PubMed Health⌕ Search

Biomedical subjects

E D Pellizzari

Publications and source records attributed to E D Pellizzari.

69 records · Page 4Linked to original sources

An assessment of the data quality for NHEXAS--Part I: Exposure to metals and volatile organic chemicals in Region 5.

A National Human Exposure Assessment Survey (NHEXAS) was performed in U.S. Environmental Protection Agency (U.S. EPA) Region V, providing population-based exposure distribution data for metals and volatile organic chemicals (VOCs) in personal, indoor, and outdoor air, drinking water, beverages, food, dust, soil, blood, and urine. One of the principal objectives of NHEXAS was the testing of protocols for acquiring multimedia exposure measurements and developing databases for use in exposure models and assessments. Analysis of the data quality is one element in assessing the performance of the collection and analysis protocols used in NHEXAS. In addition, investigators must have data quality information available to guide their analyses of the study data. At the beginning of the program quality assurance (QA) goals were established for precision, accuracy, and method quantification limits. The assessment of data quality was complicated. First, quality control (QC) data were not available for all analytes and media sampled, because some of the QC data, e.g., precision of duplicate sample analysis, could be derived only if the analyte was present in the media sampled in at least four pairs of sample duplicates. Furthermore, several laboratories were responsible for the analysis of the collected samples. Each laboratory provided QC data according to their protocols and standard operating procedures (SOPs). Detection limits were established for each analyte in each sample type. The calculation of the method detection limits (MDLs) was different for each analytical method. The analytical methods for metals had adequate sensitivity for arsenic, lead, and cadmium in most media but not for chromium. The QA goals for arsenic and lead were met for all media except arsenic in dust and lead in air. The analytical methods for VOCs in air, water, and blood were sufficiently sensitive and met the QA goals, with very few exceptions. Accuracy was assessed as recovery from field controls. The results were excellent (> or = 98%) for metals in drinking water and acceptable (> or = 75%) for all VOCs except o-xylene in air. The recovery of VOCs from drinking water was lower, with all analytes except toluene (98%) in the 60-85% recovery range. The recovery of VOCs from drinking water also decreased when comparing holding times of < 8 and > 8 days. Assessment of the precision of sample collection and analysis was based on the percent relative standard deviation (% RSD) between the results for duplicate samples. In general, the number of duplicate samples (i.e., sample pairs) with measurable data were too few to assess the precision for cadmium and chromium in the various media. For arsenic and lead, the precision was excellent for indoor, and outdoor air (< 10% RSD) and, although not meeting QA goals, it was acceptable for arsenic in urine and lead in blood, but showed much higher variability in dust. There were no data available for metals in water and food to assess the precision of collection and analysis.

Adolescent↗

Particulate matter and manganese exposures in Indianapolis, Indiana.

