PubMed Health⌕ Search

Biomedical subjects

E E Solien

Publications and source records attributed to E E Solien.

7 recordsLinked to original sources

Ventriculocoronary artery bypass results using a mesh-tipped device in a porcine model.

BACKGROUND: In this report we describe the in vivo evaluation of a device and ventriculocoronary artery bypass procedure that creates a permanent transmyocardial channel between the left ventricle and a coronary artery. METHODS: The transmyocardial device, an L-shaped titanium tube with a meshed distal tip and an exterior polyester cuff, was implanted from the base of the left ventricle to the proximal left anterior descending coronary artery in 11 healthy juvenile domestic pigs using a beating-heart approach. Flow rates were measured at implant. Patency was assessed at explant for surviving animals at 2 (n = 3) and 4 weeks (n = 4). RESULTS: Flow through the transmyocardial device after implantation was 74% of base line. Forward flow occurred during systole. Luminal patency was 100% at 2 weeks and 75% at 4 weeks. Histologic analysis showed little to no intimal proliferation at the coronary interface. CONCLUSIONS: This short-duration study shows promise for perfusing ischemic myocardium with systolic flow. The transmyocardial titanium conduit and treated coronary artery patency was good at 2 and 4 weeks and warrants further studies.

Animals↗

Ventriculocoronary artery bypass (VCAB), a novel approach to myocardial revascularization.

BACKGROUND: The long-term patency rate of saphenous vein grafts for myocardial revascularization is poor (50% at 10 years). Half of the patent grafts develop severe atherosclerosis. In this paper, we report on an implantation technique and an in vivo evaluation of a device that creates a ventriculocoronary artery bypass (VCAB), a permanent transmyocardial channel between the left ventricle and a coronary artery. METHODS: An L-shaped titanium tube with an exterior polyester cuff was implanted from the base of the left ventricle to the proximal left anterior descending coronary artery in 11 juvenile domestic pigs using a beating heart approach. Flow rates were measured at implantation. Patency was assessed when explanted at 2 weeks. RESULTS: The flow rate through the device after implantation was 76% of baseline. Forward flow occurred during systole. The patency rate was 91% at 2 weeks. Histologic analysis showed the formation of an organizing tissue at the coronary interface. CONCLUSIONS: These preliminary studies show the promise of perfusing ischemic myocardium with systolic flow. Patency of the transmyocardial titanium conduit was excellent at 2 weeks and warrants longer duration studies.

Anastomosis, Surgical↗

Surfactant dysfunction in lung preservation.

We studied the effect of lung preservation on the surfactant system in rats. Lung surfactant is necessary to maintain normal lung mechanics, and hence normal lung function. We evaluated lung mechanics with pressure-volume (P-V) curves, and analyzed biochemical changes of surfactant in bronchoalveolar lavage (BAL) fluid. Additionally, we determined wet to dry weight ratios (W/D). We defined five study groups. In group I (controls) we harvested lungs without pulmonary artery flushing, then evaluated them immediately. In group II we flushed lungs through the pulmonary artery (PA) with hypothermic modified Euro-Collins solution (mECS), then removed and studied them immediately to determine the consequences of PA flushing alone. In groups III, IV, and V we flushed lungs with mECS, then stored them in normal saline (NS) for 6 hr (group III); in NS for 12 hr (group IV); or in mECS for 12 hr (group V). In groups III, IV, and V we evaluated lungs after storage. All four experimental groups showed significant changes in lung mechanics and surfactant biochemistry, compared with controls. Lungs in groups III, IV, and V showed additional changes in lung mechanics and surfactant biochemistry compared with group II. The W/D in stored lungs (groups III, IV, and V) was significantly higher than in controls and group II. We conclude that lung preservation induces deleterious changes in the surfactant system. Surfactant alterations are evident immediately after pulmonary artery flushing, and increase in severity with storage.

Animals↗

Intra-aortic balloon counterpulsation augments cerebral blood flow in a canine model of subarachnoid hemorrhage-induced cerebral vasospasm.

We tested the effect of intra-aortic balloon counterpulsation (IABC) on cerebral blood flow (CBF) in a canine model of cerebral vasospasm. Cerebral vasospasm was induced in ten adult mongrel dogs using a "two-hemorrhage" model. CBF was then measured using radiolabeled microspheres, before and after activation of an intra-aortic balloon pump. Physiologic parameters including pCO2 and cardiac filling pressures were maintained constant during the experiment. Cardiac output was monitored in each animal. CBF increased with IABC in all ten animals. The mean CBF was 78.5 milliliters per 100 grams per minute (ml/100g/min) before versus 93.3ml/100g/min after IABC (P = 0.0001). Increases in CBF were associated in most, but not all, cases with increases in cardiac output. This study supports the ability of IABC to raise CBF in the setting of cerebral vasospasm. IABC may represent an important clinical option in cases of refractory vasospasm following aneurysmal subarachnoid hemorrhage.

