PubMed Health⌕ Search

Biomedical subjects

E Cirillo

Publications and source records attributed to E Cirillo.

9 recordsLinked to original sources

Absorption of phenolic acids in humans after coffee consumption.

Despite extensive literature describing the biological effects of polyphenols, little is known about their absorption from diet, one major unresolved point consisting of the absorption of the bound forms of polyphenols. In this view, in the present work we studied the absorption in humans of phenolic acids from coffee, a common beverage particularly rich in bound phenolic acids, such as caffeic acid, ferulic acid, and p-coumaric acid. Coffee brew was analyzed for free and total (free + bound) phenolic acids. Chlorogenic acid (5'-caffeoylquinic acid), a bound form of caffeic acid, was present in coffee at high levels, while free phenolic acids were undetectable. After alkaline hydrolysis, which released bound phenolic acids, ferulic acid, p-coumaric acid, and high levels of caffeic acid were detected. Plasma samples were collected before and 1 and 2 h after coffee administration and analyzed for free and total phenolic acid content. Two different procedures were applied to release bound phenolic acids in plasma: beta-glucuronidase treatment and alkaline hydrolysis. Coffee administration resulted in increased total plasma caffeic acid concentration, with an absorption peak at 1 h. Caffeic acid was the only phenolic acid found in plasma samples after coffee administration, while chlorogenic acid was undetectable. Most of caffeic acid was present in plasma in bound form, mainly in the glucuronate/sulfate forms. Due to the absence of free caffeic acid in coffee, plasma caffeic acid is likely to be derived from hydrolysis of chlorogenic acid in the gastrointestinal tract.

Absorption↗

Nephrotic edema.

This article starts with a concise synopsis of the history of edema. The role of underfilling, overflow, antidiuretic hormone, and acquaporins is subsequently discussed. Emphasis is given to the use of diuretics in edematous patients. The role and risks of albumin infusion are illustrated. The new hypothesis of pulse reverse osmosis is discussed. The final section deals with the measurement of colloid osmotic pressure in the clinical setting.

Edema↗

Glomerular filtration rate in severely overweight normotensive humans.

The study examined whether indexing glomerular filtration rate (GFR) for body surface area is appropriate for people who are severely overweight. Twenty normotensive adult men who were severely overweight but without microalbuminuria were enrolled into this study. The control group consisted of 20 healthy subjects matched for age, sex, and height. GFR was determined by measuring insulin with the continuous-infusion method. The clearance of endogenous creatinine was also measured after two daily urine collections. Renal plasma flow (RPF) was measured by p-aminohippurate clearance using the continuous-infusion method. Lean body weight was measured by impedentiometry. Adjusting for body surface area (in 1.73 m(2)) caused a significant reduction in GFR (P < 0.0001) in overweight humans (84.1 +/- 2.32 versus 109.6 +/- 3.07 mL/min/1.73 m(2)). The difference disappeared when GFR/height criteria were adopted. No difference between obese and healthy controls occurred after adjusting for lean body weight. Data for creatinine clearance paralleled those with insulin clearance; a significant reduction (P < 0.001) occurred after indexing for basal surface area, which disappeared after correction for height, as well as for lean body weight.

Adipose Tissue↗

Measurement of glomerular filtration rate by the 99mTc-DTPA renogram is less precise than measured and predicted creatinine clearance.

The work was devised to compare measurements of glomerular filtration rate (GFR) by technetium-99m-diethylenetriaminepentacetic acid (99mTc-DTPA) renogram to those by creatinine clearance (measured and predicted by Cockroft and Gault) and by inulin clearance. A total number of 65 individuals were enrolled: 15 healthy controls and 50 patients with renal disease. Compared to inulin clearance used as the gold standard, 99mTc-DTPA overestimated at low and underestimated at high GFRs. 99mTc-DTPA measurements were less precise than creatinine clearance except for individuals with GFR >100 ml/min x 1.73 m2. Measured creatinine clearance had the highest correlation coefficient with inulin clearance, 99mTc-DTPA clearance the lowest. In correlation analyses, 81.5% of the interindividual variability for measured creatinine clearance could be explained by true differences in inulin clearance; this value dropped to 59.1 and 57.4% for predicted creatinine clearance and 99mTc-DTPA, respectively. In patients with GFR <25 ml/min x 1.73 m2, all 99mTc-DTPA measurements were out of the 95% confidence interval for the inulin measurement. It can be inferred that 99mTc-DTPA clearance from the renogram is less precise than measured and predicted creatinine clearance.

Adult↗

The renal hemodynamic response to an oral protein load is normal in IgA nephropathy.

