Publications and source records attributed to E E Klein.

At least 19 recordsLinked to original sources

A reduction in the AAPM TG-36 reported peripheral dose distributions with tertiary multileaf collimation. American Association of Physicists in Medicine Task Group 36.

PURPOSE: The American Association of Physicists in Medicine Task Group 36 (AAPM TG-36) data can be used to estimate peripheral dose (PD) distributions outside the primary radiation field. However, the report data apply to linear accelerators not equipped with tertiary multileaf collimators (MLCs). Peripheral dose distributions consist of internal scatter, collimation scatter, transmission through collimation, head leakage, and room scatter. Tertiary MLCs may significantly reduce the PD due to a reduction in collimation scatter, transmission through collimation, and head leakage. Measurements were performed on a multimodality linear accelerator, equipped with a tertiary MLC, to determine PD distributions as a function of energy, field size, distance from the primary radiation field edge, MLC position, and collimator orientation. METHODS AND MATERIALS: Measurements were made using an ionization chamber embedded in a 20 x 40 x 120-cm3 water-equivalent plastic phantom with the secondary collimator and MLC settings of 10 x 10, 15 x 15, 20 x 20, 25 x 25 cm2, and with the MLC fully retracted. Data were taken along the longitudinal axis of the machine for 6 and 18 MV photons. Peripheral dose distributions were evaluated with the collimator set to 180 and 90 degrees. Rotation of the collimator allowed measurements parallel and orthogonal to the direction of motion of the MLC. RESULTS: For both photon energies, peripheral doses measured on a MLC machine were lower than the TG-36 data. When the collimator is rotated by 90 degrees, placing the lower jaws and the MLC leaves along the plane of interest, PD was reduced by as much as a factor of three compared with PDs measured with the MLC fully retracted and the collimator rotated to 180 degrees. PDs measured with the MLC fully retracted and collimator rotated to 180 degrees were comparable to the TG-36 data. Measured PDs were lower when the MLC was used to shape the field than when the MLC was fully retracted. CONCLUSION: A strategic orientation of the collimator with a tertiary MLC can reduce PD distributions by more than a factor of two. This decrease significantly lessens or eliminates the need for external lead shielding to reduce the critical organ dose. This method can be used even when Lipowitz metal blocking (such as for mantle fields) is used, with the MLC leaves oriented along the longitudinal plane.

Particle Accelerators

Technology assessment of multileaf collimation: a North American users survey.

PURPOSE: The American Association of Physicists in Medicine (AAPM) initiated an Assessment of Technology Subcommittee (ATS) to help the radiotherapy community evaluate emerging technologies. The ATS decided to first address multileaf collimation (MLC) by means of a North American users survey. The survey attempted to address issues such as MLC utility, efficacy, cost-effectiveness, and customer satisfaction. METHODS AND MATERIALS: The survey was designed with 38 questions, with cross-tabulation set up to decipher a particular clinic's perception of MLC. The surveys were coded according to MLC types, which were narrowed to four: Elekta, Siemens, Varian 52-leaf, and Varian 80-leaf. A 40% return rate was desired. RESULTS: A 44% (108 of 250) return was achieved. On an MLC machine, 76.5% of photon patients are being treated with MLC. The main reasons for not using MLC were stair stepping, field size limitation, and physician objection. The most common sites in which MLC is being used are lung, pelvis, and prostate. The least used sites are head & neck and mantle fields. Of the facilities, 31% claimed an increase in number of patients being treated since MLC was installed, and 44% claimed an increase in the number of fields. Though the staffing for block cutting has decreased, therapist staffing has not. However, 91% of the facilities claimed a decreased workload for the therapists, despite the increase in daily treated patients and fields. Of the facilities that justified MLC purchase for more daily patients, 63% are actually treating more patients. Only 26% of the facilities that justified an MLC purchase for intensity-modulated radiotherapy (IMRT) are currently using it for that purpose. The satisfaction rating (1 = low to 5 = high) for department groups averaged 4.0. Therapists ranked MLC as 4.6. CONCLUSIONS: Our survey shows that most users have successfully introduced MLC into the clinic as a block replacement. Most have found MLC to be cost-effective and efficient. The use of MLC for IMRT has progressed slower, but users anticipate escalated use.