Animals↗

Conformational adaptation of muscle: implications in cardiomyoplasty and skeletal muscle ventricles.

In dynamic cardiomyoplasty and other forms of muscle-powered cardiac assist, the stretch that should be applied to the skeletal muscle to obtain optimal resting tension remains unclear. To test the hypothesis that skeletal muscle is capable of conformational adaptation over time, the effect of altered resting tension on the chronic performance of a skeletal muscle ventricle was studied. In 7 mongrel dogs, skeletal muscle ventricles constructed from the lastissimus dorsi muscle were stimulated to contract for 12 weeks against an implantable mock circulation. The preload pressure was altered, thereby varying the resting tension of the latissimus dorsi. One group (group I; n = 5) was maintained at a preload of 80 mm Hg, whereas a second group (group II; n = 2) was maintained at 20 mm Hg. Adaptation to preload was observed. After 12 weeks, the pressure increase generated by the skeletal muscle ventricle at a preload of 20 mm Hg was only 35 +/- 2 mm Hg for group I compared with 44 +/- 5 mm Hg for group II. At a preload of 80 mm Hg, the pressure increase was 61 +/- 4 mm Hg for group I and only 34 +/- 6 mm Hg for group II. Adaptation of the latissimus dorsi to a new resting tension has important implications in the use of skeletal muscle for cardiac assist. Stretching the latissimus dorsi to its in situ length during cardiomyoplasty is not required for future muscle performance to be optimal.

Adaptation, Physiological↗

Importance of adaptive stimulation of the latissimus dorsi muscle in cardiomyoplasty.

During cardiac synchronized latissimus dorsi (LD) stimulation, adaptive duration (AD) allows the pulse train length to be set as a percentage of the cardiac cycle. The LD contraction duration adjusts to variations in heart rate (HR). The effects of AD on LD work output and blood flow (BF) were investigated in nine dogs that underwent skeletal muscle ventricle (SMV) construction. The SMVs were stimulated according to the cardiomyoplasty protocol. BF and the pressure increase (delta P) generated during SMV contraction were monitored biweekly for 3 months. SMV contraction time increased significantly after training (P < 0.0001). The trained SMV could only partially contract at duration settings of 25% and 30%. Before training, the increase in mean pressure and BF during 35% AD increased proportionally with increasing HR. After training, BF and mean pressure decreased with increasing HR because of reduced peak pressure generation during partial SMV contractions. When duration was fixed at 200 msec, BF increased with HR to 80 bpm but decreased with additional increases in HR. At high rates and fixed duration, inadequate relaxation between contractions resulted in the inefficient muscle performance and reduced BF. AD did not impair BF and allowed the appropriate autoregulatory response to occur in the trained and untrained LD so that the supply-to-demand ratio did not become compromised over a large range of HR.

Adaptation, Physiological↗

Blood flow to the latissimus dorsi muscle pouch during chronic counterpulsation stimulation.

The cyclic contraction of a skeletal muscle ventricle (SMV) stimulated in counterpulsation results in phasic perfusion of the muscle. Perfusion will occur primarily during cardiac systole when the muscle is relaxed. However, the resting preload of the SMV will be systolic arterial pressure, which will impede blood flow to the relaxed muscle. To determine the effect of chronic counterpulsation stimulation on the blood flow to an SMV and identify stimulation regimens that prevent the risk of chronic ischemia, SMVs were created in four mongrel dogs by implementing an implantable mock circulation device. The SMV was stimulated in counterpulsation for 4 weeks after a 2-week vascular delay period and 2 weeks of low-frequency muscle conditioning. During biweekly studies, the muscle was stimulated in four modes against preloads varying from 20 to 120 mm Hg. Resting blood flow decreased significantly at preloads greater than 60 mm Hg. Normalized blood flow increased between 10% and 30% during stimulation; greater increases corresponded to more demanding stimulation modes. The elevated blood flow during stimulation, however, decreased with increasing preload. Stroke work increased with increasing preload until preload exceeded 100 mm Hg. The decreased blood flow and increased stroke work occurring at higher preloads indicate that the supply/demand ratio becomes compromised with increasing preload. A hyperemic response occurred during the resting beats after a stimulated beat, increasing the volume blood flow by as much as 80%. This response occurred regardless of preload or stimulation rate. If the SMV relaxed before the onset of systole, a hyperemic response occurred within the stimulated beat.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