PubMed Health⌕ Search

Biomedical subjects

E Carrilho

Publications and source records attributed to E Carrilho.

10 recordsLinked to original sources

DNA sequencing by capillary array electrophoresis and microfabricated array systems.

To comply with the current needs for high-speed DNA sequencing analysis, several instruments and innovative technologies have been introduced by several groups in recent years. This review article discusses and compares the issues regarding high-throughput DNA sequencing by electrophoretic methods in miniaturized systems, such as capillaries, capillary arrays, and microchannels. Initially, general features of several capillary array designs (including commercial ones) will be considered, followed by similar analyses with microfabricated array electrophoretic devices and how they can contribute to the success of large sequencing projects.

Animals↗

Routine DNA sequencing of 1000 bases in less than one hour by capillary electrophoresis with replaceable linear polyacrylamide solutions.

Long, accurate reads are an important factor for high-throughput de novo DNA sequencing. In previous work from this laboratory, a separation matrix of high-weight-average molecular mass (HMM) linear polyacrylamide (LPA) at a concentration of 2% (w/w) was used to separate 1000 bases of DNA sequence in 80 min with an accuracy close to 97% (Carrilho, E.; et al. Anal. Chem. 1996, 68, 3305-3313). In the present work, significantly improved speed and sequencing accuracy have been achieved by further optimization of factors affecting electrophoretic separation and data processing. A replaceable matrix containing a mixture of 2.0% (w/w) HMM (9 MDa) and 0.5% (w/w) low-weight-average molecular mass (50 kDa) LPA was employed to enhance the separation of DNA sequencing fragments in CE. Experimental conditions, such as electric field strength and column temperature, as well as internal diameter of the capillary column, have been optimized for this mixed separation matrix. Under these conditions, in combination with energy-transfer (BigDye) dye-labeled primers for high signal-to-noise ratio and a newly developed expert system for base calling, the electrophoretic separation of 1000 DNA sequencing fragments of both standard (M13mp18) and cloned single-stranded templates from human chromosome 17 could be routinely achieved in less than 55 min, with a base-calling accuracy between 98 and 99%. Identical read length, accuracy, and migration time were achieved in more than 300 consecutive runs in a single column.

Acrylic Resins↗

A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. A. Development of the cleanup protocol.

A method for the cleanup of Sanger DNA sequencing reaction products for capillary electrophoresis analysis with replaceable polymer solutions has been developed. A poly(ether sulfone) ultrafiltration membrane pretreated with linear polyacrylamide was first used to remove template DNA from the sequencing samples. Then, gel filtration in a spin column format (two columns per sample) was employed to decrease the concentration of salts below 10 microM in the sample solution. The method was very reproducible and increased the injected amount of the sequencing fragments 10-50-fold compared to traditional cleanup protocols. Using M13mp18 as template, the resulting cleaned-up single DNA sequencing fragments could routinely be separated to more than 1000 bases with a base-calling accuracy of at least 99% for 800 bases. The method is simple and universal and can be easily automated. In the following paper, a systematic study to determine quantitatively the effects of the sample solution components such as high-mobility ions (e.g., chloride and dideoxynucleotides) and template DNA on the injected amount and separation efficiency of the sequencing fragments is presented.

Base Sequence↗

A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. B. Quantitative determination of the role of sample matrix components on sequencing analysis.

In the previous paper, a sample cleanup procedure for DNA sequencing reaction products was developed, in which template DNA was removed by ultrafiltration and the total concentration of salts (chloride and di- and deoxynucleotides) was decreased below 10 microM using gel filtration. In this paper, a quantitative study of the effects of these sample solution components on the injected amount and separation efficiency of the sequencing fragments in capillary electrophoresis is presented. The presence of chloride and deoxynucleotides in a total concentration above 10 microM in the sample solution significantly decreased the amount of DNA sequencing fragments injected into the capillary column. However, the separation efficiency was not affected upon increasing the amount of salt. On the other hand, in the presence of only 0.1 microgram of template in the sample (one-third of the lowest quantity recommended in cycle sequencing) and at very low chloride concentration (approximately 5 microM), the separation efficiency decreased by 70%, and the injected amount of DNA sequencing fragments was 40% lower compared to the sample cleaned by the new purification method. The deleterious effect of template DNA on the separation of sequencing fragments was suppressed in the presence of salt in a concentration above 100 microM in the sample solution. Separately, it was found that both the electric field strength and duration of injection affected the resolution of DNA sequencing fragments when the cleaned up sample solution was used. Separation efficiencies of 15 x 10(6) theoretical plates/m were achieved when the sample was loaded at low electric field, e.g., 25 V/cm for 80 s or less. The results demonstrate that the sample solution components (chloride, deoxynucleotides, template DNA) and injection conditions must be controlled to achieve high performance and rugged DNA sequencing analysis.

Chlorides↗

Characterization of high molecular mass linear polyacrylamide powder prepared by emulsion polymerization as a replaceable polymer matrix for DNA sequencing by capillary electrophoresis.