Consumer Behavior

A change in treatment process with a modern record and verify system.

PURPOSE: With the introduction of new treatment devices, such as a multileaf collimator (MLC) and dynamic wedge (DW), therapists have an increased responsibility to ensure correct treatment. Simultaneously, three-dimensional treatment planning (3DTP) has led to an increased number of portals and table movements. To counteract this challenge and maintain efficiency, a comprehensive record and verify (R&V) system is mandatory. We evaluated a commercial system (Varis) for reliability, ease of use, efficiency, and integration with our planning systems. METHODS AND MATERIALS: Some key elements of the Varis system are: integration of MLC and DW; auto setup for MLC, jaw, collimator, gantry, and limited table parameters; direct download of simulation beam data; and a regimented field scheduling system that prescribes all beam data for particular fractions. Evaluation of the system was driven by treatment time analysis, error rates, and an increased workload. These issues were governed by how we disseminated duties and how the system accommodated or changed our processes. RESULTS: Most data entry is performed by our dosimetry staff. Data can be downloaded from the simulator, but more patients now move from CT simulation and/or 3DTP to the treatment machine. Varis does not link to these systems. The physics staff confirms all entries to correct data entry errors. The workload for dosimetrists increased by an average of 8 minutes/patient entry; physics time increased by 7 minutes/patient entry; the weekly electronic chart check takes approximately 3 minutes/patient. Therapists who used Varis efficiently showed a slight decrease in treatment times, attributed to MLC integration and auto-setup. Some therapists experienced a decrease in efficiency, because of unfamiliarity and excess intervention. On a positive note, notable events have decreased by a factor of 10 since full initiation. Unfortunately, the remaining errors are often the result of a therapist relying on incorrect electronic information. CONCLUSION: The Varis R&V system has had an impact on our clinic's process and efficiency. Checking of all beam data and related field scheduling have helped reduce errors and misconceptions. We feel a dual-energy machine can be operated with two experienced therapists and an up-to-date R&V system more accurately and efficiently than with three therapists working without an integrated R&V. We anticipate future Varis releases will further promote efficiency and accuracy.

Computer Communication Networks

Study of lung density corrections in a clinical trial (RTOG 88-08). Radiation Therapy Oncology Group.

PURPOSE: To investigate the effect of lung density corrections on the dose delivered to lung cancer radiotherapy patients in a multi-institutional clinical trial, and to determine whether commonly available density-correction algorithms are sufficient to improve the accuracy and precision of dose calculation in the clinical trials setting. METHODS AND MATERIALS: A benchmark problem was designed (and a corresponding phantom fabricated) to test density-correction algorithms under standard conditions for photon beams ranging from 60Co to 24 MV. Point doses and isodose distributions submitted for a Phase III trial in regionally advanced, unresectable non-small-cell lung cancer (Radiation Therapy Oncology Group 88-08) were calculated with and without density correction. Tumor doses were analyzed for 322 patients and 1236 separate fields. RESULTS: For the benchmark problem studied here, the overall correction factor for a four-field treatment varied significantly with energy, ranging from 1.14 (60Co) to 1.05 (24 MV) for measured doses, or 1.17 (60Co) to 1.05 (24 MV) for doses calculated by conventional density-correction algorithms. For the patient data, overall correction factors (calculated) ranged from 0.95 to 1.28, with a mean of 1.05 and distributional standard deviation of 0.05. The largest corrections were for lateral fields, with a mean correction factor of 1.11 and standard deviation of 0.08. CONCLUSIONS: Lung inhomogeneities can lead to significant variations in delivered dose between patients treated in a clinical trial. Existing density-correction algorithms are accurate enough to significantly reduce these variations.

Algorithms

Multiple machine implementation of enhanced dynamic wedge.