The distribution of PM(2.5) and manganese (Mn) personal exposures was determined over a 4-month period in Indianapolis, IN, at a time when the gasoline additive, methylcyclopentadienyl manganese tricarbonyl (MMT), was not being used. The data collection period coincided with the data collection period in the Toronto, ON, study, where MMT had been used as a gasoline additive for over 20 years. The inferential or target population consisted of noninstitutionalized residents of the Indianapolis area during the monitoring period (from May 1996 through August 1996) who were at least 16 years old. The survey instruments used in this study (and also in Toronto) included a household screener form (HSF), a study questionnaire (SQ), and a time and activity questionnaire (TAQ). The SQ was administered to elicit information about the participant and his/her activities, occupation, and surroundings that might be relevant to his/her exposure to particles and Mn. In addition to the personal particulate matter (PM) and elemental 3-day monitoring, 240 participants completed a TAQ on a daily basis during the actual monitoring period. Also, a subset of participants had 3-day outdoor and indoor stationary monitoring at their home (approximately 58 observations), and sampling was conducted at a fixed site (approximately thirty-three 3-day observations). The quality of data was assessed and compared to the Toronto study in terms of linearity of measurement, instrument and method sensitivity, measurement biases, and measurement reproducibility. Twenty-six of the sample filters were subjected to two analyses to characterize the within-laboratory component of precision in terms of relative standard deviations (RSDs). The median RSD for Mn was 8.7%, as compared to 2.2% for Toronto. The quality assurance (QA) laboratory exhibited a clear positive bias relative to the primary laboratory for Al and Ca, but no systematic difference was evident for Mn. A high interlaboratory correlation (>0.99) was also attained for Mn. Mean field blank results for PM and Mn were 0.87 microg/m(3) and 0.71 ng/m(3), respectively, which were comparable to the Toronto study. The median RSDs for colocated fixed site and residential samples ranged from 2.2% to 9.0% for PM and from 8.8% to 15.3% for Mn, which were close to those observed in Toronto. For the PM(10), the 90th percentile indoors was 124 microg/m(3) compared with 54 microg/m(3) outdoors. This pattern was even more pronounced for the PM(2.5) data (90th percentiles of 92 microg/m(3) indoors vs 30 microg/m(3) outdoors). Personal PM(2.5) was somewhat higher than the indoor levels, but the percentiles seemed to follow the more highly skewed pattern of the indoor distribution. This difference was largely due to the presence of some smokers in the sample; e.g., exclusion of smokers led to a personal exposure distribution that was more similar to the outdoor distribution. The estimated 90th percentile for the nonsmokers' personal exposures to PM was 43 microg/m(3) compared with 84 microg/m(3) for the overall population. In general, the Indianapolis PM levels of a given type and cut size were somewhat higher than the levels observed in Toronto, e.g., the median and 90th percentile for the personal PM(2.5) exposures were 23 and 85 microg/m(3), respectively, in Indianapolis, while in Toronto, the corresponding percentiles were 19 and 63 microg/m(3). The cities' distributions of the proportion of the PM(10) mass in the 2.5-microm fraction appeared similar for the residential outdoor data (medians of 0.67 and 0.65 for Indianapolis and Toronto, respectively, and 90th percentiles of 0.83 for both cities). For the indoor data, Indianapolis tended to have a larger portion of the mass in the fine fraction (median of 0.80 compared to 0.70 for Toronto). Unlike the PM, the Indianapolis indoor Mn concentration levels were substantially lower than the outdoor levels for both PM sizes, and the median personal levels for Mn in PM(2.5) appeared to fall between the median indoor and outdoor levels. The personal Mn exposure distributions exhibited more skewness than the indoor or outdoor distributions (e.g., the means for the personal, indoor, and outdoor distributions were 7.5, 2.6, and 3.5 ng/m(3), respectively, while the medians were 2.8, 2.2, and 3.2 ng/m(3), respectively). At least a substantial portion of the high end of the personal exposure distribution appeared to be associated with occupational exposures to Mn. In general, the Mn levels in both cut sizes in Indianapolis were approximately 5 ng/m(3) smaller than those in Toronto (e.g., the estimated median and mean levels for personal Mn exposures in PM(2.5) were 2.8 and 7.5 ng/m(3), respectively, in Indianapolis, but were 8.0 and 13.1 ng/m(3) in Toronto). For the nonoccupational subgroups with no exposure to smoking and no subway riders in the two cities, the medians (2.6 ng/m(3) in Indianapolis and 7.8 ng/m(3) in Toronto) were similar to those for the overall populations, but the means were substantially smaller (3.1 ng/m(3) in Indianapolis and 9.2 ng/m(3) in Toronto). The median proportion of Mn in the fine fraction (relative to the PM(10) Mn) for Indianapolis was 0.39 for outdoors and 0.55 for indoors; these ratios were somewhat smaller than the corresponding Toronto medians (0.52 and 0.73). The study found high correlations for particulates and Mn between personal exposures and indoor concentrations, and between outdoor and fixed site concentrations, and low correlations of personal and indoor levels with outdoor and fixed site levels. The pattern was similar to that observed for Toronto, but slightly more pronounced. The PM(10) Mn concentrations (log scale) generally exhibited stronger associations among these various measures than the PM(2.5) Mn concentrations. Comparisons of the particulate distributions between PTEAM (Riverside, CA) and the Indianapolis and Toronto studies were also made.

