Determination of lysine in pharmaceutical samples containing endogenous ammonium ions by using a lysine oxidase biosensor based on an all-solid-state potentiometric ammonium electrode.

A new potentiometric method is proposed to determine lysine in pharmaceutical samples. This method is based on a lysine biosensor consisting of a chemically immobilized lysine oxidase membrane attached to an all-solid-state ammonium electrode. Lysine is degraded in the sensor to release ammonium, which is detected by means of the ammonium electrode. The presence of endogenous ammonium in the samples interferes with these determinations, since the response measured corresponds to the sum of the ammonium generated enzymatically and that present in the sample. This is a general drawback for all biosensors based on the detection of ammonium. Study of samples containing both lysine and ammonium showed that concentration ranges exist in which a near-logarithmic relationship between potentials measured and lysine concentrations is found. Therefore, within these ranges, lysine can be determined by using the standard addition method, with the subsequent data treatment involving an iterative linearization procedure. Results obtained with the proposed potentiometric method are consistent with those given by the standard method for amino acid analysis.

Amino Acid Oxidoreductases↗

Amperometric determination of lysine using a lysine oxidase biosensor based on rigid-conducting composites.

In this study, amperometric biosensors based on rigid conducting composites are developed for the determination of lysine. These lysine biosensors consist of chemically immobilized lysine oxidase membranes attached to either graphite-methacrylate or peroxidase-modified graphite-methacrylate electrodes. The enzymatic degradation of lysine releases hydrogen peroxide, which is the basis of the amperometric detection. The direct oxidation of hydrogen peroxide is monitored at +1000 mV with a graphite-methacrylate electrode, while with the peroxidase-modified electrode reductive detection is performed. In addition, for the peroxidase-modified biocomposite electrode, both direct electron transfer and hydroquinone-mediated detection are studied. For the lysine biosensor based on the hydroquinone-mediated peroxidase biocomposite, the linear range is up to 1.6 x 10(-4) M, the sensitivity 11300 microA/M, the repeatability 1.8%, the detection limit 8.2 x 10(-7) M and the response time t95% is 42 s. The proposed biosensors are used to determine lysine in pharmaceutical samples. Results are consistent with those obtained with the standard method.

Biosensing Techniques↗

Flow injection immunoanalysis based on a magnetoimmunosensor system.

A new immunosensor integrated to a flow system has been developed. It is based on magnetic immunoparticles immobilized on a solid-state transducer using a magnetic field. The described technique renews the immunoparticles reproducibly for each analysis allowing a good measurement precision. The developed experimental approach permits the implementation of an automated immunoassay that is quick (analytical cycle < 30 min) and sensitive in the micromolar concentration range. The system was applied to the determination of rabbit immunoglobulin G as an analyte model.

Animals↗

Development of electrochemical immunosensing systems with renewable surfaces.

The repeated use of immunochemically modified solid phases in electrochemical immunosensor analysis is the driving interest of this work. Two new strategies have been developed. One of these strategies is aimed at the development of a manual methodology. It comprises the construction of amperometric immunosensors based on rigid biocomposites. These biocomposites are formed by a conducting polymer composite matrix that acts as a reservoir of an immobilized immunologic material. The surface of the biocomposite can be renewed by a simple polishing procedure. The second strategy involves the design of an automatic methodology. It features an immunochemical analytical system using flow injection techniques. The potentiometric detection uses a solid phase formed by immunologic reagents immobilized in magnetic particles. These particles are fixed to the sensor with the use of a magnetic field. The renewal of the reactive surface is achieved by the release and activation of the restraining magnetic field and the manipulation of the flow. The analytical properties of these immunosensors were evaluated measuring RIgG using a competitive technique and measuring GaRIgG with a sandwich methodology. The labelling enzymes of the immunoconjugates were peroxidase in amperometric measurements and urease in potentiometric measurements.

Animals↗

Development of a biparametric bioanalyser for creatinine and urea. Validation of the determination of biochemical parameters associated with hemodialysis.

The construction and evaluation of an automated urea and creatinine biparametric biosystem using flow injection analysis (FIA) are described. The biosystem uses enzyme reactions that hydrolyse urea and creatinine producing ammonium ions. The enzymes used were creatinine deiminase and urease, which are immobilized covalently in flow reactors. The reactor with creatinine deiminase has the enzyme immobilized on controlled-pore glass beads, whereas urease is immobilized on a nylon open tubular reactor. Detection is realised with a flow-through ammonium ion-selective electrode with an inner solid-state contact (graphite-epoxy composite). Ammonium ions are separated from alkali ion interferents through a gas-diffusion cell. The bioanalyser is fully automated using software and electronics developed ex profeso in our laboratories. The analyser was validated off-line by measuring urea and creatinine from discrete effluent samples from hemodialysis equipment. Results agreed with concurrent analyses realised using hospital laboratory methods. There were no significant differences between the two sets of results at the 95% confidence level. Finally, the biparametric bioanalyser was validated on-line by measuring creatinine and urea levels in artificial kidney effluents. These measurements were useful in the determination of key biochemical parameters of clinical interest such as the mass of urea and creatinine extracted from the patient as well as the initial concentration of creatinine and urea in blood plasma. When the results of the bioanalyser were compared with those yielded by the usual methods, they showed no significant differences at the 95% confidence level when determining the mass of the analytes extracted by the hemodialyser or when determining the urea concentration in blood plasma. However, when measuring the creatinine concentration in blood plasma using the developed bioanalyser, significant differences appeared.

Biological Assay↗