PURPOSE: After acquiring 4 years of experience with Dynamic Wedge, a software-driven one-dimensional (1D) compensation system, we implemented a new software version called Enhanced Dynamic Wedge (EDW). The EDW allows larger (30 cm) and asymmetric field sizes and additional angles for wedged fields. We implemented this software on four similar dual-energy accelerators that also possess upper and lower physical wedge sets. Our goal was to implement EDW with one common wedge factor (WF) table and one set of treatment-planning files. METHODS AND MATERIALS: We measured WFs with an ionization chamber and isodose profiles with both film and a diode array. We used a calculation scheme that requires only entry of the wedge angle and fixed jaw value. Filters for computerized treatment planning were configured for each wedge angle. We also examined to what degree the multileaf collimation (MLC) orientation, which is orthogonal to the EDW direction, was compromised for specific treatment sites. As a comparative test, we examined the dosimetric consistency for the 8 sets of physical wedges on the four machines. Finally, we updated our DW quality assurance program for EDW. RESULTS: The measured EDW WF was common for all four machines to within +/- 1.5% and the calculation scheme held to within 1.5%. The EDW isodoses were consistent among the machines as measured by film and diode array. The treatment-planning filters provided computed isodose profiles that were nearly identical to measured profiles. Regarding MLC orientation, we found that the collimator angle needed for EDW did not compromise isodose distributions, as apparent in measured isodoses and calculated dose-volume histograms. The consistency of the physical wedges did not fare as well. Two of the lower wedge sets had Wfs and profiles different (> 3%) from the other wedge sets. CONCLUSIONS: We have successfully implemented EDW on four machines using only one WF table and one set of treatment-planning filters. The EDW provides for improved treatment techniques for particular sites due to the large field sizes and additional angles available. Daily treatment efficiency has increased because of the remote capability provided by EDW.

Humans

Geometric and dosimetric analysis of multileaf collimation conformity.

BACKGROUND AND PURPOSE: There is concern over the stepped edges of multileaf collimator (MLC) fields for target coverage compared with those of cerrobend. Despite recent reports dispelling this concern, users are still cautious when using MLCs for small fields. Leaf orientation can be a problem if one is required to orient the leaves along an axis not ideal for conformity (such as dynamic or universal wedge cases). In this study we examined the dependence of MLC field conformity on field size and elongation. MATERIALS AND METHODS: We examined circles of varying diameter and ellipses of varying eccentricity with leaves oriented along the major and minor axes of ellipses. The tests were both geometric, comparing areas of overblocking or underblocking (leaves inside and outside the field), and dosimetric, using radiographic films at depth in the beam's eye view plane. RESULTS: For the geometric comparison there is a rapid increase in non-conformity, defined as the percentage of overblocking or underblocking area, as the circle diameter decreases. For ellipses, when the leaves move along one axis direction, the conformity does not depend on the diameter of the same axis, but instead improves as the dimension of the axis in the non-leaf motion direction increases. The best conformity is achieved when the maximum number of leaves is used to shape the field. When the dosimetry is analyzed, the predictability of these trends decreases due to the impact of undulations (scatter), leaf inaccuracies and dosimetric uncertainties. CONCLUSIONS: We recommend that for small round fields MLC should be used with caution and that for ellipses the direction of leaf movement should be aligned with the minor axis whenever possible. Though these experiments are for idealized geometries, the observations can be applied to clinical fields. An MLC with a thinner leaf width could be beneficial for small round fields.

Humans

Modulated electron beams using multi-segmented multileaf collimation.