In a previous paper, a 2% w/w replaceable high molecular mass linear polyacrylamide solution (high molecular mass LPA) was used to achieve long read-lengths for DNA sequencing by capillary electrophoresis (E. Carrilho et al., Anal. Chem. 1996, 68, 3305-3313). In that work, the polymer was prepared by polymerization in water at 6% w/w, followed by dilution to 2% w/w. In this study, an improved method for preparation of high molecular mass LPA was developed, based on inverse emulsion polymerization. With this polymerization procedure, the LPA results in a molecular mass of approximately 9 MDa, with characteristics of a fine powder of high purity and practically unlimited shelf life. Using size exclusion chromatography (SEC) and viscosity measurements to characterize the polymer, good batch-to-batch reproducibility was found. It was observed that the viscous polymer solutions made from these high molecular mass polymers require careful preparation and handling because the method of dissolution could affect the molecular mass distribution and the resultant separation of DNA components. Solutions containing 2% w/w of LPA made by emulsion polymerization were simple to prepare, resulting in excellent performance as a replaceable matrix for DNA sequencing by capillary electrophoresis. The viscosity of the polymer decreased exponentially when pressure was applied, allowing easy replacement from a capillary using a syringe. With a properly prepared matrix, a read-length of more than 1000 bases in 80 min with an accuracy better than 97%, and better than 99% for the first 800 bases, could be achieved.

Acrylic Resins↗

Capillary electrophoresis for the detection of known point mutations by single-nucleotide primer extension and laser-induced fluorescence detection.

Capillary electrophoresis (CE) with laser-induced fluorescence (LIF) was used to detect known point mutations using the method of single-nucleotide primer extension (SNuPE). Three different point mutations in human mitochondrial DNA associated with Leber's hereditary optic neuropathy (LHON) were detected by annealing a primer immediately 5' to the mutation on the template and extending the primer by one fluorescently labeled dideoxy terminator complementary to the mutation. By using two or more differently labeled terminators, both the mutant and wild type could be simultaneously detected. The advantages of using CE-LIF for detecting SNuPE reactions include speed and ease of analysis, absence of radioactivity, and potential for automation.

Base Sequence↗

Missense mutation R1066C in the second transmembrane domain of CFTR causes a severe cystic fibrosis phenotype: study of 19 heterozygous and 2 homozygous patients.

We report the clinical features of 21 unrelated cystic fibrosis (CF) patients from Portugal and Spain, who carry the mutation R1066C in the CFTR gene. The current age of the patients was higher in the R1066C/any mutation group (P < 0.01), as compared to the deltaF508/deltaF508 group. Poor values for lung radiological involvement (Chrispin-Norman) and general status (Shwachman-Kulcycki) were observed in the R1066C/any mutation group (P < 0.005 and P < 0.0004). A slightly, but not significantly worse lung function was found in the R1066C/any mutation group when compared with the deltaF508/deltaF508 patients. No significant differences were detected regarding the age at diagnosis, sweat Cl-values, or percentiles of height and weight between the two groups. Neither were significant differences observed regarding sex, meconium ileus (4.7% vs. 11.1%), dehydration (10.5% vs. 14.7%), or pancreatic insufficiency (PI) (100% vs. 97.8%). The proportion of patients with lung colonization by bacterial pathogens was slightly, but not significantly higher in the R1066C/any mutation group (70.0%), as compared with the deltaF508/deltaF508 group (57.5%). Other clinical complications were significantly more frequent in the R1066C/any mutation patients(P < 0.02) than in the deltaF508/deltaF508 group. The two homozygous R1066C/R1066C patients died at the ages of 3 months and 7 years. The data presented in this study clearly demonstrate that the R1066C mutation is responsible for a severe phenotype similar to that observed in homozygous deltaF508 patients. The poor clinical scores and complications of patients with the R1066C mutation are probably related to their slightly longer survival.

Adolescent↗

Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions.

The read length for DNA sequencing using capillary electrophoresis and replaceable linear polyacrylamide (LPA) solutions has been extended to more than 1000 bases with a run time of 80 min. This result was successfully achieved through the combined use of cycle sequencing with dye-labeled primers, improved matrix and separation conditions, and enhanced base-calling software. The influences of LPA molecular weight and concentration on separation were investigated. Additionally, the separation buffer, column temperature, and electric field were adjusted to increase the number of resolvable DNA fragments per run while maintaining an enhanced separation speed. Using low concentrations [2% (w/v)] of high molecular weight LPA polymers (> 5.5 x 10(6) Da), elevated column temperature (50 degrees C) and moderately high field (150 V/cm), rapid sequencing analysis for more than 1000 bases on a model ssM13mp18 template was obtained with 96.8% accuracy.

Acrylic Resins↗

DNA sequencing by capillary electrophoresis using short oligonucleotide primer libraries.

Two strategies for DNA sequencing by primer walking using short oligonucleotide primer libraries have been successfully employed along with capillary electrophoresis using replaceable polymer solutions of linear polyacrylamide and fluorescence detection. A 3.5-kb stretch of the single-stranded M13mp18 template was sequenced with T7 PRISM dye-terminator/Sequenase chemistry. An in-house base-calling program offered read lengths of roughly 450 bases with an average of 97.8% accuracy.

Base Sequence↗

Characterization and performance of a neutral hydrophilic coating for the capillary electrophoretic separation of biopolymers.

Polyvinylmethylsiloxanediol (50% vinyl) was synthesized and combined with a cross-linker for static coating onto fused-silica columns. After cross-linking and binding to the surface, linear polyacrylamide was grafted to the double bonds of the siloxanediol; subsequently, this linear polymer matrix was cross-linked with formaldehyde. The grafted neutral polymeric layer provided suppression of electroosmotic flow and minimized adsorption. This combination yielded successful open tube and polymer network separations of proteins, peptides and DNA molecules. Very high efficiencies (ca. 1 x 10(6) plates/m) were achieved for open tube protein separations, and hundreds of consecutive runs were performed with minimal change in migration times.

Biopolymers↗