PubMed Health⌕ Search

Biomedical subjects

E Euler

Publications and source records attributed to E Euler.

At least 19 recordsLinked to original sources

[Comparison of C-arm CT and standard imaging in osteosyntheses of fractured distal radius specimens].

BACKGROUND: The purpose of this study was to evaluate the value of C-arm CT imaging of the distal radius with standard patient positioning in intraoperative assessment of plate osteosynthesis. MATERIALS AND METHODS: Four complete distal radius specimens from human cadavers were fractured (type C), and internal fixation with palmar plates (stainless steel) was then carried out in each. On the basis of C-arm fluoroscopy, radiography and C-arm CT (Siremobil Iso-C3D, scans with forearm bones positioned parallel to the z-axis), 19 observers subsequently evaluated the positions of screws near the joint and any steps within the joint, after which the bones were surgically exposed and the imaging results checked against direct visual observations. RESULTS: No statistically significant differences were detected either between the modalities or between the evaluator groups. CONCLUSION: With standard patient positioning, the performance of C-arm CT was equivalent to and not better than that of current standard procedures, i.e. intraoperative fluoroscopy and postoperative radiography. Further studies should examine whether this holds true in clinical practice with representative patient collectives when titanium implants are used and/or optimized patient positioning is practised.

Cadaver↗

Massive blood transfusion and outcome in 1062 polytrauma patients: a prospective study based on the Trauma Registry of the German Trauma Society.

BACKGROUND AND OBJECTIVES: About 15% of polytrauma patients receive massive blood transfusion (MBT) defined as > or = 10 units of packed red blood cells (PRBC). In general, the prognosis of trauma patients receiving MBT is considered to be poor. The purpose of this study was to investigate the impact of MBT on the outcome of polytrauma patients. MATERIALS AND METHODS: Records of 10 997 patients in the Trauma Registry of the German Trauma Society were analysed. Transfusion data were available from 8182 severe trauma patients with a mean injury severity score of 24.5 and, of these 8182 patients, 1062 received > or = 10 units of PRBC. First, a logistic regression model for the predictors of mortality was performed. Second, incidences of organ failure and sepsis as well as survival rates were analysed. RESULTS: The highest risk for mortality was age over 55 years (odds ratios [OR] 4.7; confidence intervals [CI 95%], 3.5-6.5) followed by Glasgow Coma Scale < or = 8 (OR 4.6; 3.4-6.1), MBT > or = 20 units of PRBC (OR 3.3; 2.1-5.4), thromboplastin time < 50% (OR 3.2; 2.2-4.4) and injury severity score > or = 24 (OR 2.9; 2.1-4.1). Transfusion of 10-19 PRBC was identified as the variable with the lowest risk for mortality (OR 1.5; 1.0-2.3). Risk of organ failure, sepsis and death correlated with increasing transfusion amount. For the MBT patients, the survival rate was 56.9% (CI 95%, 53.9-59.9%) compared to 85.2% (84.4-86.0%) of non-MBT patients (P < 0.001). In the MBT group with > 30 PRBC (mean 40.6 PRBC) 39.6% survived (31.7-47.5%). CONCLUSION: Massive blood transfusion is one main prognostic factor for mortality in trauma. Although MBT is generally considered to be critical, every second trauma patient with MBT survived. A cut-off value for the number of PRBC could not be determined. Extended transfusion management even with high amounts of PRBC seems to be justified.

Adult↗

[CT-guided vertebroplasty and kyphoplasty: comparing technical success rate and complications in 101 cases].

PURPOSE: To compare the technical success and complication rates in CT-guided vertebroplasty and kyphoplasty. MATERIALS AND METHODS: From 2002 - 2005 69 patients (101 vertebrae) were treated with vertebroplasty (n = 82) or kyphoplasty (n = 19) using 4-slice MSCT with CT fluoroscopy as the sole guidance for the procedure. The underlying lesions were osteoporotic fractures in 78 vertebral bodies and 23 vertebral metastases. RESULTS: Technical success was achieved in all 101 procedures. Post-interventional CT demonstrated asymptomatic cement leakage in 51/101 vertebrae. Kyphoplasty resulted in leakage in 11/19 (57.9 %) and vertebroplasty in 40/82 (48.8 %) procedures. With p = 0.48 (Mann-Whitney Test) there was no significant difference between kyphoplasty and vertebroplasty with respect to the number of cement leakage occurrences. There was one minor complication of an L5 root irritation following radiofrequency ablation and vertebroplasty of a sarcoma metastasis which subsided without treatment after 8 weeks. There was one major complication of intraspinal cement leakage during tumor vertebroplasty causing T5 root compression and requiring laminectomy for cement removal. The overall rate of major complications requiring treatment was 0.99 %. CONCLUSION: Vertebroplasty and kyphoplasty can be safely performed using only MSCT fluoroscopy guidance. The rate of major complications is very low. There was a high rate of small asymptomatic cement leakages which may have remained undetected with conventional fluoroscopy (CF). There was no statistically significant advantage for kyphoplasty with respect to cement leakage and the technical success rate.

