Phrenic nerve injury after atrial fibrillation catheter ablation: characterization and outcome in a multicenter study.

OBJECTIVES: The purpose of this study was to characterize the occurrence of phrenic nerve injury (PNI) and its outcome after radiofrequency (RF) ablation of atrial fibrillation (AF). BACKGROUND: It is recognized that extra-myocardial damage may develop owing to penetration of ablative energy. METHODS: Between 1997 and 2004, 3,755 consecutive patients underwent AF ablation at five centers. Among them, 18 patients (0.48%; 9 male, 54 +/- 10 years) had PNI (16 right, 2 left). The procedure consisted of pulmonary vein (PV) isolation in 15 patients and anatomic circumferential ablation in 3 patients, with additional left atrial lesions (n = 11) and/or superior vena cava (SVC) disconnection (n = 4). RESULTS: Right PNI occurred during ablation of right superior PV (n = 12) or SVC disconnection (n = 3). Left PNI occurred during ablation at the left atrial appendage. Immediate features were dyspnea, cough, hiccup, and/or sudden diaphragmatic elevation in 9, and in the remaining the diagnosis was made after ablation owing to dyspnea (n = 7) or on routine radiographic evaluation (n = 2). Four patients (22%) were asymptomatic. Complete recovery occurred in 12 patients (66%). Recovery occurred within 24 h in the two patients with left PNI and in one patient with right PNI occurring with SVC disconnection. In the other nine patients, right PNI recovery occurred after 4 +/- 5 months (1 to 12 months) with respiratory rehabilitation. After a mean follow-up of 36 +/- 33 months, six patients have persistent PNI (three with partial and three with no recovery). CONCLUSIONS: In this multicenter experience, PNI was a rare complication (0.48%) of AF ablation. Ablation of the right superior PV, SVC, and left atrial appendage were associated with PNI. Complete (66%) or partial (17%) recovery was observed in the majority.

Adult↗

Impact of transforming growth factor-beta1 on atrioventricular node conduction modification by injected autologous fibroblasts in the canine heart.

BACKGROUND: Atrioventricular (AV) nodal ablation for management of atrial fibrillation (AF) is irreversible and requires permanent pacemaker implantation. We hypothesized that as an alternative, implantation of autologous fibroblasts in the perinodal region would focally modify AV nodal conduction and that this modulation would be enhanced by pretreatment with transforming growth factor-beta1 (TGF-beta1), a stimulant of fibroblasts. METHODS AND RESULTS: Skin biopsies were taken from 12 mongrel dogs, and derived fibroblasts were dissociated and grown in culture for 2 weeks. Multiple injections (0.25 mL) were made through an 8F NOGA catheter along the fast/slow AV nodal pathways as guided by an electroanatomic mapping system. Seven dogs received fibroblasts alone (1x10(6) cells/mL), 7 dogs received TGF-beta1 (5 microg), 4 dogs received fibroblasts and TGF-beta1 (1x10(6) cells/mL+5 microg), and 4 dogs received saline only. AV node function was assessed at baseline and after 4 weeks. Saline (80 mL) with assigned therapy (0.25 mL per injection) was injected into the peri-AV nodal region in each dog. At baseline, the AH interval (66+/-3 ms) and the average RR interval (331+/-17 ms) in pacing-induced AF were similar in each cohort. The increase in AH interval in normal sinus rhythm was longer after fibroblast (23+/-4 versus 5+/-5 ms; P=0.05) and fibroblast plus TGF-beta1 (50+/-5 versus 5+/-5 ms; P<0.001) injections than with saline alone, with similar findings during high right atrium and distal coronary sinus pacing. The AH interval was not significantly increased after TGF-beta1 injections. The AH interval was significantly longer after fibroblast plus TGF-beta1 injections than with either therapy (TGF-beta1 or fibroblasts) alone. The RR interval during AF was increased in dogs that received fibroblasts alone (110+/-36 versus -41+/-34 ms) and to a greater extent with the addition of TGF-beta1 (294+/-108 versus -41+/-34 ms). No AV block was seen in any cohort at 4 weeks. Labeled fibroblasts that expressed vimentin were identified in all dogs that received cell injections at 4 weeks. CONCLUSIONS: AV nodal modification can be achieved with injected fibroblasts without the creation of AV block. The effect on AV node conduction is substantially enhanced by pretreatment of fibroblasts with TGF-beta1. These data have therapeutic potential for the management of rapid ventricular rate during AF without pacemaker implantation.

