PubMed Health⌕ Search

Biomedical subjects

E Annese

Publications and source records attributed to E Annese.

3 recordsLinked to original sources

Femtosecond dynamics in ferromagnetic metals investigated with soft x-ray resonant emission.

We present measurements of the magnetic circular dichroism in x-ray resonant emission in the perpendicular geometry (circularly polarized x rays at normal incidence to the magnetization) for L(2,3) the absorption region in Fe, Co, and Ni metal. The results show that spin-dependent screening of the core hole takes place within the scattering time scale, which is supported by the absence of the effect in ionic systems. This allows an assessment of the time scale for the screening process (up to a few femtoseconds). The process is almost complete within the scattering time for Fe and Co, but this is not the case for the narrow band metal Ni which shows a much slower dynamics.

Journal Article↗

Low energy electronic excitations in the layered cuprates studied by copper L3 resonant inelastic x-ray scattering.

We have measured the resonant inelastic x-ray scattering (RIXS) spectra at the Cu L3 edge in a variety of cuprates. Exploiting a considerably improved energy resolution (0.8 eV) we recorded significant dependencies on the sample composition and orientation, on the scattering geometry, and on the incident photon polarization. The RIXS final states correspond to two families of electronic excitations, having local (dd excitations) and nonlocal (charge-transfer) character. The dd energy splitting can be estimated with a simple crystal field model. The RIXS at the L3 edge demonstrates here a great potential, thanks to the resonance strength and to the large 2p spin-orbit splitting.

Journal Article↗

Systematic errors in multi-frequency EIT.

Systematic errors have been measured with a multi-frequency data-collection system operating between 10.24 and 81.92 kHz. The errors were present even though a conventional background measurement on a uniform saline phantom had already been subtracted. Errors due to changes in transimpedance between the calibration and the tissue measurements, cable movement and electrode-skin contact impedance were simulated giving a total systematic error estimate equivalent to a 9% change in tissue conductivity. It was shown that more than 89% of the image was above the total error magnitude, indicating that most of the image revealed true changes in tissue conductivity. In three human subjects, the largest conductivity changes were in two regions, located posteriorly on either side of the midline, and were interpreted as due to the erector spinae muscles. These regions showed increases in conductivity of 73-104%. Identification of other anatomical features was difficult because of the poor spatial resolution of the images.

Biometry↗