PubMed Health⌕ Search

Biomedical subjects

Dorothee Wistuba

Publications and source records attributed to Dorothee Wistuba.

9 recordsLinked to original sources

Stereoisomeric separation of flavanones and flavanone-7-O-glycosides by capillary electrophoresis and determination of interconversion barriers.

The stereoisomeric separation of several flavanones and flavanone-7-O-glycosides has been achieved with capillary electrophoresis by adding native cyclodextrins or cyclodextrin derivatives to the background electrolyte. As an alternative method, micellar electrokinetic chromatography with sodium cholate as a chiral surfactant has been used for the epimeric separation of two flavanone-7-O-glycosides. The effect of buffer systems containing mixtures of cyclodextrin with either sodium dodecyl sulfate or sodium cholate upon the chiral recognition of flavanones and flavanone-7-O-glycosides as well as the variation of the background electrolyte (concentration of buffer and surfactant, pH value, organic modifier), and its influence on the resolution factor Rs was investigated. Temperature- and pH-dependent enantiomerization or epimerization barriers of several flavanones (naringenin, homoeriodictyol) and flavanone-7-O-glycosides (naringin, neohesperidin, prunin, narirutin) in basic media (pH values of 9-11) have been observed. Interconversion profiles featuring characteristic plateau formation of the elution pattern were observed at high pH and evaluated with the simulation software ChromWin to determine rate constants k(T) and Eyring activation parameters, DeltaG#(T), DeltaH#, and DeltaS#.

Cyclodextrins↗

Delta-cyclodextrin as novel chiral probe for enantiomeric separation by electromigration methods.

Native delta-CD has been employed as chiral selector in CE and MEKC. To investigate the potential of the enantiodiscriminating properties of delta-CD, negatively charged 5-dimethylamino-1-naphthalene-sulfonyl (dansyl)-, 2,4-dinitrophenyl (DNP)- and FMOC-derivatives of several amino acids, 1,1'-binaphthyl-2,2'-diylhydrogenphosphate, flavanones and three positively charged drugs have been selected as testing samples. Enantioresolution factors up to 4.82 have been observed. The results were compared with those achieved by the conventional running buffer additives alpha-, beta- and gamma-CDs. For several examples a steady increase of enantioresolution with increasing degree of oligomerization has been detected.

Amino Acids↗

Comparison of monolithic approaches for enantioselective capillary electrochromatography involving cyclodextrins.

The access to CD-modified monoliths for enantiomeric separation by CEC can be divided into two main approaches. (i) Silica-based monoliths, prepared by either a sol-gel process or by sintering of silica particles, are modified after fabrication by coating with a CD selector. Alternatively the fusion of CD functionalized silica particle via gluing is feasible. (ii) Rigid or homogeneous organic polymer-based monoliths, prepared by polymerization of organic monomers in the presence of a porogen, are modified with the CD selector either by copolymerization or by physical incorporation into the continuous bed.

Journal Article↗

Enantiomeric separation by capillary electrochromatography using monolithic capillaries with sol-gel-glued cyclodextrin-modified silica particles.

By an on-column sol-gel process, a chiral monolithic stationary phase was prepared by the fusion of permethyl-beta-cyclodextrin-silica (Chira-Dex-silica) particles and by linking them to the internal capillary wall. The resulting monolith is stable toward voltage (30 kV) and pressure (300 bar) and possesses a high efficiency (up to 100,000 theoretical plates per meter). Efficient enantiomeric separation of various chiral compounds by pressure-supported capillary electrochromatography (CEC) was achieved. When comparing this method to capillary liquid chromatography (LC) employing the same column in an unified equipment, CEC shows a twofold higher column efficiency at comparable elution times and hence better resolution factors.

Chromatography, Micellar Electrokinetic Capillary↗

Fast enantiomeric separation with vancomycin as chiral additive by co-electroosmotic flow capillary electrophoresis: increase of the detection sensitivity by the partial filling technique.

