PubMed Health⌕ Search

Biomedical subjects

E E de Lange

Publications and source records attributed to E E de Lange.

At least 19 recordsLinked to original sources

Hyperpolarized 3He MR lung ventilation imaging in asthmatics: preliminary findings.

Asthma is a disease characterized by chronic inflammation and reversible obstruction of the small airways resulting in impaired pulmonary ventilation. Hyperpolarized 3He magnetic resonance (MR) lung imaging is a new technology that provides a detailed image of lung ventilation. Hyperpolarized 3He lung imaging was performed in 10 asthmatics and 10 healthy subjects. Seven asthmatics had ventilation defects distributed throughout the lungs compared with none of the normal subjects. These ventilation defects were more numerous and larger in the two symptomatic asthmatics who had abnormal spirometry. Ventilation defects studied over time demonstrated no change in appearance over 30-60 minutes. One asthmatic subject was studied twice in a three-week period and had ventilation defects which resolved and appeared in that time. This same subject was studied before and after bronchodilator therapy, and all ventilation defects resolved after therapy. Hyperpolarized 3He lung imaging can detect the small, reversible ventilation defects that characterize asthma. The ability to visualize lung ventilation offers a direct method of assessing asthmatics and their response to therapy.

Adult↗

Dynamic spiral MRI of pulmonary gas flow using hyperpolarized (3)He: preliminary studies in healthy and diseased lungs.

An optimized interleaved-spiral pulse sequence, providing high spatial and temporal resolution, was developed for dynamic imaging of pulmonary ventilation with hyperpolarized (3)He, and tested in healthy volunteers and patients with lung disease. Off-resonance artifacts were minimized by using a short data-sampling period per interleaf, and gradient-fidelity errors were compensated for by using measured k-space trajectories for image reconstruction. A nonsequential acquisition order was implemented to improve image quality during periods of rapid signal change, such as early inspiration. Using a sliding-window reconstruction, cine-movies with a frame rate of 100 images per second were generated. Dynamic images demonstrating minimal susceptibility- and motion-induced artifacts were obtained in sagittal, coronal, and axial orientations. The pulse sequence had the flexibility to image multiple slices almost simultaneously. Our initial experience in healthy volunteers and subjects with lung pathology demonstrated the potential of this new tool for capturing the features of lung gas-flow dynamics.

Helium↗

Hyperpolarized noble gas MR imaging of the lung: potential clinical applications.

Hyperpolarized noble gases are a new class of MR contrast agent. Since the first hyperpolarized gas MR images of the lung were reported, there has been considerable interest in using hyperpolarized gas to obtain high spatial and temporal resolution images of the air spaces of the lung. In addition to static images of lung ventilation, new techniques are being developed using hyperpolarized gas to obtain dynamic, diffusion and oxygen concentration images of the lung. In this article, we review the potential clinical applications of pulmonary hyperpolarized gas MRI and discuss the preliminary findings in a variety of lung diseases. Hyperpolarized gas MRI has the potential to provide a comprehensive morphologic and functional assessment of the lung.

Asthma↗

Imaging and clinical characteristics of focal atrophy of segments 2 and 3 in primary sclerosing cholangitis.

BACKGROUND AND AIMS: Focal atrophy in primary sclerosing cholangitis (PSC) is usually thought to result from severe biliary stricture and focal biliary cirrhosis. Atrophy of the left lateral segments (segments 2 and 3) are striking when observed grossly. This type of atrophy may be subtle on cross-sectional imaging and by endoscopic retrograde cholangiopancreatography (ERCP) because of the peripheral location and compensatory hypertrophy of other parts of the liver. We examined 44 consecutive PSC patients to determine the incidence and clinical characteristics of this abnormality, and to correlate imaging studies with the gross appearance. METHODS: We reviewed all cases of PSC encountered over a 3 year period ascertained from the liver disease registry. Magnetic resonance imaging or CT images were re-examined for evidence of segment 2 and 3 atrophy. RESULTS: Four of 44 patients had focal segment 2 and 3 atrophy. These four had been confirmed laparoscopically or by inspection of the liver explant. The remaining segments of the liver were relatively spared of injury in two of the patients, and three of the four patients had preserved synthetic function without evidence of portal hypertension. While the abnormality is clearly visible on cross-sectional imaging, its peripheral location caused it to be an unobtrusive. Likewise, ERCP did not clearly reveal the abnormality on initial inspection. CONCLUSIONS: We conclude that focal atrophy of segments 2 and 3 is a sometimes early and subtle finding in PSC that may be overlooked in cross-sectional imaging or ERCP unless specifically sought.