Adult↗

A novel surgical technique for transverse sternal bone defects using flexible intramedullary nailing.

Transverse sternal bone defects as a result of surgery or trauma remain an important clinical condition with serious sequelae. Patients sometimes complain of local pain during movement and breathing. Usually, defects are filled with prosthetic materials which remain permanently IN SITU. Small defects can be treated with autogenous bone grafts, whereas large defects are difficult to stabilize with common osteosynthetic techniques. Here, we report a new surgical technique using flexible intramedullary nailing ("Elastic Stable Intramedullary Nailing"--ESIN or "Embrochage Centro-Medullaire Elastique Stable"--ECMES) to stabilize a sternal defect after surgical removal of an osteochondral lesion. The defect was bridged by two elastic titanium nails and an autogenous corticocancellous bone graft. This new surgical technique showed a good clinical and functional outcome.

Adult↗

[Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT].

PURPOSE: To analyze a prototype mobile C-arm 3D image amplifier in the detection and classification of experimental tibial condylar fractures with multiplanar reconstructions (MPR). METHOD: Human knee specimens (n = 22) with tibial condylar fractures were examined with a prototype C-arm (ISO-C-3D, Siemens AG), plain films (CR) and spiral CT (CT). The motorized C-arm provides fluoroscopic images during a 190 degrees orbital rotation computing a 119 mm data cube. From these 3D data sets MP reconstructions were obtained. All images were evaluated by four independent readers for the detection and assessment of fracture lines. All fractures were classified according to the Müller AO classification. To confirm the results, the specimens were finally surgically dissected. RESULTS: 97 % of the tibial condylar fractures were easily seen and correctly classified according to the Müller AO classification on MP reconstruction of the ISO-C-3D. There is no significant difference between ISO-C and CT in detection and correct classification of fractures, but ISO-CD-3D is significant by better than CR. CONCLUSION: The evaluation of fractures with the ISO-C is better than with plain films alone and comparable to CT scans. The three-dimensional reconstruction of the ISO-C can provide important information which cannot be obtained from plain films. The ISO-C-3D may be useful in planning operative reconstructions and evaluating surgical results in orthopaedic surgery of the limbs.

Humans↗

[Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3 D)].

PURPOSE: Evaluation of 3D-CT imaging of the axial skeleton and different joints of the lower and upper extremities with a new dedicated CT system (ISO-C-3D) based on a mobile isocentric C-arm image amplifier. MATERIAL AND METHODS: 27 cadaveric specimes of different joints of the lower and upper extremities and of the spinal column were examined with 3D-CT imaging (ISO-C-3D). All images were evaluated by 3 radiologists for image quality using a semiquantitative score (score value 1: poor quality; score value 4: excellent quality). In addition, dose measurements and measurements of high contrast resolution were performed in comparison to conventional and low-dose spiral CT using a high contrast phantom (Catphan, Phantom Laboratories). RESULTS: Adequate image quality (mean score values 3 - 4) could be achieved with an applied dose comparable to low-dose CT in smaller joints such as wrist, elbow, ankle and knee. A remarkably inferior image quality resulted in imaging of the hip, lumbar and thoracic spine (mean score values 2 - 3) in spite of almost doubling the dose (dose increased by 85 percent). The image quality of shoulder examinations was insufficient (mean score value 1). Phantom studies showed a high-contrast resolution comparable to helical CT in the xy-axis (9 lp/cm). CONCLUSION: Preliminary results show, that image quality of C-arm-based CT-imaging (ISO-C-3D) seems to be adequate in smaller joints. ISO-C-3D images of the hip and axial skeleton show a decreased image quality, which does not seem to be sufficient for diagnosing subtle fractures.

Arm↗

[Introduction of a new mobile C-arm/CT combination equipment (ISO-C-3D). Initial results of 3-D sectional imaging].

