Influence of image processing on chest radiograph interpretation and decision changes.

RATIONALE AND OBJECTIVES: The authors investigate the effect of image processing on diagnostic performance in the reading of computed chest radiographs. MATERIALS AND METHODS: Six radiologists read 168 chest images with and without the use of image processing. Diagnostic performance was measured by means of receiver operating characteristic analysis, and changes made in diagnostic decisions with the use of image processing were evaluated. RESULTS: There were no statistically significant differences between reader performance with image processing and reader performance without image processing (P < .05). Readers' decisions were just as likely to change from false-negative to true-positive as from true-positive to false-negative with the use of image processing. More decisions changed from true-negative to false-positive than from false-positive to true-negative with processing, CONCLUSION: The effect of image processing does not greatly influence diagnostic performance in chest radiography.

Attitude of Health Personnel↗

Perceptual skill, radiology expertise, and visual test performance with NINA and WALDO.

RATIONALE AND OBJECTIVES: The goal of this study was to determine if radiologists possess superior visual search and analysis skills compared with those of laypeople. MATERIALS AND METHODS: In two experiments, radiologists and laypeople searched one of two complex pictorial scenes for hidden targets. Eye position was recorded during the search. Two measures of performance were obtained: accuracy of detecting targets as measured by using alternative free response receiver operating characteristic analysis and visual search efficiency as measured by using eye position analysis. RESULTS: There were no statistically significant differences in detection performance between radiologists and laypeople for either of the search tasks. Radiologists took longer on average to search the images and to first fixate on the targets than did the laypeople. For both groups, true-positive and false-positive decisions were associated with longer dwell times than true-negative decisions. As with radiology search tasks, false-negative decisions were also associated with longer dwell times than true-negative decisions. CONCLUSION: Performance on two visual search and detection tasks indicate that radiologists do not possess superior visual skills compared with laypeople. Radiology expertise is more likely to be a combination of specific visual and cognitive skills derived from medical training and experience in detecting and determining the diagnostic importance of radiographic findings.

Clinical Competence↗

Dynamic-robotic telepathology: Department of Veterans Affairs feasibility study.

In this retrospective study, we assess the accuracy, confidence levels, and viewing times of two generalist pathologists using both dynamic-robotic telepathology and conventional light microscopy (LM) to render diagnoses on a test set of 100 consecutive routine surgical pathology cases. The objective is to determine whether telepathology will allow a pathology group practice at a diagnostic hub to provide routine diagnostic services to a remote hospital without an on-site pathologist. For TP, glass slides were placed on the motorized stage of the robotic microscope of a telepathology system by a senior laboratory technologist in Iron Mountain, MI. Real-time control of the motorized microscope was then transferred to a pathologist in Milwaukee, WI, who viewed images of the glass slides on a video monitor. The telepathologists deferred rendering a diagnosis in 1.5% of cases. Clinically important concordance between the individual diagnoses rendered by telepathology and the "truth" diagnoses established by rereview of glass slides was 98.5%. In the telepathology mode, there were five incorrect diagnoses out of a total of 197 diagnoses. In four cases in which the telepathology diagnosis was incorrect, the pathologist's diagnosis by LM was identical to that rendered by telepathology. These represent errors of interpretation and cannot be ascribed to telepathology. The certainty of the pathologists with respect to their diagnoses was evaluated over time. Results for the first 50 cases served as baseline data. For the second 50 cases, confidence in rendering a diagnosis in the telepathology mode was essentially identical to that of making a diagnosis in the LM viewing mode. Viewing times in the telepathology mode also improved with more experience using the telepathology system. These results support the concept that an off-site pathologist using dynamic-robotic telepathology can substitute for an on-site pathologist as a service provider.

Feasibility Studies↗

Diagnostic accuracy of an international static-imaging telepathology consultation service.

