Our experience in cardiac transplantation in Baskent University.

Recently cardiac transplantation has an important place in treatment of end-stage cardiac failure. In Turkey between 2003 and 2005 at 10 centers 64 cardiac transplantations were performed including five at our facility. Herein we have presented our results. All patients were men of mean age 34.2 +/- 10.7 (17 to 44) years. Upon preoperative echocardiography their mean ejection fraction was 18% +/- 3.27% (17% to 23%). Pulmonary vascular resistance was 4.47 wood unit in one patient and in one case, there was Rh incompatibility between donor and recipient. We used HTK solution for protection of donor hearts. Mean ischemia time was 251.2 +/- 62.7 minutes (155 to 314). Mean aortic clamping time was 84 +/- 4.7 minutes (80 to 90). In all patients we performed a biatrial anastomosis technique. Hemofiltration was used to prevent hemodilution during operation. In the postoperative period four patients had acute renal dysfunction; one, a minor cerebrovascular accident; two, reoperated because of bleeding; one, cholestasis; one, temporary atrio-ventricular block; and one, mediastinitis. Mean follow-up time was 15.6 +/- 19.7 months (2 to 50). Neither early nor late mortality has occurred. All patients are in New York Heart Association class I. In all cases we used triple immunosuppressive therapy. In the follow-up period the mean number of cardiac biopsies per patient was 4.2 +/- 3.03 (2 to 8). Two cases had cardiac catheterization. As a complication of cardiac biopsy, pericardial tamponade developed in one patient; in another one we observed a right ventricular aneursym after cardiac biopsy. Cardiac transplantation was performed with low mortality and morbidity rates in end-stage cardiac failure patients with longer life expectancy and higher life quality. Unfortunately in our country, because of difficulties to find donor hearts, cardiac transplantations were small in number. For better results, we need a larger series.

Adolescent↗

The effect of anesthetic technique on early postoperative renal function after donor nephrectomy: a preliminary report.

General and regional anesthesia may both be used successfully in donor nephrectomy although the use of regional anesthesia is rare. We compared the remaining kidney function during general (n = 10) versus combined spinal-epidural (n = 10) anesthesia for donor surgery. Blood biochemistry data were collected preoperatively and postoperatively, while renal function was assessed by scintigraphy and urine levels of microalbumin, creatinine, Na, K, Ca and creatinine clearance rate were measured/calculated in 24-hour urine samples collected preoperatively and on postoperative day 2. There were no differences preoperatively and on postoperative day 2 with respect to glomerular filtration rate, microalbuminuria, or creatinine clearance rate (P > .05 for all). There were also no differences between the groups with respect to other scintigraphic findings preoperatively and on postoperative day 2 (P > .05 for all). The results suggest that general or combined spinal-epidural anesthesia for donor nephrectomy have similar effects on the remaining donor kidney function.

Anesthesia, Epidural↗

Pulse contour cardiac output system use in pediatric orthotopic liver transplantation: preliminary report of nine patients.

Anesthetic management of orthotopic liver transplantation (OLT) in pediatric patients is challenging in terms of intraoperative bleeding, fluid management, and hemodynamic monitoring. The pulse contour cardiac output (PiCCO) system, a relatively new device based on the single-indicator transaortic thermodilution technique, may be useful for intraoperative hemodynamic monitoring in pediatric patients. This is a preliminary report of PiCCO use in nine children (aged 9.8 +/- 4.7 years) undergoing OLT. Hemodynamic volumetric parameters monitored by the PiCCO system were mean arterial pressure (MAP), cardiac index (CI), intrathoracic blood volume index (ITBVI), extravascular lung water index (EVLWI), systemic vascular resistance index (SVRI), and stroke volume variability (SVV). All parameters were recorded at anesthesia induction (T0), at the end of the anhepatic phase (Tanhepatic), and at the end of operation (Tend). The PiCCO system revealed similar MAP, CI, EVLWI, SVV, and SVRI values at all measurement intervals. Despite similar central venous pressure measurements, ITBVI values indicated significantly lower values at Tanhepatic than at T0 (627 +/- 160 mL/m2 and 751 +/- 151 mL/m2, respectively, P = .013). There were no PiCCO catheter-related complications in any patient. These findings demonstrate that the PiCCO system is a safe, continuous, multiparameter invasive monitoring device for use in pediatric patients undergoing OLT. This system may provide valuable data during pediatric OLT and appears to be a promising monitoring tool in these patients.

Adolescent↗

Regional versus general anesthesia for donor nephrectomy: effects on graft function.

Various general and regional anesthesia methods are used successfully in living-donor kidney transplantation. This study compared kidney graft function after general versus combined spinal-epidural anesthesia for donor nephrectomy. The study groups included recipients who received grafts from donors who had undergone nephrectomy under general anesthesia (GA group; n=10), and recipients who received grafts from donors who had combined spinal-epidural anesthesia (CSE group, n=10). Standard continuous epidural anesthesia was administered during all transplantations. Graft function was assessed using scintigraphy and Doppler ultrasonography on days 3 and 7. Urine levels of microalbumin, creatinine, and creatinine clearance rate were measured/calculated in 24-hour urine samples collected on postoperative days 3 and 7. There were no differences on either day 3 or day 7 with respect to glomerular filtration rate, microalbuminuria, or creatinine clearance rate (P >.05 for all). There were also no differences between the groups with respect to other scintigraphic findings on day 3 or day 7 (P >.05 for all). Ultrasonography on day 7 showed significantly higher mean peak systolic flow in the main renal artery in the CSE group than in the GA group (P=.035). The results suggest that GA and CSE for donor nephrectomy have similar effects on kidney graft function in recipients.

Adult↗

Penetration of topical 0.3% ciprofloxacin into human aqueous humor.

BACKGROUND AND OBJECTIVE: Investigation of the penetration of topical ciprofloxacin into aqueous humor. PATIENTS AND METHODS: Topical 0.3% ciprofloxacin drops were administered to 17 patients with cataracts before lens extraction surgery. The time interval between the first dose and sampling was 3 hours in 9 patients (group A) and 6 hours in 8 (group B). In both groups, aqueous samples were collected 30 minutes after the last ciprofloxacin application. Ciprofloxacin concentration was determined by high-performance liquid chromatography-fluorescence detection. RESULTS: Mean aqueous concentration was 0.83+/-0.48 microgram/ml in group A and 2.42+/-1.42 micrograms/ml in group B. CONCLUSION: Topical 0.3% ciprofloxacin penetrates into the aqueous in a significant concentration.

Administration, Topical↗