PubMed Health⌕ Search

Biomedical subjects

E A Rose

Publications and source records attributed to E A Rose.

At least 19 recordsLinked to original sources

Long-term use of a left ventricular assist device for end-stage heart failure.

BACKGROUND: Implantable left ventricular assist devices have benefited patients with end-stage heart failure as a bridge to cardiac transplantation, but their long-term use for the purpose of enhancing survival and the quality of life has not been evaluated. METHODS: We randomly assigned 129 patients with end-stage heart failure who were ineligible for cardiac transplantation to receive a left ventricular assist device (68 patients) or optimal medical management (61). All patients had symptoms of New York Heart Association class IV heart failure. RESULTS: Kaplan-Meier survival analysis showed a reduction of 48 percent in the risk of death from any cause in the group that received left ventricular assist devices as compared with the medical-therapy group (relative risk, 0.52; 95 percent confidence interval, 0.34 to 0.78; P=0.001). The rates of survival at one year were 52 percent in the device group and 25 percent in the medical-therapy group (P=0.002), and the rates at two years were 23 percent and 8 percent (P=0.09), respectively. The frequency of serious adverse events in the device group was 2.35 (95 percent confidence interval, 1.86 to 2.95) times that in the medical-therapy group, with a predominance of infection, bleeding, and malfunction of the device. The quality of life was significantly improved at one year in the device group. CONCLUSIONS: The use of a left ventricular assist device in patients with advanced heart failure resulted in a clinically meaningful survival benefit and an improved quality of life. A left ventricular assist device is an acceptable alternative therapy in selected patients who are not candidates for cardiac transplantation.

Activities of Daily Living↗

The cost of long-term LVAD implantation.

BACKGROUND: With increasing use of left ventricular assist devices (LVAD) worldwide, the economics of LVAD implantation have become an important focus of concern. Although these devices have high unit costs, they are the only hope for survival for a large group of terminally ill patients and are likely to have an expansion in indications for use. METHODS: We calculated the costs associated with long-term LVAD implantation. We used the ratio of cost-to-charges method to calculate hospital costs per resource category, market prices for drugs and device, and payments for physician services. RESULTS: Based on our experience with "bridge-to-transplantation" patients, we estimated average first-year costs to be $222,460 including professional fees and $192,154 excluding professional fees. The latter figure is comparable to average first-year costs for cardiac transplantation, which is $176,605 without professional fees at our institution. CONCLUSIONS: The costs of LVAD therapy will change after the first year of implantation, and device reliability and longevity will be important factors in determining these costs. Should the costs of LVAD therapy continue to track those of cardiac transplantation, devices will be cost-effective only if they offer similar efficacy to cardiac transplantation.

Ambulatory Care↗

Long-term outcomes after cardiac transplantation: an experience based on different eras of immunosuppressive therapy.

BACKGROUND: Constantly changing practices in heart transplantation have improved posttransplant survival in patients with end-stage heart disease. The objective of this study was to evaluate long-term outcomes in different eras of immunosuppressive therapy after cardiac transplantation at a single center during a two-decade period. METHODS: A retrospective review of 1,086 consecutive cardiac allograft recipients who underwent transplantation between 1977 to 1999 was performed. Patients were divided into four eras based on type of immunosuppressive therapy: era 1 = steroids, azathioprine (n = 26, February 1977 to March 1983), era II = steroids, cyclosporine (n = 43, April 1983 to April 1985), era III = cyclosporine, steroids, azathioprine (n = 752, April 1985 to December 1995), era IV = cyclosporine, steroids, mycophenolate mofetil (n = 315, January 1996 to October 1999). RESULTS: The actuarial survival of the entire cohort of 1,086 patients undergoing cardiac transplantation was 79%, 66%, and 49% at 1, 5, and 10 years, respectively. There were significant trends in recipient age and gender distribution among the four eras with increasing proportion of older age (> 60 years) and female recipients in eras III and IV (p = 0.001 and 0.02). Early mortality and long-term survival improved significantly over all eras (p < 0.001). Rejection as a cause of death decreased over time (era I, 24%; era II, 21%; era III, 15%; era IV, 9%; p = 0.02), whereas the contribution of transplant coronary artery disease as a cause of death remained unchanged. CONCLUSIONS: Cardiac transplantation provides satisfactory long-term survival for patients with end-stage heart failure. The improving outcomes in survival correlate with improved immunosuppressive therapy in each era. Although the reasons for improvement in survival over time are multifactorial, we believe that changes in immunosuppressive therapy have had a major impact on survival as evidenced by the decreasing number of deaths due to rejection.

