E Ebramzadeh

Publications and source records attributed to E Ebramzadeh.

9 recordsLinked to original sources

Angular deformities and forearm function.

Angular deformities were created in cadaver forearms at proximal, middle, and distal third levels of the radius and ulna separately, and at middle and distal third levels of both bones, to determine the corresponding limitations of pronation and supination. The ranges of pronation and supination were recorded using a rotational motion measurement apparatus instrumented with a 360 degrees goniometer. These experimental results were compared to data obtained from clinical and radiographic examination of 105 patients with similar residual deformities following treatment of fractures by nonsurgical means, to evaluate the accuracy of the experimental model and to determine if loss of rotational motion could be predicted based on radiographic findings. With cadaver forearms, on the average, angulation of 10 degrees of the radius or ulna in coronal or sagittal planes limited pronation and supination by less than 24 degrees, whereas angulation of 10 degrees of both the radius and the ulna limited pronation and supination by less than 18%. Comparison of experimental results with clinical findings showed that, despite the errors involved in measuring forearm deformities in patients using biplanar radiographs, the experimental results predicted the clinical loss of pronation and supination to within 17% for the fractures of the radius, and within 8% accuracy for the fractures of the ulna.

Cadaver

Demineralized bone matrix polydioxanone composite as a substitute for bone graft: a comparative study in rats.

Demineralized bone matrix (DBM) has been successfully used as a substitute for bone grafting. Autogenous bone grafts (ABG) may cause donor site morbidity and undergo significant resorption. DBM may overcome these problems but is mechanically unstable when originally placed. We explored using a slowly resorbable template, polydioxanone (PDS), in combination with DBM and compared it to ABG in a rat 9 x 9 mm cranial defect model. After both 1 and 3 months, histologically and biochemically well-formed bone was present in ABG/PDS and DBM/PDS-treated defects, but not in control defects (PDS alone). Mechanical push-out tests using a servohydraulic testing frame were conducted. Maximum load before failure of DBM/PDS increased from 65% at 1 month to 100% of that of intact skull at 3 months. In contrast, ABG/PDS was 50% as strong as DBM/PDS and not significantly stronger than PDS alone. ABG/DBM did not significantly increase in strength from 1 to 3 months. We conclude that DBM/PDS is better than ABG/PDS in treating cranial defects in the rat model, and that an absorbable osteoinductive bone substitute with superior mechanical advantage is possible without the disadvantages of ABG.

Animals

Tinel's sign and Phalen's test in carpal tunnel syndrome.

Tinel's sign and Phalen's test are two provocative tests used in the diagnosis of carpal tunnel syndrome. A review of the literature reveals a wide range of sensitivity for these tests. Analyzing the historical data and comparing these to the Tinel's sign and Phalen's test results of 100 individuals without carpal tunnel syndrome (200 wrists), we conclude that the Tinel's sign is not useful in the evaluation of patients with carpal tunnel syndrome, whereas Phalen's test, which has a greater sensitivity and specificity, can be of use.

Adolescent

Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur.

The motion of three different press-fit hip prosthesis femoral components was compared with that of a cemented stem and an Austin Moore noncemented hemiarthroplasty. Synthetic composite femurs were used as an experimental model to reduce the variations in shape and quality typical among cadaver femurs. Motion was measured under axial and rotational loading approximating a walking load. On the initial application of load, axial subsidence was as much as several millimeters for the noncemented stems. Considerable tightening occurred during the 5,000 walking cycles, such that the motion of the noncemented stems in some directions eventually was as small as that of the cemented stem, on the order of tens of microns.

Biomechanical Phenomena

Total hip replacement after failed hemiarthroplasty or mould arthroplasty. Comparison of results with those of primary replacements.

We compared the radiographic results of secondary total hip replacements, 99 following failed uncemented hemiarthroplasties and 21 following failed mould arthroplasties, with those of 825 primary cemented total hip replacements. The probability of occurrence of a number of radiological changes over time was calculated using survival analysis. The mean follow-up was 7.6 years (range one month to 20 years). The performance of the secondary total hip replacements varied with the preceding implant and was different for acetabular and femoral components. The incidence of radiological loosening was higher for femoral components implanted after failed hemiarthroplasties and for acetabular components after failed mould arthroplasties. However, the incidence of continuous radiolucent lines was lower for the acetabular components of converted hemiarthroplasties than for the primary replacements.

Arthroplasty

[Three-dimensional measurement of fracture gap motion. Biomechanical study of experimental tibial fractures with anterior clasp fixator and ring fixator].

A computer-linked magnetic motion tracker was used to monitor the six components of elastic fracture motions in cadaver tibia with simulated mid-shaft oblique fractures or segmental defects. The limbs were mounted in a servo-hydraulic load frame and stabilized with an Ilizarov frame or an AO-Unifix external fixator. A cyclic load of 150 or 300 N was applied along the long axis of the tibia. Under 150 N load, elastic displacements ranged up to 1.7 mm and elastic rotations ranged up to 0.6 degrees. Under 300 N load, elastic displacements went up to 3.6 mm and elastic rotations ranged up to 1.5 degrees. Comparison of the two fixators showed that the Ilizarov permitted up to 1.75 times more axial pistoning and up to 4 times more A-P displacement. The AO-Unifix permitted up to 4 times more varus-valgus and up to 7 times more A-P angulation. The technique developed for measuring the three-dimensional motion of fractures may have wide applications in further biomechanical and fracture healing studies.

Biomechanical Phenomena

Cup containment and orientation in cemented total hip arthroplasties.

We reviewed the radiographs of 864 Charnley and STH (Zimmer) cemented total hip arthroplasties with a mean follow-up of seven years (maximum 16 years). Survivorship analysis was used to assess the correlation between radiographic performance and the bony containment or the coronal orientation of the acetabular cup. The cup orientation and containment were interrelated; all vertically oriented cups were completely contained, whereas 25% of more horizontal cups were only partially contained. Completely contained cups had significantly lower incidences of complete cement-bone radiolucency (p = 0.02) and of wear (p = 0.09). Vertically oriented cups had a lower incidence of continuous radiolucency than neutrally oriented cups, but this was not statistically significant (p = 0.25). Our results confirm the importance of complete bony containment, and also indicate that it is better to accept vertical orientation and obtain full bony coverage than to have a more horizontal orientation with partial containment.

Alloys

Total hip arthroplasty with cement. A long-term radiographic analysis in patients who are older than fifty and younger than fifty years.

The long-term performance of a total of 712 Charnley and STH prostheses was evaluated as a function of the patient's age (older than fifty years or younger than fifty years) and of the underlying disease (osteoarthrosis, rheumatoid arthritis, or avascular necrosis). In patients who were older than fifty years, there were lower incidences of continuous cement-bone radiolucency about the acetabular component (p = 0.04), wear of the polyethylene acetabular cup (p = 0.03), and resorption of the calcar (p = 0.03). However, larger percentages of younger patients had rheumatoid arthritis or avascular necrosis. In the cohort of patients who had osteoarthrosis, the performance of the prosthesis did not differ significantly between older and younger patients; therefore we attributed the differences that were observed to the disease--that is, to rheumatoid arthritis or avascular necrosis.

Age Factors

In vivo wear of titanium-alloy hip prostheses.

We examined samples of tissue and components that had been removed during twenty revisions of total hip arthroplasties in which a titanium-alloy femoral component had been used. Minute amounts of metallic debris were detected in the tissues from two patients. The amounts of polyethylene and methylmethacrylate debris and the histological reactions in the tissues corresponded closely with those reported in earlier studies of total hip prostheses made of stainless steel or cobalt-chromium alloy.

Acrylates