New approach to preoperative autologous blood donation (PABD)
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to E Biffi.
Explore the source record for details and available documents.
We investigated the safety and efficacy of preoperative epoetin alfa used in conjunction with preoperative autologous blood donation (PAD) in 40 anemic orthopedic surgical patients undergoing hip replacement surgery [hematocrit (Hct) </=39%]. Patients were randomized 25-35 days before surgery to twice weekly intravenous (i. v.) epoetin alfa (300, 150, or 75 IU/kg) or placebo treatments supplemented with 200 mg i.v. iron. Epoetin alfa facilitated dose-dependent increases in PAD (4.3 units, 300 IU/kg; 3.4 units, 150 IU/kg; 3.0 units, 75 IU/kg; 2.1 units, placebo), and minimized reductions in Hct associated with repeated phlebotomy. All epoetin alfa doses were well tolerated and safe. Our results indicate that preoperative epoetin alfa dose-dependently stimulates erythropoiesis and facilitates PAD in anemic orthopedic patients, which may benefit patients by reducing their exposure to the risks of allogeneic transfusion, hastening recovery and discharge from hospital.
BACKGROUND AND OBJECTIVES: Intravenous (i.v.) Recombinant erythropoietin (Epoetin alfa) is effective in allowing autologous blood donation in patients unable to donate because of anemia. We undertook this open pilot study in order to asses whether a low subcutaneous (s.c.) dose of Epoetin alfa would prove as effective and well tolerated as the higher i.v. dose. Such a move would also decrease costs. MATERIALS AND METHODS: A total Epoetin alfa s.c. dose of 800 IU/kg was compared with a total i.v. dose of 1,800 IU/kg. Twenty-two rheumatoid arthritis patients, unable to donate because of hemoglobin (Hb) < 11 g/dl, received 300 IU/kg of IV Epoetin alfa twice weekly for 3 weeks (11 patients), or 100 IU/kg of s.c. Epoetin alfa twice weekly for 3 weeks plus an i.v. bolus of 200 IU/kg of Epoetin alfa at the first visit (11 patients). At each visit, all patients received 100 mg of i.v. iron saccharate and when the hematocrit (hct) > or = 34%, 350 ml of autologous blood (AB) were collected. RESULTS: No significant differences were observed between the 2 groups of treated patients in terms of units of AB collected (2.6 +/- 0.6 vs. 2.5 +/- 0.5 units for i.v. and s.c. groups, respectively), ml of RBC produced during the study period (291 +/- 99 vs. 337 +/- 65 ml for the i.v. and s.c. groups, respectively), or in the degree of reduced exposure to allogeneic blood in comparison with the control group. CONCLUSIONS: Lower dose of Epoetin alfa (reduced by 56%), supplemented by i.v. iron, is as effective and well tolerated as higher doses administered i.v., supplemented by i.v. iron.
Clerical errors occurring during specimen collection, issue and transfusion of blood are the most common cause of AB0 incompatible transfusions. 40-50% of the transfusion fatalities result from errors in properly identifying the patient or the blood components. The frequency and type of errors observed, despite the implementation of measures to prevent them, suggests that errors are inevitable unless major changes in procedures are adopted. A fail-safe system, which physically prevents the possibility of error, was adopted in January 1993 and concurrently a quality improvement program was implemented to monitor any transfusion errors. Up to December 1994, 10,995 blood units (5,057 autologous and 5,938 allogeneic) were transfused to 3,231 patients. Seventy-one methodological errors(1/155 units) were observed, half of which were concentrated during the first 4 months of introducing the system. However the system detected and avoided four potentially fatal errors (1/2,748 units). Two cases involved the interchanging of recipient sample tubes, 1 case was due to patient misidentification and the other involved misidentification of blood units. In conclusion the system is effective in detecting otherwise undiscovered errors in transfusion practice and can prevent potential transfusion-associated fatalities caused by misidentification of blood units or recipients.
A successful autologous blood program should enrol all appropriate patients, conserve homologous blood and minimize the exposure to the risks of donor blood. A program of autotransfusion and proper use of blood has been implemented since 1980 with the objectives of including all eligible patients and to transfuse autologous blood only. The following strategies were adopted: critical review of transfusion indications; control of over-transfusion; avoidance of waste; systematic and integrated use of all autotransfusion techniques currently available. Results in 1992 in elective surgery: 98% enrolment, 75% blood conservation. Exposure to homologous blood was completely avoided in 53% of the cases.
