sheep.

BACKGROUND: Current, invasive cerebral oxygenation monitors require either retrograde jugular venous bulb cannulation or intraparenchymal probe insertion. There is no accurate, noninvasive, continuous monitor of cerebral blood oxygenation. METHODS: The authors designed, built, and tested novel optoacoustic instrumentation that continuously measures blood oxygenation in the superior sagittal sinus (SSS) in vivo in 12 anesthetized sheep. In this technique, laser pulses generate acoustic signals, the amplitudes and slopes of which are proportional to oxyhemoglobin saturation in the SSS. Optoacoustic signals from the SSS measured through the scalp and cranium were compared with directly measured oxyhemoglobin saturation in blood withdrawn from the cannulated SSS. RESULTS: In the first experiments (feasibility), FIO2 changes produced rapid corresponding changes in optoacoustic signals and arterial oxygen saturation. In the second experiments (validation), the authors correlated oxyhemoglobin saturation in the SSS with optoacoustic signals and developed quantifying algorithms. In eight of nine validation experiments, the authors quantified optoacoustic signals by subtracting the temporal profile at low FIO2 (0.08-0.1) from profiles at higher FIO2 and integrating those signals in the range from 3 to 5 micros. In each validation experiment, optoacoustic signals showed tight temporal association and good linear correlation with measured oxyhemoglobin saturation (r2 0.75 to 0.99 for eight individual experiments). CONCLUSIONS: The optoacoustic system detects signals induced in the SSS and optoacoustic signals from the SSS linearly correlate with oxyhemoglobin saturation. The data suggest that the optoacoustic technique merits clinical evaluation.

Acoustic Stimulation↗

Continuous, noninvasive monitoring of total hemoglobin concentration by an optoacoustic technique.

Measurement of total hemoglobin concentration [Hgb] is a blood test that is widely used to evaluate outpatients, hospital inpatients, and surgical patients, especially those undergoing surgery associated with extensive blood loss, rapid fluid administration, and transfusion of packed red blood cells. Current techniques for measurement of [Hgb] are invasive (requiring blood sampling) and cannot provide real-time, continuous monitoring. We propose to use an optoacoustic technique for noninvasive and continuous monitoring of [Hgb]. The high resolution of the optoacoustic technique may provide accurate measurement of [Hgb] by detection and analysis of optoacoustic signals induced by short optical pulses in blood circulating in arteries or veins. We designed, built, and tested in vitro (in both tissue phantoms and in preliminary in vivo experiments) a portable optoacoustic system for the monitoring of [Hgb] in the radial artery. The system includes a nanosecond laser operating in the near-infrared spectral range and a sensitive optoacoustic probe designed to irradiate the radial artery through the skin and detect optoacoustic signals induced in blood. Results of our studies demonstrated that (1) the slope of optoacoustic waves induced in blood in the transmission mode is linearly dependent on [Hgb] in the range from 6.2 to 12.4 g/dl, (2) optoacoustic signals can be detected despite optical attenuation in turbid tissue phantoms with a thickness of 1 cm, and (3) the optoacoustic system detects signals induced in blood circulating in the radial artery. These data suggest that the optoacoustic system can be used for accurate, noninvasive, real-time, and continuous monitoring of [Hgb].

Acoustics↗

Hemodynamic and cardiac contractile function during sepsis caused by cecal ligation and puncture in mice.

Sepsis is among the leading causes of death in the critically ill, yet the pathophysiology of sepsis is incompletely understood. Genetically engineered mice offer a unique opportunity to explore the cellular and molecular pathogenesis of sepsis. However, the hemodynamic responses of mice during sepsis are not completely understood because of the difficulty in performing cardiovascular measurements in mice. We used a 1.4-F pressure and conductance catheter to measure hemodynamics in wild-type C57BL/6J mice during sepsis caused by cecal ligation and puncture. Septic mice exhibited significant hypothermia compared with the sham group. In addition, there was a progressive decrease in mean arterial blood pressure and systemic vascular resistance in septic mice as well as an increase in stroke volume and cardiac output. Sepsis also caused a significant time-dependent impairment of left ventricular function as indicated by decreased dp/dtmax and dp/dtmin. The slope of end systolic pressure volume relationship also decreased over time, as did the time varying maximum elastance and preload-recruitable stroke work of the left ventricle. In conclusion, septic mice exhibit hemodynamic alterations during sepsis that are similar to those observed in humans. The miniaturized conductance catheter allows for effective measurements of hemodynamic function in septic mice and provides measurements that cannot be obtained using other cardiovascular monitoring techniques.

