PubMed Health⌕ Search

Biomedical subjects

E E Fibuch

Publications and source records attributed to E E Fibuch.

15 recordsLinked to original sources

Postoperative analgesia using a low-dose, oral-transdermal clonidine combination: lack of clinical efficacy.

STUDY OBJECTIVE: To determine if a lower than previously reported oral-transdermal clonidine regimen could reduce postoperative morphine requirements without producing systemic side effects. DESIGN: Double-blind, randomized, placebo-controlled study. SETTING: University-affiliated hospital. PATIENTS: 29 healthy, ASA physical status I and II females undergoing elective abdominal hysterectomy. INTERVENTIONS: Patients received preoperative oral clonidine 4 to 5 mu/kg and a 7 cm2 transdermal clonidine patch (0.2 mg/24 hours) or a placebo tablet and patch. MEASUREMENTS AND MAIN RESULTS: Postoperative patient-controlled analgesia pumps provided morphine during the 48-hour study period. Morphine use, hemodynamic changes, and nonhemodynamic side effects were recorded. Additionally, visual analog pain scales (VAPS) and plasma concentrations of morphine and clonidine were measured. We found that low-dose clonidine had no potentiating effect on morphine analgesia. Postoperative morphine use, VAPS, and morphine plasma levels were similar between the control and clonidine-treated groups. Nevertheless, patients in the clonidine group experienced a significantly greater incidence of intraoperative and postoperative hypotension and bradycardia than did the control group. No differences were noted in the incidence of nonhemodynamic side effects. CONCLUSIONS: The low-dose oral-transdermal clonidine regimen evaluated failed to reduce postoperative morphine requirements, although patients who received clonidine were still at risk for developing hypotension.

Administration, Cutaneous↗

Effect of oxygenator type and bypass flow pattern on the P(a-ET)CO2 gradient.

Changes in pre-bypass and post-bypass P(a-ET)CO2 gradients were evaluated regarding the type of bypass flow (pulsatile or nonpulsatile) and oxygenator (membrane or bubble). Duration of bypass and hemodynamic changes were analyzed also to determine their possible influence on PaCO2, PETCO2, and P(a-ET)CO2. A total of 36 adult patients undergoing cardiopulmonary bypass were anesthetized using a sufentanil-pancuronium-oxygen technique. Patients were divided into three groups based on the type of oxygenator and pump flow: group 1 (control group) consisted of a bubble oxygenator with nonpulsatile flow (BN), group 2 consisted of a bubble oxygenator with pulsatile flow (BP), and group 3 consisted of a membrane oxygenator with nonpulsatile flow (MN). Cardiac parameters (MAP, CI, SVR, and PVR) PaCO2, PETCO2, and P(a-ET)CO2 were determined pre-bypass and post-bypass following steady-state conditions. For the entire group there was a trend for the P(a-ET)CO2 gradient to increase in the post-bypass period (pre-bypass = 3.5 +/- 0.5 mm Hg, post-bypass = 4.3 +/- 0.5 mm Hg.). However, this increase was not statistically significant. Pulsatile flow (group 2) demonstrated a significant correlation with the change in P(a-ET)CO2 gradients from the pre-bypass to the post-bypass period (r = 0.85) when compared with the other two groups (group 1: r = -0.09 and group 3: r = 0.37). Thus, the P(a-ET)CO2 gradient tended to remain constant from the pre-bypass to the post-bypass period in group 2, whereas it increased in groups 1 and 3. Changes in MAP, CI, SVR, and PVR and the duration of CPB did not influence the P(a-ET)CO2 gradient.

Adult↗

Epidural morphine with butorphanol for postoperative analgesia after cesarean delivery.

Epidural morphine has been used more and more to provide long-lasting postoperative analgesia after cesarean delivery. However, the incidence of pruritus (20%-93%) and nausea (17%-60%) detract from the usefulness of epidural morphine. The purpose of this study was to evaluate, in 30 patients having epidural anesthesia for cesarean delivery, the analgesic efficacy and side effects when a combination of epidural morphine, a mu-receptor agonist, and butorphanol, a mu-receptor antagonist and kappa-receptor agonist, was administered. After clamping of the umbilical cord, patients received 4 mg epidural morphine with 3 mL of normal saline (group 1), 4 mg epidural morphine with 1 mg butorphanol and 2 mL of normal saline (group 2), or 4 mg epidural morphine with 3 mg butorphanol (group 3). Patients were monitored for 24 h after administration of the study medications. There were no significant differences between the groups in visual analogue pain scores, time to first analgesic request, respiratory rate, or Trieger dot test performance in the 24 h immediately after these epidural injections. There were three patients in group 1 and one patient in group 2 who experienced oxygen saturations less than 90%. (No patients in group 3 developed an oxygen saturation less than 92%.) The patients in group 3 did not require treatment for pruritus or nausea, a response significantly different (P less than 0.001 and P less than 0.05, respectively) from group 1 or group 2.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

A clinical evaluation of the accuracy of the Nellcor N-100 and Ohmeda 3700 pulse oximeters.