Adolescent↗

Quantitative analysis of children's microactivity patterns: The Minnesota Children's Pesticide Exposure Study.

The National Human Exposure Assessment Survey (NHEXAS)/Minnesota Children's Pesticide Exposure Study (MNCPES) was a population-based study designed to characterize children's exposure to residential pesticides and to evaluate the contribution of residential and children's activities to children's exposure. Families of 168 children were surveyed for residential use of pesticides and children's activities. From these homes, families of 102 children between the ages of 3 and 13 years participated in a week-long intensive exposure study. Of the 102 children, 19 children were videotaped for four consecutive hours in their normal daily activities. The survey responses indicated that the youngest children were more likely to exhibit behaviors that would foster exposure to environmental contaminants. Comparison of questionnaire responses indicated that the videotaped subsample was representative of the exposure study population. The microactivities of the videotaped children that might contribute to their exposure via ingestion or dermal routes were quantified. Hand-to-mouth and object-to-mouth activities were observed most frequently among the youngest children. The youngest children were also most likely to be barefoot both indoors and outside. Gender differences were found in mouthing behavior and the proportion of observed time spent outdoors.

Activities of Daily Living↗

National Human Exposure Assessment Survey: analysis of exposure pathways and routes for arsenic and lead in EPA Region 5.

The National Human Exposure Assessment Survey (NHEXAS) Phase I field study conducted in EPA Region 5 (Great Lakes Area) provides extensive exposure data on a representative sample of approximately 250 residents of the region. Associated environmental media and biomarker (blood, urine) concentration data were also obtained for the study participants to aid in understanding of the relationships of exposures to both contaminant pathways and doses. Besides fulfilling the primary NHEXAS objectives, the NHEXAS data provided an opportunity to explore secondary usages, such as examining pathway to route of exposure relationships. A generic type of structural equation model was used to define the anticipated relationships among the various data types for both arsenic (As) and lead (Pb). Since, by design, only a few participants provided data for all sample types, implementing this model required that some media concentrations (outdoor air and soil) be imputed for subjects with missing information by using measurements collected in the same geographic area and time period. The model, and associated pairwise correlations, generally revealed significant but weak associations among the concentrations, exposures, and doses; the strongest associations occurred for the various air measurements (indoor versus outdoor and personal). The generally weak associations were thought to be partly due to the absence of complete coverage of nonresidential environmental media and to nonsynchronization of relevant measurement times and integration periods of collection across the various sample types. In general, relationships between the NHEXAS questionnaire data and the various concentration, exposure, and body-burden measures were also weak. The model results and the modeling exercise suggest several ways for optimizing the design of future exposure assessment studies that are aimed at supporting structural modeling activities.

Air Pollution↗

A device for sampling of human alveolar breath for the measurement of expired volatile organic compounds.

This report describes the development of a portable spirometer capable of collecting primarily alveolar breath into 1.8-L canisters for subsequent gas chromatographic/mass spectrometric (GC/MS) analysis. Based on CO2 measurements, greater than 97% of the breath collected is alveolar in origin. Sample collection takes place in approximately two minutes. Clean air for inhalation is provided by two organic vapor respirator cartridges. Studies of the breakthrough volume of test compounds at both the 5- and 50-micrograms/m3 levels indicate that each cartridge filter can be used to sample over 300 L of air and that this volume is not altered by intermittent use and storage of the filter for up to five days. In experiments designed to mimic human breathing, recoveries of test compounds through the device at the 5-mu/m3 level ranged from 87 to 112%. Essentially no volatile organic compound (VOC) memory (i.e., adsorption carryover by the device) was measured at the 50-micrograms/m3 level. The data suggest that the device can be used successfully for organic compounds with volatilities greater than that of p-dichlorobenzene.

Air Pollutants↗

A canister-based method for collection and GC/MS analysis of volatile organic compounds in human breath.

