PubMed Health⌕ Search

Biomedical subjects

E Beccaloni

Publications and source records attributed to E Beccaloni.

7 recordsLinked to original sources

Determination of As in environmental solid matrix.

In line with recent European environmental guidelines on biomasses, one of the most important parameters to take into account is the As concentration, especially when present in biomasses and complex matrices. The goal of the present study is to give information about possible technical-analytical problems during the determinations of such elements by means of different instrumental spectroscopy techniques, in particular inductively coupled plasma atomic emission (ICP-AES) and atomic absorption (AAS), using two different wavelengths, 188.98 nm and 193.70 nm. In the Laboratory of Hygiene of National Institute of Health in Italy, a specific study has been carried out concerning the determination of As contents in environmental solid matrices, using as reference material BCR 141 R, represented by a calcareous soil. In particular, whereas recovery tests did not show particular drawbacks, difficulties were met in the As detection in reference material. Spectral interference was seen during determination by ICP-AES and matrix interference during determination by AAS, in particular using ETAAS with deuterium background correction and HAAS. Using ETAAS with Zeeman background correction at 193.70 nm, the As line did not show particular matrix interference during the reading of samples.A ring test involving two more laboratories and another certified reference material (IAEA-356 in marine sediment matrix) produced important information about problems of under/over estimation of data. Two different instrumental techniques, ICP-MS and HAAS, confirmed previous data, i.e., overestimation for inductively coupled plasma mass spectrometry and that As values achieved by HAAS were of the same order as the references, but affected by considerable standard deviation. In the light of this study, data achieved on the environmental matrices investigated suggest that the critical step in As determination is the instrumental reading, rather than the mineralization process. Further, each of the methods proposed, apart from ETAAS with Zeeman background correction, presents its own peculiar drawbacks and no particular advantage over other techniques.

Arsenic↗

Reference values for essential and toxic elements in human milk.

Dependable reference values (RVs) for the concentration ranges of health-related elements in human biological fluids and organs are to date of acknowledged importance for an early recognition of pathological states. On the other hand, the present lack of reliable data on levels to be considered as baseline values for elements of major concern from a toxicological, environmental and nutritional point of view demands the development of experimental procedures capable of satisfying the requirements of detection power, specificity and applicability on a large scale necessary to generate vast amounts of reliable measurements. As part of an overall monitoring program, an investigation was undertaken with the following two aims: a) the present suitability of inductively-coupled plasma atomic emission spectrometry (ICP-AES) to identify and quantitate minor and trace elements in human milk with the necessary accuracy and precision; b) assessment of RV concentrations for Al, Ba, Cd, Cr, Cu, Fe, Li, Mg, Mn, Ni, Pb and Zn. Four population groups were selected (each with 9 subjects) resulting from the various combinations of smokers and non-smokers from an urban or a rural environment. Strict eligibility criteria were adopted in order to select only women in good health, no known occupational exposure and whose nutritional habits could be described in detail. A scrupolous and systematic approach was adopted to minimize every possible source of elemental contamination from the sampling step onwards. Digestion of samples was attempted both with mixtures of strong acids and by resorting to acid-assisted mineralization in a microwave oven. Both methods were satisfactory for subsequent introduction into the torch of the ICP-AES system. The outcome of this pilot study gave the following median RVs for concentration (in mg/kg): Al, 0.14; Ba, 0.013; Cd, 0.002; Cr, 0.016; Cu, 0.40; Fe, 0.72; Li, 0.004; Mg, 29.4; Mn, 0.006; Ni, 0.05; Pb, 0.016; and Zn, 3.08.

Female↗

Selenium intake with diet in Italy: a pilot study.

Selenium is an element essential to man. The main environmental pathway of Se-exposure for the general population is through food. As is true for all essential elements, not only deficient but also excessive exposure results in adverse health effects. Between these extremes there is a range of safe and adequate Se intakes. In 1980 the Italian National Research Council recommended 50-200 micrograms/day as an interval adequate to meet nutritional requirements, being at the same time below the threshold of toxic effects. Therefore the evaluation of dietary Se intake has become very important. The purpose of this work is the estimation of dietary intakes of Se using data on the amount and composition of an average Italian diet. Complete meals from a factory canteen were analyzed and calculations of weekly intake of Se carried out. Analyses were performed by means of Inductively-coupled Plasma Atomic Emission Spectrometry. The results obtained, related to the average and indicative food consumption of Italian people, showed that the daily intake is well within the recommended range.

Diet↗

Criteria for reference value assessment of elements in human tissues.

The availability of updated and reliable reference values for elements in biological tissues and fluids plays a key role in the correct planning and performance of clinical, toxicological and environmental studies. The basic principles for a proper analytical approach in order to obtain such data are outlined. This in turn should significantly reduce the wide range of figures reported for most elements as "normal" intervals in the scientific literature. Some applications of these guidelines are illustrated in detail in the case of human lungs, liver and kidneys for which tentative reference values are assessed for a number of minor and trace elements, namely, Al, Ba, Cd, Cr, Cu, Li, Mg, Mn, Pb, Sr, V and Zn.

Humans↗

Reference values for elements of toxicological, clinical and environmental interest in hair of urban subjects.

A monitoring campaign has been undertaken to ascertain the reference concentration ranges for a number of minor and trace elements in hair of healthy urban subjects under age 15. An outline of criteria and methods lying at the root of a sound and reliable experimental approach are presented with special regard to such crucial steps as study planning, sampling, storing, pretreatment, analysis and evaluation of results. Determinations were carried out mainly by inductively-coupled plasma atomic emission spectrometry (ICP-AES) given the wide investigative potential and inherently multielemental character of this technique. The results obtained so far regard 100 youngsters allowing reference intervals for Al, As, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Mo, Ni, P, Pb, Se, Ti, V and Zn to be established for the population group tested. Finally, further developments of this activity are highlighted, particularly emphasizing the diagnostic capabilities of hair analysis.

Adult↗

Inductively coupled atomic emission spectrometry and neutron activation analysis for the determination of element reference values in human lung tissue.

An investigation was undertaken in order to assess the performance of neutron activation analysis and inductively coupled plasma atomic emission spectrometry techniques for determining reference values for minor and trace elements in human lungs of urban subjects. Results show that in both instances experimental conditions must be carefully optimized to guarantee reliability of experimental data. Strict criteria for tissue sampling and pretreatment also had to be set. Provisional reference values for ca. 50 elements could thus be established.

Animals↗

Arsenic and heavy metals in leachate from a real landfill and a laboratory landfill.

A preliminary study, based particularly on Arsenic and some heavy metals determination (Cd, Cr, Hg and Pb) in three leachate tipologies produced from municipal waste landfill plant, lab-scale aerobic landfill, lab-scale anerobic landfill was undertaken. Leachate was collected and analysed monthly; samples were homogenized and then, all heavy metals were determined after mineralization, except for Hg, determined before mineralization, due to his high volatility. In all samples pH was measured. In general we can say that low concentrations of the elements analyzed were found in all kinds of landfills considered; in particular, in the lab-scale anaerobic reactors, where low pH values have been found, we have a more considerable mobilization of As and the others heavy metals, moreover due to the behaviour of these elements.

Aerobiosis↗