PubMed Health⌕ Search

Biomedical subjects

E Cavus

Publications and source records attributed to E Cavus.

6 recordsLinked to original sources

Comparison of LMA Unique, Ambu laryngeal mask and Soft Seal laryngeal mask during routine surgical procedures.

BACKGROUND AND OBJECTIVE: This study was performed to compare three disposable airway devices, the LMA Unique (LMA-U), the Ambu laryngeal mask (Ambu LM) and the Soft Seal laryngeal mask (Soft Seal LM) for elective general anaesthesia during controlled ventilation in non-paralysed patients. METHODS: One hundred and twenty ASA I-III patients scheduled for routine minor obstetric surgery were randomly allocated to the LMA-U (n = 40), Ambu LM (n = 40) or Soft Seal LM (n = 40) groups, respectively. Patients were comparable with respect to weight and airway characteristics. A size 4 LMA was used in all patients and inserted by a single experienced anaesthesiologist. Oxygenation, overall success rate, insertion time, cuff pressure and resulting airway leak pressure were determined as well as a subjective assessment of handling and the incidence of sore throat, dysphagia and hoarseness. RESULTS: Time of insertion was shortest with the Ambu LM, while failure rates were comparable with the LMA-U, the Ambu LM and the Soft Seal LM (median 19 s; range 8-57 s; success rate 100% vs. 14; 8-35; 97% vs. 20; 12-46; 95%). Insertion was judged 'excellent' in 75% of patients in the LMA-U group, in 70% of patients in Ambu LM group and in 65% of patients in the Soft Seal LM group. There was no difference between devices with respect to postoperative airway morbidity at 6 h or 24 h following surgery. CONCLUSIONS: All three disposable devices were clinically suitable with respect to insertion times, success rates, oxygenation, airway and leak pressures, as well as to subjective handling and postoperative airway morbidity.

Air Pressure↗

Monitoring of cerebral oxygenation with near infrared spectroscopy and tissue oxygen partial pressure during cardiopulmonary resuscitation in pigs.

BACKGROUND AND OBJECTIVE: The present study was designed to compare cerebral oxygenation measured with near infrared spectroscopy and local brain tissue oxygen partial pressure, respectively, in pigs during cardiopulmonary resuscitation. Since tissue overlying the brain may have an impact on near infrared spectroscopy readings, we tested whether optode placement on intact skin or on the skull yielded comparable results. METHODS: Twelve healthy pigs were anaesthetized and subjected to continuous haemodynamic, near infrared spectroscopy and brain tissue oxygen partial pressure monitoring. After 4 min of untreated ventricular fibrillation, cardiopulmonary resuscitation was started and arginine vasopressin was administered repeatedly three times. Near infrared spectroscopy values recorded were both the tissue oxygenation index and the tissue haemoglobin index as well as relative changes of chromophores (haemoglobin and cytochrome oxidase). Four animals served as control and were measured with both near infrared spectroscopy optodes mounted on the intact skin of the forehead, while in the remaining eight animals, one near infrared spectroscopy optode was implanted directly on the skull. RESULTS: Near infrared spectroscopy readings at the skin or at the skull differed consistently throughout the study period. After arginine vasopressin administration, near infrared spectroscopy values at the different locations showed a transient dissociation. In contrast to near infrared spectroscopy measured on intact skin, near infrared spectroscopy readings obtained from skull showed a significant correlation to brain tissue oxygen partial pressure values (r = 0.67, P < 0.001). CONCLUSION: Near infrared spectroscopy readings obtained from skin and skull differed largely after vasopressor administration. Near infrared spectroscopy optode placement therefore may have an important influence on the tissue region investigated.

Animals↗

The influence of xenon on regulation of the autonomic nervous system in patients at high risk of perioperative cardiac complications.

BACKGROUND: As xenon anaesthesia (XE) does not produce haemodynamic depression its use may be of benefit in patients at high risk of intraoperative haemodynamic instability and perioperative cardiac complications. XE (n=22) was compared with total i.v. anaesthesia (TIVA, n=22) for differences in autonomic regulation, peri- and postoperative performance. METHODS: Patients undergoing abdominal aortic surgery were studied at five events: T1: baseline awake; T2: anaesthesia induction; T3: before aortic cross-clamping; T4: after aortic cross-clamping; T5: after aortic declamping. T3-T5: end-tidal xenon concentration 60 (5)%. Intraoperative analysis: heart rate, heart rate variability, blood pressure and cardiac output. Postoperative analysis: 24 h Holter ECG, intensive care unit and hospital stay, and patient's outcome after 6 months. RESULTS: XE in contrast to TIVA increased parasympathetic and decreased sympathetic activity. Median low to high frequency decreased significantly in the XE group after start of XE (P<0.05) and remained significantly lower during all events after start of XE as compared with TIVA (P=0.0001). After start of XE heart rate of these patients was significantly lower as compared with TIVA (P=0.04). Cardiac output increased significantly in TIVA after aortic declamping (P<0.05). Outcome parameters did not differ significantly between groups. CONCLUSIONS: XE patients demonstrated lower sympathetic and higher parasympathetic activity as compared with TIVA patients. This was reflected by significant differences in haemodynamics but did not correlate with a better postoperative outcome. Thus, it remains controversial whether XE provides benefits in high risk patients.