A method previously used for collection and analysis of volatile organic compounds (VOCs) in human whole breath was modified to encompass compounds with higher vapor pressures. A VOC spirometer was designed for field studies of environmentally exposed populations with breath concentrations in the microgram/m3 (ppb) range. The VOC spirometer was configured for sample collection and GC/MS analysis of breath samples using stainless steel canisters. Recoveries of 17 analytes in synthetic breath through the spirometer at 4 and 21 degrees C were generally above 80% except for n-dodecane which demonstrated poor recoveries at the lower temperature. The maximum sample volume available for analysis during recovery studies with natural breath was 100 mL because of copious quantities of CO2 present. Decay curves showing the breath elimination of 1,1,1-trichloroethane and benzene from a man after exposure to consumer products demonstrates the utility of the method.

Breath Tests↗

Elimination kinetics of volatile organics in humans using breath measurements.

During the past decade significant strides have been made toward understanding the sources and factors which lead to volatile organic chemical (VOC) exposure in the general population. Less is known, however, about the impact of low-level environmental exposure on human health. Investigations are underway in a number of laboratories in an effort to determine the uptake, distribution, metabolism, and elimination kinetics for VOCs in humans. We examined the elimination kinetics for the third phase for ten VOCs--1,1,-trichloroethane, trichloroethylene, tetrachloroethylene, benzene, toluene, m,p-xylenes, o-xylene, ethylbenzene, p-dichlorobenzene, and limonene--in human subjects. Subjects were exposed to a variety of common consumer products and breath samples were collected post-exposure while the subjects spent up to 10 hr in a clean air environment. VOCs from breath samples were collected into canisters or onto Tenax GC cartridges and analyzed by gas chromatography-mass spectrometry. Exponential modeling of the decay data was performed to obtain kinetic parameters. The half-lives for trichloroethylene and 1,1,1-trichloroethane were approximately 5 to 8 hr for the four subjects. In general, the magnitude and range of variability was larger for toluene, limonene, and p-dichlorobenzene than for the other VOCs; the elimination rate spanning a few hours to a day or two. Thus, VOCs exhibit relatively short residence times in the body relative to other halo-carbons, such as polychlorinated biphenyls and dioxins.

Adult↗

The identification of polar organic compounds found in consumer products and their toxicological properties.

Exposure to volatile organic compounds (VOCs) in the indoor environment has received substantial research attention in the past several years, with the goal of better understanding the impact of such exposures on human health and well-being. Many VOCs can arise from consumer products used within the indoor environment. The VOCs emitted from five representative consumer products were collected onto Tenax-GC and subjected to thermal desorption and analysis by gas chromatography, in combination with low-resolution mass spectrometry (MS), high-resolution MS, and matrix-isolation Fourier transform infrared spectroscopy for structural characterization. An emphasis was placed on the polar organic compounds often used to provide fragrance in these products. The structures of a number of these compounds were confirmed, and an electronic literature search was carried out on them to determine any known toxic properties. The search revealed that many of the VOCs possess toxic properties when studied at acute, relatively high-level exposures. In addition, toxic effects were reported for a few of the chemicals, such as benzaldehyde, alpha-terpineol, benzyl acetate, and ethanol, at relatively low dose levels of 9-14 mg/kg. In general, the data were unclear as to the effect of chronic, low-level exposures. The widespread use of such chemicals suggests that the health effects of chronic exposures need to be determined. Validated analytical methods for the quantitative characterization of polar organic compounds at low concentrations will be required to make such work possible.

Air Pollution, Indoor↗

Identification of 1,3-butadiene, benzene, and other volatile organics from wok oil emissions.

As part of a program to determine the underlying factors responsible for genotoxicity and perhaps lung cancer risk in Chinese women, we qualitatively identified the volatile components emitted during the heating of cooking oils to 265 degrees C. 1,3-Butadiene, benzene, and a series of aldehydes, olefins, and saturated hydrocarbons were elucidated in vapors from Chinese rapeseed oil. On a relative basis, the intensity of 1,3-butadiene vapors from this were 15.7-, 6.3-, and 1.4-fold greater than in the vapors from peanut, soybean, and Canola oils, respectively. Thus, the Chinese rapeseed oil yielded a higher emission rate of 1,3-butadiene than the other three oils investigated. The benzene formation rate followed a similar trend, i.e., its intensity in Chinese rapeseed oil was 14-, 6.6-, and 1.7-fold greater than in vapors from peanut, soybean, and Canola oils, respectively.