Animals↗

Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system.

OBJECTIVES: We sought to evaluate the efficacy and safety of a novel cryothermal balloon ablation system in creating pulmonary vein (PV) isolation. BACKGROUND: Pulmonary vein isolation using standard radiofrequency ablation techniques is limited by procedure-related complications, such as thrombus formation and PV stenosis. Cryothermal ablation may reduce the risk of such complications. METHODS: Eight dogs underwent circumferential ablation of both superior PVs for either 4 or 8 min using a cryothermal balloon catheter (CryoCath Technologies Inc., Kirkland, Canada). Both fluoroscopy and intracardiac ultrasound (ICE)-guided balloon and Lasso catheter positioning at the PV ostia assessed short-term PV integrity. In six additional dogs, long-term PV integrity was assessed by computed tomography at 16 weeks after ablation. RESULTS: Successful electrical isolation was achieved acutely in 14 of 16 (87.5%) PVs and was confirmed in one-week survival studies in 10 of 12 (83%) PVs. Successful isolation was higher in the absence of any peri-balloon flow leak as seen by ICE (p = 0.015), and with balloon temperatures < or =-80 degrees C (p = 0.015). Cryolesions were located at the veno-atrial junction and were homogeneous, with intact endothelium and free of thrombus formation. Although limited angiographic PV narrowing was noted in the early follow-up period, no significant PV narrowing was seen long-term. Right phrenic nerve injury was seen in 50% of the animals studied at one week. CONCLUSIONS: This novel cryothermal balloon ablation system is effective for isolating PVs, but injury to the right phrenic nerve was noted in this early experience. Further studies are needed to assess the long-term efficacy and safety of this technique.

Animals↗

Discrepancies between catheter tip and tissue temperature in cooled-tip ablation: relevance to guiding left atrial ablation.

BACKGROUND: It is not known whether catheter tip temperatures with a cooled-tip ablation can be reliably extrapolated to estimate actual tissue temperatures. The relationship between catheter tip temperatures, tissue temperatures, power, and microbubble formation is not known. METHODS AND RESULTS: Nine dogs underwent 111 radiofrequency energy deliveries at the pulmonary vein ostia with a cooled-tip catheter. Catheter tip and tissue temperatures were markedly discrepant. Catheter tip temperature plateaus at 36 degrees C to 39 degrees C with increasing power, whereas tissue temperature increases to a mean of 75+/-3 degrees C at 45 W (maximum temperature >100 degrees C). Seventy-two energy deliveries were performed, titrating power to microbubble formation guided by intracardiac echocardiography. Type I and II microbubble formation occurred in 45 (63%) and 19 (26%) ablations, respectively. Type I microbubble emergence occurred at lower powers (21+/-8 versus 26+/-4 W; P=0.05), catheter tip temperatures (38+/-5 degrees C versus 48+/-10 degrees C; P=0.02), and tissue temperatures (65+/-19 degrees C versus 81+/-9 degrees C; P<0.001) than type II microbubble formation. Maximum impedance decreases during ablation before microbubble formation were less with type I microbubble (20+/-9 versus 37+/-11 Omega; P<0.001) compared with type II microbubbles. One quarter of type I microbubbles abruptly transitioned to type II microbubbles with significant changes in power or catheter tip temperature. No microbubbles were seen in 19 ablations (26%) despite powers up to 26+/-9 W and tissue temperatures up to 81+/-17 degrees C. CONCLUSIONS: Catheter tip and tissue temperatures are markedly discrepant during cooled-tip ablation. Type I and II microbubble formation occurs at overlapping power and catheter tip and tissue temperature ranges. Neither the absence of microbubbles nor the presence of type I microbubble formation ensures against excessive tissue heating. The appearance of microbubbles may indicate possible tissue overheating and signal a need to decrease energy.

