PubMed Health⌕ Search

Biomedical subjects

E E Watson

Publications and source records attributed to E E Watson.

At least 19 recordsLinked to original sources

Stability of meperidine in an implantable infusion pump using capillary gas chromatography-mass spectrometry and a deuterated internal standard.

A capillary gas chromatographic-mass spectrometric (GC MS) method is described for the analysis of meperidine using 3,3,5,5-[2H4]-meperidine as an internal standard. Chromatography was performed on a (5% phenyl) methylpolysiloxane column (30 m x 0.32 mm I.D., 0.25 microm film thickness) operated at 195 degrees C; helium carrier gas-50 cm/s(-1), tR = 2.3 min. Ionization was by electron impact (EI) and detection by selected ion monitoring of the molecular ions. The method provided high response linearity (mean r = 0.9982) and precision (< 6.5% C.V.). Application of this method to a pilot study of aqueous meperidine x HCl (10 mg/ml(-1)) stability in a surgically implantable infusion pump at 37 degrees C for 90 days revealed no demonstrable drug degradation.

Analgesics, Opioid↗

The MIRD perspective 1999. Medical Internal Radiation Dose Committee.

The MIRD schema is a general approach for medical internal radiation dosimetry. Although the schema has traditionally been used for organ dosimetry, it is also applicable to dosimetry at the suborgan, voxel, multicellular and cellular levels. The MIRD pamphlets that follow in this issue and in coming issues, as well as the recent monograph on cellular dosimetry, demonstrate the flexibility of this approach. Furthermore, these pamphlets provide new tools for radionuclide dosimetry applications, including the dynamic bladder model, S values for small structures within the brain (i.e., suborgan dosimetry), voxel S values for constructing three-dimensional dose distributions and dose-volume histograms and techniques for acquiring quantitative distribution and pharmacokinetic data.

Humans↗

MIRD pamphlet No. 17: the dosimetry of nonuniform activity distributions--radionuclide S values at the voxel level. Medical Internal Radiation Dose Committee.

The availability of quantitative three-dimensional in vivo data on radionuclide distributions within the body makes it possible to calculate the corresponding nonuniform distribution of radiation absorbed dose in body organs and tissues. This pamphlet emphasizes the utility of the MIRD schema for such calculations through the use of radionuclide S values defined at the voxel level. The use of both dose point-kernels and Monte Carlo simulation methods is also discussed. PET and SPECT imaging can provide quantitative activity data in voxels of several millimeters on edge. For smaller voxel sizes, accurate data cannot be obtained using present imaging technology. For submillimeter dimensions, autoradiographic methods may be used when tissues are obtained through biopsy or autopsy. Sample S value tabulations for five radionuclides within cubical voxels of 3 mm and 6 mm on edge are given in the appendices to this pamphlet. These S values may be used to construct three-dimensional dose profiles for nonuniform distributions of radioactivity encountered in therapeutic and diagnostic nuclear medicine. Data are also tabulated for 131I in 0.1-mm voxels for use in autoradiography. Two examples illustrating the use of voxel S values are given, followed by a discussion of the use of three-dimensional dose distributions in understanding and predicting biologic response.

Animals↗

A history of medical internal dosimetry.

This paper presents a short history of the development of medical internal dosimetry. It reviews the evolution of the equations and discusses the development of various mathematical models used to improve radiation absorbed dose estimates. The contributions of Leonidas Marinelli, Edith Quimby, William Mayneord, Robert Loevinger, Walter Snyder, and others are emphasized.

History, 20th Century↗

Radiation dosimetry for the adult female and fetus from iodine-131 administration in hyperthyroidism.

Through a study of the iodine kinetics of 127 patients, we have developed radiation dose estimates to major organs and the fetus for patients with varying degrees of hyperthyroidism. We observed a negative correlation between maximum thyroid uptake and biologic half-time of iodine in the thyroid and used this correlation to predict the biologic half-time at fixed values of maximum thyroid uptake. Dose estimates to the bladder, gonads, marrow, thyroid, uterus, and whole body were estimated for maximum thyroid uptakes from 20% to 100%. Bladder dose varied from 0.6 to 1.0 mGy/MBq and dose to the uterus varied from 0.036 to 0.063 mGy/MBq under different model assumptions. Dose estimates to the fetus and fetal thyroid were approximated at all stages of pregnancy. Average fetal dose was a maximum between 0 and 2 mo of pregnancy, with the maximum ranging from 0.048 mGy/MBq to 0.083 mGy/MBq, depending on model assumptions. Some radiation risks for irradiation of the fetus and the fetal thyroid are discussed.

Adult↗

A model of the peritoneal cavity for use in internal dosimetry.

