PubMed Health⌕ Search

Biomedical subjects

E F Gordon

Publications and source records attributed to E F Gordon.

7 recordsLinked to original sources

Impact of ion cloud densities on the measurement of relative ion abundances in Fourier transform ion cyclotron resonance mass spectrometry: experimental observations of coulombically induced cyclotron radius perturbations and ion cloud dephasing rates.

Fundamental research into the quantitative properties of Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) has yielded interesting observations, especially in terms of factors affecting the accuracy of relative ion abundances. However, most of the previous discussions have focused on theoretical systems, or systems of limited scope. In this paper, we document ion motion attributes of a 30 spectra (six samples, five replicates each) system previously established as linear over two orders of magnitude. Observed behaviors include the perturbation of one charged species (cyclosporin A, CsA) of low ion density to a cyclotron orbit of greater radius than that of an almost identical, but slightly mass-separated species (CsG) with a higher ion density. This radial perturbation is attributed to the coulombic repulsion between the two ion clouds as they interact during the excitation process, as previously proposed by Uechi and Dunbar. Magnitudes of the perturbation were confirmed by making cyclotron radii determinations utilizing the ratio of the third-to-first harmonics for the charged species of interest. It was found that these radial differences can account for as much as a 55% signal bias in favor of CsA for a single sample and a >20% positive bias in the slope of the regressed data set. A second behavior noted that also contributes to the potential inaccuracy of relative ion abundance measurements is the difference in signal decay rates for CsA and CsG. Damping constants and initial time domain signal amplitudes were evaluated using segmented Fourier transforms. Discrepancies in decay rates were not expected from two species that have essentially identical collisional cross-sections. However, it has been observed that the faster decay rates are observed by the species of lower ion cloud density. We have attributed this differential signal decay phenomenon to the rates of loss of phase coherence for the two ion clouds. Previously, others have reported that less dense ion clouds are more susceptible to shearing and other disruptive forces during the course of their excited cyclotron motion. Our experimental evidence supports that it is the loss of cloud coherence that accounts for the signal loss over time, with the less dense cloud de-phasing more quickly. As the ion populations of the two investigated species near equivalence, so do their time constants.

Cyclosporine↗

Hydropathic influences on the quantification of equine heart cytochrome c using relative ion abundance measurements by electrospray ionization fourier transform ion cyclotron resonance mass spectrometry.

The number of publications documenting the utility of electrospray ionization (ESI) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) for the analysis of biological molecules has increased in geometric proportion spanning diverse areas of research. Currently, we are investigating the capabilities of ESI-FTICR to quantify relative molecular ion abundances of biopolymers, an area which has not been explored rigorously. We present here the results of an investigation of a two-component system utilizing equine heart cytochrome c (EH) as the analyte and bovine heart cytochrome c (BH) as a constant concentration internal standard. As these compounds are relatively large ( approximately 12 kDa), they will become multiply charged during the electrospray process. Using appropriate solution and instrument conditions, the 7(+) and 8(+) charge states were enhanced for both cytochrome c species. We report that using the average of the ion abundances for the two charge states observed for each species, the linear curve (intensity ratio vs concentration ratio) had a dynamic range of 0.045-2.348 microM (1.7 orders of magnitude). Linear least-squares regression analysis (LLSRA) of these averaged ion abundances (i.e. [(EH + 7H(+))(7+)/(BH + 7H(+))(7+) + (EH + 8H(+))(8+)/(BH + 8H(+))(8+)]/2) yielded the equation y = 1.005x + 0.027. The slope of the line with its calculated precision, reported as one standard deviation, is 1.005 +/- 0.0150, which is statistically ideal (i.e. equal to unity). However, LLSRA of the ion abundances of the two individual charge states were significantly different (i.e. the slope of the (EH + 7H(+))(7+)/(BH + 7H(+))(7+) peak intensity ratio vs molar ratio data was 0.885 +/- 0.0183 and the slope of the (EH + 8H(+))(8+)/(BH + 8H(+))(8+) data was 1.125 +/- 0.0308). We attribute this difference to the variation in primary amino acid sequence for the two cytochrome c species. Both have 104 amino acids, but there are three residue substitutions between EH and BH; one of the substitutions confers an additional basic site to EH. While this extra basic residue may imply an additional charging site, the low charge states observed under the solution conditions employed indicate that most (>66%) basic sites are not protonated. However, the extra basic site also renders EH slightly more hydrophilic. These results present significant considerations when choosing internal standards for the quantification of large proteins by ESI-FTICR-MS and demonstrate that relative molecular ion signals in FTICR can be used to quantify macromolecular species in the nanomolar regime.

Amino Acid Sequence↗

Zinc deficiency and behavior: a development perspective.

Zinc deficiency was induced in 35 and 300 day-old male Holtzman rats. Group ZDA was fed ad lib a diet deficient in zinc (1 ppm), ZSP controls were pair-fed a diet supplemented with zinc (50 ppm) and ZSA controls were fed ad lib a diet supplemented with zinc (50 ppm). Physical status and six open-field behaviors were evaluated. Food intake, body weight and plasma zinc concentrations were significantly reduced in both age groups. Expanded use of the open-field revealed significantly lower latencies to explore the novel environment and significantly lower ambulation scores in the young and older zinc deficient rats. Older rats spent significantly less time grooming than their controls. Rearing was significantly less in young zinc deficient rats and "kangaroo-like" posture was evident. Young rats made deficient during critical periods of growth and development, were at greater risk for most parameters tested, compared to the older deficient rats. These rats do demonstrate, however, that feeding low-zinc diets to older, fully developed animals results in significant physical and behavioral impairment.

Age Factors↗

Intracranial hemorrhage in a neonate following prenatal cocaine exposure.

A term infant who had a positive urine drug screen for cocaine is reported. There was ultrasonographic evidence of an intracranial hemorrhage. A small area of low echogenicity in the left caudothalamic groove documented at 96 hours of age was resolved on repeat ultrasonography at 16 days of age. This neonate was born by repeat cesarean section and growth was appropriate for gestational age. The findings indicate the importance of considering cerebrovascular events in neonates exposed to cocaine in utero.

Brain↗