[Cardiovascular MRT--replacement of diagnostic invasive coronary angiography?].

With cardiovascular magnetic resonance imaging (CMR), the necessity of invasive coronary angiography may be increasingly avoided. CMR provides information about the anatomy of the coronaries themselves (e.g. anomalies, aneurysm), functional information on myocardial blood flow (dobutamine-stress-MR, perfusion measurement) and detailed information on cell-mediated alterations (e.g. fibrosis, necrosis). However, visualization of distal coronary vessels and the small side branches is not yet adequate, so that complete replacement of invasive coronary angiography by CMR is not possible.

Coronary Angiography↗

[Cardiac resynchronization therapy for heart failure - from experimental pacing to evidence-based therapy].

Within the last decade, cardiac resynchronization therapy (CRT) has become an evidence-based cornerstone for a subset of patients with chronic heart failure. For those, who suffer from ischemic or non-ischemic cardiomyopathies at NYHA III or IV, have sinus rhythm, a left bundle branch block and a left ventricular ejection fraction below 35%, CRT has evolved as an important treatment option with promising results. Numerous studies have shown that in these patients pacemaker-mediated correction of intra- and interventicular conduction disturbances can improve not only clinical symptoms, exercise tolerance and the frequency of hospitalizations, but even more important the overall mortality. These clinical results are due to several functional aspects. In the failing heart characteristic intra- and interventricular alterations in electrical conduction result in mechanical asynchrony that leads to an abnormal contraction of the left ventricle with delayed activation of the lateral wall, a paradoxical septal movement, a reduced diastolic filling and a mitral regurgitation due to dyssynchrony of papillary muscle activation. It is conceivable that these functional changes have fatal consequences for the failing heart. AV-optimized left- or biventricular stimulation by modern pacemakers can correct the pathological dyssynchrony, thereby improving cardiac function and clinical outcome in these patients. Although tremendous progress in cardiac resynchronization therapy has been made during the last decade, a couple of questions still need to be resolved. Critical issues are the identification of patients, who will predictably benefit from CRT, the value of CRT-pacemakers versus CRT-ICDs, and the usefullness of CRT in patients with atrial fibrillation.

Cardiac Pacing, Artificial↗

[Networking and integrated disease management. Advantages and disadvantages from the medical point of view].

At the moment the terms "networking", "cost reduction" and "integrated disease management" are frequently discussed in all branches of the German health care system. Unfortunately there are different interpretations of these terms. "Integrated disease management" in the meaning of communication between clinical and outpatient health care has al ready existed for years now. Traditional ways of communication lead to information loss. Losing information is a reason for low cost effectiveness and a prolonged healing process directly harming the patient. A computer network may prevent information loss and may in crease the performance of data transfer. Different sides have al ready started networking, and it is now necessary to bundle the interests. This necessity has been recognized by the German legislative. To lead this project to success it is important to know and to fulfil some medical criteria. Defining and describing these conditions is the topic of this paper. Our special intent is to show that digital technique is necessary to improve cooperation among physicians.

Computer Communication Networks↗

Primary fibrosarcoma of the liver infiltrating the right atrium of the heart.

A rare case of a primary fibrosarcoma of the liver infiltrating the right heart is described in a 72-year-old woman. The patient presented with a history of progressive dyspnea and ascites and her general condition was poor. Preoperative cardiac magnetic resonance (CMR) imaging revealed a large mass, which originated from the liver and had infiltrated the right atrium via the inferior vena cava. The patient underwent tumor resection yet died shortly afterwards. Histologically the mass was classified as a fibrosarcoma with positive immunostaining for vimentin. We report the CMR imaging characteristics in this uncommon case. Preoperative CMR proved to be useful for clinical decision making and the planning of surgery.

Aged↗

MR coronary artery imaging with 3D motion adapted gating (MAG) in comparison to a standard prospective navigator technique.

