LC-ESI-MS/MS on an ion trap for the determination of LSD, iso-LSD, nor-LSD and 2-oxo-3-hydroxy-LSD in blood, urine and vitreous humor.

A method has been developed for the simultaneous determination of lysergic acid diethylamide (LSD), its epimer iso-LSD, and its main metabolites nor-LSD and 2-oxo-3-hydroxy LSD in blood, urine, and, for the first time, vitreous humor samples. The method is based on liquid/liquid extraction and liquid chromatography-multiple mass spectrometry detection in an ion trap mass spectrometer, in positive ion electrospray ionization conditions. Five microliter of sample are injected and analysis time is 12 min. The method is specific, selective and sensitive, and achieves limits of quantification of 20 pg/ml for both LSD and nor-LSD in blood, urine, and vitreous humor. No significant interfering substance or ion suppression was identified for LSD, iso-LSD, and nor-LSD. The interassay reproducibilities for LSD at 20 pg/ml and 2 ng/ml in urine were 8.3 and 5.6%, respectively. Within-run precision using control samples at 20 pg/ml and 2 ng/ml was 6.9 and 3.9%. Mean recoveries of two concentrations spiked into drug free samples were in the range 60-107% in blood, 50-105% in urine, and 65-105% in vitreous humor. The method was successfully applied to the forensic determination of postmortem LSD levels in the biological fluids of a multi drug abuser; for the first time, LSD could be detected in vitreous humor.

Forensic Toxicology↗

Potentials of ion trap collisional spectrometry for liquid chromatography/electrospray ionization tandem mass spectrometry determination of buprenorphine and nor-buprenorphine in urine, blood and hair samples.

A liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method has been developed for the analysis of buprenorphine (BUP) and nor-buprenorphine (NBUP) in biological fluids. Analytes are isolated from urine and blood, after addition of d4-buprenorphine (d4-BUP) as internal standard, by solid-phase extraction. Preparation of hair involves external decontamination, mechanical pulverization, overnight incubation in acidic medium, and neutralization prior to extraction. Enzymatic hydrolysis with beta-glucuronidase may be performed to distinguish between free and total BUP. Chromatographic separation is accomplished by gradient elution on a cyanopropyl 2.1 x 150 mm column. Positive ion ESI and MS analyses are carried out in an ion trap mass spectrometer. The use of this mass analyzer allows effective collisional experiments to be performed on ESI-generated MH+ species. Abundant product ions are produced, which can be monitored together with precursor ions without losing sensitivity. Thus, assay selectivity is definitely increased with respect to LC/ESI-MS/MS methods in which only precursor ions are monitored. The method has good linearity (calibration curves were linear in the range 0.1-10 ng/mL in urine and blood, in the range 10-160 pg/mg in hair) and limits of detection of 0.05 ng/mL for both BUP and NBUP in blood and urine samples, of 4 pg/mg for both analytes in hair. Both intra- and inter-assay precision and accuracy were satisfactory at three concentrations studied: relative standard deviations were <13.7% in urine, <17.3% in blood, <17.8% in hair; percent deviation of the mean from the true value was always <10.5% in urine and blood, <16.1% in hair. The method can be used to determine both analytes in the urine and hair of drug addicts on replacement therapy, and in post-mortem blood specimens when there is suspicion of drug-related death.

Analgesics, Opioid↗

An improved method for cyanide determination in blood using solid-phase microextraction and gas chromatography/mass spectrometry.

A new method is described for the qualitative and quantitative analysis of cyanide, a very short-acting and powerful toxic agent, in human whole blood. It involves the conversion of cyanide into hydrogen cyanide and its subsequent headspace solid-phase microextraction (HS-SPME) and detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode. Optimizing the conditions for the GC/MS (type of column, injection conditions, temperature program) and SPME (choice of SPME fiber, effect of salts, adsorption and desorption times, adsorption temperature) led to the choice of a 75-microm carboxen/polydimethylsiloxane SPME fiber, with D3-acetonitrile as internal standard, and a capillary GC column with a polar stationary phase. Method validation was carried out in terms of linearity, precision and accuracy in both aqueous solutions and blood. The limit of detection (LOD) and limit of quantitation (LOQ) were determined only in aqueous solutions. The assay is linear over three orders of magnitude (water 0.01-10, blood 0.05-10 microg/mL); and the LOD and LOQ in water were 0.006 and 0.01 microg/mL, respectively. Good intra- and inter-assay precision was obtained, always <8%. The method is simple, fast and sensitive enough for the rapid diagnosis of cyanide intoxication in clinical and forensic toxicology.

Cyanides↗

Gas chromatography/mass spectrometry determination of amphetamine-related drugs and ephedrines in plasma, urine and hair samples after derivatization with 2,2,2-trichloroethyl chloroformate.

