Radiation doses from venous access procedures.

PURPOSE: To retrospectively analyze radiation dose data for six common venous access procedures. MATERIALS AND METHODS: Institutional review board approval was obtained for this HIPAA-compliant study; informed consent was not required. Data review was limited to a quality assurance database. Patient medical records were not reviewed. We retrospectively analyzed radiation dose data from a prospective quality assurance program. Dose data were analyzed for 1010 instances of six different venous access placement procedures performed between February 1998 and July 2004. Radiation dose measurements were generated automatically by the interventional fluoroscopy units and were recorded at the conclusion of each procedure. Descriptive and summary statistical analyses were performed to determine median, minimum, and maximum values of radiation dose for each procedure. A P value of less than .05 indicated a significant difference. Because the data distribution was highly skewed, logarithmic transformation was performed. Dose data for four different venous access procedures (excluding chest port placement and peripherally inserted central catheter placement) were compared with a one-way analysis of variance. Pairwise comparisons with the Tukey honestly significant difference test were subsequently performed for each analogue where analysis of variance demonstrated a significant result. RESULTS: No procedure yielded a cumulative dose of more than 950 mGy or a peak skin dose of more than 760 mGy. The highest mean cumulative dose (ie, 88 mGy), mean dose-area product (ie, 873 cGy . cm(2)), and mean peak skin dose (ie, 43 mGy) were observed for tunneled dialysis catheter placements. Significant differences in dose were observed for tunneled catheter placement versus nontunneled catheter placement (<.001 to .027). No significant differences in dose were observed for larger-diameter versus smaller-diameter catheters. CONCLUSION: Radiation doses from venous access procedures are low. Even extreme outlier cases are unlikely to produce doses high enough to cause skin effects, especially when knowledgeable operators using well-calibrated equipment perform the procedures.

Analysis of Variance↗

Radiation dose and cancer risk among pediatric patients undergoing interventional neuroradiology procedures.

BACKGROUND: During interventional neuroradiology procedures, patients can be exposed to moderate to high levels of radiation. Special considerations are required to protect children, who are generally more sensitive to the short- and long-term detrimental effects of radiation exposure. Estimates of dose to the skin of children from certain interventional procedures have been published elsewhere, but we are not aware of data on dose to the brain or on the long-term risk of cancer from brain radiation. OBJECTIVES: Our goals were to estimate radiation doses to the brain in 50 pediatric patients who had undergone cerebral embolization and to assess their lifetime risks of developing radiation-related brain cancer. MATERIALS AND METHODS: Entrance-peak skin dose and various assumptions on conditions of exposure were used as input for dosimetric calculations to estimate the spatial pattern of dose within the brain and the average dose to the whole brain for each child. The average dose and the age of the child at time of exposure were used to estimate the lifetime risk of developing radiation-related brain cancer. RESULTS: Among the 50 patients, average radiation doses to the brain were estimated to vary from 100 mGy to 1,300 mGy if exposed to non-collimated fields and from 20 mGy to 160 mGy for collimated, moving fields. The lifetime risk of developing brain cancer was estimated to be increased by 2% to 80% as a result of the exposure. Given the very small lifetime background risk of brain tumor, the excess number of cases will be small even though the relative increase might be as high as 80%. CONCLUSION: ALARA principles of collimation and dose optimization are the most effective means to minimize the risk of future radiation-related cancer.

Adolescent↗

Quality improvement guidelines for uterine artery embolization for symptomatic leiomyomata.

Uterine artery embolization (UAE) is assuming an important role in the treatment of women with symptomatic uterine leiomyomata worldwide. The following guidelines, which have been jointly published with the Society of Interventional Radiology in the Journal of Vascular and Interventional Radiology, are intended to ensure the safe practice of UAE by identifying the elements of appropriate patient selection, anticipated outcomes, and recognition of possible complications and their timely address.