Preclinical evaluation of a new mobile C-arm image amplifier with an option for three-dimensional computed tomography (CT) imaging (prototype Iso-C3D) with respect to high-contrast resolution and possible clinical applications. Cadaveric specimens (n = 30) of different joints of the lower and upper extremities and specimens of the spinal column were examined with the Iso-C3D and evaluated for image quality. In addition, using a high-contrast phantom (Catphan, Phantom Laboratory, Salem, N.Y., USA) and a fracture model of the femoral bone, measurements of high-contrast resolution were performed in comparison to spiral CT. With the exception of the shoulder, all joint regions including the entire spinal column could be examined. Adequate image quality could be achieved in smaller joints such as the wrist, elbow, ankle, and knee, whereas a remarkably decreased image quality was found when imaging the hip as well as the lumbar and thoracic spine. Images of the phantom study and high-contrast fracture model showed a high-contrast resolution comparable to helical CT (9 Lp/cm in xy-axis). In smaller joints, the image quality of the mobile C-arm CT imaging system (Iso-C3D) is comparable to that of helical CT. Image quality in examinations of the hip and lumbar and thoracic spine seems to be sufficient for intraoperative control studies of osteosynthesis. Problems still occur in shoulder examinations.

Arthrography↗

[3-D imaging with a mobile surgical image enhancement equipment (ISO-C-3D). Initial examples of fracture diagnosis of peripheral joints in comparison with spiral CT and conventional radiography].

To analyze a prototype mobile C-arm image amplifier (Iso-C3D) in the evaluation of different joint fractures of the upper and lower limbs using multiplanar reconstruction (MPR). Different cadaver joint specimens (n = 14) were examined with a prototype (Iso-C3D, Siemens AG, Erlangen, Germany), plain radiographs (CR), and spiral computed tomography (CT). The motorized C-arm provides fluoroscopic images during a 190 degrees orbital rotation computing a 119-mm data cube. These three-dimensional data sets yielded MPR images, which were evaluated by two readers for the detection and extent of fracture lines. Initial data show that fractures were easily depicted and correctly classified on MPR images with the Iso-C3D and that there was no difference between the Iso-C and CT in the detection of fractures. The preliminary results suggest a remarkably good detection of joint fractures with the Iso-C3D. Studies in an adequate number of patients are required to elucidate whether these promising results can also be obtained in a clinical setting.

Ankle Injuries↗

[Comparative study of the quality of C-arm based 3D imaging of the talus].

Malposition of extraosseous or intra-articular screws, e.g., in osteosyntheses of joint fractures or in the vicinity of joints, frequently remains undiscovered in intraoperative fluoroscopy and is only recognized on postoperative computed tomography (CT) scans. The aim of the study, therefore, was to assess the value of a new mobile C-arm three-dimensional imaging device in comparison with fluoroscopy, conventional radiographs, and CT scans using an extremity model. Screws were inserted ventrally in four anatomic lower leg specimens without talus fractures parallel to the longitudinal axis to simulate surgical management of fractures of the talus. The specimens supplied were examined with fluorscopy, conventional radiography, spiral CT, and the new three-dimensional imaging with the SIREMOBIL Iso-C3D. These four modalities were evaluated by ten radiologists and ten trauma surgeons and were compared regarding subjective image quality and position of the screws. The quality of information acquired with the SIREMOBIL Iso-C3D was equal to that of the CT examinations, although image quality was considered inferior to fluoroscopy, conventional radiography, and CT (p < 0.001). In contrast to the previous procedure with intraoperative fluoroscopy and subsequent postoperative X-ray control, the results obtained with the SIREMOBIL IsoC3D were superior. The SIREMOBIL Iso-C3D is useful for the intraoperative diagnosis of small joints with few artifacts producing osteosynthesis material, i.e., for recognizing the position of screws in the region of glenoid surfaces.

Bone Screws↗

[Temporary balloon occlusion as therapy of uncontrollable arterial hemorrhage in multiple trauma patients].

