PubMed Health⌕ Search

Biomedical subjects

E Atalar

Publications and source records attributed to E Atalar.

At least 19 recordsLinked to original sources

Magnetic resonance imaging permits in vivo monitoring of catheter-based vascular gene delivery.

BACKGROUND: Gene therapy is an exciting frontier in modern medicine. To date, most investigations about the imaging of gene therapy have primarily focused on noncardiovascular systems, and no in vivo imaging modalities are currently available for monitoring vascular gene therapy. The purpose of this study was to develop an in vivo imaging tool to monitor a catheter-based vascular gene delivery procedure. METHODS AND RESULTS: We produced gadolinium/blue dye and gadolinium/gene-vector media by mixing Magnevist with a trypan-blue or a lentiviral vector carrying a green fluorescent protein (GFP) gene. The gadolinium was used as an imaging marker for magnetic resonance (MR) imaging to visualize vessel wall enhancement, and the blue dye/GFP was used as a tissue stain marker for histology/immunohistochemistry to confirm the success of the transfer. Using Remedy gene delivery catheters, we transferred the gadolinium/blue dye (n=8) or gadolinium/GFP lentivirus (n=4) into the arteries of 12 pigs, that were monitored under high-resolution MR imaging. The results showed, in all 12 pigs, the gadolinium enhancement of the target vessel walls on MR imaging and the blue/GFP staining of the target vessel tissues with histology/immunohistochemistry. This study shows the potential of using MR imaging to dynamically visualize (1) where the gadolinium/genes are delivered; (2) how the target portion is marked; and (3) whether the gene transfer procedure causes complications. CONCLUSIONS: We present a technical development that uses high-resolution MR imaging as an in vivo imaging tool to monitor catheter-based vascular gene delivery.

Animals↗

Transesophageal magnetic resonance imaging of the aortic arch and descending thoracic aorta in patients with aortic atherosclerosis.

OBJECTIVES: We sought to determine the feasibility and potential of transesophageal magnetic resonance imaging (TEMRI) for quantifying atherosclerotic plaque burden in the aortic arch and descending thoracic aorta in comparison with transesophageal echocardiography (TEE). BACKGROUND: Improved morphologic assessment of atherosclerotic plaque features in vivo is of interest because of the potential for improved understanding of the pathophysiology of plaque vulnerability to rupture and progression to clinical events. Magnetic resonance imaging (MRI) is well suited for atherosclerotic plaque imaging. Performing MRI using a radio frequency (RF) receiver probe placed near the region of interest improves the signal-to-noise ratio (SNR). METHODS: High-resolution images of the thoracic aortic wall were obtained by TEMRI in 22 subjects (8 normals, 14 with aortic atherosclerosis). In nine subjects, we compared aortic wall thickness and circumferential extent of atherosclerotic plaque measured by TEMRI versus TEE using a Bland-Altman analysis. Additional studies were performed in a human cadaver with pathology as an independent gold standard for assessment of atherosclerosis. RESULTS: In clinical and experimental studies, we found similar measurements for aortic plaque thickness but a relative underestimation of circumferential extent of atherosclerosis by TEE (p = 0.001), due in large part to the lower SNR in the near field. CONCLUSIONS: Using TEMRI allows for quantitative assessment of thoracic aortic atherosclerotic plaque burden. This technique provides good SNR in the near field, which makes it a promising approach for detailed characterization of aortic plaque burden.

Aged↗

Endourethral MRI.

Although high-resolution MRI with phased array pelvic, endorectal, and endovaginal coils has dramatically enhanced the ability to visualize abnormalities of the female urethra and periurethral tissues, controversy still remains about the anatomy of this region. This study introduces an endourethral approach for ultra-high-resolution MRI of the female urethra and the periurethral tissues. To this end, two different radiofrequency (RF) receiver coil designs for an endourethral insertion have been developed: a single-loop coil and a phased array/quadrature coil. Both designs feature a flexible coil circuit, small loss tuning and matching directly at the coil, active decoupling, and the integration of a lambda/4 coaxial choke to decrease unbalanced currents and limit potential RF heating effects. Effective reduction of the mutual inductance between the two coils of the phased array design was achieved by introducing a metallic "paddle" to steer the flux between the coils. The performance of the coils has been evaluated in female human cadaver studies and in an in vivo pig experiment. The novel endourethral approach enabled a dramatic increase of the signal-to-noise ratio (SNR) at the region of interest (ROI). High-resolution MR images of the female urethra have been acquired with a spatial resolution down to 78 x 78 microm. Histologic correlation was achieved for the MR images generated. The achieved high local SNR and resulting high spatial resolution will add valuable information to the discussion of female urethral anatomy. Magn Reson Med 45:138-146, 2001.