Animals↗

Clinical presentation, investigation, and management of pulmonary vein stenosis complicating ablation for atrial fibrillation.

BACKGROUND: Although segmental or circumferential ablation is effective in eliminating pulmonary vein (PV)-mediated atrial fibrillation (AF), this procedure may be complicated by the occurrence of PV stenosis. METHODS AND RESULTS: To establish the clinical presentation, diagnostic manifestations, and interventional management of PV stenosis, 23 patients with stenosis of 34 veins complicating ablation of AF were evaluated. Each patient became symptomatic 103+/-100 days after undergoing ablation. In 8 veins, the ablation producing the PV stenosis was a repeated procedure for continued AF. Nineteen patients presented with dyspnea on exertion, 7 with dyspnea at rest, 9 with cough, and 6 with chest pain. On multirow spiral computed tomography examination, the narrowest lumen of the affected PVs measured 3+/-2 mm compared with 13+/-3 mm at baseline (P< or =0.001). The relative perfusion of affected lung segments on isotope scans was reduced to 4+/-3% of total perfusion compared with 22+/-10% in unaffected segments. At percutaneous intervention, these veins showed 80+/-13% stenosis, with a mean gradient of 12+/-5 mm Hg. This was significantly reduced to a residual stenosis of 9+/-8% (P< or =0.001) and a residual gradient of 3+/-4 mm Hg (P< or =0.001). Twenty veins were treated with balloon dilatation alone, whereas 14 veins were stented with standard 10-mm-diameter bare-metal stents. Although the symptomatic response was nearly immediate and impressive, 14 patients developed in-stent or in-segment restenosis, requiring repeated interventions in 13. CONCLUSIONS: Percutaneous intervention produces rapid and dramatic symptom relief in patients with highly symptomatic PV stenosis after radiofrequency ablation for AF. Nevertheless, alternative treatment methods will be required to decrease recurrent in-stent or in-segment restenosis.

Adult↗

Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.

BACKGROUND: Sudden death from cardiac causes remains a leading cause of death among patients with congestive heart failure (CHF). Treatment with amiodarone or an implantable cardioverter-defibrillator (ICD) has been proposed to improve the prognosis in such patients. METHODS: We randomly assigned 2521 patients with New York Heart Association (NYHA) class II or III CHF and a left ventricular ejection fraction (LVEF) of 35 percent or less to conventional therapy for CHF plus placebo (847 patients), conventional therapy plus amiodarone (845 patients), or conventional therapy plus a conservatively programmed, shock-only, single-lead ICD (829 patients). Placebo and amiodarone were administered in a double-blind fashion. The primary end point was death from any cause. RESULTS: The median LVEF in patients was 25 percent; 70 percent were in NYHA class II, and 30 percent were in class III CHF. The cause of CHF was ischemic in 52 percent and nonischemic in 48 percent. The median follow-up was 45.5 months. There were 244 deaths (29 percent) in the placebo group, 240 (28 percent) in the amiodarone group, and 182 (22 percent) in the ICD group. As compared with placebo, amiodarone was associated with a similar risk of death (hazard ratio, 1.06; 97.5 percent confidence interval, 0.86 to 1.30; P=0.53) and ICD therapy was associated with a decreased risk of death of 23 percent (0.77; 97.5 percent confidence interval, 0.62 to 0.96; P=0.007) and an absolute decrease in mortality of 7.2 percentage points after five years in the overall population. Results did not vary according to either ischemic or nonischemic causes of CHF, but they did vary according to the NYHA class. CONCLUSIONS: In patients with NYHA class II or III CHF and LVEF of 35 percent or less, amiodarone has no favorable effect on survival, whereas single-lead, shock-only ICD therapy reduces overall mortality by 23 percent.

Aged↗

Sex differences in outcome after ventricular fibrillation in out-of-hospital cardiac arrest.

