PubMed Health⌕ Search

Biomedical subjects

E C Hamilton

Publications and source records attributed to E C Hamilton.

5 recordsLinked to original sources

Clinical predictors of leak after laparoscopic Roux-en-Y gastric bypass for morbid obesity.

BACKGROUND: Gastrointestinal leak is a complication of laparoscopic Roux-en-Y gastric bypass (LRYGB). Contrast studies may underdiagnose leaks, forcing surgeons to rely solely on clinical data. This study was designed to evaluate various clinical signs for detecting leakage after LRYGB. METHODS: We retrospectively reviewed 210 consecutive patients who underwent LRYGB between April 1999 and September 2001. There were nine documented leaks (4.3%). Clinical signs between patients with leaks (group 1) and those without leaks (group 2) were compared using univariate and multivariate logistic regression analysis. RESULTS: Evidence of respiratory distress and a heart rate exceeding 120 beats per min were the two most sensitive indicators of gastrointestinal leak. Routine upper gastrointestinal contrast imaging detected only two of nine leaks (22%). CONCLUSION: Leak after LRYGB may be difficult to detect. Evidence of respiratory distress and tachycardia exceeding 120 beats per min may be the most useful clinical indicators of leak after laparoscopic Roux-en-Y gastric bypass.

Adult↗

Surgeon workload and motion efficiency with robot and human laparoscopic camera control.

BACKGROUND: Surgeons are now being assisted by robotic systems in a wide range of laparoscopic procedures. Some reports have suggested that robot-assisted camera control (RACC) may be superior to a human driver in terms of quality of view and directional precision, as well as long-term cost savings. Therefore, we setout to investigate the impact of RACC of surgeon motion efficiency. METHODS: Twenty pigs were randomized to undergo a standardized laparoscopic Nissen fundoplication with either a human or RACC system, the AESOP 2000. All procedures were performed by the same surgical fellow. Time was recorded for dissection and suture phases. Inertial motion sensors were used to monitor both the surgeon's hands and the camera. Digitized data were analyzed to produce summary measures related to overall motion. RESULTS: The operative times were slightly longer with RACC (mean 80.2 +/- 20.6 vs 73.1 +/- 15.4 min, not significant). With regard to operative times and surgeon motion measures, the only statistically significant differences were for setup and breakdown times, which contributed <15% to the total time for the procedure. CONCLUSION: In terms of impact on surgeon motion efficiency and operative time under normal surgical conditions, RACC is essentially the same as an expert human driver. However, careful planning and structuring of the surgical suite may yield some small gains in operative time.

Animals↗

Comparison of video trainer and virtual reality training systems on acquisition of laparoscopic skills.

Training on a video trainer or computer-based minimally invasive surgery trainer leads to improved benchtop laparoscopic skill. Recently, improved operative performance from practice on a video trainer was reported. The purpose of this study was three fold: (a) to compare psychomotor skill improvement after training on a virtual reality (VR) system with that after training on a video-trainer, (VT) (b) to evaluate whether skills learned on the one training system are transferable to the other, and (c) to evaluate whether VR or VT training improves operative performance. For the study, 50 junior surgery residents completed baseline skill testing on both the VR and VT systems. These subjects then were randomized to either a VR or VT structured training group. After practice, the subjects were tested again on their VR and VT skills. To assess the effect of practice on operative performance, all second-year residents (n = 19) were evaluated on their operative performance during a laparoscopic cholecystectomy before and after skill training. Data are expressed as percentage of improvement in mean score/time. Analysis was performed by Student's paired t-test. The VR training group showed improvement of 54% on the VR posttest, as compared with 55% improvement by the VT group. The VR training group improved more on the VT posttest tasks (36%) than the VT training group improved on the VR posttest tasks (17%) (p <0.05). Operative performance improved only in the VR training group (p <0.05). Psychomotor skills improve after training on both VR and VT, and skills may be transferable. Furthermore, training on a minimally invasive surgery trainer, virtual reality system may improve operative performance during laparoscopic cholecystectomy.

Animals↗

Improving operative performance using a laparoscopic hernia simulator.

BACKGROUND: Traditionally, the acquisition of surgical skill has occurred entirely in the operating room. To meet the expanding challenges of cost containment and patient safety, novel methods of surgical training utilizing ex-vivo workstations are being developed. The purpose of our study was to evaluate the impact of a laparoscopic training curriculum on surgical residents' operative performance. METHODS: Twenty-one surgery residents completed baseline laparoscopic total extraperitoneal (TEP) hernia repairs. Operative performance was evaluated using a validated global assessment tool. Each resident was then randomized to a control group or a trained group. A CD ROM, video, and simulator were used for training. At the end of the study, each resident's operative performance was again evaluated. RESULTS: Improvement was significantly greater in the trained group in five of the eight individual global assessment areas as well as the composite score (P <0.05). Questionnaire data suggested that training resulted in improved understanding of the TEP hernia repair (P = 0.01) and an increased willingness to offer the operation to patients with nonrecurrent unilateral hernias (P = 0.02). CONCLUSIONS: A multimodality laparoscopic TEP hernia curriculum improves residents' knowledge of the TEP hernia repair and comfort in performing the procedure, and may also improve actual operative performance.

Clinical Competence↗

Significant reversal of thyrotoxicosis-associated dilated cardiomyopathy with induction of the euthyroid state.

Thyrotoxicosis rarely precipitates heart failure. Older patients and those with underlying cardiac disease are at greater risk of experiencing this complication of thyrotoxicosis. A 43 year old male who presented with subclinical thyrotoxicosis, atrial fibrillation, and a dilated cardiomyopathy is discussed. There was no evidence of clinically significant underlying cardiac disease. At admission, the patient had an ejection fraction of 25%. Thyrotoxicosis was treated with propylthiouracil. At 14 weeks after hospitalization, the patient had an ejection fraction of 50% with significant reduction in cardiac chamber sizes and left ventricular mass index. He was biochemically euthyroid at that time. After ten months of propylthiouracil therapy, he had progressive improvement in cardiac function and decrease in left ventricular mass index. Thyrotoxicosis-associated cardiomyopathy may reverse significantly with treatment of thyrotoxicosis alone; this complication of thyrotoxicosis should be considered in any young individual with a dilated cardiomyopathy of unknown etiology.

Adult↗