A new analytical approach, based on derivatization with 2,2,2-trichloroethyl chloroformate and gas chromatography/mass spectrometry (GC/MS), was investigated for qualitative and quantitative analyses of a large range of amphetamine-related drugs and ephedrines in plasma, urine and hair samples. Sample preparation involved alkaline extraction of analytes from biological samples using Extrelut columns, after addition of the internal standard 3,4-methylenedioxypropylamphetamine (MDPA), and subsequent derivatization to produce 2,2,2-trichloroethylcarbamates. GC/MS analyses, in splitless mode using a slightly polar 30-m capillary column, were performed with quadrupole or ion trap instruments. MS acquisition modes were electron ionization (EI) in full-scan or selected ion monitoring (SIM) modes (quadrupole), and full-scan MS or MS/MS modes with chemical ionization (CI) conditions (ion trap). EI spectra of 2,2,2-trichloroethylcarbamates showed variably abundant molecular ions as well as abundant diagnostic fragment ions, both characterized by ion clusters reflecting the isotope distribution of three chlorine atoms in the derivatized molecules. CI spectra showed abundant protonated molecules. Quantitative studies using EI SIM conditions gave recoveries in the range 74-89%, linear response over ranges of 10-2000 ng/mL (plasma and urine) and 0.20-20 ng/mg (hair), with corresponding limits of detection in the ranges 2-5 ng/mL and 0.1-0.2 ng/mg. Potential applications (following full method validation) include clinical and forensic toxicology, as well as doping control.

Amphetamines↗

AlIII ion complexes of saccharic acid and mucic acid: a solution and solid-state study.

The Al(III)-binding abilities of two aldaric acids, D-saccharic acid and mucic acid (the neutral form is denoted as H(2)L), were studied in solution by means of pH potentiometric, (1)H and (13)C NMR, and ESI-MS techniques. The most probable conformations and isomeric binding modes of the complexes formed in solution were determined by density functional theory (DFT) calculations. A solid D-saccharic acid complex K(2)[[Al(LH(-2))(H(2)O)](2)].H(2)O was isolated and crystallographically characterised. The two alcoholic hydroxy groups alpha to the terminal COO(-) groups were found to take part in the coordination, but in different ways. One of them coordinates in a bridging mode. Detailed ESI-MS and NMR studies proved that the complex retains its structure in solution. However, depending on the ligand and the pH, such complexes may exist in two isomeric forms. DFT calculations on the ion [[Al(LH(-2))(H(2)O)](2)](2-) revealed that several orbitals participate in stabilizing the dimeric arrangement.

Aluminum↗

Detection of thiopental and pentobarbital in head and pubic hair in a case of drug-facilitated sexual assault.

The quali-quantitative determination of two barbiturates, thiopental and its metabolite pentobarbital, in head and pubic hair samples of a woman who had been sexually assaulted during hospitalisation, is reported. Hair was analysed by means of solid-phase microextraction (SPME) and gas chromatography-multiple mass spectrometry (GC-MS-MS), in chemical ionisation conditions. Thiopental and pentobarbital were found in three proximal head hair segments (sample 1A: 0.30 and 0.40 ng/mg; sample 1B: 0.20 and 0.20 ng/mg; sample 3: 0.15 and 0.20 ng/mg) and pubic hair sample. Two distal head hair segments were negative for both barbiturates. Despite the lack of collection and toxicological analysis of blood or urine samples within the hospital setting, analytical findings from hair revealed the use of the anaesthetic agent thiopental to sedate the victim quickly and deeply and commit sexual assault.

Female↗

Endogenous gamma-hydroxybutyric acid is in the rat, mouse and human gastrointestinal tract.

By using Gas Chromatography-Mass Spectrometry high concentrations of endogenous gamma-hydroxybutyric acid (GHB) have been demonstrated in the rat and mouse gastrointestinal tract, including stomach, small intestine and colon-rectum. GHB concentrations were many folds higher than those present in the brain. High GHB concentrations have been also found in the human operatory specimen of sigmoid colon. Since GHB administration has been found to modify gastrointestinal motility via GABA(B) receptors, the present results suggest that endogenous GHB might be involved in the GABA(B) receptor-mediated control of gastrointestinal function.

3-Hydroxybutyric Acid↗

On the detailed mechanisms of collision-induced dissociation experiments performed by electrospray ion trap.

The product ion spectra obtained by electrospray ionization (ESI) ion trap instruments exhibit a higher number of fragment ions than those achieved by other ion-trap-based systems, indicating the presence of more effective energy deposition mechanisms. This behavior can be attributed to several different reasons, among which different initial internal energy of the precursor ions, pre-activation due to collisions taking place outside the trap, different target gas mixtures inside the trap, and different ion trap geometry were considered. Data obtained from experiments using a triple quadrupole instrument, CI-ion trap, and ESI-ion trap have been compared. The results so achieved seem to indicate that the presence inside the trap of neutral molecules of the solvent employed for the ESI process have a relevant role, promoting high energy deposition in the colliding ions.

Journal Article↗