Objective evaluation of changes in left ventricular and atrial volumes during parabolic flight using real-time three-dimensional echocardiography.

We tested the feasibility of real-time three-dimensional (3D) echocardiographic (RT3DE) imaging to measure left heart volumes at different gravity during parabolic flight and studied the effects of lower body negative pressure (LBNP) as a countermeasure. Weightlessness-related changes in cardiac function have been previously studied during spaceflights using both 2D and 3D echocardiography. Several technical factors, such as inability to provide real-time analysis and the need for laborious endocardial definition, have limited its usefulness. RT3DE imaging overcomes these limitations by acquiring real-time pyramidal data sets encompassing the entire ventricle. RT3DE data sets were obtained (Philips 7500, X3) during breath hold in 16 unmedicated normal subjects in upright standing position at different gravity phases during parabolic flight (normogravity, 1 Gz; hypergravity, 1.8 Gz; microgravity, 0 Gz), with LBNP applied (-50 mmHg) at 0 Gz in selected parabolas. RT3DE imaging during parabolic flight was feasible in 14 of 16 subjects. Data were analyzed (Tomtec) to quantify left ventricular (LV) and atrial (LA) volumes at end diastole and end systole, which significantly decreased at 1.8 Gz and increased at 0 Gz. While ejection fraction did not change with gravity, stroke volume was reduced by 16% at 1.8 Gz and increased by 20% at 0 Gz, but it was not significantly different from 1 Gz values with LBNP. RT3DE during parabolic flight is feasible and provides the basis for accurate quantification of LV and LA volume changes with gravity. As LBNP counteracted the increase of LV and LA volumes caused by changes in venous return, it may be effectively used for preventing cardiac dilatation during 0 Gz.

Adult↗

Tracking of left ventricular long axis from real-time three-dimensional echocardiography using optical flow techniques.

Two-dimensional echocardiography (2DE) is routinely used in clinical practice to measure left ventricular (LV) mass, dimensions, and function. The reliability of these measurements is highly dependent on the ability to obtain nonforeshortened long axis (LA) images of the left ventricle from transthoracic apical acoustic windows. Real time three-dimensional echocardiography (RT3DE) is a novel imaging technique that allows the acquisition of dynamic pyramidal data structures encompassing the entire ventricle and could potentially overcome the effects of LA foreshortening. Accordingly, the aim of this paper was to develop a nearly automated method based on optical flow techniques for the measurement of the left ventricular (LV) LA throughout the cardiac cycle from RT3DE data. The LV LA measurements obtained with the automated technique has been compared with LA measurements derived from manual selection of the LA from a volumetric display of RT3DE data. High correlation (r = .99, SEE = 1.8%, y = .94x + 5.3), no significant bias (-0.18 mm), and narrow limits of agreement (SD: 1.91 mm) were found. The comparison between the LA length derived from 2DE and RT3DE data showed significant underestimation of the 2DE based measurements. In conclusion, this study proves that RT3DE data overcome the effects of foreshortening and indicates that the method we propose allows fast and accurate quantification of LA length throughout the cardiac cycle.

Algorithms↗

Improved quantification of left ventricular mass based on endocardial and epicardial surface detection with real time three dimensional echocardiography.

OBJECTIVE: To develop a technique for volumetric analysis of real time three dimensional echocardiography (RT3DE) data aimed at quantifying left ventricular (LV) mass and to validate the technique against magnetic resonance (MR) assumed as the reference standard. DESIGN: RT3DE, which has recently become widely available, provides dynamic pyramidal data structures that encompass the entire heart and allows four dimensional assessment of cardiac anatomy and function. However, analysis techniques for the quantification of LV mass from RT3DE data are fundamentally two dimensional, rely on geometric modelling, and do not fully exploit the volumetric information contained in RT3DE datasets. Twenty one patients underwent two dimensional echocardiography (2DE), RT3DE, and cardiac MR. LV mass was measured from 2DE and MR images by conventional techniques. RT3DE data were analysed to semiautomatically detect endocardial and epicardial LV surfaces by the level set approach. From the detected surfaces, LV mass was computed directly in the three dimensional space as voxel counts. RESULTS: RT3DE measurement was feasible in 19 of 21 patients and resulted in higher correlation with MR (r = 0.96) than did 2DE (r = 0.79). RT3DE measurements also had a significantly smaller bias (-2.1 g) and tighter limits of agreement (2SD = +/-23 g) with MR than did the 2DE values (bias (2SD) -34.9 (50) g). Additionally, interobserver variability of RT3DE (12.5%) was significantly lower than that of 2DE (24.1%). CONCLUSIONS: Direct three dimensional model independent LV mass measurement from RT3DE images is feasible in the clinical setting and provides fast and accurate assessment of LV mass, superior to the two dimensional analysis techniques.

Echocardiography, Three-Dimensional↗

Quantification of left ventricular modification in weightlessness conditions from the spatio-temporal analysis of 2D echocardiographic images.