Embolization, Therapeutic↗

Radiation doses in interventional radiology procedures: the RAD-IR Study. Part III: Dosimetric performance of the interventional fluoroscopy units.

PURPOSE: To present the physics data supporting the validity of the clinical dose data from the RAD-IR study and to document the performance of dosimetry-components of these systems over time. MATERIALS AND METHODS: Sites at seven academic medical centers in the United States prospectively contributed data for each of 12 fluoroscopic units. All units were compatible with International Electrotechnical Commission (IEC) standard 60601-2-43. Comprehensive evaluations and periodic consistency checks were performed to verify the performance of each unit's dosimeter. Comprehensive evaluations compared system performance against calibrated ionization chambers under nine combinations of operating conditions. Consistency checks provided more frequent dosimetry data, with use of each unit's built-in dosimetry equipment and a standard water phantom. RESULTS: During the 3-year study, data were collected for 48 comprehensive evaluations and 581 consistency checks. For the comprehensive evaluations, the mean (95% confidence interval range) ratio of system to external measurements was 1.03 (1.00-1.05) for fluoroscopy and 0.93 (0.90-0.96) for acquisition. The expected ratio was 0.93 for both. For consistency checks, the values were 1.00 (0.98-1.02) for fluoroscopy and 1.00 (0.98-1.02) for acquisition. Each system was compared across time to its own mean value. Overall uncertainty was estimated by adding the standard deviations of the comprehensive and consistency measurements in quadrature. The authors estimate that the overall error in clinical cumulative dose measurements reported in RAD-IR is 24%. CONCLUSION: Dosimetric accuracy was well within the tolerances established by IEC standard 60601-2-43. The clinical dose data reported in the RAD-IR study are valid.

Fluoroscopy↗

Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose.

PURPOSE: To determine patient radiation doses for interventional radiology and neuroradiology procedures, to identify procedures associated with higher radiation doses, and to determine the effects of various parameters on patient doses. MATERIALS AND METHODS: A prospective observational study was performed at seven academic medical centers. Each site contributed demographic and radiation dose data for subjects undergoing specific procedures in fluoroscopic suites equipped with built-in cumulative dose (CD) and dose-area-product (DAP) measurement capability compliant with International Electrotechnical Commission standard 60601-2-43. The accuracy of the dosimetry was confirmed by comprehensive measurements and by frequent consistency checks performed over the course of the study. RESULTS: Data were collected on 2,142 instances of interventional radiology procedures, 48 comprehensive physics evaluations, and 581 periodic consistency checks from the 12 fluoroscopic units in the study. There were wide variations in dose and statistically significant differences in fluoroscopy time, number of images, DAP, and CD for different instances of the same procedure, depending on the nature of the lesion, its anatomic location, and the complexity of the procedure. For the 2,142 instances, observed CD and DAP correlate well overall (r = 0.83, P <.000001), but correlation in individual instances is poor. The same is true for the correlation between fluoroscopy time and CD (r = 0.79, P <.000001). The correlation between fluoroscopy time and DAP (r = 0.60, P <.000001) is not as good. In 6% of instances (128 of 2,142), which were principally embolization procedures, transjugular intrahepatic portosystemic shunt (TIPS) procedures, and renal/visceral artery stent placements, CD was greater than 5 Gy. CONCLUSIONS: Most procedures studied can result in clinically significant radiation dose to the patient, even when performed by trained operators with use of dose-reducing technology and modern fluoroscopic equipment. Embolization procedures, TIPS creation, and renal/visceral artery stent placement are associated with a substantial likelihood of clinically significant patient dose. At minimum, patient dose data should be recorded in the medical record for these three types of procedures. These data should include indicators of the risk of deterministic effects as well as the risk of stochastic effects.

Adolescent↗

Radiation doses in interventional radiology procedures: the RAD-IR study: part II: skin dose.

