A surgeon's guide to the universe.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Douglas R Hamilton.
Explore the source record for details and available documents.
The United States Government has recently refocused their space program on manned missions to the Moon by 2018 and later to Mars. While there are many potential risks associated with exploration-class missions, one of the most serious and unpredictable is the effect of acute space radiation exposure, and the space program must make every reasonable effort to mitigate this risk. The two cosmic sources of radiation that could impact a mission outside the Earth's magnetic field are solar particle events (SPE) and galactic cosmic radiation (GCR). Either can cause acute and chronic medical illness. Numerous researchers are currently examining the ability of GCR exposure to induce the development of genetic changes that lead to malignancies and other delayed effects. However, relatively little has been published on the medical management of an acute SPE event and the potential impact on the mission and crew. This review paper will provide the readers with medical management options for an acute radiation event based on recommendations from the Department of Homeland Security (DHS), Centers for Disease Control (CDC), and evidence-based critical analysis of the scientific literature. It is the goal of this paper to stimulate debate regarding the definition of safety parameters for exploration-class missions to determine the level of medical care necessary to provide for the crew that will undertake such missions.
Due to the limited treatment and return capabilities of most space vehicles, an in-flight cardiac event could result in significant mission impact or even failure. The current literature supports including electron-beam computed tomography (EBCT) and highly selective C-reactive protein (hsCRP) for diagnosis of coronary artery disease (CAD) in asymptomatic, low-pretest probability cohorts. This paper will examine the issues surrounding adding these tests to astronaut retention and selection algorithms. An evidenced-based literature review was performed and consensus obtained from subject-matter experts to create novel cardiac screening algorithms for astronaut applicants and the current astronaut corps. The main focus of this paper is to derive an evidenced-based approach for improving the diagnosis of significant CAD using EBCT and hsCRP testing. The recommended initial astronaut selection and long-duration mission assignment screening algorithms use EBCT-derived calcium scores and serum hsCRP levels to screen for CAD and predict individual cardiac risk. The current medical evidence is compelling for the international space medicine community to consider: (1) Astronaut candidates with a coronary artery calcium score >0 should be disqualified from initial selection; (2) Astronauts with a coronary artery calcium score >100 should be disqualified from selection for long-duration missions; (3) Elevated hsCRP is a reliable risk factor for helping predict future cardiac events that should warrant primary prevention but not necessarily medical disqualification.
Explore the source record for details and available documents.
BACKGROUND: Focused assessment with sonography for trauma (FAST) examination has been proved accurate for diagnosing trauma when performed by nonradiologist physicians. Recent reports have suggested that nonphysicians also may be able to perform the FAST examination reliably. A multipurpose ultrasound system is installed on the International Space Station as a component of the Human Research Facility. Nonphysician crew members aboard the International Space Station receive modest training in hardware operation, sonographic techniques, and remotely guided scanning. This report documents the first FAST examination conducted in space, as part of the sustained effort to maintain the highest possible level of available medical care during long-duration space flight. METHODS: An International Space Station crew member with minimal sonography training was remotely guided through a FAST examination by an ultrasound imaging expert from Mission Control Center using private real-time two-way audio and a private space-to-ground video downlink (7.5 frames/second). There was a 2-second satellite delay for both video and audio. To facilitate the real-time telemedical ultrasound examination, identical reference cards showing topologic reference points and hardware controls were available to both the crew member and the ground-based expert. RESULTS: A FAST examination, including four standard abdominal windows, was completed in approximately 5.5 minutes. Following commands from the Mission Control Center-based expert, the crew member acquired all target images without difficulty. The anatomic content and fidelity of the ultrasound video were excellent and would allow clinical decision making. CONCLUSIONS: It is possible to conduct a remotely guided FAST examination with excellent clinical results and speed, even with a significantly reduced video frame rate and a 2-second communication latency. A wider application of trauma ultrasound applications for remote medicine on earth appears to be possible and warranted.