PURPOSE: Presentation of temporary balloon occlusion as an interventional radiological method for managing hemorrhage in multiply injured patients with uncontrollable loss of blood. METHOD: Temporary, non-selective arterial occlusion by introduction of a balloon catheter contralaterally to the source of bleeding has been performed since 1992 on 7 patients with multiple injuries, hemorrhagic shock requiring reanimation, and angiographic demonstration of an arterial hemorrhage in the supply region of the internal iliac artery with complex pelvic fracture. In each case a PTA balloon catheter was introduced transfemorally, non-selectively positioned proximal to the bleeding source, and left in place for 24-48 h under manometric control. Control angiographies were performed prior to catheter removal. RESULTS: The bleeding was stopped immediately in all 7 patients. The hemodynamic stability made transport and thus further surgical management and/or a short-term treatment in the intensive-care station possible. Control angiographies confirmed that the bleeding had stopped in all patients. CONCLUSIONS: We recommend temporary balloon occlusion as a rapid and effective method for the management of bleeding in otherwise uncontrollable traumatic hemorrhages in the supply region of the internal iliac artery.

Adult↗

Percutaneous computed tomographic-controlled ventriculostomy in severe traumatic brain injury.

OBJECTIVE: Percutaneous computed tomographic (CT)-controlled ventriculostomy (PCV) was introduced for the monitoring of intracranial pressure in patients with severe traumatic brain injury who did not require simultaneous decompressive trepanation. METHODS: PCV (n = 14) was compared with conventional burr hole ventriculostomy (n = 13) based on prospectively collected data. RESULTS: PCV proved to be a successful technique in all cases and also when a burr hole ventriculostomy was impossible previously. There were no complications. In burr hole ventriculostomy, there were one unsuccessful insertion and one catheter contamination. The main advantage of PCV over burr hole ventriculostomy was a significant (p < 0.05) reduction in the time required to perform the procedure. In ventriculostomy directly after the initial evaluation in the emergency department, the operation time was reduced from 45 +/- 11 to 22 +/- 14 minutes. The interval between cranial computed tomography and start of operation was reduced from 78 +/- 38 to 33 +/- 12 minutes, and between initial cranial computed tomography and intensive care unit admittance, from 138 +/- 37 to 73 +/- 28 minutes. For patients requiring ventriculostomy while being treated in the intensive care unit, the duration of the procedure (i.e., absence from the intensive care unit) was able to be reduced from 111 +/- 24 to 81 +/- 21 minutes. CONCLUSION: Distinct time savings are the major advantages of PCV, allowing exact catheter positioning even with very narrow ventricles.

Adolescent↗

[Acetabular and pelvic fractures in multiple trauma].

We see pelvic fractures in about 50% of all multiple trauma patients. In many cases, these pelvic fractures are complicated by complex pelvic traumata, i.e., a pelvic fracture with pelvic vessel damage, neurological, visceral or soft-tissue damage, and therefore have the character of life-threatening lesions. The incidence of complex pelvic trauma is extremely high in cases of vertical and rotation instability. Most problems come from massive bleeding as a result of presacral venous plexus laceration. This venous bleeding usually tampons its self after stabilization, e.g., with an external fixator. In about half of the cases an immediate laparotomy is performed because of remaining circulatory instability, lesions of the urinary tract, or open fractures. In these cases, stabilization of the pelvis is frequently achieved by ORIF, e.g., plating of the symphysis pubis or the SI joint. Internal stabilization of the pelvis facilitates the following treatment in the ICU, especially when prone-supine positioning is mandatory due to pulmonary indications. For this reason we avoid traction techniques in displaced acetabular fractures, and we achieve stability with a joint-bridging external fixator. Treatment of complex pelvic fracture must be integrated in the overall concept of treatment. Differentiated and situation-adapted action is necessary, depending on the particular situation, as well as the personnel and technical equipment.

Acetabulum↗

[Changes in shape of the McKee-Farrar hip endoprosthesis].

The still unsolved problem of aseptic loosening in total hip arthroplasties with identification of polyethylene wear particles as one of its major causes, has led to reintroduction of metal-to-metal articulations, as indicated by a few good clinical long-term results with all-metal McKee-Farrar arthroplasties. In this paper, data on 145 patients from a population of more than 1400, all with implanted McKee-Farrars, who underwent revision surgery for aseptic loosening, are collected and analysed for dependence of duration to brands of the implants and position of the cups. The surface of each of 55 revised implants was measured using a 3-D device. The results showed no interdependence between time of loosening, brand inclination of the cup and deviation in shape of ball and cup. Additionally, the deviations in shape were slight.

Acetabulum↗

[Pelvic fractures: epidemiology, therapy and long-term outcome. Overview of the multicenter study of the Pelvis Study Group].