Adult↗

Minimally invasive surgery for solitary parathyroid adenomas in patients with primary hyperparathyroidism: role of US with supplemental CT.

PURPOSE: To determine the role of ultrasonography (US) with supplemental computed tomography (CT) in patients with primary hyperparathyroidism who undergo minimally invasive surgery instead of conventional neck exploration. MATERIALS AND METHODS: US and CT were performed in 61 consecutive patients with primary hyperparathyroidism (part 1) to identify and localize solitary adenomas for resection by means of minimally invasive surgery and to provide a surgical road map. In part 2, involving 33 consecutive patients, CT was performed only when no solitary adenoma was identified with US or for road map information. Minimally invasive surgery was considered successful when serum calcium levels normalized and remained stable. RESULTS: In part 1, 46 definite solitary adenomas were found with US and two additional ones with CT. Minimally invasive surgery was successful in 45 patients and failed once. In part 2, US helped identify 23 solitary adenomas, and CT helped to find one. Minimally invasive surgery was successful in 22 patients and failed in two. Combined results in 94 patients demonstrated successful minimally invasive surgery in 67 (71%), with 64 of them selected with US alone (95% CI: 61, 80). The sensitivity of US in the diagnosis of solitary adenoma was 78% (95% CI: 67%, 86%), with a positive predictive value of 96% (95% CI: 88%, 99%). CONCLUSION: US examination of patients with primary hyperparathyroidism allowed successful selection for minimally invasive surgery in more than two-thirds of the cases, with additional CT useful chiefly for surgical road mapping.

Adenoma↗

Assessing the subtalar joint: the Brodén view revisited.

We prospectively evaluated subtalar inversion stress views (Brodén view) with inversion stress views on helical CT in a group of 10 patients with unilateral instability. The contralateral, asymptomatic ankle was used as control. All patients were examined with inversion stress views on plain stress radiography and helical CT. Subtalar tilt was demonstrated in all cases on conventional stress radiography. Helical CT didn't show tilting in any of the patients except in the subluxated posteromedial part of the subtalar joint. Our data do not support prior reports that the Brodén view is useful for screening patients with subtalar instability.

Adolescent↗

Antegrade ureteral stent placement: positioning without use of a retraction string.

PURPOSE: To evaluate a simple method of antegrade ureteral stent insertion allowing optimal positioning of the stent without the use of a retraction string. PATIENTS AND METHODS: Seventeen stents were placed in sixteen patients with ureteral obstruction. Materials included a long vascular introducer sheath and radiopaque markers on the tips of both the sheath and the pusher catheter. For optimal positioning of the proximal pigtail in the renal pelvis, the distal end of the sheath was used to hold a large portion of the pigtail in the extended state prior to its deployment. RESULTS: All stent placements were successful. In one case, the tip of the proximal pigtail was caught in a lower-pole calix. In another case, repeat stent placement was necessary because of recurrent stricture several months after removal of the first stent. All stents functioned properly, as demonstrated by follow-up nephrostography 2 or 3 days after each procedure. CONCLUSION: The insertion method we describe is simple, easy to perform, and fast and avoids the risks associated with the use of a retraction string.

Adult↗

Posttraumatic subchondral bone contusions and fractures of the talotibial joint: occurrence of "kissing" lesions.

OBJECTIVE: The objective of this study was to determine the presence and location of subchondral bone contusions, fractures, and "kissing" lesions of the talotibial joint after a sprain of the ankle shown on MR imaging. MATERIALS AND METHODS: We retrospectively reviewed the images of all consecutive patients who underwent MR imaging of the ankle after acute or recurrent sprain occurring between January and December 1997. The number and location of subchondral contusions or fractures revealed on MR imaging were recorded, and a comparison was made with the radiographs obtained for each patient. RESULTS: Of the 146 ankles, 42 osteochondral lesions were revealed on MR imaging in 26 ankles (18%) involving 23 patients. Twenty-three lesions were localized in the dome of the talus and 19, in the tibiofibular plafond. In 16 (11%) of the 146 ankles, the lesions were present in the opposing bones of the joint ("kissing" lesions). Only six of the 12 talar fractures and none of the tibial fractures involving the 26 ankles were seen on conventional radiography. CONCLUSION: Subchondral lesions in the talus and tibia are relatively common after ankle trauma, occurring in 18% of patients in our series. Kissing lesions were present in more than half of the lesions in these patients.