BACKGROUND: Ultrasound imaging is a successful modality in a broad variety of diagnostic applications including trauma. Ultrasound has been shown to be accurate when performed by non-radiologist physicians; recent reports have suggested that non-physicians can perform limited ultrasound examinations. A multipurpose ultrasound system is installed on the International Space Station (ISS) as a component of the Human Research Facility (HRF). This report documents the first ocular ultrasound examination conducted in space, which demonstrated the capability to assess physiologic alterations or pathology including trauma during long-duration space flight. METHODS: An ISS crewmember with minimal sonography training was remotely guided by an imaging expert from Mission Control Center (MCC) through a comprehensive ultrasound examination of the eye. A multipurpose ultrasound imager was used in conjunction with a space-to-ground video downlink and two-way audio. Reference cards with topological reference points, hardware controls, and target images were used to facilitate the examination. Multiple views of the eye structures were obtained through a closed eyelid. Pupillary response to light was demonstrated by modifying the light exposure of the contralateral eye. RESULTS: A crewmember on the ISS was able to complete a comprehensive ocular examination using B- and M-mode ultrasonography with remote guidance from an expert in the MCC. Multiple anteroposterior, oblique, and coronal views of the eye clearly demonstrated the anatomic structures of both segments of the globe. The iris and pupil were readily visualized with probe manipulation. Pupillary diameter was assessed in real time in B- and M-mode displays. The anatomic detail and fidelity of ultrasound video were excellent and could be used to answer a variety of clinical and space physiologic questions. CONCLUSIONS: A comprehensive, high-quality ultrasound examination of the eye was performed with a multipurpose imager aboard the ISS by a non-expert operator using remote guidance. Ocular ultrasound images were of diagnostic quality despite the 2-second communication latency and the unconventional setting of a weightless spacecraft environment. The remote guidance techniques developed to facilitate this successful NASA research experiment will support wider applications of ultrasound for remote medicine on Earth including the assessment of pupillary reactions in patients with severe craniofacial trauma and swelling.
INTRODUCTION: The performance of complex tasks on the International Space Station (ISS) requires significant preflight crew training commitments and frequent skill and knowledge refreshment. This report documents a recently developed "just-in-time" training methodology, which integrates preflight hardware familiarization and procedure training with an on-orbit CD-ROM-based skill enhancement. This "just-in-time" concept was used to support real-time remote expert guidance to complete ultrasound examinations using the ISS Human Research Facility (HRF). METHODS: An American and Russian ISS crewmember received 2 h of "hands on" ultrasound training 8 mo prior to the on-orbit ultrasound exam. A CD-ROM-based Onboard Proficiency Enhancement (OPE) interactive multimedia program consisting of memory enhancing tutorials, and skill testing exercises, was completed by the crewmember 6 d prior to the on-orbit ultrasound exam. The crewmember was then remotely guided through a thoracic, vascular, and echocardiographic examination by ultrasound imaging experts. RESULTS: Results of the CD-ROM-based OPE session were used to modify the instructions during a complete 35-min real-time thoracic, cardiac, and carotid/jugular ultrasound study. Following commands from the ground-based expert, the crewmember acquired all target views and images without difficulty. The anatomical content and fidelity of ultrasound video were adequate for clinical decision making. CONCLUSIONS: Complex ultrasound experiments with expert guidance were performed with high accuracy following limited preflight training and multimedia based in-flight review, despite a 2-s communication latency. In-flight application of multimedia proficiency enhancement software, coupled with real-time remote expert guidance, facilitates the successful performance of ultrasound examinations on orbit and may have additional terrestrial and space applications.
INTRODUCTION: The screening tests for coronary artery disease (CAD) for applicants and the active astronaut corps are similar to those performed in the 1960s. Due to the limited treatment and return capabilities of most space vehicles, an in-flight cardiac event would result in mission failure. Improved CAD screening of astronauts is, therefore, paramount to long-duration mission success. METHODS: Literature review was performed to compare active and retired astronaut populations to other asymptomatic low-risk cohorts. All populations were examined to determine the incidence and prevalence of CAD. Framingham risk scores were calculated in NASA's active and retired astronaut corps and compared with age- and gender-matched controls. RESULTS: The current standards used for astronaut selection have been successful in creating a cohort that has less risk than their age- and gender-matched counterparts from the general population. However, the existing astronaut cardiovascular screening and selection tests do not adequately rule out CAD for long-duration missions, and, therefore, a "significant" risk of cardiac event remains, especially as we look toward Exploration Class missions. CONCLUSIONS: The current astronaut selection and retention standards may not adequately prevent cardiac events from occurring with the longer duration flights. Future research should be directed toward increasing the primary and secondary prevention of CAD in the astronaut cohort. In the meantime, the space program should evaluate the use of more aggressive terrestrial screening tools. It is important not to remove all older, experienced pilots from spaceflight crews unless overt or predictable pathology has been clearly identified.