Static-image and dynamic- (real-time) image telepathology are competing technologies. Although some studies suggest that the diagnostic accuracy of the dynamic-image telepathology approaches the accuracy of light microscopy, few reports have documented the diagnostic accuracy of static-image telepathology as used in the setting of an actual surgical pathology consultation practice. We report the results of an analysis of 171 telepathology consultation cases submitted to the Arizona-International Telemedicine Network (AITN). Digital images were submitted by pathologists from six participating institutions in Arizona, Mexico, and China. Telepathologists could render a telepathology diagnosis (TP) or defer rendering a diagnosis to obtain additional video images, glass slides for detailed analysis, or to obtain tissue blocks for special studies such as immunohistochemistry. The telepathologists rendered diagnoses for 144 cases and deferred 27 cases. Two pathologists retrospectively evaluated-glass slides from each case and rendered a consensus glass slide (GS) "truth" diagnosis. There was 88.2% concordance between TP and GS diagnoses (127 of 144 diagnoses). Concordance of 96.5% was achieved for clinically important diagnoses (139 of 144 diagnoses). Telepathologists deferred making a diagnosis to obtain glass slides for conventional light microscopy in 14 cases (8.1%) and for results of immunohistochemistry studies in 13 cases (7.6%). Thus, correct diagnoses were rendered by static-image telepathology in 127 of 171 cases (74.3%) at the time of telepathology diagnostic sessions. Inappropriate field selection and sampling biases of referring pathologists, as well as a tendency of static-image telepathologists to underestimate the complexity of some cases, may reduce the value of consultations based on the viewing of static images.

Humans↗

Differences in time to interpretation for evaluation of bone radiographs with monitor and film viewing.

RATIONALE AND OBJECTIVES: The authors evaluated how observers search hard-copy versus soft-copy images to determine why viewing times are longer for images displayed on a monitor. METHODS: Twenty-seven nonconsecutive bone-trauma computed radiographs were collected from the routine emergency practice. Eye positions of three bone radiologists and three orthopedic surgeons were recorded as they searched images on a view box and digital images at a workstation. RESULTS: Overall viewing time was longer for images displayed on a monitor. Time to first fixate a lesion and true-negative dwell times were significantly longer with the monitor than with the film. Absolute numbers of clusters and dwell times were greater for diagnostic image areas on the monitor than on the film. Twenty percent of the clusters for images viewed on the monitor were on the image-processing menu. CONCLUSION: The amount and type of information that is processed during search is different when images are viewed on a monitor rather than on film.

Bone and Bones↗

Reduction of patient exposure in pediatric radiology.

RATIONALE AND OBJECTIVES: The authors determined whether presently used exposure levels in pediatric imaging can be reduced without loss of information or a decrease in diagnostic accuracy. MATERIALS AND METHODS: Multiple (stacked) image detectors and filters were used to obtain identical compute radiographic images at different exposure levels of neonates with either no active lung disease or hyaline membrane disease. Physical characteristics of the images were measured. A contrast-detail study and a receiver operating characteristic study were conducted to measure observer performance. RESULTS: Physical measurements and results of the contrast-detail study revealed that the dose-reduction images were essentially limited by x-ray quantum noise. Results of the receiver operating characteristic study indicated that diagnostic accuracy did not decrease significantly up to about 75% exposure reduction levels, although image quality rating data decreased with each exposure reduction. CONCLUSION: Decreasing exposure levels to about 75% of current levels may be acceptable in some clinical situations where dose is a concern, such as in pediatric imaging.

Diagnostic Errors↗

Comparison of conventional and computed radiography: assessment of image quality and reader performance in skeletal extremity trauma.

RATIONALE AND OBJECTIVES: Reader performance and image quality wee assessed for standard film, computed film, and computer monitor radiography viewing formats in the evaluation of skeletal extremity trauma. MATERIALS AND METHODS: Three radiologists and three orthopedic surgeons interpreted 27 skeletal radiographs obtained with equivalent technical parameters. Readers evaluated standard film, computed film, and computer monitor formats randomly for fracture and soft-tissue abnormalities. Sessions were videotaped, and eye motion was recorded. RESULTS: No statistically significant differences were found between image formats for true-positive or false-positive findings of trauma indicators. Findings were classified as false-negative based on eye position fixation times. Search errors (lesion not fixated) accounted for 21.7%, 20.6% and 17.1% of false-negative errors with the computer monitor, computed film, and standard film formats, respectively. Combined recognition errors and decision errors were 78.3%, 79.4%, and 82.9%, respectively. Viewing times were longest for the computer monitor images (P < .001). Image quality, contrast, and sharpness were rated highest for computed radiographs (P = .001). Radiologists had a higher true-positive decision rate than orthopedic surgeons (P = .03). CONCLUSION: No statistically significant differences were seen in reader performance among viewing formats. The computed film format received the highest quality rating, and workstation viewing times were longest.

Adolescent↗

Comparison of eye position versus computer identified microcalcification clusters on mammograms.