Animals↗

Hypotensive resuscitation of multiple hemorrhages using crystalloid and colloids.

Hypotensive resuscitation has been advocated as a better means to perform field resuscitation of penetrating trauma. Our hypothesis is that hypotensive resuscitation using either crystalloid or colloid provides equivalent or improved metabolic function while reducing the overall fluid requirement for resuscitation of hemorrhage. We compared hypotensive and normotensive resuscitation of hemorrhage using lactated Ringer's (LR) with hypotensive resuscitation using Hextend (Hex), 6% hetastarch in isotonic buffered saline. Instrumented conscious sheep were hemorrhaged in three separate bleeds, 25 mL/kg at T0 and 5 mL/kg at both T50 and T70. Resuscitation was started at T30 and continued until T180. Hypotensive resuscitation to a mean arterial pressure (MAP) of 65 mmHg was performed with LR or Hex using a closed-loop resuscitation (CLR) system for a LR-65 and Hex-65 treatment protocol. A control treatment protocol was resuscitation with LR to a MAP target of 90 mmHg, LR-90. All treatment protocols were successfully resuscitated to near target levels. Two animals in the hypotensive treatment protocols died during the second and third bleedings, one in the LR-65 and one in the Hex-65 treatment protocol. Mean infused volumes were 61.4 +/- 11.3, 18.0 +/- 5.9, and 11.6 +/- 1.9 mL/kg in the LR-90, LR-65, and Hex-65 treatments, respectively (*P < 0.05 versus LR-90). Mean minimum base excess (BE) values were +1.9 +/- 1.4, -5.8 +/- 4.3, and -5.9 +/- 4.0 mEq/L in the LR-90, LR-65, and Hex-65 treatments, respectively. Hypotensive resuscitation with LR greatly reduced volume requirements as compared with normotensive resuscitation, and Hex achieved additional volume sparing. However, trends toward lower BE values and the occurrence of deaths only in the hypotensive treatment protocols suggest that resuscitation to a target MAP of 65 mmHg may be too low for optimal outcomes.

Animals↗

Lubeluzole and conditioned learning after cerebral ischemia.

Lubeluzole [S-4-(2-benzothiazolylmethylamino)-alpha-((3,4-difluorophenoxy)methyl)-1-piperidineethanol] reduces the severity of cerebral injury in animal models of brain ischemia. Its beneficial effects may include decreased concentration of extracellular glutamate, blockade of sodium and calcium channels, and attenuation of nitric oxide-mediated neuronal death. Previous studies have shown that global cerebral ischemia in rabbits impaired the subsequent acquisition of a trace-conditioned eyeblink reflex. Here, we examined the effect of preischemic treatment with lubeluzole on the acquisition of a trace-conditioned eyeblink response after 6.5 min of global cerebral ischemia. Three groups of rabbits underwent cerebral ischemia: one group underwent ischemia alone (I) and two groups underwent ischemia and also received lubeluzole (L(1), 1.25 mg/kg, and L(2), 2.5 mg/kg). All animals were subsequently trained using classical trace conditioning. Each training session consisted of the presentation of the conditioned stimulus (an 85-dB, 6-kHz auditory tone lasting for 100 ms) followed by a trace interval (a period of 300 ms during which no external stimulus was delivered) followed finally by the delivery of the unconditioned stimulus (a 150-ms puff of air directed at the cornea). We found that animals receiving preischemic administration of 1.25 mg/kg of lubeluzole demonstrated a significantly improved acquisition of the trace-conditioned reflex as compared to animals that did not receive lubeluzole. This finding demonstrates improved long-term neurobehavioral outcome with preischemic administration of 1.25 mg/kg of lubeluzole.

Animals↗

Near-infrared spectroscopy-guided closed-loop resuscitation of hemorrhage.