Investigative procedures were approved by Henry Ford Human Investigation Committee and NASA Johnson Space Center Committee for Protection of Human Subjects. Informed consent was obtained. Authors evaluated ability of nonphysician crewmember to obtain diagnostic-quality musculoskeletal ultrasonographic (US) data of the shoulder by following a just-in-time training algorithm and using real-time remote guidance aboard the International Space Station (ISS). ISS Expedition-9 crewmembers attended a 2.5-hour didactic and hands-on US training session 4 months before launch. Aboard the ISS, they completed a 1-hour computer-based Onboard Proficiency Enhancement program 7 days before examination. Crewmembers did not receive specific training in shoulder anatomy or shoulder US techniques. Evaluation of astronaut shoulder integrity was done by using a Human Research Facility US system. Crew used special positioning techniques for subject and operator to facilitate US in microgravity environment. Common anatomic reference points aided initial probe placement. Real-time US video of shoulder was transmitted to remote experienced sonologists in Telescience Center at Johnson Space Center. Probe manipulation and equipment adjustments were guided with verbal commands from remote sonologists to astronaut operators to complete rotator cuff evaluation. Comprehensive US of crewmember's shoulder included transverse and longitudinal images of biceps and supraspinatus tendons and articular cartilage surface. Total examination time required to guide astronaut operator to acquire necessary images was approximately 15 minutes. Multiple arm and probe positions were used to acquire dynamic video images that were of excellent quality to allow evaluation of shoulder integrity. Postsession download and analysis of high-fidelity US images collected onboard demonstrated additional anatomic detail that could be used to exclude subtle injury. Musculoskeletal US can be performed in space by minimally trained operators by using remote guidance. This technique can be used to evaluate shoulder integrity in symptomatic crewmembers after strenuous extravehicular activities or to monitor microgravity-associated changes in musculoskeletal anatomy. Just-in-time training, combined with remote experienced physician guidance, may provide a useful approach to complex medical tasks performed by nonexperienced personnel in a variety of remote settings, including current and future space programs.
Physiologists and clinicians commonly refer to "pressure" as a measure of the constraining effects of the pericardium; however, "pericardial pressure" is really a local measurement of epicardial radial stress. During diastole, from the bottom of the y descent to the beginning of the a wave, pericardial pressure over the right atrium (P(pRA)) is approximately equal to that over the right ventricle (P(pRV)). However, in systole, during the interval between the bottom of the x descent and the peak of the v wave, these two pericardial pressures appear to be completely decoupled in that P(pRV) decreases, whereas P(pRA) remains constant or increases. This decoupling indicates considerable mechanical independence between the RA and RV during systole. That is, RV systolic emptying lowers P(pRV), but P(pRA) continues to increase, suggesting that the relation of the pericardium to the RA must allow effective constraint, even though the pericardium over the RV is simultaneously slack. In conclusion, we measured the pericardial pressure responsible for the previously reported nonuniformity of pericardial strain. P(pRA) and P(pRV) are closely coupled during diastole, but during systole they become decoupled. Systolic nonuniformity of pericardial constraint may augment the atrioventricular valve-opening pressure gradient in early diastole and, so, affect ventricular filling.
