PubMed Health⌕ Search

Biomedical subjects

Donghyun Cho

Publications and source records attributed to Donghyun Cho.

5 recordsLinked to original sources

HPLC and MALDI-TOF MS analysis of highly branched polystyrene: resolution enhancement by branching.

Temperature gradient interaction chromatography (TGIC) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) were applied for the characterization of highly branched polystyrenes (PS) prepared by linking living polystyryl anions using 4-chlorodimethylsilylstyrene. Reversed-phase (RP)-TGIC showed an unexpectedly high resolution according to the number of branches despite significant overlap of the molecular weight as confirmed by MALDI-TOF MS. The enhancement of the resolution is ascribed to the contribution of the nonpolar groups in the branched PS: the dimethylsilyl groups in the branching unit as well as the sec-butyl initiator groups. As the number of branches increases, the number of nonpolar groups increases, which in turn increases the RP-TGIC retention synergistically with increasing molecular weight. In contrast, a poorer resolution was found in normal-phase-TGIC, in which the nonpolar groups reduce the retention. The resolution in RP-TGIC appears superior to that of liquid chromatography at the chromatographic critical condition (LCCC) of PS. It is seemingly due to the synergistic contribution of the incremental PS molecular weight to the functionality in the branched PS in RP-TGIC while only the functionality contributes to the separation in LCCC. This type of resolution enhancement could be utilized efficiently for the analysis of highly branched polymers such as dendrimers or hyperbranched polymers.

Chromatography, High Pressure Liquid↗

Retention mechanism of poly(ethylene oxide) in reversed-phase and normal-phase liquid chromatography.

The retention behavior of low- and high-molecular-mass poly(ethylene oxide) (PEO) in reversed-phase (RP) and normal-phase (NP) liquid chromatography was investigated. In RPLC using a C18 bonded silica stationary phase and an acetonitrile-water mixture mobile phase, the sorption process of PEO to the stationary phase showed deltaH(o) > 0 and deltaS(o) > 0. Therefore, PEO retention in RPLC separation is an energetically unfavorable, entropy-driven process, which results in an increase of PEO retention as the temperature increases. In addition, at the enthalpy-entropy compensation point the elution volume of PEO was very different from the column void volume. These observations are quite different from the RPLC retention behavior of many organic polymers. The peculiar retention behavior of PEO in RPLC separation can be understood in terms of the hydrophobic interaction of this class of typical amphiphilic compounds with the non-polar stationary phase, on the one hand, and with the aqueous mobile phase, on the other. The entropy gain due to the release of the solvated water molecules from the PEO chain and the stationary phase is believed to be responsible for the entropy-driven separation process. On the other hand, in NPLC using an amino-bonded silica stationary phase and an acetonitrile-water mixture mobile phase, PEO showed normal enthalpy-driven retention behavior: deltaH(o) < 0 and deltaS(o) < 0, with the retention decreasing with increasing temperature and PEO eluting near the column void volume at the enthalpy-entropy compensation point. Therefore, high-resolution temperature gradient NPLC separation of high-molecular-mass PEO samples can be achieved with relative ease. The molecular mass distribution of high-molecular-mass PEO was found to be much narrower than that measured by size-exclusion chromatography.

Chromatography, Liquid↗

Retention mechanism of fatty alcohol ethoxylates in reversed-phase liquid chromatography.

Fatty alcohol ethoxylates (FAEs) are widely used nonionic surfactants that have distributions in both alkyl and poly(ethylene oxide) (PEO) chain length. Generally, two-dimensional liquid chromatography technique is required for the complete characterization of both distributions. By selecting a proper stationary and mobile phase condition, however, we can obtain fully resolved chromatograms of a FAE sample (Brij 30) with respect to both alkyl and PEO chain length by using a single reversed-phase C18 column and aqueous acetonitrile mobile phase. FAEs show a peculiar reversed-phase liquid chromatography (RPLC) retention behavior with an aqueous-organic mobile phase, the retention mechanism of which has not been fully elucidated. For a fixed alkyl chain length, FAEs with higher-molecular-mass PEO block elutes first and the van't Hoff plot of the retention factor shows a curvature. The unique retention behavior can be understood from the opposite thermodynamic characteristics associated with RPLC retention of PEO block and alkyl chain: the sorption process of PEO to the non-polar stationary phase shows deltaH(o) > 0 and deltaS(o) > 0 while the alkyl chain shows deltaH(o) < 0 and deltaS(o) < 0 in contrast. The relative magnitude of the two contributions can change the elution order of the FAE. Therefore the often found, inverted elution order of FAEs (the early elution of FAEs with longer PEO block) is due to the positive enthalpic interaction of PEO blocks, which is a characteristic of the hydrophobic interaction. And the curvature of the van't Hoff plots was analyzed assuming the temperature dependent thermodynamic variables.

Fatty Alcohols↗

Temperature gradient interaction chromatography and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis of air terminated polystyryllithium.

The reaction products of polystyryllithium with air were characterized by size-exclusion chromatography, temperature gradient interaction chromatography and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Polystyryllithium was prepared by anionic polymerization of styrene initiated with sec-butyllithium in cyclohexane under an Ar atmosphere. It was confirmed that polystyryl ketone, polystyryl alcohol, and directly coupled polystyrene were the major products in addition to the normally terminated polystyrene, which is consistent with the results in the literature. We could also identify the presence of methoxy and carboxylic acid end capped polystyrenes as well as dipolystyryl ether as minor products. Among the minor products, dipolystyryl ether has not been reported yet.

Air↗

Temperature gradient interaction chromatography and MALDI-TOF mass spectrometry analysis of stereoregular poly(ethyl methacrylate)s.

Temperature gradient interaction chromatography (TGIC) was applied for the separation of stereoregular poly(ethyl methacrylate) (PEMA) according to the tacticity. The three PEMA samples with differing tacticity (rr triad content 0, 53, and 91%) prepared by anionic polymerization were used. C18 bonded silica and a mixture of CH2Cl2 and CH3CN (30/70, v/v) were used as stationary and mobile phase, respectively. TGIC was able to separate the PEMA samples, showing the increasing retention in the order of decreasing rr triad contents; however TGIC elution peaks of the three PEMAs were not fully resolved but, rather, were partially overlapped. To isolate the tacticity effect from the molecular weight effect on the TGIC retention, the PEMA samples were fractionated by TGIC, and the accurate molecular weight of the fractions was determined by MALDI-TOF mass spectrometry. The fractions showed a much narrower molecular weight distribution than the mother PEMAs. The TGIC fractions of similar molecular weight but with different tacticity were fully resolved by TGIC, but mother PEMAs were not. These results indicate that the retention in TGIC is affected by both tacticity and molecular weight.

Journal Article↗