Animals↗

In vivo measurement of pulsewave velocity in small vessels using intravascular MR.

A one-dimensional intravascular MR (IVMR) technique for the measurement of pulsewave velocity in a single cardiac cycle is presented. The technique was used to measure pulsewave velocity in vivo in the intact rabbit model, where its sensitivity to different hemodynamic states was demonstrated using a pharmacological intervention with phenylephrine and nitroprusside. IVMR measurements of pulsewave velocity were found to increase with mean arterial pressure, as expected. Further, IVMR-based pulsewave velocity estimates were in agreement with those measured by pressure catheters and direct distensibility measurement. Because of their rapidity and highly localized nature, these measurements of vessel elasticity may complement the high-resolution vascular imaging information gained in an IVMR examination. This could allow assessment of atherosclerotic plaques and facilitate immediate treatment decisions. Magn Reson Med 45:53-60, 2001.

Animals↗

Effects of stent coating on platelets and endothelial cells after intracoronary stent implantation.

BACKGROUND: Adhesion molecules are known to be important in the regulation of endothelial cell and platelet functions. Increased platelets P-selectin expression is a marker of stent thrombosis after uncoated stent placement. HYPOTHESIS: The aim of this study was to compare the effects of intracoronary placement of phosphorylcholine (PC)-coated, versus heparin-coated, versus uncoated stents on platelets and endothelial activity. METHODS: Thirty patients (age 55 +/- 10, 27 men) with significant proximal left anterior descending coronary artery stenoses were randomized to elective implantation of PC-coated, versus heparin-coated, versus uncoated stents. Following stent placement, intravenous heparin and aspirin plus ticlopidine were administered. Venous plasma soluble E-selectin, sP-selectin, and intercellular adhesion molecule-l levels were measured before the procedure and 24 and 48 h thereafter as markers of platelet and endothelial cell activation. Patients were excluded if they had a disease known to influence platelet and endothelial cell function. RESULTS: Plasma sP-selectin levels decreased significantly after implantation of PC- and heparin-coated stents (p = 0.04), but remained unchanged in patients randomized to uncoated stents. Plasma sE-selectin levels increased significantly after uncoated stent placement (p = 0.04) and remained unchanged after coated stent implantation. CONCLUSION: In patients treated with combined antiplatelet therapy, implantation of PC- and heparin-coated stents decreased platelet activity without activating endothelial cells, whereas placement of uncoated stents led to endothelial activation without changing platelet activity. These results suggest that PC-coated and heparin-coated stents may be advantageous in limiting thrombotic complications.

Angioplasty, Balloon, Coronary↗

Imaging longitudinal cardiac strain on short-axis images using strain-encoded MRI.

This article presents a new method for measuring longitudinal strain in a short-axis section of the heart using harmonic phase magnetic resonance imaging (HARP-MRI). The heart is tagged using 1-1 SPAMM at end-diastole with tag surfaces parallel to a short-axis imaging plane. Two or more images are acquired such that the images have different phase encodings in a direction orthogonal to the image plane. A dense map of the longitudinal strain can be computed from these images using a simple, fast computation. Simulations are conducted to study the effect of noise and the choice of out-of-plane phase encoding values. Longitudinal strains acquired from a normal human male are shown.

Adult↗

Increased plasma levels of soluble selectins in patients with unstable angina.

BACKGROUND: Inflammation plays an important role in the pathogenesis of unstable angina. Adhesion molecules, such as selectins, mediate the interactions between leukocytes, platelets and endothelial cells during inflammation and thrombogenesis. HYPOTHESIS: The purpose of this study was to determine whether soluble E-selectin, P-selectin and L-selectin levels are increased in patients with unstable angina (UA). METHODS: Soluble E-, P- and L-selectin levels were measured by enzyme-linked immunoassay in the peripheral blood of 23 patients with UA, 26 patients with stable angina (SA) and 15 control patients with angiographically normal coronary arteries. RESULTS: Soluble E-selectin levels were significantly higher in patients with UA (45+/-11 ng/ml) than in controls (30+/-8 ng/ml, P<0.001), or patients with SA (34+/-8 ng/ml, P=0.001). Similarly, plasma levels of P- and L-selectin were significantly higher in patients with UA (427+/-144 and 772+/-160 ng/ml, respectively) than in patients with SA (278+/-79 and 643+/-94 ng/ml, respectively, P<0.005 vs. UA for both), or control patients (189+/-43 and 601+/-126 ng/ml, respectively, P=0.001 vs. UA for both). CONCLUSIONS: Plasma levels of soluble selectins were increased in patients with UA compared with patients with SA or patients without angiographically visible coronary artery disease. Measurements of these adhesion molecules may be helpful as non-invasive markers of coronary plaque destabilization in UA.