INTRODUCTION: Previous studies have shown that early defibrillation programs improve survival after an out-of-hospital cardiac arrest (OHCA). Reports also suggest that women fare worse than men do after cardiovascular events, but there is no population-based study of sex differences after an OHCA with early defibrillation. We, therefore, compared the short- and long-term survival and quality-of-life (QOL) in women and men after an OHCA. METHODS: All patients with a ventricular fibrillation (VF) OHCA who received early defibrillation in Olmstead County, Minnesota between November 1990 and December 2000 were included. Using medical records and the cardiac arrest database, the short- and long-term survival and QOL based on a SF-36 survey of each sex were compared. Adjusted QOL scores were obtained by using age- and sex-specific norms from a sample of the general U.S. population; an adjusted score of 50 (normalized mean) was considered normal. RESULTS: Thirty-seven female and 163 male patients presented with a VF OHCA and early defibrillation. Survival to hospital admission was significantly better for women than men [30 female survivors to admission (81%), 112 male (69%), p = 0.04]. Paradoxically, survival to discharge among those admitted was worse for women [13 female survivors to discharge (43%), 66 male (61%), p = 0.04]. The average length of follow-up was 4.8+/-3.0 years. The 5-year expected survival was 83% in women and 78% in men (p = 0.48). There was no difference in call-to-shock time (6+/-2, 6+/-2 min, p = 0.6) or whether the arrest was witnessed (86, 82%, p = 0.64). There was no statistical difference between women and men in age (64+/-17, 65+/-14 years), ejection fraction (40+/-17, 40+/-18%), diabetes (17, 29%, p = 0.16), hypertension (23, 28%, p = 0.58) or known CAD (27, 48%, p = 0.06). Adjusted QOL scores were similar between women and men in terms of pain (52+/-9, 52+/-10) vitality (47+/-11, 40+/-9), general health (49+/-9, 44+/-7), social function (51+/-10, 51+/-8), and mental health (50+/-10, 49+/-6). CONCLUSION: Women are more likely to survive to hospital admission following an OHCA. However, admitted women less likely to survive their hospital stay. Long-term survival and QOL are equally favorable in both sexes.

Aged↗

Use of advanced mapping systems to guide ablation in complex cases: experience with noncontact mapping and electroanatomic mapping systems.

OBJECTIVE: This report describes our experience with noncontact mapping and electroanatomic mapping in complex ablations, which are defined as ablations done after failure of conventional ablation. MATERIAL AND METHODS: Patients were included (N = 68; 49% with structural heart disease) in whom previous ablation failed and in whom a second procedure was done with advanced mapping. Non-contact mapping was used in 17 patients, electroanatomic mapping in 36, and both noncontact and electroanatomic mapping in 15. Arrhythmias included focal atrial tachycardia (n = 16), reentrant atrial tachycardia (n = 14), right ventricular outflow tachycardia (n = 10), post-myocardial infarction ventricular tachycardia (n = 9), and others (n = 19). RESULTS: Acute success at the second ablation was achieved in 79% of patients. At 20 +/- 9 months after the procedure, 69% of these patients reported having significantly fewer symptoms than before the second ablation, and 51% were free of symptoms. Only 16% were using antiarrhythmic medications. Complications included a small pericardial effusion in two patients, hypotension in one patient, and a femoral pseudoaneurysm in another. CONCLUSIONS: Advanced mapping is a useful and safe adjunct for catheter ablation after ablation has failed in patients with complex substrate.

Arrhythmias, Cardiac↗

Mechanisms of phrenic nerve injury during radiofrequency ablation at the pulmonary vein orifice.