INTRODUCTION: An intrathoracic injury may be disastrous to a crew-member aboard the International Space Station (ISS) if the diagnosis is missed or delayed. Symptomatic or clinically suspicious thoracic trauma is treated as a surgical emergency on Earth, usually with immediate stabilization and rapid transport to a facility that is able to deliver the appropriate medical care. A similar approach is planned for the ISS; however, an unnecessary evacuation would cause a significant mission impact and an exorbitant expense. HYPOTHESIS: The use of ultrasound imaging for the detection of pneumothorax and hemothorax in microgravity is both possible and practical. METHODS: Sonography was performed on anesthetized pigs in a ground-based laboratory (n = 4) and microgravity conditions (0 G) during parabolic flight (n = 4). Aliquots of air (50-500 ml) or saline (10-200 ml) were introduced into the pleural space to simulate pneumothorax and hemothorax, respectively. RESULTS: The presence of "lung sliding" excluded pnemothorax. In microgravity, a loss of "lung sliding" was noted simultaneously in the anterior and posterior sonographic windows after 100 ml of air was introduced into the chest, indicating pneumothorax. The presence of the fluid layer in simulated hemothorax was noted in the anterior and posterior sonographic windows after 50 ml of fluid was injected into the pleural space. During the microgravity phase, the intrapleural fluid rapidly redistributed so that it could be detected using either anterior or posterior sonographic windows. CONCLUSION: Modest to severe pneumothorax and hemothorax can be diagnosed using ultrasound in microgravity.
BACKGROUND: The Focused Assessment with Sonography for Trauma (FAST) examines for fluid in gravitationally dependent regions. There is no prior experience with this technique in weightlessness, such as on the International Space Station, where sonography is currently the only diagnostic imaging tool. STUDY DESIGN: A ground-based (1 g) porcine model for sonography was developed. We examined both the feasibility and the comparative performance of the FAST examination in parabolic flight. Sonographic detection and fluid behavior were evaluated in four animals during alternating weightlessness (0 g) and hypergravity (1.8 g) periods. During flight, boluses of fluid were incrementally introduced into the peritoneal cavity. Standardized sonographic windows were recorded. Postflight, the video recordings were divided into 169 20-second segments for subsequent interpretation by 12 blinded ultrasonography experts. Reviewers first decided whether a video segment was of sufficient diagnostic quality to analyze (determinate). Determinate segments were then analyzed as containing or not containing fluid. A probit regression model compared the probability of a positive fluid diagnosis to actual fluid levels (0 to 500 mL) under both 0-g and 1.8-g conditions. RESULTS: The in-flight sonographers found real-time scanning and interpretation technically similar to that of terrestrial conditions, as long as restraint was maintained. On blinded review, 80% of the recorded ultrasound segments were considered determinate. The best sensitivity for diagnosis in 0 g was found to be from the subhepatic space, with probability of a positive fluid diagnosis ranging from 9% (no fluid) to 51% (500 mL fluid). CONCLUSIONS: The FAST examination is technically feasible in weightlessness, and merits operational consideration for clinical contingencies in space.
Explore the source record for details and available documents.
BACKGROUND: Ultrasound is of proven accuracy in abdominal and thoracic trauma and may be useful for diagnosing extremity injury in situations where radiography is not available such as military and space applications. We prospectively evaluated the utility of extremity ultrasound performed by trained, nonphysician personnel in patients with extremity trauma to simulate remote aerospace or military applications. METHODS: Patients with extremity trauma were identified by history, physical examination, and radiographic studies. Ultrasound examination was performed bilaterally by nonphysician personnel, blinded to radiographic results, with a portable ultrasound device using a 10- to 5-MHz linear probe. Images were videorecorded for later analysis against radiography by Fisher's exact test. RESULTS: There were 158 examinations performed in 95 patients. The average time of examination was 4 minutes. Ultrasound accurately diagnosed extremity injury in 94% of patients with no false-positive examinations; accuracy was greater in midshaft locations and least in the metacarpal/metatarsals. Soft tissue/tendon injury was readily visualized. CONCLUSION: Extremity ultrasound can be performed quickly and accurately by nonphysician personnel with excellent accuracy. Pulmonary ultrasound appears promising; blinded verification of the utility of ultrasound in patients with extremity injury should be performed to determine whether extremity and respiratory evaluation should be added to the FAST examination (the FASTER examination) and to verify the technique in remote locations such as military and aerospace applications.
Explore the source record for details and available documents.