Adult↗

Safety profile of ultrasmall superparamagnetic iron oxide ferumoxtran-10: phase II clinical trial data.

The safety data from the phase II clinical trial of ferumoxtran-10, an ultrasmall superparamagnetic iron oxide contrast agent, are presented. One hundred and four patients with focal liver or spleen pathologies underwent ferumoxtran-10-enhanced magnetic resonance (MR) imaging at doses of 0.8, 1.1, and 1.7 mg Fe/kg. Overall, 15% patients reported a total of 33 adverse events, regardless of causality. The adverse events most frequently seen were dyspnea (3.8%), chest pain (2.9%), and rash (2.9%). No serious adverse events were reported during the 48 hour observation period. There were no clinically significant effects on vital signs, physical examination, and laboratory results. Ferumoxtran-10 is a safe and well tolerated MR contrast agent.

Contrast Media↗

A multisite phase III study of the safety and efficacy of a new manganese chloride-based gastrointestinal contrast agent for MRI of the abdomen and pelvis.

The purpose of this study was to evaluate the safety and efficacy of a manganese chloride-based oral magnetic resonance (MR) contrast agent during a Phase III multisite clinical trial. Two hundred seventeen patients were enrolled who were already scheduled for MRI of the abdomen and/or pelvis. In this group of patients, it was postulated that the use of an oral agent would better allow discrimination of pathology from bowel. Patients with known gastrointestinal pathology including peptic ulcer disease, inflammatory bowel disease, obstruction, or perforation were excluded to minimize confounding variables that could affect the safety assessment. Of these 217 patients, 18 received up to 900 mL of placebo, and 199 patients were given up to 900 mL of a manganese chloride-based oral contrast agent, LumenHance (Bracco Diagnostics, Inc.). Safety was determined by comparing pre- and post-dose physical examinations, vital signs, and laboratory examinations and by documenting adverse events. Efficacy was assessed by unblinded site investigators and two blinded reviewers who compared pre- and post-dose T1- and T2-weighted MRI scans of the abdomen and/or pelvis. In 111 (57%) of the 195 cases evaluated for efficacy by site investigators (unblinded readers), MRI after LumenHance provided additional diagnostic information. Increased information was found by two blinded readers in 52% and 51% of patients, respectively. In 44/195 cases (23%) unblinded readers felt the additional information would have changed patient diagnosis and in 50 patients (26%), it would have changed management and/or therapy. Potential changes in patient diagnosis or management/therapy were seen by the two blinded readers in 8-20% of patients. No clinically significant post-dose laboratory changes were seen. Forty-eight patients (24%) receiving LumenHance and four patients (22%) receiving placebo experienced one or more adverse events. Gastrointestinal tract side effects were most common, seen in 29 (15%) of LumenHance patients and in 3 (17%) of the placebo patients. LumenHance is a safe and efficacious oral gastrointestinal contrast agent for MRI of the abdomen and pelvis.

Abdomen↗

Lung air spaces: MR imaging evaluation with hyperpolarized 3He gas.

Thirty-two magnetic resonance imaging examinations of the lungs were performed in 16 subjects after inhalation of 1-2 L of helium 3 gas that was laser polarized to 10%-25%. The distribution of the gas was generally uniform, with visualization of the fissures in most cases. Ventilation defects were demonstrated in smokers and in a subject with allergies. The technique has potential for evaluating small airways disease.

Administration, Inhalation↗

Renal volume measurements: accuracy and repeatability of US compared with that of MR imaging.