The purpose of this study was to compare identifications of microcalcification clusters on mammograms by a computerized detection scheme and by human observers having their eye position recorded. Eighty digitized mammograms (half with a subtle microcalcification cluster) were analyzed by a computerized detection scheme and then were read from laser-printed films by six mammographers while eye position was recorded. The computer had 83% true positives with a false-positive rate of 0.5 per image. The true positives of the radiologists ranged from 78% to 90%, with false-positive rates ranging from 0.03 to 0.20. Locations of true and false positives identified by computer and by the human were compared. All but 5% of the true clusters were identified by either the computer, human, or by both. Here 10% of the clusters were detected by only the computer, and 11% were missed by the computer but detected by at least one radiologist. False positives were of three types: identified by computer only, by the human reader only, or by both. Eye-position data indicated significant differences in dwell time between both true-positive and false-positive locations reported by the radiologist versus the computer detections. A follow-up analysis indicated that microcalcification clusters and false positives were judged to have more identifiable characteristics of true calcifications and were associated with longer gaze durations than those with fewer microcalcification characteristics. In general, the computer was able to detect clusters judged to have few or no features that the radiologists were not able to detect. Comparison of computer versus human identification of microcalcification clusters may be useful for improving computerized detection schemes to serve as clinical aids to mammographers, and for understanding what image features lead to false-positive decisions for both the computer and the human reader.

Breast Diseases↗

Ultrasonographic detection of testicular ischemia in a canine model using phospholipid coated microbubbles (MRX-115).

The purpose of this study was to determine if the sonographic contrast agent MRX-115 could improve the accuracy of Doppler ultrasonographic diagnosis of testicular ischemia. Testicular duplex ultrasonography was performed on six dogs before and after surgical ligation of the testicular artery, and before and after intravenous injection of MRX-115. Six radiologists blinded to experimental conditions rated the testicular blood flow. Receiver operating characteristics curves for conditions with and without administration of contrast agent were compared using Student's t-test for paired observations. Statistically significant differences were found both for the tests viewed individually (P = 0.003) and for the testes in comparison to the contralateral side (P = 0.0001). MRX-115 therefore is found to improve duplex sonographic evaluation of testicular ischemia.

Analysis of Variance↗

Visual scanning patterns of radiologists searching mammograms.

RATIONALE AND OBJECTIVES: I examined whether the principles of search, detection, and decision making described for pulmonary nodule detection can be applied to lesion detection in mammographic images. METHODS: The eye position of six radiologists (three staff mammographers and three radiology residents) was recorded as they searched mammograms for masses and microcalcifications. RESULTS: True- and false-positive decisions were associated with prolonged gaze durations; false-negative decisions were associated with longer gaze durations than true-negatives. Readers with more experience tended to detect lesions earlier in the search than did readers with less experience, but those with less experience tended to spend more time overall searching the images and cover more image area than did those with more experience. CONCLUSION: Gaze duration is a useful predictor of missed lesions in mammography, making gaze duration a potential tool for perceptual feedback. Mammographic search for readers with different degrees of experience can be characterized by gaze durations, scan paths, and detection times.

Breast Neoplasms↗

Cause of satisfaction of search effects in contrast studies of the abdomen.

RATIONALE AND OBJECTIVES: Extraintestinal abnormalities visible without contrast material on abdominal radiographs are reported less frequently when contrast examinations are performed. Gaze dwell time was used to determine whether this difference is due to failure by observers to scan plain-film regions of contrast studies or discounting of plain-film abnormalities that were actually scanned. METHODS: Patients were included whose contrast studies had elicited the largest reductions in positive responses compared with their plain-film studies in a previous detection experiment. Gaze of 10 radiologists was studied. RESULTS: Significantly less time was spent gazing at non-contrast regions of contrast examinations than at the corresponding regions of radiographs. Errors with radiographs were based primarily on failures of recognition and decision making, whereas errors with contrast studies were based primarily on faulty scanning. CONCLUSION: Satisfaction of search errors on contrast examinations are caused by reduction in scanning of noncontrast regions.

Contrast Media↗

Clinical assessment of dry laser-processed film versus traditional wet-processed film with computed tomography, magnetic resonance imaging, and ultrasound.