BACKGROUND: Endpoint resuscitation has been suggested as a better means to resuscitate penetrating injury. We performed computer-controlled closed-loop resuscitation using invasive cardiac output (CO) or noninvasive skeletal muscle oxygen saturation (SkMusSO(2)) via near infrared spectroscopy (NIRS). METHODS: Conscious sheep received a 4.0-mm aortotomy and uncontrolled hemorrhage at t = 0 min (T0) while resuscitation started at T20 using lactated Ringer's solution. RESULTS: The aortotomy rapidly decreased the mean arterial pressure (MAP) to approximately 30 mm Hg and CO to 20% to 30% of baseline. The SkMusSO(2) endpoint group required only half as much fluid through 4 hours of resuscitation as the CO endpoint group (34.9 +/- 8.4 mL/kg vs. 63.1 +/- 9.4 mL/kg). CO and MAP were lower in the SkMusSO(2) group after T60. Mean infusion volumes were 180% and 100% of the bled volume collected at autopsy in the CO and SkMusSO(2) groups. Brain and muscle oxygenation and base excess were as high or higher in the CO endpoint group. CONCLUSION: Closed-loop resuscitation with either CO or SkMusSO(2) endpoints effectively performs fluid resuscitation of severe uncontrolled hemorrhagic shock. Limited resuscitation may achieve favorable clinical results with volumes less than recommended by Advanced Trauma Life Support guidelines.

Animals↗

Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study.

Replacement of invasive monitoring of cerebral venous oxygenation with noninvasive techniques offers great promise in the management of life-threatening neurologic illnesses including traumatic brain injury. We developed and built an optoacoustic system to noninvasively monitor cerebral venous oxygenation; the system includes a nanosecond Nd:YAG laser and a specially designed optoacoustic probe. We tested the system in vitro in sheep blood with experimentally varied oxygenation. Our results demonstrated that (1) the amplitude and temporal profile of the optoacoustic waves increase with blood oxygenation in the range from 24% to 92%, (2) optoacoustic signals can be detected despite optical and acoustic attenuation by thick bone, and (3) the system is capable of real-time and continuous measurements. These results suggest that the optoacoustic technique is technically feasible for continuous, noninvasive monitoring of cerebral venous oxygenation.

Feasibility Studies↗

The paracorporeal artificial lung improves 5-day outcomes from lethal smoke/burn-induced acute respiratory distress syndrome in sheep.

BACKGROUND: Our low-impedence, paracorporeal artificial lung (PAL) prototype is well-tolerated in-series with the normal sheep pulmonary circulation. Using our lethal dose 80% to 100% smoke/burn acute respiratory distress syndrome (ARDS) sheep model, we compared PAL to volume-controlled mechanical ventilation (VCMV) in a prospective, randomized, controlled, unblinded, 5-day outcome study. METHODS: Fourteen sheep were randomized to PAL (n = 8) versus VCMV (n = 6) to assess outcome. For PAL, arterial cannulas were anastomosed to the proximal and distal main pulmonary artery with an interposing snare diverting full flow through a paracorporeal loop. Acute respiratory distress syndrome was induced in both groups (48 breaths smoke insufflation, third degree burn on 40% of total body surface area). When acute respiratory distress syndrome criteria were met (24 to 30 hours after injury), the PAL was interposed in the paracorporeal loop. Both groups were managed with a VCMV algorithm minimizing tidal volume, ventilator rate, and fractional inspired concentration of oxygen (FiO2). RESULTS: Six of eight PAL versus 1 of 6 VCMV sheep survived the 5-day study. In PAL, cardiac output, mean arterial pressure, pulmonary artery pressure, left atrial pressure, and central venous pressure remained stable. Average PAL gas transfer was 218.6 +/- 17.7 mL/min O2 and 183.0 +/- 27.8 mL/min CO2. Ventilator settings 48 hours after lung injury in PAL were significantly lower (p < 0.05) than VCMV (TV 210 versus 425 mL; respiratory rate 6 versus 29 breaths/min; minute ventilation 1.2 versus 10.8 L/min; FiO2 21 versus 100%). Likewise, PaO2/FiO2 ratio was normalized in PAL and still met acute respiratory distress syndrome criteria in VCMV. The PAL wet/dry ratio was significantly lower than VCMV (6.36 +/- 0.63 versus 11.85 +/- 1.54; p = 0.008). CONCLUSIONS: In a prospective, randomized, controlled, unblinded, outcomes study, PAL decreased ventilator-induced lung injury in a lethal dose 80% to 100% ARDS model to improve 5-day survival.

