PubMed Health⌕ Search

Biomedical subjects

Dorte Xenia Gram

Publications and source records attributed to Dorte Xenia Gram.

2 recordsLinked to original sources

Using evolutionary information and ancestral sequences to understand the sequence-function relationship in GLP-1 agonists.

Glucagon-like peptide-1 (GLP-1) is an incretin hormone with therapeutic potential for type 2 diabetes. A variety of GLP-1 sequences are known from amphibian species, and some of these have been tested here and found to be able to bind and activate the human GLP-1 receptor. While little difference was observed for the in vitro potency for the human GLP-1 receptor, larger differences were found in the enzymatic stability of these peptides. Two peptides showed increased enzymatic stability, and they group together phylogenetically, though they originate from Amphibia and Reptilia. We have used ancestral sequence reconstruction to analyze the evolution of these GLP-1 molecules, including the synthesis of new peptides. We find that the increased stability could not be observed in the resurrected peptides from the common ancestor of frogs, even though they maintain the ability to activate the human GLP-1 receptor. Another method, using residue mapping on evolutionary branches yielded peptides that had maintained potency towards the receptor and also showed increased stability. This represents a new approach using evolutionary data in protein engineering.

Amino Acid Sequence↗

Study on biological variation of haemostatic parameters in clinically healthy dogs.

Thromboelastography (TEG) may be a valuable supplement to the coagulation assays activated partial thromboplastin time (aPTT), prothrombin time (PT), thrombin time (TT), fibrinogen, antithrombin (AT) and D-Dimer currently used in most clinical pathology laboratories. Allowable imprecision and bias reference limits for analytical tests can be calculated based on measurements of biological variation. No studies to date have examined the effect of biological variation on these haemostasis parameters in the same group of dogs. Plasma samples were collected after a set protocol once weekly for five consecutive weeks from eight healthy dogs (four males and four females) and stored at -80 degrees C until analysis. Randomized duplicate coagulation tests and TEG analyses were performed on all plasma samples within one run. The data were analyzed for outliers and subsequently subjected to nested analysis of variance to obtain the coefficient of analytical, intra-individual and inter-individual variation. From these objective analytical performance standards for imprecision, critical difference, total error and the index of individuality were calculated to assess the utility of conventional population-based reference ranges. All the clotting times (aPTT, PT and TT), fibrinogen, AT and D-Dimer showed a degree of individuality, which may make the use of population-based reference ranges alone an insensitive interpretation criterion, whereas a population-based reference interval seems to be sensitive for interpreting all TEG parameters. Analytical performance standards for imprecision were only met for one of the coagulation assays, whereas all TEG parameters except the alpha angle, alpha achieved this analytical goal.

Animals↗