PubMed Health⌕ Search

Biomedical subjects

E Aliot

Publications and source records attributed to E Aliot.

At least 19 recordsLinked to original sources

[Prevalence of sudden cardiac death during sports activities].

Sudden death during sport is a rare and unexpected event. It essentially affects young males, and a cardiomyopathy that had not been diagnosed during medical examinations is present in the majority of cases. In young subjects, there is generally hypertrophic cardiomyopathy or arhythmogenic right ventricular dysplasia. This is revealed during sporting activity, and sudden death is often the first symptom of the disease. Competitive sport increases the relative risk of sudden death to 2.5 compared to the risk in a non-sporting subject. The prevalence of sudden death during competitive sport is poorly understood. From the rare studies available, it could be estimated at 2.3/100,000 athletes per year. In Europe, it essentially occurs during football matches. However, the prevalence of sudden death during so-called 'recreational' sports is not precisely known. It could be much higher because these activities involve a larger number of people, and take place without supervision and usually without a medical examination beforehand. The participants are older, and coronary pathology is usually implicated.

Arrhythmogenic Right Ventricular Dysplasia↗

[Mortality prognostic factors of cardiogenic shock complicating an acute myocardial infarction and treated by percutaneous coronary intervention].

OBJECTIVE: To determine the in-hospital prognosis and late outcome of cardiogenic shock complicating acute myocardial infarction treated by early (< 24 hours) percutaneous coronary intervention (PCI). METHODS: Retrospective monocentric study of a consecutive cohort of patients undergoing early PCI (< 24 heures) for cardiogenic shock complicating acute myocardial infarction from 1994 to 2004. RESULTS: The cohort included 175 patients (mean age = 65 +/- 14 years, 68% male). A successful PCI was obtained in 69% of patients. The in-hospital mortality was 43%. Independent risk factors associated with an increased mortality were: absence of TIMI three flow (P < 0.0001), absence of smoking (P < 0.009) and the need for mechanical ventilation (P < 0.002). Nor stent use or anti GP IIb/IIa infusions were predictors of a better outcome. At hospital discharge, mean left ventricular ejection fraction (LVEF) was 38 +/- 12%. Kaplan-Meier estimate of survival was 63% for in-hospital survivors (maximum follow-up = 9 years). Independent predictors of an impaired long-term outcome were: a LVEF < 0.3 (P < 0.028) and 3-vessel disease on coronary angiography (P < 0.004). CONCLUSION: In-hospital mortality of patients suffering cardiogenic shock complicating acute myocardial infarction and treated by PCI remains high despite PCI improvement. The long-term survival appears, however, to be better than that of patients with coronary artery disease and low LVEF.

Aged↗

[AFFIRM: what we have learned ... and pending issues].

During these last years, several therapeutic strategies trials have been performed in atrial fibrillation: the goal was to compare the rhythm control strategy (restoration and maintenance of sinus rhythm) to the rate control strategy (slowing of heart rate in atrial fibrillation). The most important of these different trials is the AFFIRM study. The main conclusion of this trial is that rate control can be chosen in first intention and not only in case of failure of the rhythm control strategy. These results can not be applied to 2 categories of patients: on one hand patients with heart failure and on the other hand young patients without cardiopathy in whom the strategy of rhythm control and sinus rhythm maintenance, mainly by class I antiarrhythmic drugs, remains the better choice.

Anti-Arrhythmia Agents↗

[Contribution of EKG-gated multislice CT in the diagnosis of arrhythmogenic right ventricle dysplasia: report of two selected cases].

Arrhythmogenic cardiomyopathy of the right ventricle is characterized by replacement of right myocardial cells by fibro-fatty tissue and arrhythmias. The authors present two cases where EKG gated multislice CT was valuable. In one case, comprehensive evaluation of extensive ventricular dysplasia complicated by intraventricular thrombus was achieved whereas accurate evaluation of the ventricular wall process was possible in another case.

Adult↗

[Prevalence of Brugada syndrome among 35,309 inhabitants of Lorraine screened at a preventive medicine centre].

UNLABELLED: Brugada syndrome is a recently identified cause of sudden death. Its primary prevention remains controversial, and epidemiology poorly defined. PATIENT POPULATION AND METHODS: Electrocardiograms (ECG) of 35,309 individuals (mean age = 37.2 years, 47% men) recorded over a 1-year period were reviewed and classified as (1) typical, (2) suspicious, and (3) negative. Subjects whose ECG was suspicious were offered a provocative test with flecainide, 2 mg/kg, i.v., and individuals whose ECG was typical were advised to undergo programmed ventricular stimulation (PVS). RESULTS: In 14 men and 6 women between the ages of 24 and 77 years (mean =47.5), ECGs were typical (n=6) or suspicious (n=14). Among 6 subjects with typical ECGs, 3 underwent PVS, which was positive in 1, who received an implantable cardioverter defibrillator (ICD). Among 14 subjects whose ECGs were suspicious, 5 declined further investigations and 5 developed typical ECG characteristics of Brugada syndrome after flecainide administration. PVS was negative in 4 subjects who consented to the procedure. Overall, among 35,309 individuals screened, 11 had ECG findings consistent with Brugada syndrome and, over a follow-up of 30 months, all had remained free of adverse cardiac event. CONCLUSIONS: we estimated a prevalence of Brugada syndrome of 0.3% in Lorraine. A single patient received an ICD for inducible ventricular tachyarrhythmia during PVS, representing a potential 30 per million asymptomatic adult rate of ICD implantation for this indication.