BACKGROUND: The phrenic nerve can be injured with radiofrequency energy delivery. Nevertheless, the mechanisms of injury are unknown. This study was undertaken to examine phrenic nerve tissue temperatures during ablation at the pulmonary vein (PV) orifice, assess the temperature dependence of injury, and to delineate the possible mechanisms of untoward nerve effects. METHODS: Ten dogs underwent ablation at the right superior PV (RSPV) orifice. Phrenic nerve temperatures were assessed with implanted thermocouples overlying the endocardial ablation site. Using an 8-mm ablation catheter tip, energy was titrated to 50 degrees C and incremented by 5 degrees C for 120 seconds. RESULTS: Phrenic nerve capture was achieved in nine (90%) dogs after thermocouple implantation. A RSPV orifice tissue temperature >60 degrees C occurred in 32 (84%) of energy deliveries with a power of 34 +/- 22 W. In three (33%) dogs, this resulted in nerve dysfunction (maximum nerve temperature: 41 degrees C, 41 degrees C, and 91 degrees C) with histology consistent with acute thermal injury. In four additional dogs, 17 energy deliveries were made directly to the phrenic nerve using a novel in situ model. In 5 (29%) energy deliveries, nerve function was impacted immediately by the generated current, with resolution simultaneous with discontinuing radiofrequency. Transient phrenic nerve injury occurred in all dogs at a temperature of 47 +/- 3 degrees C (range: 43-53 degrees C) after 38 +/- 32 seconds (range: 20-120 seconds). After termination of the energy delivery, nerve function returned in 15(88%) during 30 seconds of postablation pacing. In two (12%) ablation attempts, nerve recovery was delayed (>3 minutes). Permanent injury occurred in all dogs after 92 +/- 83 seconds (range: 20-280 seconds) of additional energy delivery at a temperature of 51 +/- 6 degrees C (range: 45-65 degrees C). CONCLUSION: Phrenic nerve injury can be more common than anticipated with RF ablation at the RSPV orifice. Relatively low tissue temperatures can injure the nerve. Immediate nerve effects suggest a second mechanism of nerve dysfunction related to electrical current. Transient nerve effects occur prior to permanent damage, providing an opportunity to discontinue energy delivery before permanent injury.

Animals↗

Creating continuous linear lesions in the atria: a comparison of the multipolar ablation technique versus the conventional drag-and-burn.

INTRODUCTION: Catheter-based treatment of atrial fibrillation (AF) requires the isolation of the triggering foci as well as modification of the atria with substrate that sustains AF. The creation of linear lesions in the left atrium with standard radiofrequency ablative methods requires long procedural times with unpredictable results. METHODS: The simultaneous delivery of phase-shifted radiofrequency energy from a multipolar catheter was compared to the conventional drag-and-burn technique for creating linear lesions in 10 dogs. Four atrial sites were targeted under intracardiac ultrasound and fluoroscopic guidance in each of 10 dogs. The conventional drag-and-burn technique or the multipolar phase-shifted ablation catheter was randomly applied for 60 seconds and compared. RESULTS: Creating linear lesions using the simultaneous multipolar phase-shifted ablation catheter was on average 11.0 minutes faster (33.6 minutes vs 44.6 minutes, P < 0.01) than the drag-and-burn method. The fraction of the lesion length achieved using phase-shifted ablation compared to that intended was 23% greater (76% vs 53%, P < 0.01), and has less discontinuities (0.1 compared to 0.8 discontinuities/line, P < 0.003). There was no significant difference in either the lesion transmurality, or fluoroscopy times. CONCLUSION: The simultaneous delivery of phase-shifted, radiofrequency energy using a multipolar catheter is more effective and efficient in producing linear lesions than the traditional drag-and-burn technique. Using the multipolar ablative method to create linear lesions may be a useful technique in the treatment of patients with substrate-mediated atrial fibrillation.

Animals↗

Outcomes after cardiac perforation during radiofrequency ablation of the atrium.