Several therapeutic and diagnostic techniques involve injection of radioactive material into the peritoneal cavity. Estimation of the radiation dose to the surface of the peritoneum or to surrounding organs is hampered by the lack of a suitable source region in the phantom commonly used for such calculations. We have modified the Fisher-Snyder phantom to include a region representing the peritoneal cavity which may be employed to estimate such radiation doses. A geometric model is described which is coordinated with the existing organ regions in the phantom. Specific absorbed fractions (derived by Monte Carlo techniques) for photon emissions originating within the cavity are listed. Photon S-values for several radionuclides which have been administered intraperitoneally are shown. Dose conversion factors for electrons irradiating the peritoneal cavity wall, from either a thin plane or volume source of activity within the cavity, are also given for several nuclides.

Electrons↗

Dosimetry of leukocytes labeled with 99Tcm-albumin colloid.

Biodistribution, kinetics and dosimetry of 9Tcm-albumin colloid labeled leukocytes (TAC-WBC) is described. A practical method of planar image data acquisition and processing is discussed. This method was used to obtain biodistribution data in 11 patients, two of whom were children. Dosimetry was calculated for fetuses, children and adults. The spleen is the critical organ, receiving 2.5 rad per 5 mCi procedure in adults and 3.6 rad per 2.15 mCi procedure in a 5-year-old child. These absorbed doses are about one-sixth of that absorbed from 111In-leukocytes procedures utilizing one-tenth the administered activity of TAC-WBC. The liver and red marrow are approximately equivalent secondary target organs, each receiving about 20% of the spleen dose. Fetal doses at any stage of gestation are similar, averaging about 14 mrad per mCi of TAC-WBC administered to the mother. The dosimetry of TAC-WBC is favorable enough to permit its use in children, adults and during pregnancy.

Adolescent↗

Hematologic depression following therapy with strontium-89 chloride.

Initial clinical trials using strontium-89 (Sr-89) chloride for the treatment of painful skeletal metastases have observed minimal or no hematological depression secondary to the radiostrontium. A patient with marked bone marrow depression temporally related to the administration of the Sr-89 is reported, and the need for close hematological monitoring is emphasized. Bone marrow tumor replacement may predispose patients to marrow depression from radiostrontium, and such patients should be treated with caution.

Aged↗

A new osmium-191/iridium-191m radionuclide generator system using activated carbon.

A new osmium-191/iridium-191m (191Os/191mIr) radionuclide generator system has been developed based on the absorption of K2OsCl6 (Os-IV) on 140-230 mesh heat-treated activated carbon. The generator is eluted with pH 2 saline solution containing 0.25 g/l Kl to give 191mIr in good yield. The generator eluent is neutralized to physiologic pH and isotonicity with Tris buffer immediately prior to i.v. injection. No scavenger column is required. As an example, elution of the prototype generator with a 2-ml bolus results in elution of 191mIr in approximately 18% yield with an 191Os breakthrough of only 2 X 10(-4)%/bolus. The prototype generator has consistent performance over a 2-wk period with no change in 191mIr yield or 191Os breakthrough. Loading of up to 1.5 Ci of 191Os results in no observed radiolysis. Continuous elution of this system is also possible with a mean 191mIr yield of 3.7%/ml and a mean 191Os breakthrough of 2 X 10(-5)%/ml at a flow rate of 12 ml/min. This new system represents a readily available source of 191mIr for radioangiography. Adsorbed radiation dose calculations indicate a total-body dose of only 3.9 mrad for a 100 mCi injected bolus.

Adsorption↗

Contribution of contaminant indium-114m/indium-114 to indium-111 oxine blood dosimetry.

Indium-114m and 114In appear as contaminants in commercial preparations of [111In]oxine at a level of about 0.05% at time of calibration (TOC). The contribution of these contaminants to the radiation absorbed dose from [111In]oxine leukocyte, platelet, and erythrocyte imaging procedures has been evaluated. When the absorbed dose from these contaminants is expressed as a percent of the 111In dose to the same organ from a given procedure, the contaminants contribute an additional 0.16 to 12% of the 111In dose, and in one case, that of the spleen from [111In]oxine labeled erythrocytes, they contribute an additional 33%. Commercial samples of aqueous-based [111In]oxine contain levels of 114mIn/114In sufficient to result in a mild to moderate increase in the absorbed radiation dose to the patient. Strict quality control procedures must be maintained by suppliers to prevent higher contamination levels. It is advisable to avoid using 111In products of this nature later than about 3 days after the time of calibration.

Blood Platelets↗

Histopathologic studies of the liver following intravenous colloidal 198Au therapy.

Histologic studies of liver tissue from 27 patients given up to 395 mCi (cumulative) of intravenous colloidal 198Au showed no definite radiation injury and no correlation between hepatic abnormalities and dose. Demonstration of aggregates of colloidal gold in the Kupffer cells was inconsistent, suggesting slow removal or dispersion. Although the liver ordinarily receives the highest radiation dose, the critical organ is the marrow. Results support the recent introduction of 198Au to supplement teletherapy for certain neoplasms diffusely infiltrating the liver. Apparently the beta distribution minimizes endothelial injury in large vessels, which has been shown to be the cause of radiation hepatitis.

Adolescent↗