A fast and sensitive method is described by using vancomycin as a chiral additive for enantiomeric separation by capillary electrophoresis (CE). In order to overcome disadvantages associated with use of vancomycin as chiral additive in CE, several strategies including the dynamic coating technique, the co-electroosmotic flow technique, and the partial filling technique were employed sequentially in this method. Using the polycationic polymer hexadimethrine bromide (HDB) as a buffer additive, the capillary wall was dynamically coated with a thin film formed by the adsorbed HDB. Consequently, the adsorption of vancomycin onto the capillary wall was minimized via electrostatic repulsion between the coating of the capillary wall and the vancomycin molecule. In addition, the reversed electroosmotic flow (from cathode to anode) produced by the positively charged capillary wall migrates in the same direction of negatively charged analytes (co-electroosmotic flow electrophoresis). Thereby the electrophoretic mobility of negatively charged analytes were drastically accelerated leading to a short separation time of less than 3.4 min. The separation time was further reduced by the use of a short-end-injection technique. For example, the analysis time was achieved by as short as 55 s for a baseline separation of dansyl-alpha-amino-n-butyric acid. Concurrently, the partial filling technique was used to avoid the loss of detection sensitivity caused by the presence of vancomycin in the running buffer. The effect of several parameters, such as HDB concentration, buffer pH, plug length of the chiral selector, concentration of the chiral selector and applied voltage, on enantioselectivity were investigated toward optimization. Besides the advantage of a very short separation time, the method is characterized by high detection sensitivity, high selectivity, and high efficiency.

Amino Acids↗

A silica monolithic column prepared by the sol-gel process for enantiomeric separation by capillary electrochromatography.

A method for the preparation of a silica monolithic capillary electrochromatography (CEC) column for the separation of enantiomers has been developed. The porous silica monolith was fabricated inside a fused-silica capillary column by using the sol-gel process. After gelation for 24 h, hydrothermal treatment at 100 degrees C for 24 h was performed to prevent the sol-gel matrix from cracking. The prepared monolith was then coated with Chirasil-beta-Dex which represents a chiral polymer prepared by grafting permethyl-beta-cyclodextrin to polymethylsiloxane with an octamethylene spacer. Immobilization of Chirasil-beta-Dex was performed by heat treatment at 120 degrees C for 48 h to give a nonextractable coating. The column performance was evaluated by using racemic hexobarbital as a model compound. The efficiency of 9.2 x 10(4) theoretical plates/m for the first eluted enantiomer of hexobarbital was obtained at an optimal flow rate of the mobile phase. The effect of mobile phase composition on enantiomeric separation of hexobarbital was also investigated. The column proved to be stable for more than one hundreds of runs during a two-months period. The enantiomers of several neutral and negatively charged chiral compounds were baseline separated on this column.

Chromatography, Micellar Electrokinetic Capillary↗

On-line coupling of packed capillary electrochromatography with coordination ion spray-mass spectrometry for the separation of enantiomers.

Pressure-supported packed capillary electrochromatography (CEC) and packed capillary high-performance liquid chromatography (pHPLC) have been coupled on-line to electrospray ionization-mass spectrometry (ESI-MS) and coordination ion spray-mass spectrometry (CIS-MS). Separation of enantiomers of barbiturates and chlorinated alkyl phenoxypropanoates were performed on a permethylated beta-cyclodextrin stationary phase by pressure-supported CEC. For on-line detection with ESI- and CIS-MS, a modified sheath-liquid interface was used. CIS-MS is a universal, novel ionization technique which improves the selectivity as well as the sensitivity. Charged complexes were formed through the addition of central complexing ions such as silver(I), cobalt(II), copper(II), and lithium(I) to the sheath flow. Advantages of CIS-MS detection compared to the ESI-MS mode are discussed. In the CIS-MS mode, increased sensitivity and high selectivity was attained through different possibilities of complexation. The superiority of pressure-supported CEC compared to pHPLC in the hyphenation with CIS-MS is demonstrated.

Barbiturates↗

Recent progress in enantiomeric separation by capillary electrochromatography.

Recent progress in enantiomeric separations by capillary electrochromatography (CEC) is reviewed. The development of simple and robust CEC column technologies plays an important role for popularization of CEC. During the last several years, various approaches for the preparation of enantioselective columns have been reported. Currently, the monolithic column technology (continuous beds) represents the most advanced approach for the preparation of CEC columns. The development of new chiral stationary phase used for CEC is another important issue in this field. Fundamental investigations on electrochromatographic behaviors of various CSPs are necessary in order to understand the separation mechanism and thus improve the separation performance. Some chiral stationary phases performed better under nonaqueous CEC conditions than reversed-phase conditions. Coupling CEC with mass spectrometry (MS) provides a powerful tool for enantiomeric separation. Finally, some applications of enantiomeric separation by CEC are summarized.

Chromatography↗