BACKGROUND: Perforation during catheter procedures in either the atrium or ventricle is relatively uncommon, but potentially fatal if tamponade ensues. This study analyzes the occurrence and outcomes of cardiac perforation during catheter-based radiofrequency ablation procedures in the left atrium. METHODS: All patients with a periprocedure perforation who have undergone radiofrequency ablation for atrial fibrillation (AF) or tachycardia were included. RESULTS: Of 632 procedures performed from January 1999 to October 2004, 15 (2.4%) were complicated by perforation requiring pericardiocentesis. The perforation site was left atrium in 9 (60.0%), right atrium in 1 (6.7%), and right ventricle in 5 (33.3%). Intracardiac echocardiography was used in 13 (86.7%) and revealed an effusion before overt instability in 11 (73.3%). Thirteen (86.7%) patients developed a blood pressure <60 mmHg. The pressure stabilized in all patients after pericardiocentesis (hypotension to intervention: 10.1 +/- 5.1 minutes). The total blood volume removed was 848 +/- 880 mL (left atrium/right atrium: 1,074 +/- 1,002 vs right ventricle: 396 +/- 266, P = 0.168). Two patients required surgery to close left atrium dome perforations. The ablation was completed in 7 (46.7%) patients. Ten (66.7%) later developed early reoccurrence of AF. All patients were neurologically intact at hospital discharge. During a 1.5 +/- 1.1 year follow-up, AF was eliminated (n = 4) or controlled (n = 1) in 5 (71.4%) patients with complete procedures, and 2 (20.0%) patients underwent successful repeat ablation. CONCLUSION: The incidence of perforation during ablation of the left atrium is low. Most perforations occur in the left atrium; however, few require surgical closure. Although less than with uncomplicated procedures, the majority of patients with complete ablations achieve long-term elimination of AF.

Adult↗

Analysis of catheter-tip (8-mm) and actual tissue temperatures achieved during radiofrequency ablation at the orifice of the pulmonary vein.

BACKGROUND: Many ablative approaches in or near the orifice of the pulmonary vein (PV) have demonstrated success in eliminating atrial fibrillation. Despite current practice, there are no data regarding the in vivo efficacy and safety of an 8-mm catheter tip for ablation at the PV orifice. METHODS AND RESULTS: Ten mongrel dogs were studied. Thermocouples were implanted in the atrial muscle of the PV orifice. Intracardiac echocardiography monitored catheter position, tip/tissue orientation, and microbubble formation. Ninety-four ablations were performed for 120 seconds. A temperature discrepancy >10 degrees C between the catheter tip and tissue occurred during 47 (50%) of the ablations. Despite termination of energy delivery, the average tissue temperature remained within 1 degrees C of the achieved steady state for 9 seconds. A temperature discrepancy >10 degrees C was more common in the right superior PV, with oblique catheter positioning, when tissue temperatures were >60 degrees C or 80 degrees C, and with type 1 or type 2 microbubble formation. However, microbubbles were not present in 7 (13%, type 1) and 10 (40%, type 2) ablations with tissue temperatures >80 degrees C. The maximum tissue temperature achieved with non-full-thickness lesions was 47.3+/-7.4 degrees C vs 75.9+/-11.7 degrees C (P<0.0001) for full-thickness lesions. CONCLUSIONS: Marked discrepancies between catheter-tip and tissue temperatures occurred with higher temperatures, prolonged ablation times, and unfavorable catheter thermistor-tissue contact. Also, these data suggest a conservative approach to atrial ablation, because full-thickness lesions were obtained when tissue temperatures reached 50 degrees C to 60 degrees C and the tissue retained high heat levels despite termination of radiofrequency energy. Finally, microbubbles are inconsistent markers of tissue overheating.

Animals↗

The prognostic significance of exercise-induced atrial arrhythmias.

