Characterization by flow cytometry of hemopoietic progenitors in bone marrow of histidine decarboxylase knock out and wild type mice.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to E Búzás.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Fragments of high density cartilage proteoglycan (aggrecan) are released during either the normal or pathological turnover of cartilage proteoglycans, which fragments diffuse into the synovial fluids and then appear in the serum. The keratan sulphate (KS; a glycosaminoglycan side chain of aggrecan) is resistant to enzymatic degradation, it has a relatively low clearance and has a "standard" serum level indicating the actual level of cartilage (proteoglycan) breakdown. Using anti-KS monoclonal antibody in ELISA (enzyme-linked immunosorbent assay), we measured serum KS levels in patients with different joint diseases. The highest KS content (595 ng/ml) was measured in the sera of patients with articular chondrocalcinosis (calcium pyrophosphate crystal deposition disease/pseudogout). Slightly lower KS levels were determined in osteoarthrosis (OA; 578 ng/ml) and much less in rheumatoid arthritis (RA; 421 ng/ml). All these patient groups (either with degenerative or inflammatory joint diseases) expressed slightly higher KS levels compared to control blood donors (295 ng/ml). However, there were remarkable variations between these diseased groups, i. e., KS levels in patients with RA were significantly lower than in patients with OA (p < 0.001) and this difference was more pronounced in rheumatoid patients with I-II Steinbrocker stage (370 ng/ml) or in those treated with non-steroid anti-inflammatory drugs (NSAIDs) (382 ng/ml). Keratan sulphate levels in RA patients chronically treated with corticosteroid (460 ng/ml) or auro-thiomalat (473 ng/ml) indicate that these drugs may influence the cartilage metabolism more effectively than the NSAIDs.(ABSTRACT TRUNCATED AT 250 WORDS)
The red blood cell filtration parameters were examined in 82 patients with chronic renal failure and 50 healthy controls. The most expressed decrease in deformability was observed in uremic patients who had not been haemodialysed; the values nearest to the healthy ones were observed in transplanted patients. The deformability was considerably improved after haemodialysis, especially when acetate-containing dialyzing solution was applied.
The authors deal with the clinicopathology of the renal, alterations in light-chain disease in connection with 6 cases. The disease was recognized by the monotype (in 5 cases kappa, in 1 case lambda) immunoreactivity of the light-chain paraprotein deposited in the basal membranes of the renal tissue. Electron microscopic examinations proved the fine-granulated, electrodense character of the paraprotein. Multiple myeloma was found in 3 cases and plasma cell dyscrasia of non-tumorous characteristic in 3 cases in the background of the deposition. The renal involvement appeared clinically in the picture of proteinuria without nephrosis syndrome and in progressing azotemia. Chronic renal insufficiency developed during some months in 5 patients. Morphologically renal impairment manifested in interstitial fibrosis, tubular atrophy and ateriolar hyalinosis was seen. These were associated with different glomerular alterations, for instance in 3 cases with nodular glomerulosclerosis. In 1 patient with plasma cell dyscrasia of non-tumorous characteristic nodular glomerulosclerosis and semilunar formation was observed in 56% of the glomeruli. In an other patient with myeloma the simultaneous existence of cylinder nephropathy and light-chain nephropathy was demonstrated. Both observations are unusual phenomena in plasma cell dyscrasia.
During ten years 59616 haemodialyses were performed with 18139 capillary dialysers on 226 patients being in the final stage of chronic renal insufficiency. With the semi-automatic technique applied blood can be eliminated from the dialyser in 15-20 minutes. Formalin used for desinfection is washed out of the apparatus such a way, that formalin content of the last washing solution ranges between 0-0.1 microgram/ml. Anti-N antibody indicating the presence of formalin could be detected in the serum of 2 patients out of the 120 cases tested. The same dialyser is used repeatedly on one patient, 3.29-times on the average. The regenerated dialyser eliminates compounds of small-and middle molecular weight with the same efficiency up to the 4th repeated use. Ratio of pyrogenic reactions is low, 0.08%. Neither infection or sepsis associated with the regeneration occurred. Rehabilitation degree as well as the survival time of patient corresponded with the average European standard. Because of the "first use syndrome" (allergic symptoms, hypotension, nausea, vomiting, headache, cramps etc.) with 5 patients haemodialysis could be performed only with regenerated dialysers dialyses. From the considerable sums saved by regeneration process 7 satellite dialysing units were established and equipped.
Explore the source record for details and available documents.