BACKGROUND AND PURPOSE: Conformal radiation therapy by modulation of photon and electron beams has been described for many techniques. Modulation of electron beams with the use of either bolus or altered scanned beams is reported. Our institution previously investigated the use of MLC for fixed static electron fields. The results were dismal due to the wide penumbra associated with multileaf collimated electrons scattered from foils. The purpose of this study was to decipher whether multi-segmented electron beams using MLC would provide a useful and practical modulated beam by taking advantage of matching the diffuse beam edges. MATERIALS AND METHODS: We started by planning simple target shapes, such as wedged and parabolic shapes. We optimized the segment widths, weights, gaps between segments and energies. We then irradiated phantoms using film to confirm the calculations. The study was limited to single-plane irradiation. We also planned and measured isodoses for a parotid target volume that possessed varying depths from surface to medial aspect. RESULTS: We found that we could optimize distributions by using the treatment depth and points of inflection to derive optimal segments. The planned treatments using a simple CET (coefficient of equivalent thickness) algorithm were confirmed with reasonable success. A 24 cm wide target was treated with nine segments in under 5 min, while most cases, including the parotid volume, were treated in under 3 min. CONCLUSIONS: We have developed a technique to complement a photon modulation program by treating lesions close to the surface. The debate as to whether this technique is optimal and more efficient than a bolus technique continues. We are currently devising methods for optimizing modulated electron MLC beams in multiple planes.

Electrons

1995 survey of physics teaching efforts in radiation oncology residency programs.

A physics teaching survey was constructed and sent to the 83 radiation oncologist training programs. The survey requested program information regarding size, staffing, curriculum, lab/rotation programs, organization, requirements, instructor makeup, teaching materials, and board certification examination results. The surveys were sent to the physicist responsible for the physics program. Forty-nine (59%) institutions returned completed surveys, of which 43 (88%) were university-associated programs, and 27 (55%) were 4-year programs. On average, there were two residents/year. Most programs (39) taught physics exclusively during the first year (PG2). Some programs taught different subjects (or levels) to different year residents. Radiation dosimetry, treatment planning, and brachytherapy constituted nearly half of the teaching hours. On average the total classroom time expended by physicists was 61.4 h/year with a range of 24-118 h. The mean for laboratory/demonstration time was 27 h/year with 18 programs providing none. Physics orientation/rotations ranged from 1 to 480 h with a mean of 170 h for a physics rotation taking place in year 2 (PG3). Mandatory attendance was 80% for first-year residents and decreased in later years. Homework was assigned in 76% of the programs, and 65% of the programs were graded. The primary instructors averaged 18.2 years of experience, and the majority were ABR/ABMP certified. Khan's textbook was the most prevalent resource for most subjects. No correlation could be made between teaching hours and ABR physics percentile scoring. The survey results reveal enormous differences in national teaching efforts.

Curriculum

A volumetric study of measurements and calculations of lung density corrections for 6 and 18 MV photons.

PURPOSE: For treatment of lung cancer, dose heterogeneity corrections and subsequent prescription alteration remain controversial. Previous dosimetry studies based on slab geometry with a single beam geometry do not represent the clinical situation. A circumscribed tumor within lung poses a more complex problem. Energy choice also remains controversial. METHODS AND MATERIALS: An anthropomorphic phantom was modified by replacing lung cylinders (2.5 and 5.0 cm diameters by 5.0 cm length) with muscle-equivalent cylinders. The phantom was scanned on a CT simulator. Gross, clinical, and planning target volumes (GTV, CTV, PTV1 including tumor and regional nodes, PTV2 including tumor only) were designated slice-by-slice. Three-dimensional planning was performed with large fields (AP/PA/RPO) covering PTV1 and boost fields optimized for each PTV2, for 6 and 18 MV photons. Homogeneous, Ratio-Tissue-Air-Ratio (RTAR), and convolution-adapted RTAR (CARTAR) calculation algorithms were tested. Film was placed between phantom slices at the "tumor" levels. The phantom was irradiated with monitor units corresponding to homogeneous calculations, based on a homogeneous prescription. Measured and calculated doses were compared by isodoses and dose volume histograms. Ionization chambers and TLDs were also used for some test cases. RESULTS: The measured minimum dose covering PTV2 was within 5% of the homogeneous prescription dose of 70 Gy for 6 MV photons, while a lower dose (89% of prescription dose) was measured for 18 MV. The algorithms overpredicted the minimum dose to PTV2 by 6-18%. If the monitor units had been reduced according to simplistic heterogeneous calculations, the small PTV2 would have only been covered by 58 Gy for 18 MV irradiation. Based on this, a clinician may opt to actually increase the prescribed dose, thereby offsetting decreased monitor units. None of the algorithms predicted the diffuse penumbra associated with 18 MV photons in lung. CONCLUSION: Before adjusting dose prescriptions based on heterogeneity corrections, realistic phantom studies must be performed. The accuracy and effect of the corrections must then be assessed. The deficient coverage of PTV2 by the 18 MV beam compares unfavorably with the slight increase (5%) in hot spots associated with 6 MV. Our studies support strong caution before reducing dose prescriptions based on simple algorithms.