Two pulse oximeters, the Nellcor N-100 and the Ohmeda 3700, were compared with arterial blood values and with each other in a clinical evaluation of performance. Three hundred twenty-nine simultaneously sampled blood/oximeter data pairs from use of both makes of pulse oximeters on each of 152 test subjects were included in the comparison analysis for each oximeter. Among the patients, disease type and severity and hospital location varied widely. Basic descriptive statistics and linear regression analysis were employed to facilitate comparison. Both oximeters displayed a statistically significant but clinically insignificant bias when compared with arterial blood oxyhemoglobin: -0.31 (P = 0.023) and 0.59 (P = 0.001) for the Ohmeda 3700 pulse oximeter and the Nellcor N-100 pulse oximeter, respectively. Relative to arterial blood oxyhemoglobin, the 95% tolerance intervals were +4.84 to -5.45 (10.3) for the Ohmeda 3700 and +6.94 to -5.76 (12.7) for the Nellcor N-100. Regressed against [oxyhemoglobin + carboxyhemoglobin + methemoglobin] as x, the Nellcor N-100 read y = 0.85(x) + 12.5, r = 0.83, P less than 0.0001, and the Ohmeda 3700 read y = 1.02(x) - 5.3, r = 0.86, P less than 0.0001.

Female↗

Transorally obtained oxygen tension as an indicator of arterial oxygen tension.

Transcutaneous oxygen electrodes have been used with success in neonates as indicators of arterial oxygenation, but with less success in adults because of differences in skin thickness and vascularity. In this study, a prototype transoral oxygen electrode was evaluated to determine if a heated mucous membrane would yield arterialized values of oxygen tension in adults. Using a miniaturized Clark electrode, we measured transoral oxygen tension (PtoO2) in 29 subjects at steady-state conditions. Simultaneously a sample was anaerobically obtained from a radial artery for measurement of arterial oxygen tension (PaO2). Data were analyzed using linear regression analysis, Student's t test, and analysis of variance. There was no statistically significant difference between nonwhite and white subjects or male and female subjects. There was a highly significant difference (P less than 0.001) between the pooled, matched values for PtoO2 versus PaO2, and the regression between the PtoO2 and the PaO2 was linear (slope 0.92, y-intercept -8.37, r = 0.62, P less than 0.003). The calculated ratio of PtoO2 to PaO2 was 0.83 +/- 0.03 (standard error). We concluded that the PtoO2 was linearly related to the PaO2, although its accuracy in reflecting PaO2 was low. This finding correlates with previously published data that suggested that the PtoO2 reflects tissue oxygen tension rather than arterialized oxygen tension. Gender and race appeared not to affect the function of the electrode in our study.

Adult↗

Autonomic hyperreflexia in a pregnant paraplegic patient. Case report.

BACKGROUND AND OBJECTIVES: Pregnant patients with spinal cord injuries are predisposed to autonomic hyperreflexia, which if unrecognized or untreated can lead to death. Hypertension occurring in laboring patients at risk for autonomic hyperreflexia must be managed aggressively. METHODS: Epidural anesthesia can safely control autonomic hyperreflexia during labor and delivery, but because spinal cord impaired patients lack sensory and motor function below the level of injury, it is difficult to determine the dermatomal spread of epidural anesthesia by the usual methods. This difficulty is highlighted by the following case, reporting an epidural that failed during labor, with the subsequent development of autonomic hyperreflexia. RESULTS: Previously, autonomic hyperreflexia occurring in pregnant patients (undergoing surgical procedures) was treated with intravenous antihypertensive agents. During labor, however, titrating these agents to coincide with uterine contractions is difficult. In this case, epidural anesthesia was repeated and the autonomic hyperreflexia resolved. CONCLUSIONS: Autonomic hyperreflexia can develop in unanesthetized laboring paraplegic patients (failed epidural) but it can be successfully managed with adequate epidural anesthesia.

Adult↗

Uncommon applications for continuous spinal anesthesia.

The role that uncommon agents of antinociception, placed intrathecally, play in the control of nociceptive signal transmission in the spinal cord is described. Three specific agents are discussed in detail: baclofen, a gamma aminobutyric acid mimetic agent; clonidine, an alpha-2 agonist; and somatostatin, a neuroinhibitory peptide. In addition, the efficacy of using an implanted pump-catheter system for the long-term infusion of baclofen and octreotide, a somatostatin-like analog, is reviewed.

Anesthesia, Spinal↗