Animals↗

Hemodynamic benefit of positive end-expiratory pressure during acute descending aortic occlusion.

BACKGROUND: Acute aortic occlusion in vascular surgery patients abruptly increases arterial resistance and blood pressure, which, in turn, makes subsequent volume expansion during cross-clamp application difficult. The use of vasodilatory drugs or volatile anesthetic agents to attenuate this response may have persistent detrimental effects after clamp removal. Another potential therapy that produces rapid effects on myocardial loading conditions is positive end-expiratory pressure (PEEP). In a porcine model of acute aortic clamping, the hemodynamic consequences of 15 cm H(2)O PEEP with and without plasma volume expansion were studied.(2) METHODS: Forty anesthetized pigs underwent 30-min occlusion of the abdominal aorta 1 cm above the origin of the celiac artery. Animals were randomly divided into four treatment groups (n = 10 each) to receive 15 cm H(2)O PEEP or zero end-expiratory pressure (ZEEP) with or without plasma volume expansion using 6% hetastarch (10 ml/kg) during cross-clamp application. Mean aortic pressure was measured with a transducer-tipped catheter placed in the ascending aorta; stroke volume was calculated using thermodilution cardiac output. End-expiratory pressure was discontinued upon aortic declamping, and animals were studied over the ensuing 30-min period. RESULTS: Aortic occlusion doubled systemic vascular resistance in all groups. Mean aortic blood pressure increased significantly in both ZEEP groups at 1 and 5 min but not in animals treated with 15 cm H(2)O PEEP. The application of PEEP with aortic cross-clamping reduced cardiac output and stroke volume by nearly 50%. Cardiac output and stroke volume increased after volume expansion regardless of end-expiratory pressure. After aortic declamping, aortic blood pressure decreased in all groups but was significantly greater in the PEEP + volume group than in either ZEEP group. Similarly, 5 min after declamping, stroke volume was greatest in the PEEP + volume animals. CONCLUSIONS: Fifteen cm H(2)O PEEP reduces the hypertensive response to acute aortic occlusion and allows concomitant volume expansion. Consequently, stroke volume and blood pressure are better maintained after clamp removal in PEEP + volume animals. The use of PEEP during acute aortic occlusion in patients may allow rapid control of loading conditions to attenuate systemic hypertension while permitting simultaneous volume expansion.

Animals↗

Comparison of transfusion with DCLHb or pRBCs for treatment of intraoperative anemia in sheep.

Isoflurane-anesthetized sheep were transfused with packed red blood cells (pRBCs) or diaspirin cross-linked hemoglobin (DCLHb) for treatment of intraoperative hemorrhage. A rapid 15-min hemorrhage with lactated Ringer (LR) infusion maintained filling pressure at baseline and reduced blood hemoglobin (Hb) to ~5 g/dl. Sheep received 2 g/kg Hb, DCLHb (n = 6), or pRBCs (n = 7); control group received LR alone (n = 6). After 2 h, anesthesia was discontinued; sheep were monitored in the animal intensive care unit for 48 h. DCLHb expanded blood volume more, but increased total blood Hb less, than pRBCs. Lower Hb and increased methemoglobin resulted in lower arterial oxygen content compared with the pRBCs. DCLHb caused pulmonary hypertension (from 13 to 30 mmHg) and elevated filling pressure (from 6 to 15 mmHg). Cardiac outputs (CO) were similar for all groups during anesthesia; however, during recovery CO increased only in the LR and packed pRBCs groups. DCLHb may limit the reflex ability to increase CO after volume expansion. Hemodynamic effects of DCLHb may be exaggerated when infused after large-volume LR.

Anemia↗

Arterio-venous CO2 removal (AVCO2R) perioperative management: rapid recovery and enhanced survival.

