PubMed HealthSearch

Biomedical subjects

E Bosak

Publications and source records attributed to E Bosak.

2 recordsLinked to original sources

Automatic assessment of cardiac function from short-axis MRI: procedure and clinical evaluation.

Cardiac magnetic resonance imaging (MRI) provides a wealth of morphological and physiological information. Automatic extraction of this information is possible by implementing various image processing techniques. However, existing procedures mostly rely on extensive human interaction and are seldom evaluated on a clinical scale. In this study, a nearly automatic process that extracts physiological parameters from cardiac MR images has been both developed and clinically evaluated. Raw images were obtained in the short-axis view and acquired by a gradient-cho (GE) protocol. In images selected to be analyzed, the only manual step required is the indication of a point in the center of the left ventricle (LV). From a set of such images, the process extracts endocardial and epicardial contours and calculates left ventricular volumes, mass and ejection fraction (EF). The process implements novel approaches to image processing techniques such as thresholding and shape extraction and can be adapted to other acquisition protocols. The process has demonstrated a clear potential for accurate extraction of the endocardial contour but a lower one with respect to the epicardial contour as a result of the low contrast between myocardium and some surrounding tissues, generated by the gradient-echo protocol. The ability of the process to asses physiological parameters has been subjected to a systematic clinical evaluation, which compared parameters, derived manually and automatically, in 10 healthy subjects and 10 patients. The evaluation has indicated that although individual volumes and mass were not accurately assessed, the automatic process has shown high potential for assessing the ejection fraction with relatively high accuracy and reliability.

Adult

A new diffusion SSFP imaging technique.

In this paper a new diffusion sensitive steady-state free precession (SSFP) pulse sequence with a reduced sensitivity to physiological brain motion is presented. The signal attenuation due to diffusion in this SSFP sequence is derived theoretically and confirmed experimentally with a phantom. It is shown that for brain tissue this signal attenuation is approximately independent of T1 and T2, but depends only on the pulse sequence used, i.e., the timing and the size of the RF and the gradient pulses. On this basis the diffusion constant can be calculated for any region in the image. Diffusion sensitive images of the brain obtained with our pulse sequence are presented and shown to be superior over an image obtained with a "conventional" diffusion sensitive SSFP sequence.

Brain