RATIONALE AND OBJECTIVES: To compare image quality and diagnostic performance (by using receiver operating characteristic techniques) for laser imaging film from two systems: a traditional wet system that uses chemical processing and a new dry system that is wet-chemistry-free. METHODS: For three separate studies (computed tomography, magnetic resonance imaging, and ultrasound), identical images for 40 cases were printed on both the wet and dry imaging systems. Ten radiologists participated in each study, giving a decision confidence rating for lesion present or absent and evaluating image quality. RESULTS: In all three studies, there were no statistically significant differences in diagnostic performance when reading images that had been wet processed versus those that had been dry processed. Image quality was comparable for wet-and dry-processed films for all three modalities. CONCLUSION: Dry laser processing produces high-quality radiologic films that are comparable to those currently produced by using wet laser processing. Dry-processed film represents a useful alternative to wet-processed film.

Lasers↗

Estimation of volumes of distribution and intratumoral ethanol concentrations by computed tomography scanning after percutaneous ethanol injection.

RATIONALE AND OBJECTIVES: We developed a technique for estimating the volumes of distribution and intratumoral ethanol concentrations using computed tomography (CT) scanning in patients undergoing percutaneous ethanol injection (PEI) treatment of malignant hepatic tumors. METHODS: A phantom containing anhydrous ethanol diluted with deionized distilled water to concentrations of 0-100% ethanol was scanned by CT. Thirty-seven treatment sessions were performed on eight patients with malignant hepatic tumors undergoing PEI under CT guidance. The patients were scanned pre- and post-PEI, and a region of interest containing the treated hepatic tissue was selected for pixels between -250 and 15 Hounsfield units (H). The mean density of the pixels in this range was computed and the concentration of ethanol estimated. Volumes of distribution of ethanol and intratumoral concentration were then correlated with volume of ethanol injected during PEI. The ratios of volumes of distribution of ethanol to ethanol injected (adjusted in-range [IR]/volume injected) were compared for responders (n = 4) and nonresponders (n = 4). RESULTS: CT numbers in the phantom scaled linearly with ethanol concentration; 100% ethanol measured -234 H. On CT scans after PEI, the volume of distribution of ethanol correlated positively with the volume injected. Calculated intratumoral ethanol concentrations ranged from 4% to 31%. The adjusted IR/volume injected was significantly higher for responders than nonresponders (p < .5). CONCLUSION: CT density data can be used to estimate volume of ethanol distribution in tissue; a larger relative intratumoral distribution of alcohol appears to correlate with a favorable response to PEI. However, CT measurement of intratumoral ethanol concentrations may require more complex computational techniques.

Aged↗

Ultrasound evaluation of sacroiliac motion in normal volunteers.

RATIONALE AND OBJECTIVES: We demonstrated quantitatively, using ultrasound imaging, the passive range of motion of the normal sacroiliac (SI) joint. METHODS: Ultrasound images of the SI joints of 22 adults at rest and during a manual medicine maneuver designed to induce a passive range of motion in the SI joint were obtained. Differences between the baseline alignment of the SI joint and alignment during induced passive motion were observed and measured by six radiologists. RESULTS: Significant movement (> 2 mm) of at least one SI joint was demonstrated in 82% of the subjects using ultrasound recordings. Interobserver (r = .49 - .81) and intraobserver (r = .87) correlations were high. CONCLUSION: The results suggest that the range of passive SI joint motion is more than 2 mm, and may be up to 10 mm in some normal subjects, and that ultrasound imaging could be a useful method for assessing passive SI movement.

Adult↗

Experience-related differences in diagnosis from medical images displayed on monitors.

OBJECTIVE: To compare diagnostic accuracy using conventional versus monitor-displayed medical images in order to determine if years of experience as a board-certified clinician influences diagnostic performance in either modality. MATERIALS AND METHODS: In separate observer performance studies, six radiologists and six pathologists differing in years of experience viewed clinical images, once in the conventional modality (X-ray film or light microscopy) and once using a monitor display. Readers also were surveyed regarding their experience with digital/video display systems. RESULTS: In both studies, performance was similar for conventional and monitor modalities. For the conventional displays, there was a positive correlation between years of clinical experience and performance. For the monitor displays, however, there was a strong negative correlation between years of clinical experience and performance. Performance using the monitor displays correlated highly with experience using digital/video systems in general. CONCLUSION: More exposure to and use of monitor displays, such as recreational video games and computers, may influence positively the clinician-monitor display system interaction and improve diagnostic performance.

Data Display↗