Pelvic fractures are rare injuries (3-8%) when compared to fractures in other body regions. They are accompanied by high mortality (5-20%), and the survivors suffer from severe pain and pelvic-related handicaps. The German Pelvic Group (German Chapter of the AO-International & German Trauma Society) started a prospective multicenter study, including ten major trauma centers for collecting a high number of data in a short period of time (1991-1993). All pelvic injuries were documented consecutively using a special set of evaluation sheets. The study closed with 1,722 patients. A 2-year follow-up was completed for 486 patients injured in 1991 and 1992 after type B and C injuries, complex pelvic trauma, acetabulum fractures and a random 25% of A-type injuries (overall follow-up rate 73%). The follow-up included special "out-come" criteria. Of the pelvic ring injuries without significant peripelvic soft tissue involvement, 63.6% were A-type fractures, 21.0% B-type injuries and 15.5% C-type injuries. The rate of operative stabilization was 3.9% after A-type injuries, 37.3% after B-type injuries and 54.3% after C-type injuries. In isolated acetabular fractures ORIF was performed in 38.6%. The total lethality was 7.9% with a significant difference between "complex" pelvic trauma (21.3%) and patients without concomitant peripelvic injuries (7.2%). In 0.9% the pelvic injury was reported as the main cause of death. Pain at follow-up was observed in every classification group, the rate of completely "pain-free" patients being 55% after A-type, 41% after B-type and 27% after C-type fractures. Malfunction of micturia was reported by 7.6% of all patients, sexual malfunction by 11.6% of the males ("erectile dysfunction") and 2.2% of the female ("dysparneuria"). Scaled by the recently developed "outcome score", the radiological result showed anatomical healing after 90.8% of the B-type and 74.6% of the C-type injuries. On the other hand, the clinical result was rated as good or excellent in only 70% of the B-type and 54% of the C-type injuries. Although progress in indications and treatment techniques has shown improved radiological results after unstable pelvic ring injuries when compared to earlier studies, the clinical result still remains unsatisfactory. Further analyses and studies must be conducted to identify the prognostic factors for the late sequelae. Whether it is possible influence these factors by additional surgical intervention cannot be answered at present.

Acetabulum↗

[Stabilizing procedures in tumor-induced bone defects of the pelvis and extremities].

With malignant tumors of the skeleton the same therapeutic limb-saving guidelines must apply for the proximal sections of the locomotor system--the shoulder and pelvic girdles--as for the limbs themselves, especially since amputation here can hardly be surpassed by other resectional interventions with respect to operative risk, disfigurement and functional loss. The possibilities of surgical therapy for tumorous invasion of the pelvic girdle and the extremities are considered in some detail.

Adolescent↗

[Diagnosis, classification and indications for surgical treatment of pelvic ring fractures].

In cases of high-energy trauma, it is well known that there is a high incidence of pelvic fractures. The mechanism of injury, inspection and physical examination of the victim at the accident site direct attention to a pelvic fracture. In most cases, the first radiological examination (A.P. X-ray of the pelvis, oblique view of the obturator and oblique view of the ilium) shows the extent of the bony lesion. The diagnosis and therapy of lesions of the urinary tract, of intra-abdominal organs and blood vessels are vitally important. For the definitive operation of unstable pelvic ring fractures, additional diagnostic means, i.e., CT scans to distinguish posterior instability, can be necessary. Osteosynthesis can only be successful in the pelvis if one has a biochmechanical understanding of the physiological flux of force from the neck of the femur via the acetabular fossa to the sacroiliac joint. The sacroiliac ligaments have a particularly important support function. For assessing stability and classifying the traumatic patterns, it is helpful to use Pennal's classification, which takes the direction of the action of force into account. Three basic forms can be distinguished: anteroposterior compression, lateral compression and vertical avulsion. Depending on the extent of the traumatic pattern, one can distinguish three subtypes: type 1 is treated conservatively while types 2 and 3 require surgical treatment. The biochmechanics, traumatic patterns, diagnostics and treatment techniques applied are described clearly and with good illustrations.

Biomechanical Phenomena↗

[Scapula fractures--classification and differential therapy].

The classification of fractures of the scapula (type A: body and process fractures; type B: neck fractures; type C: glenoid fractures) is shown, and the indications for conservative and operative treatment are described, as are the surgical approaches and operative techniques. In our hospital, 93 patients with 153 fractures of the scapula type A, B or C (ratio 1.6:1) were treated. This ratio was 1.7:1 in patients treated by operation. The indication for operation was usually glenoid fractures with accessory process fractures.

Adolescent↗