PubMed Health⌕ Search

Biomedical subjects

E Baltussen

Publications and source records attributed to E Baltussen.

6 recordsLinked to original sources

Sorptive sample preparation -- a review.

Most sample-enrichment procedures currently available rely on adsorption of the analytes of interest by a suitable adsorbent material. Although good performance can be obtained for many practical problems, in some cases the applicability of adsorptive sample preparation falls short, particularly for the enrichment of polar and/or high-molecular-weight compounds, especially in combination with thermal desorption. Because of the very strong retention of adsorbent materials, undesired effects such as incomplete desorption and artifact formation are observed. Polar solutes are easily adsorbed but readily undergo surface-catalyzed reactions and on desorption yield compounds different than those originally sampled. High-molecular-weight compounds cannot be desorbed because of extremely strong interactions with the adsorbent and their low volatility. To overcome some of these problems sample-preparation techniques based on polydimethylsiloxane sorption have been developed over the past 15 years. In contrast with adsorptive trapping, sorption is based on dissolution of the analytes in a liquid polymeric material. This is a much more inert means of solute retention which overcomes some of the limitations encountered when working with adsorbents. In this contribution, the basic principles of sorption, the different instrumentation used, and applications of the technique will be reviewed. The review covers the sorptive sample-preparation techniques, open-tubular trapping (OTT), solid-phase microextraction (SPME), gum-phase extraction (GPE), equilibrium gum-phase extraction (EGPE), and stir-bar-sorptive extraction (SBSE). Because of the nature of sorptive sample-preparation techniques, which perform particularly well in combination with thermal desorption, this review focuses strongly on gas chromatography as the means of chemical analysis.

Chromatography, Gas↗

New approaches for fabrication of microfluidic capillary electrophoresis devices with on-chip conductivity detection.

In practice, microfluidic systems are based on the principles of capillary electrophoresis (CE), for a large part due to the simplicity of electroosmotic pumping. In this contribution, a universal conductivity detector is presented that allows detection of charged species down to the microM level. Additionally, powderblasting is presented as a novel technique for direct etching of microfluidic networks. This method allows creation of features down to 50 microm with a total processing time (design to device) of less than one day. The performance of powderblasted devices with integrated conductivity detection is illustrated by the separation of lithium, sodium, and potassium ions and that of fumaric, malic, and citric acid.

Acids↗

Capillary electrophoresis with on-chip four-electrode capacitively coupled conductivity detection for application in bioanalysis.

Microchip capillary electrophoresis (CE) with integrated four-electrode capacitively coupled conductivity detection is presented. Conductivity detection is a universal detection technique that is relatively independent on the detection pathlength and, especially important for chip-based analysis, is compatible with miniaturization and on-chip integration. The glass microchip structure consists of a 6 cm etched channel (20 microm x 70 microm cross section) with silicon nitride covered walls. In the channel, a 30 nm thick silicon carbide layer covers the electrodes to enable capacitive coupling with the liquid inside the channel as well as to prevent interference of the applied separation field. The detector response was found to be linear over the concentration range from 20 microM up to 2 mM. Detection limits were at the low microM level. Separation of two short peptides with a pI of respectively 5.38 and 4.87 at the 1 mM level demonstrates the applicability for biochemical analysis. At a relatively low separation field strength (50 V/cm) plate numbers in the order of 3500 were achieved. Results obtained with the microdevice compared well with those obtained in a bench scale CE instrument using UV detection under similar conditions.

Calibration↗

Recent advances in affinity capillary electrophoresis.

Use of the specificity of (bio)interactions can effectively overcome the selectivity limitation faced in capillary electrophoresis (CE), and the resulting technique usually is referred to as affinity capillary electrophoresis (ACE). Despite the high selectivity of ACE, several important problems still need to be addressed. A major issue in all CE separations, including ACE, is the concentration detection limit. Using UV detection, this is usually in the order of 10(-6) M whereas laser-induced fluorescence (LIF) detection can provide detection limits down to the sub-10(-10) M range. However, a marked disadvantage of LIF is that labeling of the analytes is usually required, which might change the interaction behavior of the solutes under investigation. Additionally, labeling reactions at sub-10(-10) M concentration levels are certainly not trivial and often difficult to perform quantitatively. Alternative and universal detection approaches, particularly mass spectrometric (MS) detection, look very promising but (A) CE-MS techniques are still far from routine application. Important future progress in sensitive detection strategies is likely to increase the use of ACE in the future.

Electrophoresis, Capillary↗

On the performance and inertness of different materials used for the enrichment of sulfur compounds from air and gaseous samples.

The performance of the sorbent polydimethylsiloxane (PDMS) is compared to that of the adsorbents Carbotrap and Tenax for the enrichment of volatile and reactive sulfur compounds. These included: 1- and 2-propanethiol, tetrahydrothiophene, 2-thioethanol and 2-ethylthioethanol. Several artifact-forming reactions were identified on both Tenax and Carbotrap including: H2S elimination and dimerization of thiols. Additionally, permanent adsorption was also observed for heavier solutes. These effects are absent when PDMS is applied. This superior performance is explained by the absence of catalytic or adsorptive activity on PDMS.

Adsorption↗

Determination of phenylurea herbicides in water samples using online sorptive preconcentration and high-performance liquid chromatography with UV or electrospray mass spectrometric detection.

A recently developed method for the extraction of organic micropollutants from aqueous samples based on sorptive enrichment in columns packed with 100% polydimethylsiloxane (PDMS) particles was coupled on-line with HPLC analysis. The sorptive enrichment procedure originally developed for relatively nonpolar analytes was used to preconcentrate polar phenylurea herbicides from aqueous samples. PDMS extraction columns of 5, 10 and 25 cm were used to extract the herbicides from distilled, tap and river water samples. A model that allows prediction of retention and breakthrough volumes is presented. Despite the essentially apolar nature of the PDMS material, it is possible to concentrate sample volumes up to 10 ml on PDMS cartridges without losses of the most polar analyte under investigation, fenuron. For less polar analytes significantly larger sample volumes can be applied. Since standard UV detection does not provide adequate selectivity for river water samples, an electrospray (ES)-MS instrument was used to determine phenylurea herbicides in a water sample from the river Dommel. Methoxuron was present at a level of 80 ng/l. The detection limit of the current set-up, using 10 ml water samples and ES-MS detection is 10 ng/l in river water samples. Strategies for further improvement of the detection limits are identified.

Chromatography, High Pressure Liquid↗