Experimental three dimensional strain estimation from ultrasonic sectorial data.

Most of the studies devoted to elastography are focused on the estimation of the axial component of the strain. However when subjected to any load, whatever the direction, soft biological media deform in the three spatial dimensions. The aim of our work is to build a three dimensional strain mapping from data acquired with a 3D clinical sectorial probe. The estimation of radial strain is based on the estimation of local scaling factors. A method of cross-correlation of interpolated signals between adjacent radiofrequency lines was used to estimate the angular displacement and strain. For the sectorial strain estimation, the same displacement estimation technique has been implemented. The method has been tested on experimental data acquired on calibrated phantoms and compared to simulation.

Algorithms↗

Axial strain imaging of intravascular data: results on polyvinyl alcohol cryogel phantoms and carotid artery.

Mapping the local elastic properties of an atherosclerotic artery is of major interest for predicting the disease evolution or an intervention outcome. These properties can be investigated by elastography, which estimates the strain distribution within a medium in response to a stress. But because diseased arteries are highly heterogeneous, a small global deformation may result in high local strains in the softest regions. For those reasons, we use in this paper the strain estimation method we recently developed to compute elastograms of original vessel-mimicking cryogel phantoms and a fresh excised human carotid artery. This adaptive method has been effectively proved to be accurate in a wider range of strains (0-7%) than commonly used gradient-based methods, and very adapted for investigating highly heterogeneous tissues. Resulting elastograms cover a wider range of strains (0-3.5%) than all previously reported intravascular elastograms, improving the discrimination between healthy and diseased regions.

Carotid Artery Diseases↗

Synthetic aperture-based beam compression for intravascular ultrasound imaging.

In this paper, intravascular ultrasound (IVUS) images acquired with a 64-element array transducer using a multistatic acquisition scheme are presented. The images are reconstructed from a collection of pulse-echo measurements using a synthetic aperture array imaging technique. The main limitations of IVUS imaging are a poor lateral resolution and elevated grating lobes caused by the imaging geometry. We propose a Synthetic Aperture Focusing Technique (SAFT), which uses a limited number of A-scan signals. The focusing process, which is performed in the Fourier domain, requires far less computation time than conventional delay-and-sum methods. Two different reconstruction kernel functions have been derived and are compared for the processing of experimental data.

Computer Simulation↗

Axial strain imaging using a local estimation of the scaling factor from RF ultrasound signals.

The main signal-processing techniques used in elastography compute strains as the displacement derivative. They perform well for very low deformations, but suffer rapidly from decorrelation noise. Aiming to increase the range of accurate strain measurements, we developed an adaptive method based on the estimation of strains as local scaling factors. Its adaptability makes this method appropriate for computing scaling factors resulting from larger strains or a wide spread of strain variations. First, segments corresponding to the same part of tissue are adaptively selected in the rest and stressed state echo signals. Then, local scaling factors are estimated by iteratively varying their values until reaching the zero of the phase of the complex cross-correlation function. Results from simulation and from experimental data are presented. They show how this adaptive method can track various local deformations and its accuracy for strain up to 7%.

Algorithms↗

Mode switch despite undersensing of atrial fibrillation in DDD pacing.

UNLABELLED: Mode switching algorithms are commonly used to protect the ventricles against high rates induced by atrial tachycardia. In the case of atrial fibrillation (AF), the response of these algorithms depends on the quality of atrial sensing. The Chorum 7234 DDDR pacemaker uses a new mode switching algorithm, based on a statistical analysis of the atrial rhythm. It includes two criteria of diagnosis: "high" if more than 28 of 32 cycles are abnormally accelerated; and "low" if more than 36 of 64 cycles are abnormally accelerated. METHODS: From a taped database of electrophysiological studies, episodes of AF lasting more than 2 minutes were selected. A tape recorder replayed the atrial signals into an external Chorum device. Each episode was replayed eight times with a programmed atrial sensitivity increasing from 0.4-2.0 mV. For each criterion of diagnosis and each programmed sensitivity, the percentage of atrial sensing, the time to switching, and the mean ventricular rate were measured. Ten episodes of AF from 10 patients (9 men and 1 woman; ages 62 +/- 16 years) were included: 1.95 +/- 0.97 mV and 196 +/- 64 ms. The sensitivity of the algorithm to diagnose atrial tachycardia reached 100%, for an atrial sensitivity set between 0.4 and 1.0 mV. The mean percentages of atrial sensed events were 74% +/- 18% and 46% +/- 9% for the "high" and "low" criteria, respectively. The mean diagnostic times were 28 +/- 26 seconds and 68 +/- 27 seconds, respectively. Sensing of < 23% of AF events resulted in failure to diagnose the arrhythmias by both algorithms. In the event of diagnostic failure, the mean ventricular pacing rate was 79 +/- 9 ppm. CONCLUSION: Up to an atrial sensitivity of 1 mV, 100% of AF episodes were diagnosed. The Chorum mode switching algorithms are 100% reliable if > 45% of the AF waves are sensed. In the event of switching failure, the ventricle is protected by an average rate remaining below 80 ppm.

Acceleration↗