Aged↗

Changes of local brain tissue oxygen pressure after vasopressin during spontaneous circulation.

BACKGROUND: Brain tissue oxygen pressure (PbtO2) correlates to cerebral blood flow (CBF) during spontaneous circulation, with one important regulator being nitric oxide (NO). Although it is established that arginine vasopressin (AVP) improves CBF and global cerebral oxygenation during cardiopulmonary resuscitation, it is unknown whether similar beneficial effects are present during spontaneous circulation. The purpose of this study was to investigate the effects of AVP with and without pre-treatment with the NO synthase inhibitor N-omega-nitro-L-arginine methyl ester (L-NAME) on local brain tissue oxygenation in a beating heart model. METHODS: Following approval of the Animal Investigational Committee, nine healthy piglets underwent general anaesthesia, and were instrumented with a probe in the cerebral cortex to measure PbtO2. Each animal was assigned to receive AVP (0.4 U . kg(-1)), and after a wash-out period, L-NAME (25 mg x kg(-1) over 20 min) followed by AVP (0.4 U x kg(-1)). After each AVP administration, nitroglycerine (25 microg x kg(-1) over 1 min) as a NO donor was infused to test the vascular reactivity independently from NOS inhibition. FINDINGS: Three minutes after administration of AVP, PbtO2 increased significantly (P < .05; mean +/- SEM, 31 +/- 11 versus 43 +/- 14 mm Hg, +39%), compared with baseline. After pre-treatment with L-NAME, the changes of PbtO2 after AVP were not significant (32 +/- 11 versus 28 +/- 10, -13%) when compared with the baseline. CONCLUSION: In this beating heart porcine model, local brain tissue oxygenation was improved after AVP alone, but not after inhibition of NO synthesis with L-NAME.

Animals↗

Arginine vasopressin reduces cerebral oxygenation and cerebral blood volume during intact circulation in swine---a near infrared spectroscopy study.

BACKGROUND AND OBJECTIVE: The aim of the present study was to investigate the impact of arginine vasopressin (AVP), a drug currently under investigation for use during cardiopulmonary resuscitation, on cerebral oxygenation and cerebral blood volume (CBV) in pigs with intact systemic circulation using near infrared spectroscopy. METHODS: Nine healthy pigs were anaesthetized and subjected to invasive haemodynamic monitoring as well as to non-invasive determination (with near infrared spectroscopy) of changes in the Tissue Oxygenation Index (TOI is the ratio of oxygenated to total tissue haemoglobin), Tissue Haemoglobin Index (THI, representing CBV) and cytochrome oxidase (deltaCytOx, representing the balance of intracellular oxygen supply). RESULTS: At both 3 and 5 min after AVP administration, TOI, THI and deltaCytOx were significantly (P < 0.001) reduced compared to baseline, while cerebral perfusion pressure increased significantly (P < 0.001). The effects of AVP on TOI and THI lasted longer than on deltaCytOx. There were no significant changes with respect to the intracranial pressure throughout the study period. CONCLUSIONS: No improvement of cerebral oxygenation was detected after AVP administration in swine with an intact systemic circulation. In contrast to recently published investigations, AVP provoked a sustained drop in indices of cerebral oxygenation and CBV.

Animals↗

Association between lower urinary tract symptoms and erectile dysfunction.

Our aim was to assess the association between lower urinary tract symptoms (LUTS) and erectile dysfunction by means of International Prostate Symptom Score (IPSS) and Sexual Health Inventory for Men (SHIM) questionnaire. A total of 69 eligible patients who were admitted to our outpatient clinic with lower urinary tract symptoms were included in the study. A self administered questionnaire of IPSS and SHIM were given to patients. Demographics and medical history data were recorded. Any risk factor that may be associated with erectile dysfunction, including coronary artery disease, diabetes, hypertension, and smoking status, was determined in each patient. Correlation tests were used to examine the relationship between lower urinary tract symptoms and erectile dysfunction by controlling the effects of age and comorbidities. Mean age was 58.6 +/- 13.1 31-86 years. Mean SHIM and IPSS total score was 14.3 +/- 7.5 and 11.5 +/- 8.1, respectively. Spearman correlation coefficient between IPSS and SHIM scores was found to be -0.41. There was a significant negative correlation with IPSS total scores of moderate degree when both age and presence of risk factor was controlled (r = -0.31; p = 0.009). Storage symptom scores showed significant correlation with SHIM scores (r = -0.33; p = 0.000). The association between SHIM score and each item of IPSS showed significant correlation for urgency, straining and nocturia when age controlled. The degree of bother by LUTS as determined by the IPSS quality of life question was also correlated with SHIM scores; however, this correlation was not significant when age or risk factor for ED was controlled. The presence of LUTS especially storage symptoms is strongly associated with erectile dysfunction independent of age and comorbidities.

Adult↗