Actuarial Analysis↗

Factors affecting long-term survival (>10 years) after cardiac transplantation in the cyclosporine era.

OBJECTIVES: The aim of this study was to determine long-term survival (>10 years) after cardiac transplantation in the cyclosporine era and identify risk factors influencing long-term survival. BACKGROUND: Despite the availability of newer modalities for heart failure, cardiac transplantation remains the treatment of choice for end-stage heart disease. METHODS: Between 1983 and 1988, 195 patients underwent heart transplantation at a single center for the treatment of end-stage heart disease. Multivariable logistic regression analysis of pretransplant risk factors affecting long-term survival after cardiac transplantation included various recipient and donor demographic, immunologic and peritransplant variables. RESULTS: Among the group of 195 cardiac transplant recipients, actuarial survival was 72%, 58% and 39% at 1, 5 and 10 years respectively. In the 65 patients who survived >10 years, mean cardiac index was 2.91/m2 and mean ejection fraction was 58%. Transplant-related coronary artery disease (TRCAD) was detected in only 14 of the 65 patients (22%). By multivariable analysis, the only risk factor found to adversely affect long-term survival was a pretransplant diagnosis of ischemic cardiomyopathy (p = 0.04). CONCLUSIONS: Long-term survivors maintain normal hemodynamic function of their allografts with a low prevalence of TRCAD. It is possible that similar risk factors that lead to coronary artery disease in native vessels continue to operate in the post-transplant period, thereby contributing to adverse outcomes after cardiac transplantation. Aggressive preventive and therapeutic measures are essential to limit the risk factors for development of coronary atherosclerosis and enable long-term survival after cardiac transplantation.

Adolescent↗

Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation.

BACKGROUND: Despite advances in heart transplantation and mechanical circulatory support, mortality among transplant candidates remains high. Better ways are needed to ensure the survival of transplant candidates both inside and outside the hospital. METHODS: In a prospective, multicenter clinical trial conducted at 24 centers in the United States, 280 transplant candidates (232 men, 48 women; median age, 55 years; range, 11-72 years) unresponsive to inotropic drugs, intra-aortic balloon counterpulsation, or both, were treated with the HeartMate Vented Electric Left Ventricular Assist System (VE LVAS). A cohort of 48 patients (40 men, 8 women; median age, 50 years; range, 21-67 years) not supported with an LVAS served as a historical control group. Outcomes were measured in terms of laboratory data (hemodynamic, hematologic, and biochemical), adverse events, New York Heart Association functional class, and survival. RESULTS: The VE LVAS-treated and non-VE LVAS-treated (control) groups were similar in terms of age, sex, and distribution of patients by diagnosis (ischemic cardiomyopathy, idiopathic cardiomyopathy, and subacute myocardial infarction). VE LVAS support lasted an average of 112 days (range, < 1-691 days), with 54 patients supported for > 180 days. Mean VE LVAS flow (expressed as pump index) throughout support was 2.8 L x min(-1) x m(-2). Median total bilirubin values decreased from 1.2 mg/dL at baseline to 0.7 mg/dL (P =.0001); median creatinine values decreased from 1.5 mg/dL at baseline to 1.1 mg/dL (P =.0001). VE LVAS-related adverse events included bleeding in 31 patients (11%), infection in 113 (40%), neurologic dysfunction in 14 (5%), and thromboembolic events in 17 (6%). A total of 160 (58%) patients were enrolled in a hospital release program. Twenty-nine percent of the VE LVAS-treated patients (82/280) died before receiving a transplant, compared with 67% of controls (32/48) (P <.001). Conversely, 71% of the VE LVAS-treated patients (198/280) survived: 67% (188/280) ultimately received a heart transplant, and 4% (10/280) had the device removed electively. One-year post-transplant survival of VE LVAS-treated patients was significantly better than that of controls (84% [158/188] vs 63% [10/16]; log rank analysis P =.0197). CONCLUSION: The HeartMate VE LVAS provides adequate hemodynamic support, has an acceptably low incidence of adverse effects, and improves survival in heart transplant candidates both inside and outside the hospital. The studies of the HeartMate LVAS (both pneumatic and electric) for Food and Drug Administration approval are the only studies with a valid control group to show a survival benefit for cardiac transplantation.