Adult↗

[Acute or sub-acute thrombosis of steel stents].

The use of coronary endoprostheses has greatly contributed to the improvement in the results of coronary angioplasty. Nevertheless, the risk of stent thrombosis remains a major preoccupation. We studied a retrospective series of 2997 patients who had undergone coronary angioplasty between 1999 and 2003. 36 patients (1.2%) had an acute or sub-acute stent thrombosis, occurring in two thirds of cases in the first 4 days with particularly serious clinical consequences: 5 deaths (13.8%) and 27 myocardial infarctions (75%). A comparison between the 2 groups of patients with thrombosis (n = 36) and without thrombosis (n = 2961) using multivariate analysis determined predictive factors for thrombosis: systolic LV dysfunction < 40% (p < 0.0001 OR 3.8 [2-7.3]), angioplasty for lesions on the anterior interventricular artery (p < 0.0001 OR 2.7 [1.4-5]), angioplasty performed in the acute phase of MI (p < 0.05 OR 13.9 [6.7-29.2]), B2-type complex lesions (p < 0.01 OR 2.5 [1.3-5]), residual dissection at the dilated site (p < 0.02 OR 5.1 [1.4-18.2]). More than ever, acute thrombosis remains a topical subject. This study emphasises the incidence of steel stent thrombosis; the clinical consequences and the predictive factors for early occlusion.

Acute Disease↗

[Imaging of the coronary arteries with multi-channel CT: a pictorial assay].

Advances in cardiac imaging with multidetector row CT allow new applications in the diagnosis of cardiac pathology. The purpose of this article is to illustrate the normal anatomy and main anatomical variants of the coronary arteries that can be detected with multi-channel CT. The images presented here were obtained using 4-channel and 16-channel multi-detector row CT units. Post-processing of CT imaging data was performed using: VRT, MPVR, and 2D curved MPR. Because of continuing technical advances, the use of CT imaging in the evaluation of cardiac disorders is likely to increase.

Coronary Angiography↗

[New systems of mapping and navigation in electrophysiology].

The indications of radiofrequency ablation of arrhythmias have considerably increased since the introduction of the technique in the early 1990s. Interventional rhythmologists now treat arrhythmias which are more and more complex by their mechanism. This requires accurate representation of the ablation catheter position and the integration of spatial and temporal data to identify the arrhythmogenic substrate. The systems of mapping and navigation developed over the last ten years are important tools for interventional rhythmologists. They are very useful for the identification of complex arrhythmogenic substrates which require "individualised" ablations in specific cases. The aim of this article is to review different systems of mapping, and/or navigation currently on the market and their principal characteristics without entering into the details of their use in interventional electrophysiology.

Arrhythmias, Cardiac↗

[The electrocardiogram in ventricular tachycardias].

The electrocardiogram, as much as the clinical examination, is a basic tool for the cardiologist. Technological advances have led to a certain lack of interest in learning to read the electrocardiogram, for which close analysis can allow precise diagnosis, notably in the field of cardiac rhythm disorders. This article concerns the electrocardiogram in ventricular tachycardias with two themes: differential diagnosis of wide QRS complex tachycardias and recognition of the site of origin of a ventricular tachycardia. "Fine" analysis of the electrocardiogram is not an intellectual "game". Actually, careful analysis of the 12 lead ECG allows exact and rapid diagnosis in a large majority of cases, distinguishing a ventricular tachycardia from a supraventricular tachycardia with conduction defect; the appropriate management can be selected without delay. At the same time, close reading of the electrocardiogram also allows the site of origin of a ventricular tachycardia to be recognised. Combining this information with elements of the patient's record can allow the arrhythmia to be related to a known pathology or to prompt a targeted aetiological investigation.

Bundle-Branch Block↗

Safety of a controlled-release flecainide acetate formulation in the prevention of paroxysmal atrial fibrillation in outpatients.