Arachis↗

Temporal variability of benzene exposures for residents in several New Jersey homes with attached garages or tobacco smoke.

The U.S. Environmental Protection Agency's (EPA) previous TEAM studies of personal exposure to VOCs for 700 residents in several U.S. cities found that indoor air concentrations were often higher than outdoor levels. Several potential sources of benzene exposure were identified, including environmental tobacco smoke and materials or activities associated with attached garages. Indoor, personal, and outdoor monitoring was conducted at eleven New Jersey homes over multiple 12-hr monitoring periods. One study objective was to assess the impact of attached garages on human exposure to benzene and the variability of benzene exposure across time. Benzene was also measured in several homes inhabited by smokers and in homes without known combustion sources for comparative purposes. At homes with a garage or environmental tobacco smoke, mean indoor and personal benzene concentrations were two to five times higher than outdoor levels at all but one home. Mean personal exposures ranged from 8 to 31 micrograms/m3. Indoor/outdoor ratios were calculated and ranged from 0.8 to 11. Benzene levels in the four garages ranged from 3 to 196 micrograms/m3 and usually were higher than either indoor living areas or personal levels. Multi-zone air exchange rates were measured, and benzene source strengths in each zone were estimated. Garage source strength estimates for benzene ranged from 310 to 52,000 micrograms/h. The mass transfer of benzene from sources in the garage to home living areas was also large in three of the homes, ranging from 730 to 26,000 micrograms/h. Materials or activities in the garage were a source of benzene exposure for the residents in these three homes. Large temporal variations (factors of 2 to 30) were observed in indoor and personal benzene concentrations, indoor/outdoor ratios, and source strengths over the six or ten monitoring periods at each home. Changes in outdoor air benzene levels were an underlying factor in changing exposure levels, with indoor sources further elevating indoor air levels and personal exposures.

Air Pollution, Indoor↗

Particle Total Exposure Assessment Methodology (PTEAM) study: distributions of aerosol and elemental concentrations in personal, indoor, and outdoor air samples in a southern California community.

Particle concentrations were measured for a probability-based sample of 178 nonsmoking individuals aged 10 or older residing in Riverside, California, in the fall of 1990. Two 12-hr personal-exposure PM10 samples were obtained for each participant, along with fixed-location PM10 and PM2.5 indoor and outdoor air samples at their residences. The particle samples were also analyzed via X-ray fluorescence (XRF) to determine elemental concentrations for selected elements, including some toxic metals, crustal elements, and combustion- and industrial-source related elements. About 25% of the target population was estimated to have 24-hr personal exposures to PM10 that exceeded the national ambient air concentration standard of 150 micrograms/m3. The daytime personal exposure levels (median of 130 micrograms/m3) tended to exceed both indoor and outdoor levels by about 50%; nighttime personal exposure levels were lower and were only slightly higher than nighttime indoor levels. Several possible reasons for the elevated daytime personal PM10 levels (relative to indoor levels) are considered. Certain activities such as house cleaning and smoking were found to be associated with elevated personal exposure levels.

Aerosols↗

Particle Total Exposure Assessment Methodology (PTEAM) 1990 study: method performance and data quality for personal, indoor, and outdoor monitoring.

