PubMed Health⌕ Search

Biomedical subjects

Douglas C Noll

Publications and source records attributed to Douglas C Noll.

At least 19 recordsLinked to original sources

The Consortium for Clarity in ADRD Research Through Imaging (CLARiTI): Overview of consortium sites and anticipated enrollment.

INTRODUCTION: The Consortium for Clarity in Alzheimer's disease related dementias (ADRD) Research Through Imaging (CLARiTI) is a study that aims to collect standardized imaging and plasma biomarkers on 2000 Clinical Core participants enrolled across all Alzheimer's Disease Research Centers (ADRC) sites. We sought to summarize the known heterogeneity across centers regarding scientific focus and initial enrollment plans for CLARiTI. METHODS: We developed and distributed a survey capturing information on the 36 CLARiTI site's theme/expertise, recruitment plans, and the intersection of CLARiTI with other ADRC imaging efforts. RESULTS: Anticipated CLARiTI enrollees spanned 11 different categories of suspected etiologies underlying impairment. A wide range of risk factors were endorsed across sites regarding the enrollment of unimpaired individuals. Variability also existed regarding site-level strategies in enrollment into CLARiTI versus other imaging efforts. DISCUSSION: We anticipate that the 2000 individuals that will enroll into CLARiTI will reflect the clinical heterogeneity already in place across the ADRC network. HIGHLIGHTS: The ADRC Consortium for Clarity in ADRD Research Through Imaging (CLARiTI) will leverage and contribute to the existing Alzheimer's Disease Research Centers (ADRC) program by supporting standardized imaging and plasma collection across all centers. We summarize the variation in scientific focus and enrollment plans across ADRC sites participating in CLARiTI. The anticipated CLARiTI cohort will reflect the clinical heterogeneity that already exists across the ADRC network. CLARiTI will contribute to scientific goals related to the detection of multi-etiological signatures relevant for Alzheimer's disease and related disorders (ADRDs).

Humans↗

Vascular dynamics and BOLD fMRI: CBF level effects and analysis considerations.

Changes in the cerebral blood flow (CBF) baseline produce significant changes to the hemodynamic response. This work shows that increases in the baseline blood flow level produce blood oxygenation-level dependent (BOLD) and blood flow responses that are slower and lower in amplitude, while decreases in the baseline blood flow level produce faster and higher amplitude hemodynamic responses. This effect was characterized using a vascular model of the hemodynamic response that separated arterial blood flow response from the venous blood volume response and linked the input stimulus to the vascular response. The model predicted the baseline blood flow level effects to be dominated by changes in the arterial vasculature. Specifically, it predicted changes in the arterial blood flow time constant and venous blood volume time constant parameters of +294% and -24%, respectively, for a 27% increase in the baseline blood flow. The vascular model performance was compared to an empirical model of the hemodynamic response. The vascular and empirical hemodynamic models captured most of the baseline blood flow level effects observed and can be used to correct for these effects in fMRI data. While the empirical hemodynamic model is easy to implement, it did not incorporate any explicit physiological information.

Algorithms↗

Application of selective saturation to image the dynamics of arterial blood flow during brain activation using magnetic resonance imaging.

A saturation-based approach is proposed to image the arterial blood flow signal with temporal resolution of 1 to 2 s and in-plane spatial resolution of a few millimeters. Using a saturation approach to suppress the undesired background stationary signal allows the blood water that enters the slice to be imaged at some specified later time. Since the blood protons that are being imaged are not restricted to the intravascular space, this technique is also sensitive to tissue perfusion signal contributions. The signal uptake characteristics of the saturation method proposed were used to study the different signal contributions as a function of the acquisition parameters. A typical perfusion acquisition (FAIR) was also used for comparison. The proposed method was demonstrated in a functional motor activation experiment and the observed signal changes were smaller than those obtained using the FAIR acquisition. The dynamics of the saturation method and FAIR temporal signal changes were investigated and time constants between 2 and 44 s were estimated. The tissue signal contribution to the saturation method's signal was small over the range of acquisition parameters that sensitized it to the arterial compartment.

Cerebrovascular Circulation↗

Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity.

