PubMed Health⌕ Search

Biomedical subjects

E Ballesteros

Publications and source records attributed to E Ballesteros.

31 records · Page 2Linked to original sources

Sequential determination of triglycerides and free fatty acids in biological fluids by use of a continuous pretreatment module coupled to a gas chromatograph.

A continuous system coupled to a gas-liquid chromatograph was used for the sequential determination of triglycerides and free fatty acids in serum and urine. The module provides compositional information and hence more detailed information on lipid metabolism changes in patients suffering metabolic disorders. Lipids in biological samples are manually extracted in methanol-n-hexane and introduced into the flow system; free fatty acids are then separated by retention on an ion-exchange resin and triglycerides (not retained) are transesterified with acetyl chloride in methanol. The resulting methyl esters are continuously injected into the gas chromatograph and determined by using a flame ionization detector. In a second step, retained free fatty acids are eluted and derivatized (also with acetyl chloride in methanol) and subsequently determined similarly as the triglycerides. The proposed method was applied to the determination of triglycerides in a lipid control serum; free fatty acids were determined in a human pool serum by the proposed method and compared with the volumetric method used in clinical practice. The results obtained in both instances showed good agreement between the results provided for triglycerides and free fatty acids. The proposed method was also applied to urine samples; a parallel recovery study was also made in order to assess the performance of the method.

Automation↗

Automatic gas chromatographic determination of N-methylcarbamates in milk with electron capture detection.

A new analytical method that combines on-line derivatization-extraction and gas-liquid chromatography for the determination of N-methylcarbamates is reported. The hydrolysis products of N-methylcarbamates (phenols) are derivatized and extracted in a continuous fashion using pentafluoropropionic anhydride (derivatizing reagent) in n-hexane as an extractant. The thermal instability of N-methylcarbamates is overcome by forming fluoro derivatives that can be identified and quantified at the nanogram per milliliter level with an ECD detector. Application of the proposed method to six mixtures of N-methylcarbamates yielded detection limits between 2 and 20 ng/mL and a relative standard deviation of 2.35-3.70%. Average recoveries of N-methylcarbamates added to cow's milk at concentrations between 50 ng/mL and 2 micrograms/mL ranged from 93.7 to 100.8%.

Acylation↗

Gas chromatographic determination of phenol compounds with automatic extraction and derivatization.

Two gas chromatographic procedures for the determination of a variety of substituted phenols in water samples are described. The phenols were extracted or extracted-derivatized by using a continuous liquid-liquid extraction-derivatization system and quantified with flame ionization detection. Ethyl acetate was found to be the most efficient solvent for phenols whereas n-hexane yielded essentially the same recoveries for derivatized phenols. Between 0.1 and 300 mg/l of the different phenols can be detected with a relative standard deviation 1.1 and 3.7%. The acetate esters of six phenols were formed by the direct addition of acetic anhydride to the organic extractant. The stable acetate esters thus formed were isolated by using a standard dimethyl polysiloxane gas chromatographic column.

Chlorophenols↗

[Measurement of spontaneous motility in vitro of the cervical ring in sheep].

Spontaneous motility has been observed within in vitro preparations by different annulars of the cervix, as well as the characteristics shown this structure. This motor activity is cyclic, amplitude and tone not changing from some annulars to others, working on two grammes tension, but frequency and rhythm show large changes, altering the frequency from 7.3 contractions to minute in the first annular to 4.05 in the fifth annular. However, there appears denticulate peaks, with an incidence of 11% in the first annular, growing to 100% in the fifth annular.

Animals↗

[Spontaneous motility and contractile response of the sheep omasum (author's transl)].

Spontaneous motility of the sheep omasum longitudinal muscular layer its responses to the periarterial and transmural electric stimulus have been studied in vitro. Three parts of the organ were chosen: a) the greater curvatura; b) omasum lateral wall, and c) omasum canal. The preparations always showed a great spontaneous motility with elevated contractions followed by relaxations. The electric stimulation caused contractile responses followed by relaxation. The lesser the spontaneous motility, the greater becomes the response, which disappears when the spontaneous motility is very high.

Animals↗