The study was devised to explore the effects of an acute oral protein load on renal hemodynamic response in patients with IgA nephropathy (IgAN). The study was performed in 10 proteinuric IgAN patients (800 +/- 300 mg/day) and in 20 healthy controls (matched by sex, age, BMI, BSA, plasma creatinine, plasma urea, urinary urea and protein intake). Blood pressure and creatinine clearance were nearly identical in the two groups. GFR and RPF, measured as the clearance of inulin and of p-aminohippurate (PAH) were studied before and after a meat meal which provided 2 g of protein/kg BW. Following the protein load, renal reserve, percent renal reserve and postmeal cumulative changes of GFR were not significantly different in IgAN and controls. Filtration fraction (FF) at baseline was significantly higher (p < 0.01) in IgAN than in controls (25.5 +/- 1.41 vs. 19 +/- 2%). Postmeal hyperemia and hyperfiltration did not affect FF in either group. Filtration capacity in IgAN was lower (p<0.02) than in controls (117 +/- 5.6 vs. 137.9 +/- 7.0 ml/min x 1.73 m2), whereas the percent of filtration capacity utilized at rest was identical in controls and in IgAN. Creatinine clearance overestimated GFR in IgAN. The data indicate that renal hemodynamic response to proteins in IgAN is normal.

Adult↗

Renal reserve is normal in adults born with unilateral renal agenesis and is not related to hyperfiltration or renal failure.

This study was carried out to examine the renal hemodynamic response in adult patients with single kidneys born with unilateral renal agenesis. A group of 21 patients with unilateral renal agenesis were divided into three groups according to their glomerular filtration rate (GFR): 112 +/- 3 ml/min x 1.73 m2 in group A, 68 +/- 3.2 ml/min x 1.73 m2 in group B, and 40.7 +/- 3.3 ml/min x 1.73 m2 in group C. Mean arterial blood pressure was significantly higher in the patients of group C who were also proteinuric. The renal hemodynamic response to an oral protein load (2 g/kg of protein as beefsteak) was normal in all groups and unrelated to hyperfiltration or to renal failure and proteinuria. The study indicates that in patients with renal agenesis, the hemodynamic response to a protein challenge is similar to that of kidney donors, renal transplant recipients and uninephrectomized patients. The paper also demonstrates that the renal response to a protein challenge is inadequate to identify patients with renal agenesis who are at risk of developing renal disease. Finally, in renal agenesis with renal disease, creatinine clearance overestimated the GFR by an average of 32.7%.

Adaptation, Physiological↗

Diagnostic significance of the carcino-embryonal antigen in gynecologic neoplasia.

The carcino-embryonal antigen has been studied in 35 patients affected by malignant gynaecologic neoplasia (cervical, endometrial, vulval) and, for control, in 16 patients affected by small tumors of the genital area. In other 9 patients the day to day variability has been studied. Two determinants, before and after therapy were performed on every patient, and in many cases afterwards. The analysis of the results show the scarce reliability of the episodic C.E.A. determination of the plasma. The use of this parameter in the follow-up of malignant neoplasias gynaecologic can only be reserved in cases with high basic values and in which the therapy reduces the plasmic level significantly.

Carcinoembryonic Antigen↗

Renal reserve is normal in patients with dilative cardiomyopathy waiting for heart transplantation.

Renal reserve was explored by means of an oral protein load (2 g/kg body weight) under the form of cooked red meat in a group of 9 patients with end-stage heart failure (ESHF), class III of the New York Heart Association receiving loop diuretics and angiotensin-converting enzyme (ACE) inhibitors, and in a group of 18 healthy controls (HC) matched for age, gender, and height under an identical dietary regimen providing 40 cal/kg per day, 1 g/kg body weight of protein per day, Na 120 mmol/day, and K 50 mmol/day. Baseline glomerular filtration rate averaged 109.5+/-9.89 ml/min x 1.73 m2 in HC and 71.9+/-8.8 ml/min x 1.73 m2 in ESHF. Renal plasma flow averaged 540+/-27 ml/min x 1.73 m2 in HC and 235+/-47 ml/min x 1.73 m2 in ESHF. The filtration fraction was significantly higher in ESHF (p<0.01). Renal reserve averaged 26.03+/-3.28 ml/min x 1.73 m2 in HC and 27.2+/-7.12 ml/min x 1.73 m2 (not significant). Renal reserve averaged 123.9+/-2.9% in HC and 137.3+/-6.68% in ESHF (not significant). The filtration capacity was significantly higher in HC (p<0.001). The data point to a normalcy of renal reserve in ESHF which may depend on the chronic use of ACE inhibitors.

Adult↗

[Noise and office work].

BACKGROUND: The problem of the assessment of noise annoyance in the workplace has long been a topic of discussion. Several studies led to the definition of a set of descriptors suitable to describe noise in the workplace and its effects in terms of annoyance of the subjects exposed. OBJECTIVES: The aim of the study was to analyse the performance of different indices in terms of correlation with subjective sensation, taking into account those indices which combine both the intensity and the spectral quality of noise. METHOD: A noise survey was carried out in ten ofice buildings, covering 85 rooms. Objective measurements of environmental noise were made together with subjective evaluations collected through questionnaires. Subjective ratings were then averaged and correlated with objective parameters. Linear regression analyses were performed in order to assess the reliability of objective noise indices. RESULTS: The most important sources of noise were face-to-face and telephone conversations. All spectra had excess high frequency content. Regression analysis showed that under these conditions most noise indics provide a reliable prediction of subjective annoyance. However, the best performing parameter was the A-weighted equivalent sound pressure level followed by the Combined Noise Index which combines noise intensity and its spectral quality.

Acoustics↗