This article presents a small-flip-angle, three-dimensional tailored RF pulse that excites thin slices with an adjustable quadratic in-plane spatial variation. The quadratic spatial variation helps to compensate for the loss in image uniformity using a volume coil at 3 T due to the wavelike properties of the RF field. The pulse is based on a novel "fast-kz" design that uses a series of slice-select subpulses along kz and phase encoding "blips" along kx-ky. The method is demonstrated by acquiring a series of 5-mm-thick T2-weighted images of the human brain at 3 T using pulses 4.8 ms in length with a 45 degrees flip angle.

Brain Mapping↗

Spatial domain method for the design of RF pulses in multicoil parallel excitation.

Parallel excitation has been introduced as a means of accelerating multidimensional, spatially-selective excitation using multiple transmit coils, each driven by a unique RF pulse. Previous approaches to RF pulse design in parallel excitation were either formulated in the frequency domain or restricted to echo-planar trajectories, or both. This paper presents an approach that is formulated as a quadratic optimization problem in the spatial domain and allows the use of arbitrary k-space trajectories. Compared to frequency domain approaches, the new design method has some important advantages. It allows for the specification of a region of interest (ROI), which improves excitation accuracy at high speedup factors. It allows for magnetic field inhomogeneity compensation during excitation. Regularization may be used to control integrated and peak pulse power. The effects of Bloch equation nonlinearity on the large-tip-angle excitation error of RF pulses designed with the method are investigated, and the utility of Tikhonov regularization in mitigating this error is demonstrated.

Algorithms↗

Excitation UNFOLD (XUNFOLD) to improve the temporal resolution of multishot tailored RF pulses.

An extension of the "UNaliasing by Fourier encoding the Overlaps using the temporaL Dimension" (UNFOLD) method to the excitation domain (XUNFOLD) is presented to improve the temporal resolution of multishot tailored RF (TRF) pulses. Multishot three-dimensional TRF pulses were designed to produce a time series of images with periodically aliased excitation profiles. The XUNFOLD method is shown to remove the excitation profile aliasing from the dynamic imaging data by filtering in the temporal frequency dimension. The technique is demonstrated to improve the temporal resolution of simulated functional MRI (fMRI) activation in a time series of brain images.

Algorithms↗

Magnetic resonance compatibility of multichannel silicon microelectrode systems for neural recording and stimulation: design criteria, tests, and recommendations.

Magnetic resonance (MR) compatibility of biomedical implants and devices represents a challenge for designers and potential risks for users. This paper addresses these problems and presents the first MR-compatible multichannel silicon chronic microelectrode system, used for recording and electrical stimulation of the central nervous system for animal models. A standard chronic assembly, from the Center for Neural Communication Technology at the University of Michigan, was tested on a 2 Tesla magnet to detect forces, heating, and image distortions, and modified to minimize or eliminate susceptibility artifacts, tissue damage, and electrode displacement, maintaining good image quality and safety to the animals. Multiple commercial connectors were tested for MR compatibility and several options for the reference electrode were also tested to minimize image artifacts and provide a stable biocompatible reference for shortand long-term neural recordings. Different holding screws were tested to anchor the microelectrode assembly on the top of the skull. The final selection of this part was based on MR-compatibility, biocompatibility, durability, and mechanical and chemical stability. The required adaptor to interconnect the MR-compatible microelectrode with standard data acquisition systems was also designed and fabricated. The final design is fully MR-compatible and has been successfully tested on guinea pigs.

Animals↗

Accounting for nonlinear BOLD effects in fMRI: parameter estimates and a model for prediction in rapid event-related studies.

Nonlinear effects in fMRI BOLD data may substantially influence estimates of task-related activations, particularly in rapid event-related designs. If the BOLD response to each stimulus is assumed to be independent of the stimulation history, nonlinear interactions create a prediction error that may reduce sensitivity. When stimulus density differs among conditions, nonlinear effects can cause artifactual differences in activation. This situation can occur in rapid event-related designs or when comparing blocks of unequal lengths. We present data showing substantial nonlinear history effects for stimuli 1 s apart and use estimates of nonlinearities in response magnitude, onset time, and time to peak to form a low-dimensional parameterization of these nonlinear effects. Our estimates of nonlinearity appear relatively consistent throughout the brain, and these estimates can be used to form adjusted linear predictors for future rapid event-related fMRI studies. Adjusting the linear model for these known nonlinear effects results in a substantially better model fit. The biggest advantages to using predictors adjusted for known nonlinear effects are (1) higher sensitivity at the individual subject level of analysis, (2) better control of confounds related to nonlinear effects, and (3) more accurate estimates of design efficiency in experimental fMRI design.