Magnetic resonance coronary angiography (MRCA) has been proven to be feasible for imaging of the proximal and medial portions of the three main coronary arteries. Free breathing techniques allow for high resolution imaging but prolong scan time. This could potentially be shortened by improving the efficiency, robustness and accuracy of the navigator gating algorithm. Aim of this study was to determine the feasibility, efficiency, and image quality of a new motion compensation algorithm (3D-MAG) for coronary artery imaging with navigator techniques. In 21 patients the coronaries were imaged in plane with a 3D k-space segmented gradient echo sequence. A T2 preparation prepulse was used for suppression of myocardial signal, during free breathing and a navigator technique with using real time slice following and a gating window of 5 mm was applied to suppress breathing motion artefacts. Imaging was performed with standard gating and compared to 3D-MAG. Image quality was visually compared, contrast-to-noise and signal-to-noise ratio were calculated, the length of visualized coronary arteries was measured and scan duration and scan efficiency were calculated. Standard navigator imaging was feasible in 19 of 21 (90.5%) patients 3D-MAG in 21/21 (100%). Scan efficiency and duration was significantly improved with 3D-MAG (p < .05) without change in image quality. 3D-MAG is superior to conventional navigator correction algorithms. It improves feasibility and scan efficiency without reduction of image quality. This approach should be routinely used for MR coronary artery imaging with navigator techniques.

Algorithms↗

Determinants of myocardial response in CMR perfusion imaging using Gd-BOPTA (Multihance).

PURPOSE: Different centers and vendors use different sequences and contrast agent application schemes for MR myocardial perfusion imaging. The purpose of this study was to evaluate the role of different sequences, dosages, and injection speeds of contrast media for semiquantitative MR-perfusion assessment. METHODS: In a pilot study with 58 consecutive patients three of the most commonly used sequences for MR myocardial perfusion imaging (T1-GrE, GrE-EPI or SSFP) were compared to each other in terms of peak myocardial enhancement and image quality. For the main part of the study dynamic first pass MR perfusion imaging (Philips Intera CV, Best, Tthe Netherlands) was performed in 24 patients using the most favorable sequence from the pilot study (SSFP) after peripheral i.v. administration of Gd-BOPTA during adenosine stress. Two doses (0.05 mmol/kg bw and 0.025 mmol/kg bw) and four different injection speeds (8, 4, 3, 2 ml/s) were used. Signal intensity time curves were determined in the LV and myocardial segments supplied by normal coronary arteries and correlation between LV and myocardial upslope as well as peak enhancement were noted. RESULTS: The SSFP-sequence showed a higher peak enhancement when using 0.05 mmol/kg bw of Gd-BOPTA and a superior image quality for both dosage regimen compared with the other sequences and was consequently applied for the main study. A significant correlation was found between the upslopes in the LV and the myocardium (r square = 0.85, p < 0.001). However, LV and myocardial upslopes were largely independent of the dosage. Myocardial upslope was significantly slower at an injection rate of 2 ml/s compared to 3 and 4 ml/s. Higher Gd-doses led to significantly higher enhancement (p < 0.001). CONCLUSION: In healthy myocardial segments, the myocardial upslope is mainly determined from the LV upslope. Both myocardial enhancement and upslope are largely independent from the injection rate of a contrast agent bolus as long as the injection speed is not below 3 ml/s. Myocardial enhancement, however, is dose dependent. Thus, a simple correction for LV upslope allows to normalize a wide variety of input parameters. Differences of myocardial upslope or peak signal intensity after correction should be mainly dependent on blood flow.

Contrast Media↗

Comparison of dobutamine stress magnetic resonance, adenosine stress magnetic resonance, and adenosine stress magnetic resonance perfusion.