OBJECTIVES: The purpose of the study was to determine if atrial ectopy (AE) or atrial arrhythmias during exercise are predictive of an increased risk of cardiac events and death. BACKGROUND: Although stress-induced atrial arrhythmias are common during exercise testing, there is a paucity of data regarding the correlation with underlying heart disease and cardiovascular outcomes. Atrial arrhythmias may reflect underlying left atrial enlargement and diastolic dysfunction, which are prognostic of mortality. We hypothesized that these stress-induced arrhythmias are associated with long-term adverse cardiac events. METHODS: Exercise echocardiography was performed in 5,375 patients (age 61 +/- 12 years) with known or suspected coronary artery disease. An abnormal result was defined as exercise-induced atrial fibrillation (AF)/atrial flutter, supraventricular tachycardia (SVT), or AE. RESULTS: A total of 311 (5.8%) patients died (132 [2.5%] from cardiac causes) over a period of 3.1 +/- 1.7 years. In addition, 193 (3.6%) patients experienced a myocardial infarction (MI) and 531 (9.9%) patients required revascularization. During exercise testing, 1,272 (24%) patients developed AE, 185 (3.4%) developed SVT, and 43 (0.8%) developed AF. The five-year cardiac death rate was not statistically different between groups (none [3.8%], AE [4.3%], SVT [3.7%], AF [0%], p = 0.43). The five-year rate of MI was significantly different between groups (none [5.7%], AE [8.3%], SVT [0%], AF [9.0%], p = 0.005). The five-year rate of revascularization between groups was not significantly different (none [14.2%], AE [17.0%], SVT [11.8%], AF [14.8%], p = 0.50). A composite of all five-year adverse end points was similar between groups (none [22.7%], AE [27.8%], SVT [17.7%], AF [25.7%], p = 0.10). In stepwise multivariate analysis, AE was not predictive of myocardial infarction when taking into account traditional clinical variables and exercise test results. CONCLUSIONS: In this large cohort of patients, the occurrence of AE was predictive of an increased risk of MI. However, the association did not persist after adjustment for clinical and exercise variables known to predict adverse long-term cardiovascular outcomes. The rate of long-term cardiac death or revascularization was not influenced by the development of stress-induced atrial arrhythmias.

Aged↗

Admission predictors of in-hospital mortality and subsequent long-term outcome in survivors of ventricular fibrillation out-of-hospital cardiac arrest: a population-based study.

BACKGROUND: Survival following out-of-hospital cardiac arrest (OHCA) from ventricular fibrillation (VF) is poor and dependent on a rapid emergency response system. Improvements in emergent early response have resulted in a higher percentage of patients surviving to admission. However, the admission variables that predict both short- and long-term survival in a region with high discharge survival following OHCA require further study in order to identify survivors at subsequent highest risk. METHODS: All patients with OHCA arrest in Olmsted County Minnesota between 1990 and 2000 who received defibrillation of VF by emergency services were included in the population-based study. Baseline patient admission characteristics in survivor and nonsurvivor groups were compared. Survivors to hospital discharge were prospectively followed to determine long-term survival. RESULTS: Two hundred patients suffered a VF arrest. Of these patients, 145 (73%) survived to hospital admission (7 died within the emergency department) and 79 (40%) were subsequently discharged. Sixty-six (83%) were male, with an average age of 61.9 +/- 15.9 years. Univariate predictors of in-hospital mortality included call-to-shock time (6.6 vs. 5.5 min, p = 0.002), a nonwitnessed arrest (75.4 vs. 92.4%, p = 0.008), in-field use of epinephrine (27.8 vs. 93.4%, p < 0.001), age (68.1 vs. 61.9 years, p = 0.017), hypertension (36.1 vs. 14.1%, p = 0.005), ejection fraction (32.4 vs. 42.4, p = 0.012), and use of digoxin (34.9 vs. 12.7%, p = 0.002). Of all these variables, hypertension [hazard ratio (HR) 4.0, 95% CI 1.1-14.1, p = 0.03], digoxin use (HR 4.5, 95% CI 1.3-15.6, p = 0.02), and epinephrine requirement (HR 62.0, 95% CI 15.1-254.8, p < 0.001) were multivariate predictors of in-hospital mortality. Nineteen patients (24%) had died prior to the survey follow-up. Five patients experienced a cardiac death, resulting in a 5-year expected cardiac survival of 92%. Multivariate variables predictive of long-term mortality include digoxin use (HR 3.02, 95% CI 1.80-5.06, p < 0.001), hypertension (HR 2.06, 95% CI 2.12-3.45, p = 0.006), and call-to-shock time (HR 1.18, 95% CI 1.01-1.38, p = 0.038). CONCLUSION: A combined police/fire/EMS defibrillation program has resulted in an increase of patients surviving to hospital admission after OHCA. This study confirms the need to decrease call-to-shock times, which influence both in-hospital and long-term mortality. This study also identifies the novel demographic variables of digoxin and hypertension, which were also independent risk factors of increased in-hospital and long-term mortality. Identification of these variables may provide utility in identifying those at high-risk of subsequent mortality after resuscitation.

Aged↗