Algorithms

Surface and peripheral doses of dynamic and physical wedges.

PURPOSE: The physical and dosimetric differences between three different wedge systems on a multileaf collimator (MLC) equiped linear accelerator are discussed in this report. In particular, the in-field and peripheral surface doses from these wedge systems are measured and their clinical differences discussed. METHODS AND MATERIALS: A parallel-plate chamber was used in a solid water phantom to measure the surface doses of the wedges. Published correction factors were used to convert relative ionization to relative surface dose. Measurements were performed for 6 and 18 MV photon beams for different field sizes, source-surface distances (SSD), and distances outside the field for peripheral dose measurements. Surface-dose profiles across a field in the wedge-gradient direction were measured for the dynamic and upper wedges. Dose profiles in the nonwedge gradient direction were measured for open beam as well as the three wedges using films at depths of maximum dose (d(max)). RESULTS: At 85 cm SSD, surface doses on the central axis under a dynamic wedge or upper wedges are similar to those of an open field, while those of a lower wedged field are as much as 100% higher. Differences in surface doses due to beam energy are relatively minor compared with differences due to SSD or wedge systems. Dynamic and upper wedges produce similar peripheral doses, much lower than those produced by the lower wedges. The surface dose profile across the field under the dynamic wedge has a higher slope than that under the upper wedge, when the difference in wedge angles is compensated for by normalization to the dose profile at d(max). In the nonwedge gradient direction, the dose profiles at d(max) of both the upper and the lower wedges demonstrate a marked effect of oblique filtration of the primary beam, resulting in an off-axis ratio at 80% of the field width of 0.95, in contrast to the off-axis ratio of 1.05 in the open and the dynamic wedged fields. CONCLUSIONS: The three wedge systems produce significantly different surface and peripheral doses that should be considered in properly choosing a wedge system for clinical use. Dynamic wedge and upper wedge systems deliver surface and peripheral doses similar to those of open fields and much lower than the lower wedge system. Both physical wedge systems degrade beam profiles in the nonwedged direction.

Equipment Design

The incidence of breast cancer following mantle field radiation therapy as a function of dose and technique.

BACKGROUND: There is an increased incidence of breast cancer following mantle field radiation therapy for Hodgkin's disease (HD). We reviewed the experience at the Mallinckrodt Institute of Radiology (MIR) for radiation factors related to the development of breast cancer after mantle field radiation therapy for HD. METHODS: The radiation therapy records of 152 women treated with mantle field irradiation for HD at MIR between 1966-1985 were reviewed for the development of breast cancer and treatment-related factors. All patients had a minimum of 5 years of follow-up. The treatment era (1966-1974 vs. 1975-1985), stage of HD, mediastinal dose, axillary dose, maximum dose from the anterior field (anterior d(max) dose), the anterior-posterior:posterior-anterior (AP:PA) ratio, age at the time of treatment, length of follow-up, and history of splenectomy were analyzed as possible contributing factors for the development of breast cancer. The observed number of breast cancers was compared to the expected number based on age-adjusted incidences from the Connecticut Tumor Registry. RESULTS: Ten breast cancers occurred in the population. Eight involved an upper outer quadrant. In a multivariate analysis, the development of breast cancer was significantly associated with axillary dose. Patients in the early treatment era were at an increased risk for the development of breast cancer due to high anterior d(max) and breast doses from weighting the fields anteriorly on a low energy linear accelerator. The use of current radiation therapy techniques was not related to an increased risk of breast cancer with a median follow-up of 13 years. CONCLUSIONS: A high dose to the axilla and the anterior d(max) point is significantly associated with the development of breast cancer after mantle field irradiation for HD. Efforts to protect the breast from high doses will likely lessen the increased risk of breast cancer in women treated with radiation therapy for HD.