Angina Pectoris↗

Possibilities of transesophageal MRI for assessment of aortic disease: a review.

The thoracic aortic wall is a common site of atherosclerotic plaque in humans. Tools for serial, non-invasive assessment of these plaques are of value for addressing gaps in our basic understanding of the biology of plaque rupture and its relationship to atherosclerotic disease progression as well as for monitoring response to anti-atherosclerotic interventions in therapeutic clinical trials. Common approaches to assessment of the wall of the thoracic aorta in vivo are limited. Here we discuss some of the challenges and limitations encountered by conventional techniques and review a novel approach, transesophageal MRI (TEMRI). Initial experiences in applying the TEMRI approach to assessment of aortic morphology and pathology are discussed.

Aorta, Thoracic↗

Effect of balloon-induced acute ischaemia on P wave dispersion during percutaneous transluminal coronary angioplasty.

AIMS: P wave dispersion is a recent ECG marker that reflects discontinuous and inhomogeneous conduction of sinus impulses, which has been studied in a limited number of cardiac conditions. The aim of our study was to investigate the effects of angioplasty induced-ischaemia on atrial conduction abnormalities as estimated by P maximum and P dispersion. METHODS AND RESULTS: The study consisted of 67 consecutive patients (41 men, mean age 58 +/- 11 years) with 1-vessel coronary artery disease who underwent elective single vessel coronary angioplasty (left anterior descending (LAD) coronary artery in 28 patients, the right coronary artery (RCA) in 22 patients and the left circumflex coronary artery (LCx) in 17 patients. All patients underwent 12-lead surface ECG before the first inflation (baseline) and then 60 s after intra-coronary balloon inflation. The maximum P wave duration, the minimum P wave duration, and P wave dispersion (Pd=Pmax - Pmin) were calculated from 12-lead surface ECGs. Baseline P wave duration measurements were not significantly different among the patients with LAD, RCA and LCx coronary artery disease (P>0.05). P dispersion and P maximum were significantly higher during balloon occlusion compared with the baseline condition in all three types of coronary dilatation procedures. However, P minimum was not found to differ between baseline and during balloon occlusion (P>0.05). CONCLUSION: The prolongation of P wave dispersion may be a useful and simple additional marker for myocardial ischaemia.

Aged↗

A Green's function approach to local rf heating in interventional MRI.

Current safety regulations for local radiofrequency (rf) heating, developed for externally positioned rf coils, may not be suitable for internal rf coils that are being increasingly used in interventional MRI. This work presents a two-step model for rf heating in an interventional MRI setting: (1) the spatial distribution of power in the sample from the rf pulse (Maxwell's equations); and (2) the transformation of that power to temperature change according to thermal conduction and tissue perfusion (tissue bioheat equation). The tissue bioheat equation is approximated as a linear, shift-invariant system in the case of local rf heating and is fully characterized by its Green's function. Expected temperature distributions are calculated by convolving (averaging) transmit coil specific absorption rate (SAR) distributions with the Green's function. When the input SAR distribution is relatively slowly varying in space, as is the case with excitation by external rf coils, the choice of averaging methods makes virtually no difference on the expected heating as measured by temperature change (deltaT). However, for highly localized SAR distributions, such as those encountered with internal coils in interventional MRI, the Green's function method predicts heating that is significantly different from the averaging method in current regulations. In our opinion, the Green's function method is a better predictor since it is based on a physiological model. The Green's function also elicits a time constant and scaling factor between SAR and deltaT that are both functions of the tissue perfusion rate. This emphasizes the critical importance of perfusion in the heating model. The assumptions made in this model are only valid for local rf heating and should not be applied to whole body heating.

Biophysical Phenomena↗

Acute anterior myocardial infarction following a mild nonpenetrating chest trauma--a case report.

Myocardial infarction in patients under age 45 years is a relatively unusual phenomenon; blunt chest trauma is one of the nonatherosclerotic mechanisms leading to acute myocardial infarction in young adults. The authors report a rare case of anterior myocardial infarction in a 22-year-old man following a mild nonpenetrating chest trauma whose left chest was elbowed during a soccer game.

Adult↗

Percutaneous balloon pericardiotomy for patients with malignant pericardial effusion including three malignant pleural mesotheliomas.