Cohort Studies↗

The development and initial validation of the Exercise Causality Orientations Scale.

Deci and Ryan's causality orientations theory suggests that there are individual differences in motivational orientation towards initiating and regulating behaviour. They described three causality orientations: autonomy, control and impersonal. The aim of this paper is to describe the development and concurrent validity of the Exercise Causality Orientations Scale (ECOS), which was designed to measure the strength of these three orientations within exercise. Altogether, 592 working adults aged 35.0 +/- 11.4 years (mean +/- s) completed the ECOS and measures of self-determination, self-consciousness and social desirability. The analysis was conducted in two parts. First, the data were subjected to confirmatory factor analysis using a multi-trait, multi-method framework. The original model resulted in a poor fit to the data. On the basis of its modification indices, three scenarios with ambiguous items were removed successively, resulting in a scale with good psychometric properties. Secondly, Pearson's correlations were conducted between the subscales of the ECOS and those of the questionnaires used for validation. Most of the results supported a priori hypotheses. In conclusion, our results show the ECOS to have good psychometric properties and they provide some support for its concurrent validity.

Adult↗

Susceptibility of Vespula vulgaris (Hymenoptera: vespidae) to generalist entomopathogenic fungi and their potential for wasp control.

The pathogenicity of Vespula vulgaris wasp workers and larvae to a range of fungi was determined. All fungi were isolated in New Zealand and included isolates from Vespula, known generalist insect pathogens, and isolates generally nonpathogenic to insects. Workers and larvae were highly susceptible to pathogenic isolates at high spore concentrations (>1.75 x 10(5) cfu/individual). Eight isolates, two of Metarhizium anisopliae, five of Beauveria bassiana, and one of Aspergillus flavus were pathogenic while a single isolate of M. flavouiride var. novazealandicum, Cladosporium sp., and Paecilomyces sp. were not. The transfer of spores between workers, and between workers and larvae, was also investigated using several different application methods. Transfer of spores occurred between treated and untreated individuals, and for some of the application methods sufficient spores were transferred to cause mortality of the nontreated individuals. These findings are related to the potential of fungi for the control of wasps.

Animals↗

Multicenter review of preoperative risk factors for stroke after coronary artery bypass grafting.

BACKGROUND: Stroke complicates the postoperative course in 1% to 6% of patients undergoing coronary revascularization. There has been no large scale mandatory database reporting on the incidence of stroke after coronary revascularization. METHODS: A multicenter regional database from the Bureau of Health Care Research Information Services, New York State Department of Health, on 19,224 patients who underwent coronary revascularization in 31 hospitals within New York State during 1995 was analyzed to determine the risk factors for postoperative stroke. RESULTS: The incidence of postoperative stroke was 1.4% (n = 270). Hospital mortality for patients who had a stroke was 24.8%, compared with 2.0% for the rest of the patient population. Postoperative stroke increased the hospital length of stay threefold (27.9+/-1.9 versus 9.1+/-0.9 days, p<0.0001). Multivariable logistic regression identified the following variables to be significantly associated with a postoperative stroke: calcified aorta (p<0.0001; odds ratio [OR], 3.013), prior stroke (p = 0.0003; OR, 1.909), age (p<0.0001; OR, 1.522 per 10 years), carotid arterial disease (p = 0.002; OR, 1.590), duration of cardiopulmonary bypass (p = 0.0004; OR, 1.27 per 60 minutes), renal failure (p = 0.0062; OR, 2.032), peripheral vascular disease (p = 0.0157; OR, 1.62), cigarette smoking (p = 0.0197; OR, 1.621), and diabetes mellitus (p = 0.0158; OR, 1.373). CONCLUSIONS: Postoperative stroke increases mortality and length of stay after coronary revascularization. Several risk factors can be identified, and some of these factors are potentially amenable to intervention, either before or during coronary revascularization, and should also influence patient selection.