OBJECTIVES: The cardiac safety of a once-a-day 200 mg controlled-release formulation of flecainide acetate in the prevention of paroxysmal atrial fibrillation (PAF) was assessed in outpatients. MATERIAL AND METHODS: The drug was administered for 24 weeks to 227 patients diagnosed with recurrent Paf episodes. Cardiac safety was assessed primarily by the maximum change from baseline in QRS duration. Changes in left ventricular function at echocardiography, incidence of proarrhythmic effects determined from ECG and Holter recordings and cardiovascular adverse events were also taken into account to assess cardiac safety. Efficacy was documented by actuarial methods. RESULTS: Mean maximum QRS increase from baseline was 11.4% (n = 181); QRS increase was < 15% in 71.8% of the patients and > or = 25% in 18.8%. Only 4 patients had maximum QRS value > 100 ms under treatment. Left ventricular ejection fraction remained within +/- 20% of baseline for 90% of the patients, increased above 20% for 8.6% and decrease below 30% for 1.4% (n = 139). Bradycardia (13.2%; n = 129) and ventricular extrasystoles (10.6%; n = 104) were the most frequently identified proarrhythmic effects. Atrio-ventricular block (4.0%), supra-ventricular tachycardia (2.2%), bundle branch block (1.8%) and atrial fibrillation (1.3%) were the most frequent drug-related cardiac adverse events. Estimated treatment success rate was 74% (95% CI: [68%; 80%]) and the incidence of Paf episodes decreased from baseline 28.6% to 11.0% (P < 0.0001). CONCLUSIONS: We provided evidence for a good cardiac safety profile of the controlled-release formulation of flecainide acetate and confirmed the effectiveness of the drug in the prevention of PAF recurrences.

Adult↗

Correlation between electrogram morphology and standard criteria to validate bidirectional cavotricuspid block in common atrial flutter ablation.

AIM: Assessment of a bidirectional conduction block within the cavotricuspid isthmus (CTI) is critical during radiofrequency (RF) atrial flutter (AF) ablation. We investigated the use of bipolar atrial electrogram (BAE) morphology as an additional criterion identifying CTI block and tested it against two recognized criteria: differential pacing and reversal of the right atrial depolarization sequence during coronary sinus (CS) pacing. METHODS AND RESULTS: An RF ablation procedure was performed during 600 ms CS pacing in 100 consecutive patients with a common AF. BAE recorded along the CTI were continuously monitored. CTI conduction block was achieved by RF ablation in all patients and a clear change in BAE polarity in the Electrogram recorded by the dipoles located on the CTI and immediately lateral to the intended line of block (RS to QR pattern) associated with a confirmed CTI conduction block was observed in all cases. BAE morphology changes predicted bidirectional CTI conduction blocks with a 100% positive and a 100% negative predictive value. At a mean follow-up of 33 +/- 11 months, there was a 5% AF recurrence rate. CONCLUSIONS: Our study suggests that morphological changes in BAE recorded at sites lateral and adjacent to the target line of block may be used as a unique and robust criterion to validate CTI conduction block during AF ablation procedure.

Atrial Flutter↗

[Characteristics and causes of death in 283 patients with implanted defibrillators].

UNLABELLED: The implantable automatic defibrillator has proved its superiority over pharmacological treatments for preventing mortality by serious ventricular arrhythmia. We studied the cause of death in a population of 283 consecutive patients implanted between February 1988 and December 2000 (age at implantation: 58 +/- 14.7 years; extremes: 15-78 years, 45 females, ejection fraction: 0.39 +/- 0.15) and followed up over a median of 25 months (extremes = 1 day-163 months). RESULTS: At the end of follow up, 55 patients had died (average age: 62.7 +/- 12.6 years, extremes: 15-79 years, 7 females). All except 2 had a cardiopathy: ischaemic cardiopathy (n = 38, 36 IDDM), dilated cardiomyopathy (n = 14), arrhythmogenic dysplasia of the right ventricle (n = 1). The median interval between implantation and death was 35 months (extremes = 1 day-137 months). The causes of death were the following: cardiac insufficiency (n = 24), refractory arrhythmias (n = 13), other cardiac causes (n = 8), extra-cardiac pathologies (n = 10). The deceased patients had presented an average of 86.6 +/- 23.4 ventricular arrhythmias (extremes = 0-1309) but 18 of them (33%) did not present any during follow up. CONCLUSIONS: Cardiac insufficiency is the prime cause of death in refractory arrhythmias; on patient in 4 dies from ventricular arrhythmia, despite the defibrillator and one deceased patient in 3 had no arrhythmia during follow up.

Adolescent↗

[Relevance of in vitro studies for the immunity of cardiac implants in an electromagnetic field environment]].

The object of this article is to show the contribution of the vitro experimental approach, based on the basic rules of electromagnetic compatibility (EMC), as a complementary tool to the clinical studies. Results can be obtained by a experimental approach in vitro with electromagnetic phantoms associated to a bench of "standard" test to allow a possible comparison between various studies. After describing the protocol developed for the cardiac implants (pacemakers and defibrillators), examples of partial results are presented by way of illustration.

Defibrillators, Implantable↗