PURPOSE: To determine the accuracy and repeatability of ultrasonography (US) with the ellipsoid formula in calculating the renal volume. MATERIALS AND METHODS: The renal volumes in 20 volunteers aged 19-51 years were determined by using US with the ellipsoid formula and magnetic resonance (MR) imaging with the voxel-count method by two independent observers for each modality. The observers performed all measurements twice, with an interval between the first and second examinations. The voxel-count method was the reference standard. Repeatability was evaluated by calculating the SD of the difference (method of Bland and Altman). RESULTS: Renal volume was underestimated with US by 45 mL (25%) on average. A comparable underestimation was found when the ellipsoid formula was applied to MR images. This indicates that the inaccuracy of US renal volume measurements (a) occurred because the kidney does not resemble an ellipsoid and (b) was not primarily related to the imaging modality. Intra- and interobserver variations in US volume measurements were poor; the SD of the difference was 21-32 mL. For comparison, the SD of the difference in reference-standard measurements was 5-10 mL. CONCLUSION: Use of US with the ellipsoid formula is not appropriate for accurate and reproducible calculation of renal volume.

Adult↗

In vitro measurement of kidney size: comparison of ultrasonography and MRI.

In this in vitro study, the accuracy and repeatability of magnetic resonance imaging (MRI) and ultrasound (US) in assessing renal length and volume were determined. US and MR images of 20 cadaver pig kidneys were obtained twice and evaluated by two observers for each modality. The fluid displacement method provided the "gold standard." Renal volumes were calculated from the US and MR images using the ellipsoid formula. Additional volume calculations after segmentation of the kidney on MR images were done using the voxel-count method. Volumes calculated with the ellipsoid formula resulted in an average of 24% underestimation (range 5%-48%) of the renal volume for both US and MRI. With the voxel-count method, no significant deviation from the true renal volume was encountered. Repeatability was also greatest with the voxel-count method. Measuring renal length, repeatability was, again, better with MRI compared to US. For reliable calculation of renal size in vitro, MRI with use of the voxel-count method is preferred.

Animals↗

Renal artery stenosis and accessory renal arteries: accuracy of detection and visualization with gadolinium-enhanced breath-hold MR angiography.

PURPOSE: To determine the accuracy of gadolinium-enhanced breath-hold magnetic resonance (MR) angiography in the diagnosis of renal artery stenosis and visualization of accessory renal arteries. MATERIALS AND METHODS: Forty-four patients suspected of having renal artery stenosis and 10 potential kidney donors, all of whom were scheduled to undergo elective intraarterial digital subtraction angiography (DSA), were studied. Three-dimensional gradient-echo gadolinium-enhanced MR angiography was performed at 1.5 T with the following parameters: repetition time, 13.5 msec; echo time, 3.5 msec; flip angle, 60 degrees; 195 x 512 matrix; 400-mm field of view; and 6-cm imaging volume consisting of 15 4-mm-thick partitions reconstructed every 2 mm. Gadopentetate dimeglumine (30 mL) was injected with a power injector. MR angiograms were assessed before the standard of reference, intraarterial DSA, was performed. RESULTS: Four MR angiograms were not evaluable because of poor image quality. MR angiography enabled visualization of all but one of the 121 arteries. In four small accessory arteries, a stenosis could not be excluded owing to inadequate spatial resolution. MR angiography enabled the correct diagnosis in 30 of the 31 arteries with a grade 2 (50%-99%) stenosis and in seven of the 10 occluded arteries. Sensitivity and specificity for correct identification of a grade 2 stenosis were 97% and 92%, respectively. CONCLUSION: Gadolinium-enhanced MR angiography is an accurate, minimally invasive method for detecting renal artery stenosis and is reliable for visualizing accessory renal arteries.

Adult↗

Effect of age on cerebral blood flow: measurement with ungated two-dimensional phase-contrast MR angiography in 250 adults.

PURPOSE: To determine the normal values and effects of age and sex on total cerebral blood flow (CBF) as measured with ungated two-dimensional phase-contrast magnetic resonance (MR) angiography. MATERIALS AND METHODS: Volume flow rates in the basilar artery and both internal carotid arteries were measured on two-dimensional phase-contrast MR angiograms obtained in 250 subjects (age range, 19-88 years; mean age, 50 years) undergoing MR imaging because of indications other than cerebrovascular disease. Volume flow rates for the three arteries were summed to obtain the total CBF, and the values were analyzed in terms of age and sex. RESULTS: Mean total CBF was 616 mL/min +/- 143. There was a significant yearly decrease with age in total CBF of 4.8 mL/min (P < .001). Mean total CBF ranged from 748 mL/min +/- 121 to 474 mL/min +/- 105 in subjects aged 19-29 and 80-89 years, respectively. No sex differences were found. Mean relative contributions of the right and left internal carotid arteries and the basilar artery to total CBF were 41%, 40%, and 19%, respectively, with no substantial change due to age. CONCLUSION: Ungated two-dimensional phase-contrast MR angiography is a useful, noninvasive technique for assessing total CBF. By using this technique, a significant decrease in total CBF with age was demonstrated.