Adolescent↗

Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.

This work presents a small tip-angle 3D tailored RF slab-select pulse for reducing the B1 field inhomogeneity at 3T. The compensated slice profile was determined from a B1 inhomogeneity map. SNR improvement and degree of artifact reduction were evaluated in a NiCl2 doped phantom and human brains. The technique was found to reduce inhomogeneities as large as 30% of the peak image magnitude in all three spatial directions in the brain using a standard head coil.

Algorithms↗

Quantification of perfusion fMRI using a numerical model of arterial spin labeling that accounts for dynamic transit time effects.

A new approach to modeling the signal observed in arterial spin labeling (ASL) experiments during changing perfusion conditions is presented in this article. The new model uses numerical methods to extend first-order kinetic principles to include the changes in arrival time of the arterial tag that occur during neuronal activation. Estimation of the perfusion function from the ASL signal using this model is also demonstrated. The estimation algorithm uses a roughness penalty as well as prior information. The approach is demonstrated in numerical simulations and human experiments. The approach presented here is particularly suitable for fast ASL acquisition schemes, such as turbo continuous ASL (Turbo-CASL), which allows subtraction pairs to be acquired in less than 3 s but is sensitive to arrival time changes. This modeling approach can also be extended to other acquisition schemes.

Algorithms↗

Iterative RF pulse design for multidimensional, small-tip-angle selective excitation.

The excitation k-space perspective on small-tip-angle selective excitation has facilitated RF pulse designs in a range of MR applications. In this paper, k-space-based design of multidimensional RF pulses is formulated as a quadratic optimization problem, and solved efficiently by the iterative conjugate-gradient (CG) algorithm. Compared to conventional design approaches, such as the conjugate-phase (CP) method, the new design approach is beneficial in several regards. It generally produces more accurate excitation patterns. The improvement is particularly significant when k-space is undersampled, and it can potentially shorten pulse lengths. A prominent improvement in accuracy is also observed when large off-resonance gradients are present. A further boost in excitation accuracy can be accomplished in regions of interest (ROIs) if they are specified together with "don't-care" regions. The density compensation function (DCF) is no longer required. In addition, regularization techniques allow control over integrated and peak pulse power.

Algorithms↗

Conjugate phase MRI reconstruction with spatially variant sample density correction.

A new image reconstruction method to correct for the effects of magnetic field inhomogeneity in non-Cartesian sampled magnetic resonance imaging (MRI) is proposed. The conjugate phase reconstruction method, which corrects for phase accumulation due to applied gradients and magnetic field inhomogeneity, has been commonly used for this case. This can lead to incomplete correction, in part, due to the presence of gradients in the field inhomogeneity function. Based on local distortions to the k-space trajectory from these gradients, a spatially variant sample density compensation function is introduced as part of the conjugate phase reconstruction. This method was applied to both simulated and experimental spiral imaging data and shown to produce more accurate image reconstructions. Two approaches for fast implementation that allow the use of fast Fourier transforms are also described. The proposed method is shown to produce fast and accurate image reconstructions for spiral sampled MRI.

Algorithms↗

Fast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil system.

A fast, two-coil, pseudo-continuous labeling scheme is presented. This new scheme permits the collection of a multislice subtraction pair in <3 s, depending on the subject's arterial transit times. The method consists of acquiring both control and tag images immediately after a labeling period that matches the arterial transit time. The theoretical basis of the technique, and simulations of the signal during changes in both transit time and perfusion are presented. Experimental data from functional imaging experiments were collected to demonstrate the technique and its characteristics.

Blood Flow Velocity↗

Dynamic field map estimation using a spiral-in/spiral-out acquisition.

The long readout times of single-shot acquisitions and the high field strengths desired for functional MRI (fMRI) using blood oxygenation level-dependent (BOLD) contrast make functional scans sensitive to magnetic field inhomogeneity. If it is not corrected during image reconstruction, field inhomogeneity can cause geometric distortions in the images when Cartesian k-space trajectories are used or blurring with spiral acquisitions. Many traditional methods to correct for field inhomogeneity distortions rely on a static field map measured with the use of images that are themselves distorted. In this work, we employ a regularized least-squares approach to jointly estimate both the undistorted image and field map at each acquisition using a spiral-in/spiral-out pulse sequence. Simulation and phantom studies show that this method is accurate and stable over a time series. Human functional studies show that the jointly estimated field map may be more accurate than standard field map estimates in the presence of respiration-induced phase oscillations, leading to better detection of functional activation. The proposed method measures a dynamic field map that accurately tracks magnetic field drift and respiration-induced phase oscillations during the course of a functional study.