UNLABELLED: Human error in patient or specimen identification due to fatigue, stress and lack of attention by technologists, nurses, interns, and physicians, can cause routinely safety procedures to be circumvented. Clerical errors may occur during the specimen collection, the issue of blood unit and the transfusion of blood. The introduction in an increasing number of hospital of preoperative autologous blood donation programs further increases the chance of error, because a single patient can predeposit multiple units of blood. In this cases there is a greater commitment not only to transfuse any blood unit that is ABO compatible but to transfuse the specific units the patient previously donated for his own use. Human error has been recognized as a significant cause of transfusion-associated fatalities. The persistence of the frequency and type of errors observed in spite of extensive efforts to eradicate them, suggests that errors are inevitable as long as large number of repetitive procedures are performed unless major system changes are adopted. A system (Bloodloc System) that physically prevents the possibility of error was adopted since January 1993 and cuncurrently a quality improvement program (QI) was implemented specifically designed to monitor: 1. the absence of the code on the blood samples, 2. the blood bank error in setting the Bloodloc, 3. the misidentification of blood samples, 4. any attempt to transfuse the wrong blood unit, 5. any attempt to transfuse, the wrong patients. RESULTS: 4895 blood units (2469 autologous and 2426 allogeneic units) were transfused to 1478 patients (849 predeposited an average of 3.3 +/- 2.0 units). The methodological errors (absence of three-letter code on the patient's specimen tube, wrong transcription of the code on the blood sample, wrong setting of the Bloodloc in the blood bank)--41 cases--were limited at the first four months of implementation of the system. In the same period however have been reported 3 potentially fatal errors which have been avoided by the Bloodloc. Two cases of misidentification of blood samples at the moment of the specimen collection, and one attempt to transfuse the wrong units to the wrong patients. CONCLUSIONS: The Bloodloc system is effective in preventing potential transfusion-associated fatalities caused by units or recipients misidentification.
BACKGROUND: In rheumatoid arthritis (RA) patients undergoing orthopedic surgery, anemia is the major factor in the use of allogeneic blood. STUDY DESIGN AND METHODS: To determine whether recombinant human erythropoietin (rHuEPO) could allow preoperative autologous blood procurement and reduce allogeneic blood exposure, 11 RA patients who were unable preoperatively to deposit blood for autologous use because of their anemia (baseline hematocrit < 34% [0.34]) and who were scheduled for primary total hip replacement or total knee replacement were treated intravenously with 300 U per kg of rHuEPO in combination with intravenous iron saccharate (100 mg), given twice weekly for 3 weeks. The transfusion treatment was compared with that in 12 control patients with comparable baseline hematologic values who underwent the same operation. RESULTS: Control patients could not preoperatively deposit any blood for autologous use, while all but one of the rHuEPO-treated patients deposited 2 or more units (mean, 2.6 +/- 0.6; range, 2-4) (p < 0.001). The control group received more allogeneic units (2.6 +/- 1.6 vs. 0.8 +/- 0.8) (p = 0.009). Moreover, 50 percent of the rHuEPO-treated patients, as compared with 8 percent of controls, completely avoided allogeneic transfusion. CONCLUSION: Recombinant human erythropoietin is safe and effective in stimulating erythropoiesis, allowing preoperative donation of blood for autologous use, and reducing exposure to allogeneic blood for RA patients who are unable preoperatively to deposit blood because of anemia.
For surgical patients transfusion of autologous blood (AB) is the most useful of measures to reduce patient's exposure to homologous blood (HB). In our Institute an autotransfusion program was started in 1982 utilizing all the autotransfusion techniques currently available. The integrated use of the techniques offered to the majority of the patients the possibility of receiving AB (98% of the elective surgery patients) and a consistent conservation of HB has been achieved (60-70%). However 42% are still exposed to some HB. Critical parameters that render the patients unable to fulfill the anticipated transfusion needs with the current AB transfusion techniques are: the patient's ability to predonate sufficient AB prior to surgery and the amount of blood transfused intraoperatively that in turn depends on different "transfusion trigger". In our Institute over 50% of all the blood units are transfused the day of operation (60% being AB, 40% HB) and 50% postoperatively (only 33% being AB). For this reason, a clinical application for the oxygen-carrying products can be the replacement of the blood lost during, or immediately after the operation permitting the surgeon to operate safely at a lower Hct levels, thereby delaying the transfusion of blood and saving the AB obtained.
Explore the source record for details and available documents.
