PubMed Health⌕ Search

Biomedical subjects

Drew Rodysill

Publications and source records attributed to Drew Rodysill.

2 recordsLinked to original sources

Polyp measurement with CT colonography: multiple-reader, multiple-workstation comparison.

OBJECTIVE: The risk of invasive colorectal cancer in colorectal polyps correlates with lesion size. Our purpose was to define the most accurate methods for measuring polyp size at CT colonography (CTC) using three models of workstations and multiple observers. MATERIALS AND METHODS: Six reviewers measured 24 unique polyps of known size (5, 7, 10, and 12 mm), shape (sessile, flat, and pedunculated), and location (straight or curved bowel segment) using CTC data sets obtained at two doses (5 mAs and 65 mAs) and a previously described colonic phantom model. Reviewers measured the largest diameter of polyps on three proprietary workstations. Each polyp was measured with lung and soft-tissue windows on axial, 2D multiplanar reconstruction (MPR), and 3D images. RESULTS: There were significant differences among measurements obtained at various settings within each workstation (p < 0.0001). Measurements on 2D images were more accurate with lung window than with soft-tissue window settings (p < 0.0001). For the 65-mAs data set, the most accurate measurements were obtained in analysis of axial images with lung window, 2D MPR images with lung window, and 3D tissue cube images for Wizard, Advantage, and Vitrea workstations, respectively, without significant differences in accuracy among techniques (0.11 < p < 0.59). The mean absolute error values for these optimal settings were 0.48 mm, 0.61 mm, and 0.76 mm, respectively, for the three workstations. Within the ultralow-dose 5-mAs data set the best methods for Wizard, Advantage, and Vitrea were axial with lung window, 2D MPR with lung window, and 2D MPR with lung window, respectively. Use of nearly all measurement methods, except for the Vitrea 3D tissue cube and the Wizard 2D MPR with lung window, resulted in undermeasurement of the true size of the polyps. CONCLUSION: Use of CTC computer workstations facilitates accurate polyp measurement. For routine CTC examinations, polyps should be measured with lung window settings on 2D axial or MPR images (Wizard and Advantage) or 3D images (Vitrea). When these optimal methods are used, these three commercial workstations do not differ significantly in acquisition of accurate polyp measurements at routine dose settings.

Algorithms↗

Nonradiologists as second readers for intraluminal findings at CT colonography.

RATIONALE AND OBJECTIVES: Multiple trials have documented wide interobserver variability between radiologists interpreting computed tomography colonography (CTC) exams. We sought to determine if nonradiologists could learn to interpret intraluminal findings at CTC with a high degree of sensitivity to determine if they could play a role as second readers in interpreting CTC exams. MATERIALS AND METHODS: Seven nonradiologists (five medical students, two radiologic technologists) undertook self-directed CTC training using a teaching file of 50 cases; thereafter, each reader blindly interpreted 50 cases with colonoscopic correlation (30 positive, 20 negative). Results were compared with a previously studied cohort of radiologists. The two technologists additionally repeated the exam after 6 weeks of clinical experience. RESULTS: The sensitivity of nonradiologists for small (5-9 mm) polyps, large (>9 mm) lesions, and cancers was similar to that of radiologists (0.45 versus 0.63, 0.74 versus 0.71, and 0.80 versus 0.88, respectively). After 6 weeks of clinical experience as second readers, the accuracy of one technologist significantly improved (from 74% to 90%, P = .008), whereas accuracy of the other tended toward improvement (from 74% to 86%%, P = .25). Nonradiologists detected, on average, 6/36 additional polyps (17%) missed by any radiologist, and the sensitivity of 5/7 nonradiologists was significantly greater than at least one of the radiologists (P = .05). CONCLUSION: Nonradiologists can perform similarly to radiologists in interpreting intraluminal findings at CTC, with nonradiologist performance improving even after experience with more than 100 cases. Skilled nonradiologists may play a vital role as a second reader of intraluminal findings or by performing quality control of examinations before patient dismissal.

Cohort Studies↗