Brain↗

Working memory for complex scenes: age differences in frontal and hippocampal activations.

Age differences in frontal and hippocampal activations in working memory were investigated during a maintenance and subsequent probe interval in an event-related fMRI design. Younger and older adults either viewed or maintained photographs of real-world scenes (extended visual or maintenance conditions) over a 4-sec interval before responding to a probe fragment from the studied picture. Behavioral accuracy was largely equivalent across age and conditions on the probe task, but underlying neural activations differed. Younger but not older adults showed increased left anterior hippocampal activations in the extended visual compared with the maintenance condition. On the subsequent probe interval, however, older adults showed more left and right inferior frontal activations than younger adults. The increased frontal activations at probe in older adults may have been compensatory for the decreased hippocampal activations during maintenance, but alternatively could have reflected the increased difficulty of the probe task for the older subjects. Thus, we demonstrate qualitatively different engagement of both frontal and hippocampal structures in older adults in a working memory task, despite behavioral equivalence.

Adult↗

Activation of the medial prefrontal cortex and extended amygdala by individual ratings of emotional arousal: a fMRI study.

BACKGROUND: Significant differences between individual responses to emotional stimuli can be important for the study of emotion. We investigated whether incorporating individual ratings of emotional arousal in the analysis of functional magnetic resonance imaging (fMRI) data improves the detection of activation in the medial prefrontal cortex (MPFC) and sublenticular extended amygdala (SLEA), areas implicated in the processing of emotional salience. METHODS: Healthy subjects viewed counterbalanced blocks of aversive, nonaversive, and blank images. Outside the scanner, they rated the intensity of emotional arousal (salience) of each presented picture. RESULTS: Incorporating the subject's response to each stimulus by using individualized regressors produced more robust activations within MPFC and SLEA compared with a simple boxcar regressor, identical for all subjects. CONCLUSIONS: Our findings demonstrate that individual behavioral data are useful in improving detection of activation in block-design functional imaging studies.

Adult↗

Prefrontal cortex dysfunction mediates deficits in working memory and prepotent responding in schizophrenia.

BACKGROUND: Schizophrenic patients show deficits in working memory (WM) and inhibition of prepotent responses. We examined brain activity while subjects performed tasks that placed demands on WM and overriding prepotent response tendencies, testing predictions that both processes engage overlapping prefrontal cortical (PFC) regions and that schizophrenic patients show reduced PFC activity and performance deficits reflecting both processes. METHODS: Functional magnetic resonance imaging data were acquired while 16 schizophrenic and 15 healthy subjects performed the N-Back task that varied WM load and a version of the AX-CPT that required overriding a prepotent response tendency. RESULTS: Both tasks engaged overlapping cortical networks (e.g., bilateral dorsolateral PFC, Broca's area, parietal cortex). Increased WM load monotonically increased activity; preparation to override a prepotent response produced greater and more enduring activity. Group differences on each task emerged in a right dorsolateral PFC region: schizophrenic subjects showed lesser magnitude increases under conditions of high WM and prepotent response override demands, with concomitant performance impairments. CONCLUSIONS: Schizophrenic patients exhibit PFC-mediated deficits in WM and preparation to override prepotent responses. Findings are consistent with the operation of a single underlying PFC-mediated cognitive control mechanism and with physiologic dysfunction of the dorsolateral PFC in schizophrenic patients reflecting impairments in this mechanism.

Adult↗

Detecting low-frequency functional connectivity in fMRI using a self-organizing map (SOM) algorithm.

Low-frequency oscillations (<0.08 Hz) have been detected in functional MRI studies, and appear to be synchronized between functionally related areas. A current challenge is to detect these patterns without using an external reference. Self-organizing maps (SOMs) offer a way to automatically group data without requiring a user-biased reference function or region of interest. Resting state functional MRI data was classified using a self-organizing map (SOM). Functional connectivity between the left and right motor cortices was detected in five subjects, and was comparable to results from a reference-based approach. SOMs are shown to be an attractive option in detecting functional connectivity using a model-free approach. Hum. Brain Mapping 20:220-226, 2003.

Algorithms↗