Percutaneous arteriovenous CO2 removal (AVCO2R) uses a simple arteriovenous (A-V) shunt for near-total CO2 removal that allows significant reductions in minute ventilation. We critically reviewed our algorithm-directed perioperative anesthesia management in our LD40 ovine smoke-burn injury model of acute respiratory distress syndrome (ARDS) treated with AVCO2R. General anesthesia is required for: (1) Vascular access followed by ARDS model development by smoke insufflation (36 breaths) plus 40% TBSA III degrees burn with mechanical ventilation. Induction: 12.5 mg/kg im ketamine and 4% halothane by mask, then intubation. Maintenance: 1.0-2.5% halothane in 100% O2; (2) When PaO2/FiO2 < 200 (48-52 h), sheep randomized to the AVCO2R (n = 8) or SHAM (n = 8) procedure. Induction: 66% N2O and 5% isoflurane in balance O2. Maintenance: 1.5-2.5% isoflurane in 100% O2 for AVCO2R, cannulation (10F carotid artery, 14F jugular vein); (3) Postop, both groups had algorithm-directed ventilator management, identical heparin (ACT > 300 s), fluid, and analgesia management. All sheep met criteria for ARDS, survived anesthesia, and were standing by 0.5-5 h. There were no complications attributable to anesthesia. The absence of anesthesia-related complications allows model development for outcomes studies for ARDS in general and AVCO2R specifically.

Algorithms↗

The effect of augmented hemodynamics on blood flow during arteriovenous carbon dioxide removal.

Arteriovenous carbon dioxide removal (AVCO2R) as an alternative treatment for acute respiratory distress syndrome uses a low resistance gas exchanger in a simple arteriovenous shunt to achieve total CO2 removal and allow lung rest. We have previously shown in our clinically relevant LD40 ovine model of smoke/burn induced acute respiratory distress syndrome that AVCO2R allows significant decreases in respiratory rate, tidal volume, peak airway pressure, and FiO2, as compared with standard mechanical ventilation. In addition, we have shown in a prospective randomized outcomes study that AVCO2R increases ventilator free days, decreases ventilator dependent days, and significantly improves survival. The purpose of this study is to further define the limits of AVCO2R through hemodynamic augmentation and evaluation of peak end expiratory pressure (PEEP). Administration of an alpha agonist (phenylephrine) and a beta agonist (isoproterenol) increased mean arterial pressure (MAP) and cardiac output (CO), respectively. MAP increases ranged from 2.4% to 94.4% and CO increases ranged from 33% to 146%. Phenylephrine caused elevations in MAP (2.4-94.4%) and AVCO2R flow (9-67%), and CO never decreased more than 10%. Isoproterenol administration increased CO (33-146%), decreased MAP (9-54%), and decreased AVCO2R flow (11-42%). In a second group, PEEP was increased stepwise from 0 (baseline) to 20 cm H2O. Increasing PEEP did not result in significant hemodynamic changes (< 10% change from baseline PEEP) for MAP, CO, or AVCO2R flow. In conclusion, alpha agonist administration increased AVCO2R blood flow, whereas beta agonist administration decreased MAP and AVCO2R blood flow, despite CO elevation. Various levels of PEEP are well tolerated and thus allow a range of options during AVCO2R.

Adrenergic alpha-Agonists↗

High-frequency percussive ventilation with systemic heparin improves short-term survival in a LD100 sheep model of acute respiratory distress syndrome.

We undertook an assessment of high-frequency percussive ventilation (HFPV) and systemic heparin on survival in our LD100 sheep model of smoke/burn-induced acute respiratory distress syndrome (ARDS). This was a prospective controlled outcomes study in a large animal critical care laboratory. ARDS was induced in 13 sheep by a combination of 48 cotton smoke breaths and 40% full-thickness cutaneous burn (LD100) followed by mechanical ventilation (15 ml/kg tidal volume). After meeting ARDS criteria (PaO2/FiO2 < 200), the sheep were divided into high-frequency percussive ventilation (HFPV; n = 7) or volume-controlled mechanical ventilation (VCMV; n = 6) groups. Both groups received systemic heparin to achieve an ACT 180-300 seconds. HFPV was managed with the Volumetric Diffusive Respiration Ventilator (Percussionaire Corp., Sandpoint, ID). The VCMV group was managed with up to 10 ml/kg tidal volume. Arterial blood gases and ventilator settings were monitored every 6 hours after onset of ARDS. HFPV did not affect sheep hemodynamics. Survival 84 hours after smoke and burn injury was significantly greater in the HFPV (7/7, 100%) compared with the VCMV group (3/6, 50%, P < .05). PaCO2 was significantly greater in VCMV group at 36, 48, and 72 hours after smoke and burn injury. PaO2/FiO2 after 36 hours of smoke and burn injury in the HFPV group was improved compared with the VCMV group, but no statistical difference was found. In the VCMV group, peak airway pressure was decreased to 19.7 +/- 2.2 cm H2O at 36 hours from 29 +/- 2.8 at 24 hours as the tidal volume changed from 15 ml/kg to 10 ml/kg and then gradually increased to 39 +/- 5.6 cm H2O at 72 hours. In the HFPV group, peak inspiratory pressure kept constant at a level of 30 cmH2O. In our smoke/burn-induced LD100 sheep model of ARDS, volume-controlled mechanical ventilation with systemic heparin achieved a 50% survival whereas HFPV with systemic heparin achieved 100% survival at 60 hours after the onset of ARDS.