Ten patients were enrolled in this study to evaluate the therapeutic value of percutaneous balloon pericardiotomy in patients with symptomatic pericardial effusion secondary to malignant diseases. Four patients had breast cancer; 2 had lung cancer; 1 had non-Hodgkin's lymphoma; and 3 had malignant pleural mesothelioma, which is commonly seen in Central Anatolian region of Turkey. All patients underwent percutaneous balloon pericardiotomy with monofoil balloons (Mansfield, NuMed). No complication was seen during these procedures. In 3 patients, the balloon could not be expanded completely and was entered from a more lateral position by a second puncture. There was no recurrence of pericardial effusion in 6 of 7 patients without mesothelioma. After percutaneous balloon pericardiotomy, surgical subxiphoid windowing was performed due to drainage greater than 100 mL/day in a patient with lung cancer and in 1 patient with mesothelioma. In the other 2 patients with mesothelioma, recurrence of pericardial effusion was seen and then subxiphoid surgical windowing was performed due to development of cardiac tamponade in 1 of them. All the patients died 68.6 +/- 36 days later due to the primary malignancies. The survival time of patients with mesothelioma was shorter than that of the others (p < 0.05). These results suggest that percutaneous balloon pericardiotomy may be used in the treatment of patients with malignant pericardial effusion as an alternative to surgical pericardial window creation. But in patients with malignant pleural mesothelioma, the success rate of this procedure was lower than that of the others.

Adult↗

Platelet and leukocyte deactivation after intracoronary stent placement in patients receiving combined antiplatelet therapy.

Activated platelets and leukocytes have been demonstrated to play a role in the development of stent thrombosis, and coronary angioplasty has been shown to result in activation of platelets, leukocytes, and endothelial cells. We aimed to evaluate the effects of intracoronary stent placement and aspirin plus ticlopidine treatment on platelets, leukocytes, and endothelial cells via observing the serial changes in the circulating soluble forms of adhesion molecules in 54 patients with coronary artery disease, who had elective coronary angioplasty and stent implantation for a single lesion of the left anterior descending artery. After stent placement, intravenous heparin infusion was administered only for 24 hours, and aspirin plus ticlopidine treatment was applied for 1 month. Venous blood samples were drawn before stent placement, and repeated 24 and 48 hours after the procedure. Patients were excluded if they had had recent cardiovascular events or any illness that might influence platelet, leukocyte, and endothelial cell function. The plasma level of sL-selectin was significantly decreased 48 hours after coronary stenting (636+/-110 ng/mL vs 567+/-93 ng/mL; P = 0.001, respectively). Likewise, the plasma level of sP-selectin was also decreased significantly 48 hours after the procedure (260+/-61 ng/mL vs 233+/-83 ng/mL, P = 0.01). The sE-selectin level was found to be significantly increased 24 hours (31+/-9 ng/mL vs 39+/-12 ng/mL, P = 0.0001) and 48hours(31+/-9 ng/mL vs 42+/-15 ng/mL, P = 0.001) after coronary stenting. The results of our study suggest that significant platelet and leukocyte deactivation take place in patients treated with combined antiplatelet therapy after stenting; endothelial cell activation also occurs during this treatment.

Adult↗

RF transmit power limit for the barewire loopless catheter antenna.

The safety of the barewire loopless catheter antenna in transmit mode is addressed with respect to radiofrequency (RF) heating. Analytical expressions for electric field and specific absorption rate (SAR) distributions surrounding the antenna are postulated and experimentally verified. Limiting RF transmit power to 40-70 mW time-averaged power, depending on the specific antenna design, will ensure that the current regulatory guideline of SAR of 8 W/kg in any gram of tissue is not exceeded. These limits can act as guidelines for the design of RF pulses for use with this device. Further study is required to examine the safety of the antenna in receive mode.

Absorption↗

Toward MRI-guided coronary catheterization: visualization of guiding catheters, guidewires, and anatomy in real time.

The success of x-ray fluoroscopy-guided coronary catheterization depends in part on the ability to obtain simultaneous and real-time visualization of the guidewire, guiding catheter, and anatomy of the chest. The hypothesis explored in this paper is that magnetic resonance imaging (MRI) could provide this ability. This hypothesis was tested with loopless antennas used as the guidewire and a guiding catheter and two surface coils, each connected to four different receiver channels of a GE 1.5-T CV/I MRI scanner. Experiments were conducted on six healthy dogs. Intravascular antennas were inserted in the right carotid artery and maneuvered in the aorta while running a fast gradient-echo sequence (TR/TE 5/1.3 msec, flip angle 7 degrees). Real-time projection images of the chest anatomy, together with the guidewire and guiding catheter, were obtained. Positioning of the MRI guiding catheter either in the descending aorta, ascending aorta, or heart was achieved easily. This study represents a step toward MRI-guided coronary catheterization.

Animals↗