For patients who donate blood for autologous use and undergo major orthopedic surgery, low basal hematocrit (Hct) is the major cause of allogeneic blood exposure. To determine whether recombinant human erythropoietin (rHuEPO) could increase autologous blood procurement and reduce allogeneic blood exposure, a prospective randomized study was conducted in 50 women undergoing total hip replacement who had basal Hct < 40 percent (0.40). Patients were randomly placed in three groups: those receiving placebo, those receiving 300 U of rHuEPO per kg, and those receiving 600 U of rHuEPO per kg every 3 to 4 days for 21 days. Oral iron (125-270 mg/day) was given; in the last 24 patients, 100 mg of iron saccharate was administered intravenously at each donation. At each visit, 350 mL of blood was collected if Hct was > or = 34 percent (0.34). Patients receiving rHuEPO donated a greater amount of blood for autologous use than did patients in the placebo group (4.5 +/- 1.1 vs. 2.8 +/- 0.6 units; p < 0.05) and received a significantly lower amount of allogeneic blood (1.2 +/- 1.4 vs. 0.4 +/- 0.8 units; p < 0.05). No difference between the effects of the two doses of rHuEPO was observed. Iron support was a critical factor in the efficacy of treatment. No untoward effects were observed. The rHuEPO emerged as a safe and effective treatment, with adequate iron support, by which to increase preoperative deposit of autologous blood and to reduce exposure to allogeneic blood for patients with low basal Hct.
A successful autologous program should enroll all appropriate patients, conserve homologous blood and minimise the exposure to the risks of donor blood. A program of autotransfusion and proper use of blood has been implemented since 1980 with the objectives to include all eligible patients and to transfuse autologous blood only. The following strategies were adopted: critical review of transfusion indications; control of overtransfusion; avoidance of waste; systematic and integrated use of all autotransfusion techniques currently available. Results in 1992 in elective surgery: 98% enrollment, 75% blood conservation. Exposure to homologous blood was completely avoided in 53% of the cases.
Explore the source record for details and available documents.
Previous studies have shown that neurotensin (NT) administered intracerebroventricularly (i.c.v.) to rats provokes an inhibition of intestinal propulsion linearly related to the log of administered doses. In the present study it is demonstrated that, in contrast to morphine, repeated i.c.v. administrations of NT (2.5 nmol/rat/day) did not result in tolerance to the intestinal effect. Naloxone (Nx) administered i.c.v. fully antagonized the intestinal inhibition of i.c.v. morphine, but did not significantly alter the NT effect. However, centrally administered thyrotropin-releasing hormone (TRH) inhibited NT-induced (but not morphine-induced) intestinal inhibition. Direct microinjections of NT into the periaqueductal gray matter (PAG) produced complete inhibition of intestinal propulsion when the microinjections were localized in the dorsal portion. Finally, subdiaphragmatic vagotomy totally abolished the inhibition induced by NT into the PAG, while morphine was not affected. Some considerations are put forward concerning the existence in the central nervous system of a peptidergic pathway modulating intestinal function.
12 patients (9 males, 3 females; aged 35-63 years, mean 55) with chronic obstructive pulmonary disease (COPD) were studied in order to determine the correlation between the values of pulmonary arterial pressure and the M-mode echographic size of the right pulmonary artery (RPA) from the subxiphoid approach. Both the largest (systolic) and smallest (diastolic) size of the vessel were considered, and both were corrected for body surface area ('index size' - PA/BSA). The reliability of this echographic size is supported by the evidence that the tract of the pulmonary artery considered in this study is perpendicular to the ultrasonic beam. Both the systolic and diastolic size of RPA correlated with the systolic, diastolic, and mean pulmonary arterial pressure, detected by catheterization. Measurements of RPA size were made from the suprasternal approach in 8 patients out of 12. The size of RPA from the subxiphoid approach was also estimated in 21 normal subjects, serving as controls. Measurements of RPA size from the suprasternal approach were made in 12 of these subjects. Both the systolic and diastolic size of RPA from the subxiphoid approach correlated with the systolic and diastolic size of the suprasternal view in patients and in normal subjects. Subxiphoid M-mode echocardiography seems to be a valuable noninvasive technique in assessment of pulmonary hypertension, particularly in patients affected by COPD.
In this paper, a new echocardiographic detection technique of the VP in patients with CPC is described. Subjects who frequently have large, barrel chests, with pulmonary emphysema and markedly depressed diaphragms, are very difficult to examine echocardiographically. By this technique, however, the authors obtained the highest detection rate so far reported (congruent to 100% of the patients studied). Moreover, the echocardiographic findings are validated by an ultrasonic anatomy study based on the use of Cardio Green (V.I.) as contrast agent.
Explore the source record for details and available documents.