BACKGROUND: Dobutamine stress MR (DSMR) is highly accurate for the detection of inducible wall motion abnormalities (IWMAs). Adenosine has a more favorable safety profile and is well established for the assessment of myocardial perfusion. We evaluated the diagnostic value of IWMAs during dobutamine and adenosine stress MR and adenosine MR perfusion compared with invasive coronary angiography. METHODS AND RESULTS: Seventy-nine consecutive patients (suspected or known coronary disease, no history of prior myocardial infarction) scheduled for cardiac catheterization underwent cardiac MR (1.5 T). After 4 minutes of adenosine infusion (140 microg x kg(-1) x min(-1) for 6 minutes), wall motion was assessed (steady-state free precession), and subsequently perfusion scans (3-slice turbo field echo-echo planar imaging; 0.05 mmol/kg Gd-BOPTA) were performed. After a 15-minute break, rest perfusion was imaged, followed by standard DSMR/atropine stress MR. Wall motion was classified as pathological if > or =1 segment showed IWMAs. The transmural extent of inducible perfusion deficits (<25%, 25% to 50%, 51% to 75%, and >75%) was used to grade segmental perfusion. Quantitative coronary angiography was performed with significant stenosis defined as >50% diameter stenosis. Fifty-three patients (67%) had coronary artery stenoses >50%; sensitivity and specificity for detection by dobutamine and adenosine stress and adenosine perfusion were 89% and 80%, 40% and 96%, and 91% and 62%, respectively. Adenosine IWMAs were seen only in segments with >75% transmural perfusion deficit. CONCLUSIONS: DSMR is superior to adenosine stress for the induction of IWMAs in patients with significant coronary artery disease. Visual assessment of adenosine stress perfusion is sensitive with a low specificity, whereas adenosine stress MR wall motion is highly specific because it identifies only patients with high-grade perfusion deficits. Thus, DSMR is the method of choice for current state-of-the-art treatment regimens to detect ischemia in patients with suspected or known coronary artery disease but no history of prior myocardial infarction.

Adenosine↗

Calculation of individual cardiovascular risk in a primary prevention setting shows a high number of patients with a high risk score.

On occasion of the annual convention of the European Society of Cardiology, general awareness was used to stage an event to inform the public about cardiovascular risk and cardiovascular disease. After the measurement of blood pressure, HDL and total cholesterol and after answering questions on smoking and medication visitors received a printout showing their individual calculated cardiovascular event rate over the next ten years. For the calculation of the expected event rate, the algorithm of the Adult Treatment Panel III was used. Of the 43,500 visitors 1513 were screened, 651 male, 862 female. Of those screened in this primary prevention setting 143 male (22.07%) and 9 female (1.02%) had an expected cardiovascular event rate of 20% or more over the next ten years requiring immediate action according to the current guidelines. The calculated risk scores are considerably lower than would be expected in a representative sample from the population. This indicates that patients with a high cardiovascular risk possibly do not take part in unstructured primary screening events.

Cardiovascular Diseases↗

Non-invasive estimation of left ventricular end-diastolic pressure by pulmonary venous flow deceleration time.

AIMS: The scope of this study was to assess the potential value of pulmonary venous flow diastolic deceleration time to predict end-diastolic pressure and stratify patients with regard to elevation of left ventricular end-diastolic pressures. METHODS AND RESULTS: In 174 consecutive patients, pulmonary venous flow diastolic deceleration time was determined and compared with left ventricular end-diastolic pressures measured invasively. The sample was randomly divided into two subgroups of equal size for modelling of prediction and independent testing of the model. Predicted left ventricular end-diastolic pressures calculated from pulmonary venous flow diastolic deceleration time (left ventricular end-diastolic pressures=-10.87 + 5261/pulmonary venous flow diastolic deceleration time) agreed well with measured left ventricular end-diastolic pressures (mean difference: -1.3 +/- 3.4 mmHg). The correlation of left ventricular end-diastolic pressures with pulmonary venous flow diastolic deceleration time is fair (r=0.73989). A value of pulmonary venous flow diastolic deceleration time <220 ms is suggestive of elevated left ventricular end-diastolic pressures and should be monitored. A value of pulmonary venous flow diastolic deceleration time <190 ms predicts elevated left ventricular end-diastolic pressures. A value of pulmonary venous flow diastolic deceleration time <165 ms predicts severely elevated left ventricular end-diastolic pressures. With 190 ms as a cut-off value for elevated and 165 ms for severely elevated left ventricular end-diastolic pressures, cross-table analysis classifies all patients with normal left ventricular end-diastolic pressures correctly. No patient with severe elevation (<18 mmHg) of left ventricular end-diastolic pressures is classified as normal (chi2=102, P<0.0001). CONCLUSION: Pulmonary venous flow diastolic deceleration time is an appropriate non-invasive measurement to stratify patients with respect to elevation of left ventricular end-diastolic pressures.