Adolescent

Treatment planning for enhanced dynamic wedge with the CMS focus/Modulex treatment planning system.

The current versions of the CMS treatment planning systems, the FOCUS system for three dimensional planning, and Modulex for two dimensional planning, both require modeling dynamic wedges as filters. In this paper we describe methods for generating dynamic wedge filters for treatment planning. In our previous work with dynamic wedge we used measured data to back project the filter that would have delivered the wedge shaped isodoses. With the current version of Enhanced Dynamic Wedge, we use the segmented treatment table (STT) to create filters. For each wedge angle we created a 30 cm filter, for which the field is truncated by blocks according to the dynamic jaw settings. We found the filters provided isodoses that were within 2 degrees of the measured angles. Central axis dose was within 1% due to the fact the system does not account for beam hardening. Although an undesirable solution to model dynamic wedging, we found the filter method to be workable.

Radiotherapy Planning, Computer-Assisted

An ultrasound system for simultaneous ultrasound hyperthermia and photon beam irradiation.

PURPOSE: An existing ultrasound system has been adapted for simultaneous use with external photon beam irradiation. The system is being used to investigate the potential for increased biological benefit of simultaneously combined hyperthermia and external beam irradiation with currently achievable temperature distributions. METHODS AND MATERIALS: An existing clinical ultrasound system has been modified for simultaneous operation with a 60Co teletherapy machine. The generator, thermometry system, computer, and applicators are located inside the treatment room, while the monitor and system control are located at the control console. Two approaches have been used clinically to combine the two modalities. In the first approach, an en-face setup is used in which the ultrasound beam and the photon beam travel through the same window of entry to the tumor. This is acheived by a reflecting system designed to deflect the ultrasound to the tumor while positioning the ultrasound transducer outside the radiation beam. The reflecting system consists of water and water-equivalent materials except for a 1 mm sheet of polished brass that is used as the reflector. The relative pressure fields were measured in water at the same distance from the ultrasound source using a scanning hydrophone with and without the reflector at the two operating frequencies of the device (1.0 and 3.4 MHz) for two applicators. Radiation dosimetry measurements were performed to determine the relationship between 60Co irradiation through the reflector and absorbed dose. In the second approach the ultrasound and the radiation beam travel into the tumor from different windows of entry such that the radiation beam passes through no portion of the water bolus prior to entering the patient. We have termed this approach the orthogonal approach. For both approaches, the radiation fraction is given in the middle of an uninterrupted 60-min hyperthermia treatment. RESULTS: The system modifications did not impair the ability to effectively deliver ultrasound hyperthermia or 60Co teletherapy. With the en-face approach the ultrasonic patterns generated with and without the reflector demonstrated that the ultrasound system maintained both a uniform and controllable heating pattern. The 60Co beam had no effect on the performance of the thermocouple thermometers. The radiation beam is attenuated nearly uniformly by the reflector system. To date, 10 patients have been treated with the en-face approach and 12 have been treated with the orthogonal approach (90 treatments). CONCLUSIONS: The clinical implementation of ultrasound hyperthermia simultaneous with 60Co irradiation is technically and clinically feasible without any complications or hazards to the patient. The implementation of a reflecting device allows en-face delivery of both the ultrasound and 60Co irradiation. Temperatures obtained during simultaneous treatments are comparable to those historically obtained during sequential treatments with the same commercial ultrasound device.

Calorimetry

Design and dosimetric characteristics of a high dose rate remotely afterloaded endocavitary applicator system.