Adult↗

Hepatocellular carcinoma in North America: a multiinstitutional study of appearance on T1-weighted, T2-weighted, and serial gadolinium-enhanced gradient-echo images.

OBJECTIVE: The purpose of this study was to define the common appearances of hepatocellular carcinoma (HCC) in patients in North America by analyzing T1-weighted, T2-weighted, and serial gadolinium-enhanced gradient-echo images interpreted by radiologists at multiple institutions in North America. MATERIALS AND METHODS: One hundred thirteen consecutive patients with HCC from eight institutions were included in this retrospective case series. Inclusion criteria included MR imaging examinations performed on 1.5-T MR imagers using T1-weighted breath-hold spoiled gradient-echo images, T2-weighted images, and serial gadolinium-enhanced spoiled gradient-echo images. Diagnosis was established by histology in all patients. Images were analyzed retrospectively for lesion count, lesion diameter as less than or equal to 1.5 cm and greater than 1.5 cm, and signal intensity, by individual experienced radiologists at each institution. RESULTS: We found 354 HCC lesions in the 113 patients. Tumors were solitary in 63 patients, multifocal in 45 patients, and diffuse in five patients. Lesion appearance on combined T1-weighted, T2-weighted, and immediate gadolinium-enhanced spoiled gradient-echo images was as follows: 102 lesions (29%) were hypointense on T1-weighted images, were hyperintense on T2-weighted images, and exhibited diffuse heterogeneous enhancement; 52 lesions (15%) were isointense on both T1- and T2-weighted images and exhibited diffuse homogeneous enhancement (all of these lesions measured < or = 1.5 cm in diameter); 50 lesions (14%) were hypointense on T1-weighted images, were hyperintense on T2-weighted images, and exhibited diffuse homogeneous enhancement; 33 lesions (9%) were hypointense on T1-weighted images, were hyperintense on T2-weighted images, and exhibited predominantly peripheral rim enhancement; and 27 lesions (8%) were hypointense on T1-weighted images, were isointense on T2-weighted images, and exhibited diffuse homogeneous enhancement. The remaining 90 lesions showed less common patterns. The appearance of HCCs greater than 1.5 cm and of HCCs less than or equal to 1.5 cm was significantly different (p = .001). The appearance of histologically proven HCCs is separately described. CONCLUSION: The combination of hypointensity on T1-weighted images, hyperintensity on T2-weighted images, and diffuse heterogeneous enhancement was the most common appearance of HCC on MR images in a multiinstitutional patient population in North America. Small HCCs measuring less than or equal to 1.5 cm were frequently isointense on both T1-weighted and T2-weighted images and may be detected on immediate gadolinium-enhanced images only as diffuse homogeneously enhancing lesions.

Adolescent↗

MR imaging and spectroscopy using hyperpolarized 129Xe gas: preliminary human results.

Using a new method of xenon laser-polarization that permits the generation of liter quantities of hyperpolarized 129Xe gas, the first 129Xe imaging results from the human chest and the first 129Xe spectroscopy results from the human chest and head have been obtained. With polarization levels of approximately 2%, cross-sectional images of the lung gas-spaces with a voxel volume of 0.9 cm3 (signal-to-noise ratio (SNR), 28) were acquired and three dissolved-phase resonances in spectra from the chest were detected. In spectra from the head, one prominent dissolved-phase resonance, presumably from brain parenchyma, was detected. With anticipated improvements in the 129Xe polarization system, pulse sequences, RF coils, and breathing maneuvers, these results suggest the possibility for 129Xe gas-phase imaging of the lungs with a resolution approaching that of current conventional thoracic proton imaging. Moreover, the results suggest the feasibility of dissolved-phase imaging of both the chest and brain with a resolution similar to that obtained with the gas-phase images.

Adult↗