Adult↗

Six-year experience of caring for forty-four patients with a left ventricular assist device at home: safe, economical, necessary.

OBJECTIVE: With increasing numbers of implantations, left ventricular assist device programs can put a financial strain on a hospital unless an efficient and safe outpatient program is developed. However, the left ventricular assist device is not widely recognized in the medical community as being reliable enough to support a patient at home. We reviewed our experience with these patients at home to assess the safety and the benefits of such a program. METHODS: Our institutional 6-year experience with 90 consecutive recipients of a wearable left ventricular assist device was analyzed. RESULTS: Forty-four (49%) of the 90 patients who received TCI vented-electric left ventricular assist devices (Thermo Cardiosystems, Inc, Woburn, Mass) were discharged, spending a total of 4546 days (12.5 years) at home with an average of 103 +/- 16 days of outpatient support (range 9-436 days). Of these 44 patients, all were successfully bridged to transplantation (42 patients, 96%) or planned explantation (2 patients, 4%). None of the outpatients died. The cumulative events per outpatient month were 0.020 for bleeding, 0.053 for device infection, 0.0068 for thromboembolus, and 0.020 for major malfunctions. Our estimated average cost to bridge a patient to transplantation or explantation once discharged is $13,200 and as an inpatient over the same length of time, including only room and board, is $165,200. Thirty percent of outpatients were able to return to work or school, 33% to sexual activity, and 44% to driving. All outpatients performed activities of daily living. CONCLUSION: Current left ventricular assist device technology provides effective and economical outpatient support and is associated with limited morbidity and a satisfactory quality of life.

Ambulatory Care↗

Prophylactic photopheresis and chronic rejection: effects on graft intimal hyperplasia in cardiac transplantation.

BACKGROUND: Despite the decreased incidence of acute rejection episodes and improvements in short and intermediate term graft survival with current immunosuppressive agents, there has been little progress in decreasing the morbidity and mortality from chronic rejection. This phenomenon may, in part, be related to the development of a humoral immune response with increases in anti-HLA antibodies, which presents as accelerated graft arteriopathy with intimal hyperplasia. METHODS: Based on prior experimental work, a pilot, prospective, randomized study was performed in 23 primary cardiac transplant recipients to determine whether the addition of prophylactic photopheresis to a cyclosporine, azathioprine and prednisone regimen was safe and resulted in decreased levels of panel reactive antibodies (PRA) and transplant arteriopathy. RESULTS: There was no difference between the two groups in regard to infection or acute rejection incidence. The photopheresis group had a significant reduction in PRA levels at two time points within the first 6 postoperative months. Coronary artery intimal thickness was significantly reduced in the photopheresis group at 1-yr (0.23 vs. 0.49 mm, p < 0.04) and 2-yr (0.28 vs. 0.46 mm, p < 0.02) follow-up compared with the control group. CONCLUSION: In this small pilot study, photopheresis is a safe, well-tolerated immunomodulatory technique that is capable of decreasing the severity of chronic rejection manifesting as post-transplant graft intimal hyperplasia.

Adolescent↗

Impact of current management practices on early and late death in more than 500 consecutive cardiac transplant recipients.