PURPOSE: An applicator is described for endocavitary treatment of rectal cancers using a high dose rate (HDR) remote afterloading system with a single high-intensity 192Ir source as an alternative to the 50 kVp x-ray therapy contact unit most frequently used in this application. METHODS AND MATERIALS: The applicator consists of a tungsten-alloy collimator with a 45 degree beveled end, placed in a protoscope with an elliptical cross-section. The resultant 3 cm diameter circular treatment aperture, located in the beveled face of the proctoscope, is irradiated by circular array of dwell positions located about 6.5 mm from the applicator surface. This beveled end allows patients with posterior wall tumors to be treated in the dorsal lithotomy position. The dose-rate distributions about the applicator were determined using a combination of thermoluminescent dosimetry (TLD-100 detectors) and radiochromic film dose measurement techniques along with Monte Carlo dosimetry calculations. TLD-100 (3 x 3 x 0.9 mm3 chips) measurements were used to measure the distribution of dose over the proctoscope surface as well as the central axis dose-rate distribution. Relative radiochromic film measurements were used to measure off-axis ratios (flatness and penumbra width) within the treatment aperture. These data were combined with Monte Carlo simulation results to obtain the final dose distribution. RESULTS: The tungsten collimator successfully limits the dose to the tissue in contact with the proctoscope walls to less than 12% of the prescribed dose. These results indicate that the HDR applicator system has slightly more penetrating depth-dose characteristics than the most widely used contact therapy x-ray machine. Flatness characteristics of the two treatment delivery systems are comparable, although the HDR endocavitary applicator has a significantly wider penumbra. Finally, the HDR applicator has a lower surface dose rate (1.5-4 Gy/min of dwell time) compared to 9-10 Gy/min for the x-ray unit. CONCLUSIONS: An applicator system has been developed for endocavitary treatment of early stage rectal carcinoma that uses a single-stepping source HDR remote afterloading system as a radiation source. The advantages of the HDR-based system over x-ray therapy contact units currently used in this clinical application are (a) enhanced flexibility in applicator design and (b) widespread availability of single-stepping source HDR remote afterloading systems.

Brachytherapy

A quality assurance program for ancillary high technology devices on a dual-energy accelerator.

Our facility has added high-technology ancillary devices to our dual-energy linear accelerator. After commissioning and acceptance testing of dual asymmetric jaws, dynamic wedge, portal imaging, and multileaf collimation (MLC), quality assurance programs were instituted. The programs were designed to be both periodic and patient specific when required. In addition, when dosimetric aspects were affected by these technologies, additional quality assurance checks were added. Positional accuracy checks (light and radiation) are done for both asymmetric jaws and MLC. Each patient MLC field is checked against the original simulation or digitally reconstructed radiographs. Off-axis factors and output checks are performed for asymmetric fields. Dynamic wedge transmission factors and profiles are checked periodically, and a patient diode check is performed for every new dynamic wedge portal. On-line imaging checks encompass safety checks along with periodic measurement of contrast and spatial resolution. The most important quality assurance activity is the annual review of proper operation and procedures for each device. Our programs have been successful in avoiding patient-related errors or device malfunctions. The programs are a team effort involving physicists, maintenance engineers, and therapists.

Engineering

Feasibility study of multileaf collimated electrons with a scattering foil based accelerator.

BACKGROUND AND PURPOSE: There is an ever evolving process to improve the technical aspects of electron beam delivery. Both the foil/applicator and scanning electron beam systems have gone through recent upheavals. Concomitantly, multileaf collimators are now a staple method for collimating photons. We undertook a study of multileaf collimated electron beam (MLCEB) using a dual scattering foil system. MATERIALS AND METHODS: We compared MLCEB with applicator collimated electron beams (AEB) by examining the dosimetric aspects of the two systems using 70 and 80 cm SSDs for the MLCEB, the minimum practical SSDs achievable. Percent depth dose, isodose profiles, output factors, leakage, surface dose, bremstrahlung, effective SSDs, etc. were measured using film and/or ion chamber. Clinical fields, such as posterior neck node (PNN), were compared. We also investigated the use of MLCEB for arc therapy using segments. RESULTS: In all cases, the MLCEB performed inferior, as judged by isodoses, uniformity index (UI) and penumbra analysis. The 80 cm SSD (minimum for PNN), low energy, small fields, was the worst case. For a 6 MeV beam, the UI/penumbra was 0.823/10 mm for the AEB, and 0.561/29 mm for the MLCEB at 80 cm SSD. The PNN multileaf fields exhibited narrow 90% and 80% isodose lines, and wide 20% and 10% lines. CONCLUSIONS: We conclude that multileaf for PNN fields could not be matched to adjacent off-cord photon fields. The "stair-stepping' effect associated with MLC photons was absent for electrons.