Adult↗

Improved functional cardiac MR imaging using the intravascular contrast agent CLARISCAN.

PURPOSE: Using segmented k-space turbo gradient echo MR techniques (TGE) contrast between blood and myocardium is often reduced in long axis views due to reduced in plane spin-refreshment, particularly in patients with low ejection fraction. The application of an intravascular contrast agent (CA) may improve endocardial border delineation. MATERIALS AND METHODS: In 15 patients cardiac cine loops in two long axis and two short axis views were acquired during breath hold using a TGE sequence without and with increasing doses of CA (0.75, 2.0, 5.0 mg Fe/kg). Two independent observers evaluated left ventricular function (LVEF, modified Simpson's rule) and assigned a visual score (range: 0 = 'not visualized' to 6 = 'excellent visualization') for endocardial border delineation. Signal- and contrast-to-noise ratios (SNR; CNR) were determined. RESULTS: Endocardial border delineation score for TGE was 1.7 +/- 0.6 and 3.9 +/- 0.6**, 4.4 +/- 0.5**, 4.6 +/- 0.4** for 0.75, 2.0, 5.0 mg Fe/kg of CA, respectively (**p < 0.01 vs. TGE). SNR of blood increased significantly with any dose of CA with a mild drop of myocardial SNR resulting in a significant increase of CNR blood/myocardium. The maximum effect with 2.0 mg Fe/kg was a >2-fold CNR increase. Inter- and intraobserver variability assessed according to the method of Bland-Altmann was reduced at 2.0 mg Fe/kg for determination of LVEF and reached statistical significance for LVEF <50%. CONCLUSION: Intravascular CA increased CNR between blood and myocardium by a factor >2 and significantly improved the determination of cardiac volumes. The benefit in accuracy was most for patients with left ventricular ejection fraction <50%.

Aged↗

Effect of resynchronization therapy stimulation site on the systolic function of heart failure patients.

BACKGROUND: Cardiac resynchronization therapy (CRT) improves systolic function in heart failure patients with ventricular conduction delay by stimulating the left ventricle (LV) or both ventricles (biventricular, BV). Optimal LV site selection is of major clinical interest for CRT device implantation; however, the dependence of hemodynamics on LV stimulation site has not been established. Thus, the objective of this study was to compare the hemodynamic response to CRT for 2 LV coronary vein sites: the free wall and anterior wall. Methods and Results- A total of 30 patients (mean NYHA class, 2.7; mean QRS interval, 152 ms; mean PR interval, 194 ms) enrolled in the PATH-CHF-II trial were studied. CRT was administered with LV and BV stimulation in VDD mode at 4 AV delays. LV stimulation was at the lateral free wall or anterior wall, whereas right ventricular stimulation was fixed near the apex. LV+dP/dt(max) and aortic pulse pressure changes from baseline during CRT were compared for LV sites. Free wall sites with LV and BV stimulation yielded significantly larger LV+dP/dt(max) (14% versus 6%, P<0.001 for LV; 12% versus 5%, P<0.001 for BV) and pulse pressure (8% versus 4%, P<0.001 for LV; 9% versus 5%, P<0.001 for BV) compared with anterior sites. In one third of patients, CRT at free wall sites increased LV+dP/dt(max), whereas it decreased at anterior sites over most AV delays. CONCLUSION: CRT with LV free wall stimulation produced significantly better LV systolic performance compared with anterior stimulation. Further studies are warranted to prove the clinical superiority of the LV free wall as a site for long-term CRT.

Aged↗