The Particle Total Exposure Assessment Methodology (PTEAM) study provided the opportunity to test methodologies for measuring personal and microenvironmental PM10 and PM2.5 concentrations in a full-scale probability-based sample of 178 persons and homes in Riverside, California during the fall of 1990. The purpose of the study was to estimate frequency distributions of exposure to PM10, PM2.5, and selected elements in an urban population. Quality control samples and analyses were used to evaluate method performance. These included collocated sample collection, field and lab blank filters, sampler and balance field audits, and intra- and interlaboratory replicate elemental analyses. A portion of the study was also designed to include side-by-side operation of the personal and microenvironmental samplers with reference method (high-volume and dichotomous) samplers to provide an evaluation of method comparability. Over 95% of the approximately 2,900 scheduled samples were collected and analyzed, with very few losses due to equipment failure. The method limit of detection for the personal and microenvironmental monitor PM10 sampling was 8 micrograms/m3. Mean relative standard deviations (RSDs) of 2% to 8% were obtained for collocated personal and microenvironmental samples. Sampler flow rates were within the +/- 10% accuracy criterion during two field audits. Balances operated in a specially designed mobile laboratory were within specified tolerances for precision (+/- 4 micrograms) and accuracy (+/- 50 micrograms). Elemental analysis accuracy was measured with standard reference materials with biases ranging from 2% to 7%. Measurement precision for most elements ranged from 2.5% to 25% mean RSD. Personal and microenvironmental samplers gave median PM10 concentrations that were approximately 9% higher than the dichotomous sampler and 16% higher than the high-volume sampler across 96 monitoring periods at a fixed outdoor location.

Air Pollution↗

Testing duplicate diet sample collection methods for measuring personal dietary exposures to chemical contaminants.

Dietary ingestion may be a significant pathway of human exposure to many potentially toxic chemicals. The U.S. Environmental Protection Agency-National Human Exposure Laboratory has made the development of methods for measuring personal dietary exposures a high priority for its dietary exposure research program. Of particular interest was the testing of methods that could be applied in the general population as one component of multipathway exposure measurement studies. This paper describes a controlled pilot study that was conducted to evaluate procedures for collecting and processing duplicate diet samples. Nine adult and three child participants volunteered to provide dietary information for 28 days, and duplicate portions of all foods consumed daily for seven consecutive days. Sample collection procedures were evaluated for participant collection and segregation of solid and liquid foods, and for identification and separation of high-fat and low-fat foods. Methods for compositing and homogenizing mixed diet samples were tested. Food records and questionnaires were tested to document the collected food and to evaluate procedures for assessing dietary changes and collection bias. Participant time and monetary needs were evaluated along with the approach for training and providing support to study participants. Participants were able to collect 96% of the meals they consumed, even with 33% of the meals consumed away from home. Food consumed in social settings was the most difficult to collect, and participants were unable or unwilling to collect foods in some social settings. Noncollection of meals and food items increased after the third day of collection. Mixed diet samples were successfully homogenized, with 1%-11% mean relative standard deviations for moisture, fat, protein, and ash analysis in replicate sample aliquots. The laboratory-measured caloric content of collected foods was an average of 12% (range: -24% to 36%) lower than estimates of energy intake using a food diary and 16% lower than estimated energy expenditure values.

Adolescent↗

Uptake and decay of volatile organic compounds at environmental concentrations: application of a four-compartment model to a chamber study of five human subjects.

Five subjects were exposed to nine volatile organic compounds (VOCs) at concentrations that can be encountered in everyday life. Breath samples were collected during a 10-h uptake phase and a 24-h decay phase. It was possible to determine four distinct slopes in the decay curve for each chemical. The distribution in the body and residence times in different tissues were calculated using a linear four-compartment mass-balance model. The model was used to predict breath concentrations for two subjects in a second chamber experiment including the same nine VOCs, representing three chemical classes (aromatic, aliphatic, and chlorinated compounds). Predicted values were generally within 25% of those observed, suggesting that the model parameters calculated here could be useful in estimating exposure and body burden to other VOCs in these three classes. Median residence times for the nine VOCs ranged from 3-12 min for compartment 1 (metabolizing); 0.3-2 h for compartment 2; 2-5 h for compartment 3; and 1-4 d for compartment 4. The fraction of the parent compound exhaled at equilibrium was estimated to range from 0.06-0.16 for four aromatic compounds and decane; 0.22-0.23 for trichloroethylene and dichloromethane; 0.35 for hexane; and 0.88 for 1,1,1-trichloroethane. Limited blood measurements were obtained for six of the nine VOCs in two subjects simultaneously with the breath samples over four-hour decay periods. Blood/breath ratios agreed well between the two subjects, but were higher than human blood/air partition coefficients reported in subjects exposed to high concentrations. This observation is consistent with results from other studies at relatively low concentrations.

Adult↗