OBJECTIVE: To study risk factors for early and late death after heart transplantation in the current era. SUMMARY BACKGROUND DATA: The current cardiac transplant population differs from earlier periods in that an increasing number of sicker patients, such as those with ventricular assist device (LVAD) support, prior cardiac allotransplantation, and pulmonary hypertension, are undergoing transplantation. In addition, sensitized patients constitute a greater proportion of the transplanted population. Emphasis has been placed on therapies to prevent early graft loss, such as the use of nitric oxide and improved immunosuppression, in addition to newer therapies. METHODS: Five hundred thirty-six patients undergoing heart transplantation between 1993 and 1999 at a single center were evaluated (464 adults and 72 children; 109 had received prior LVAD support and 24 underwent retransplantation). The mean patient age at transplantation was 44.9 years. Logistic regression and Cox proportional hazard models were used to evaluate the following risk factors on survival: donor and recipient demographics, ischemic time, LVAD, retransplantation, pretransplant pulmonary vascular resistance, and immunologic variables (ABO, HLA matching, and pretransplant anti-HLA antibodies). RESULTS: The rate of early death (less than 30 days) was 8.5% in adults and 8.8% in children. The actuarial survival rate of the 536 patients was 83%, 77%, and 71% at 1, 3, and 5 years, respectively, by Kaplan Meier analysis. Risk factors adversely affecting survival included the year of transplant, donor age, and donor-recipient gender mismatching. Neither early nor late death was influenced by elevated pulmonary vascular resistance, sensitization, prior LVAD support, or prior cardiac allotransplantation. CONCLUSIONS: Previously identified risk factors did not adversely affect short- or long-term survival of heart transplant recipients in the current era. The steady improvement in survival during this period argues that advances in transplantation have offset the increasing acuity of transplant recipients.

Adolescent↗

Using faculty development to solve a problem of evaluation and management coding: a case study.

Compliance with billing and coding rules put forth by the Health Care Finance Administration (HCFA) is a challenge for practicing physicians, including those in academic settings. The authors, members of the academic practice at Wayne State University School of Medicine, Department of Family Medicine, designed and delivered a comprehensive curriculum as part of the practice's faculty development initiative surrounding the coding challenge. The authors defined outcomes expected on the way to achieving 100% compliance with HCFA's guidelines. Their curriculum covered topics of coding theory, chart auditing for coding, team building, effective meetings, and structured problem solving. The curriculum was delivered from January to May 1998. Chart audits of 251 charts (office notes) from before the intervention and 263 charts from after the intervention were performed to evaluate differences in coding accuracy. Errors were significantly reduced. The total error rate dropped from 50.2% to 31.1% (p < .05). Overcoding errors were reduced by one third (29.1% versus 19.7%), while undercoding errors were reduced by half (16.3% versus 8.4%). Other errors fell from 4.7% to 3%. The approach of defining and developing work teams and then using standard quality improvement tools may be an effective way to improve compliance with HCFA billing and coding rules. In addition, faculty development can be incorporated into the process of solving a problem that faces a faculty.

Centers for Medicare and Medicaid Services, U.S.↗

Incidence of atrial fibrillation after mild or moderate hypothermic cardiopulmonary bypass.

OBJECTIVES: Atrial fibrillation remains a significant source of morbidity after coronary artery bypass grafting (CABG). Whether cardiopulmonary bypass (CPB) temperature influences the occurrence of postoperative atrial fibrillation in CABG patients has not been specifically examined. In the present study, we reviewed postoperative data from patients who were prospectively randomized to mild or moderate hypothermic CPB for elective CABG to determine the incidence of postoperative atrial fibrillation. DESIGN: Randomized, single center, observational study. SETTING: Tertiary university medical center. PATIENTS: Adults undergoing elective CABG surgery. INTERVENTIONS: Enrolled patients were prospectively randomized to mild (34 degrees C [93.2 degrees F]) or moderate (28 degrees C [82.4 degrees F]) hypothermic CPB. MEASUREMENTS AND MAIN RESULTS: The incidence of postoperative atrial fibrillation was determined by review of ICU and hospital records. There was a significantly higher incidence of atrial fibrillation in the moderate compared with the mild hypothermic CPB group. Patients who had postoperative atrial fibrillation were significantly older than those without atrial fibrillation. Furthermore, a significant increase in the relative risk of developing postoperative atrial fibrillation was found for both age and CPB temperature. CONCLUSIONS: Our results indicate that the temperature of systemic cooling during CPB is an important factor in the development of atrial fibrillation after CABG surgery. In addition, this study confirms that increasing age is a significant determinant of postoperative atrial fibrillation.

Adult↗