Animals↗

Toward ambulatory arteriovenous CO2 removal: initial studies and prototype development.

Extracorporeal arteriovenous carbon dioxide removal (AVCO2R) using percutaneous cannulae and a low resistance gas exchanger achieves near total CO2 removal, allowing lung rest and potentially improving survival. AVCO2R, redesigned to allow ambulation, has potential as treatment for severe chronic obstructive pulmonary disease or rehabilitation before lung transplant. The purposes of this study were to 1) determine the optimal ambulatory access for AVCO2 removal and 2) develop a prototype Ambulatory-AVCO2R gas exchanger. Initially, reinforced Gore-Tex 6 mm (two) and 8 mm (four) grafts were anastomosed to sheep carotid arteries and jugular veins as a loop in parallel to the cranial circulation to determine blood flow capabilities. Blood flow was 100-150 ml/min with a 14 gauge dialysis needle, and transected 6 mm Gore-Tex grafts achieved 500-900 ml blood flow, whereas transected 8 mm grafts achieved up to 2000 ml/min flow. The polytetrafluoroethylene (PTFE) loops were then connected to our newly developed ultra low resistance pumpless gas exchanger for ambulatory AVCO2R. The average pressure gradient across the prototype Ambulatory-AVCO2R gas exchangers (n = 5) was 2.8 +/- 0.8 mm Hg, and mean CO2 removal was 104.8 +/- 14.0 ml/min, with an average blood flow of 900 ml/min. We conclude that an 8 mm Gore-Tex reinforced graft arteriovenous loop supplies ample blood flow for our new ultra low resistance Ambulatory-AVCO2R to achieve near total CO2 removal.

Animals↗

Short term performance evaluation of a perfluorocopolymer coated gas exchanger for arteriovenous CO2 removal.

A new perfluorocopolymer coating for micropore hollow fiber gas exchangers was developed to improve gas exchange, reduce plasma leakage, and reduce blood-surface interactions. The present authors evaluated gas exchanger performance using this new coating in a prospective, randomized, controlled, unblinded, large animal model of CO2 retention. Adult sheep (30-40 kg), under general anesthesia, underwent cannulation of the carotid artery (12 F) and jugular vein (14 F). The perfluorocopolymer coated (n = 5) and uncoated (n = 5) gas exchangers were attached to an arteriovenous CO2 removal (AVCO2R) circuit. Blood gases, CO2 removal, and hemodynamics were monitored throughout the 6 hour study. Average CO2 removal was 107.6 +/- 15.6 ml/min (coated) vs. 93.0 +/- 13.9 ml/min (uncoated; p < 0.01). PaCO2 and CO2 removal for both coated and uncoated did not deteriorate significantly over the study. Average AVCO2R blood flow was 1,130 +/- 25 ml/min (coated) versus 1,101 +/- 79 ml/min (uncoated; p = not significant). Likewise, cardiac output and AVCO2R blood flow did not change over the duration of the study. No significant differences in the pressure gradient or resistance between devices (coated, 6.89 +/- 1.14 mm Hg/L/min; uncoated, 6.42 +/- 0.23 mm Hg/L/min) was noted. The authors concluded that the new perfluorocopolymer coated gas exchanger improved CO2 removal without compromising hemodynamics in an acute performance evaluation.

Animals↗