Electrons

Verification of milled two-dimensional photon compensating filters using an electronic portal imaging device.

A computer-driven milling machine is being installed at the Mallinckrodt Institute of Radiology to fabricate photon compensating filters for conventional compensation and beam-intensity modulation. Commissioning and quality assurance procedures are being developed for the design, fabrication, and delivery systems prior to using the milled filters in the clinic. The portion of the quality assurance procedures governing the filter fabrication using a computer-driven milling machine includes, in part, a comparison of designed and fabricated filters. Test filters include geometrically regular filters, such as flat surfaces and steps. The verification of these shapes is accomplished using spatial measurements. However, to test the mill's ability to generate complex curved surfaces, filters with more complicated surfaces are generated. These filters do not lend themselves to precise verification using physical measurement of the thickness distribution. A method has been developed to verify the thickness distributions of these complex filters by irradiating the filters with high-energy x rays and comparing the scattered and transmitted fluence to the fluence calculated using the intended filter shape. The fluence measurement is made using a calibrated commercial liquid ionization chamber electronic portal imaging device. The calculated fluence is separated into transmitted primary and scattered fluences and is determined using a convolution of a distributed radiation source kernel with an exponential filter attenuation function. The attenuation coefficient is measured for the filter material (Lipowitz metal) and fit to a second-order polynomial in filter thickness and off-axis distance. The distributed source kernel is measured using a split-field technique and fit to a sum of three two-dimensional Gaussian distributions. The scattered radiation is modeled by the Klein-Nishina cross section. The algorithm is tested by comparing calculated fluences with measured fluences for a series of machined filters: an open field, flat filters of 9.6-, 15.8-, and 31.6-mm thickness, split-field filters, and a pyramid-shaped filter. In each case, the algorithm calculates the fluence to within 3% of the measured values over the entire irradiated field size to within 1.5 cm of the collimated field edges.

Algorithms

Clinical implementation of a commercial multileaf collimator: dosimetry, networking, simulation, and quality assurance.

PURPOSE: Clinical implementation of multileaf collimation (MLC) includes commissioning (including leaf calibration), dosimetric measurements (penumbra, transmission, calculation parameters), shaping methods, networking for file transfer, verification simulation, and development of a quality assurance (QA) program. Differences of MLC and alloy shaping in terms of penumbra and stair-step effects must be analyzed. METHODS AND MATERIALS: Leaf positions are calibrated to light field. The resultant decrement line, penumbras, leaf transmission data, and isodoses in various planes were measured with film. Penumbra was measured for straight edges and corners, in various media. Ion chambers were used to measure effects of MLC on output, scatter, and depth dose. We maintain midleaf intersection criteria. MLC fields are set 7 mm beyond planning target volumes. After shaping by vendor software or by our three-dimensional planning system, files are transferred to the MLC workstation by means of sharing software, interface cards, and cabling. A MLC emulator was constructed for simulation. Our QA program includes file checks, monthly checks (leaf position accuracy and interlock tests), and annual review. RESULTS: We found the MLC leaf position (light field) corresponds to decrement lines ranging from 50 to 59%. Transmission through MLC (1.5-2.5%) is less than alloy (3.5%). Multileaf penumbra is slightly wider than for alloy. Relative penumbra did not increase in the lung, and composite field dosimetry exhibited negligible differences compared with alloy. Verification simulations provide diagnostic image quality hard copies of the MLC fields. Monitor unit parameters used for alloy held for MLC. DISCUSSION: Clinical implementation for MLC as a block replacement was conducted on a site-by-site basis. Time studies indicate significant (25%) in-room time reductions. Through imaging and dosimetric analysis, the accuracy of field delivery has increased with MLC. The most significant impact of MLC is the ability to increase the number of daily treatment fields, thereby reducing normal tissue dosing, which is vital for dose escalation.

Calibration