PURPOSE: To determine peak skin dose (PSD), a measure of the likelihood of radiation-induced skin effects, for a variety of common interventional radiology and interventional neuroradiology procedures, and to identify procedures associated with a PSD greater than 2 Gy. MATERIALS AND METHODS: An observational study was conducted at seven academic medical centers in the United States. Sites prospectively contributed demographic and radiation dose data for subjects undergoing 21 specific procedures in a fluoroscopic suite equipped with built-in dosimetry capability. Comprehensive physics evaluations and periodic consistency checks were performed on each unit to verify the stability and consistency of the dosimeter. Seven of 12 fluoroscopic suites in the study were equipped with skin dose mapping software. RESULTS: Over a 3-year period, skin dose data were recorded for 800 instances of 21 interventional radiology procedures. Wide variation in PSD was observed for different instances of the same procedure. Some instances of each procedure we studied resulted in a PSD greater than 2 Gy, except for nephrostomy, pulmonary angiography, and inferior vena cava filter placement. Some instances of transjugular intrahepatic portosystemic shunt (TIPS) creation, renal/visceral angioplasty, and angiographic diagnosis and therapy of gastrointestinal hemorrhage produced PSDs greater than 3 Gy. Some instances of hepatic chemoembolization, other tumor embolization, and neuroembolization procedures in the head and spine produced PSDs greater than 5 Gy. In a subset of 709 instances of higher-dose procedures, there was good overall correlation between PSD and cumulative dose (r = 0.86; P <.000001) and between PSD and dose-area-product (r = 0.85, P <.000001), but there was wide variation in these relationships for individual instances. CONCLUSIONS: There are substantial variations in PSD among instances of the same procedure and among different procedure types. Most of the procedures observed may produce a PSD sufficient to cause deterministic effects in skin. It is suggested that dose data be recorded routinely for TIPS creation, angioplasty in the abdomen or pelvis, all embolization procedures, and especially for head and spine embolization procedures. Measurement or estimation of PSD is the best method for determining the likelihood of radiation-induced skin effects. Skin dose mapping is preferable to a single-point measurement of PSD.

Fluoroscopy↗

Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures.

PURPOSE: Four techniques used to estimate radiation risk were compared to determine whether commonly used dosimetry measurements permit reliable estimates of skin dose. Peak skin dose (PSD) is known to be the most reliable estimate of risk to skin. The purpose of this study is to determine peak skin dose with use of real-time software measurements and to correlate other measures of dose with PSD. MATERIALS AND METHODS: Two hundred twelve patients undergoing arch aortography and bilateral carotid arteriography (referred to as "carotid"), abdominal aortography and bilateral lower extremity runoff ("runoff"), or tunneled chest wall port placement ("port") were studied. Fluoroscopy time, dose-area product (DAP), and cumulative dose at the interventional reference point were recorded for all procedures; PSD was recorded for a subset of 105 procedures. The dose index, defined as the ratio between PSD and cumulative dose, was also determined. RESULTS: In general, correlation values for comparisons between fluoroscopy time and the other measures of dose (r =.29 to.78) were lower than values for comparisons among DAP, cumulative dose, and PSD (r =.52 to.94). For all procedures, pair-wise correlations between DAP, cumulative skin dose, and PSD were statistically significant (P <.01) The ratio between PSD and cumulative skin dose (dose index) was significantly different for ports versus other procedures (carotid, Z = 4.62, P <.001; runoff, Z = 4.52, P <.001), but carotid and runoff procedures did not differ significantly in this regard (Z = 0.746, P =.22). Within each individual procedure type, the range of values for the dose index varied 156.7-fold for carotid arteriography, 3.2-fold for chest ports, and 175-fold for aortography and runoff. CONCLUSION: Fluoroscopy time is a poor predictor of risk because it does not correlate well with PSD. Cumulative dose and DAP are not good analogues of PSD because of weak correlations for some procedures and because of wide variations in the dose index for all procedures.

Computer Systems↗