Two-dimensional echocardiography (2DE) performed during flights with a parabolic trajectory to simulate weightlessness provides a unique means to study left ventricular (LV) modifications to prevent post-flight orthostatic intolerance in astronauts. However, conventional analysis of 2DE is based on manual tracings and depends on experience. Accordingly, the aim was objectively to quantify, from 2DE images, the LV modifications related to different gravity levels, by applying a semi-automated level-set border detection technique. The algorithm validation was performed by the comparison of manual tracing results, obtained by two independent observers with 20 images, with the semi-automated measurements. To quantify LV modifications, three consecutive cardiac cycles were analysed for each gravity phase (1 Gz, 1.8 Gz, 0 Gz). The level-set procedure was applied frame-by-frame to detect the LV endocardial contours and obtain LV area against time curves, from which end-diastolic (EDA) and end-systolic (ESA) areas were computed and averaged to compensate for respiratory variations. Linear regression (y = 0.91x + 1.47, r = 0.99, SEE:0.80cm2) and Bland-Altman analysis (bias = -0.58 cm2, 95% limits of agreement= +/- 2.14cm2) showed excellent correlation between the semi-automatic and manually traced values. Inter-observer variability was 5.4%, and the inter-technique variability was 4.1%. Modifications in LV dimensions during the parabola were found: compared with 1 Gz values, EDA and ESA were significantly reduced at 1.8 Gz by 8.8 +/- 5.5% and 12.1 +/- 10.1%, respectively, whereas, during 0 Gz, EDA and ESA increased by 13.3 +/- 7.3% and 11.6 +/- 5.1%, respectively, owing to abrupt changes in venous return. The proposed method resulted in fast and reliable estimations of LV dimensions, whose changes caused by different gravity conditions were objectively quantified.

Adult↗

Changes in Doppler mitral inflow patterns during parabolic flight.

Aim of the study was to evaluate by transthoracic Doppler the alterations in mitral inflow velocity pattern caused by acute changes in loading conditions occurring during parabolic flights. Each parabola included normogravity (1 Gz, 1 min), mild hypergravity (1.8 Gz, 20 sec), microgravity (0 Gz, 24 sec) and mild hypergravity (1.8 Gz, 20 sec) phases. Pulsed-Doppler images were digitally acquired in 11 unmedicated subjects (46 +/- 5 years), in standing upright position and supine resting. Doppler profiles were semi-automatically traced and inflow parameters extracted and averaged onto three consecutive beats. Only in standing position, significant alterations during microgravity (p<0.05) were noted in several parameters.

Adult↗

Feasibility of real-time 3D echocardiography in weightlessness during parabolic flight.

Aim of the study was to test the feasibility of transthoracic real-time 3D (Philips) echocardiography (RT3D) during parabolic flight, to allow direct measurement of heart chambers volumes modifications during the parabola. One RT3D dataset corresponding to one cardiac cycle was acquired at each gravity phase (1 Gz, 1.8 Gz, 0 Gz, 1.8 Gz) during breath-hold in 8 unmedicated normal subjects (41 +/- 8 years old) in standing upright position. Preliminary results, obtained by semi-automatically tracing left ventricular (LV) and left atrial (LA) endocardial contours in multiple views (Tomtec), showed a significant (p<0.05) reduction, compared to 1 Gz, of LV and LA volumes with 1.8 Gz, and a significant increase with 0 Gz. Further analysis will focus on the right heart.

Adult↗

Analysis of cardiac left-ventricular volume based on time warping averaging.

The cardiac left-ventricular (LV) volume signal, obtained by acoustic quantification, is affected by noise and respiratory modulation, resulting in a large beat-to-beat variability that affects the computation of LV function indices. A new method is proposed to improve the evaluation of LV indices by applying a signal averaging technique based on dynamic time warping to consecutive LV volume waveforms. Volume signals obtained from ten normal young (NY) subjects (mean age +/- SD: 25+/-5 years) were used to evaluate the performance of this algorithm. To evaluate its clinical utility, the effects of ageing and pharmacologically induced changes on LV function were assessed by studying, respectively, ten normal (N) adult subjects (age 64+/-8 years) and ten patients with dilated cardiomyopathy during a control and low-dose dobutamine (10 microg kg(-1) min(-1)) study. Indices of LV function were highly consistent, with a variability of less than 8%, even when only 16 beats were averaged, independently of their selection inside the whole recording. When compared with beat-to-beat measures, the averaging of 16 beats significantly reduced (by more than 50%) the interbeat variability of all indexes. Expected alterations in both diastolic and systolic function were evidenced both with ageing (peak filling atrial contraction and ejection rates: from 275+/-77 mls(-1), 76+/-30 ml s(-1) 230+/-70 mls(-1), respectively, in NY, to 160+/-33 mls(-1), 125+/-39 mls(-1), 163+/-54 mls(-1) in N) and with dobutamine (peak filling and ejection rates from 160+/-72 mls(-1) and 183+/-86 mls(-1) respectively, in control, to 253+/-75 mls(-1) and 251+/-105 mls(-1) with dobutamine). Signal averaging with time warping allows fast and improved assessment of LV function.

Aging↗

Changes in left ventricular size during parabolic flights by two-dimensional echocardiography and level set method.

This study aims to evaluate changes on cardiac chambers size, induced by gravitational stresses. During parabolic flight, seven subjects underwent 2-D transthoracic echocardiography at three different gravity phases (1 Gz, 1.8 Gz, and 0 Gz). LV endocardial borders were detected applying a semi-automatic segmentation procedure based on level set methods. LV cavity area was computed frame-by-frame for a whole cardiac cycle during each gravity phase. Expected modifications in LV area with different gravity were found: at 1.8 Gz, end-diastolic (ED) and end-systolic (ES) areas were significantly (p<0.05) reduced of 10.7 +/- 5.4% and 21.6 +/- 11.1% respectively, compared to 1 Gz values, while they were increased of 11.2 +/- 5.4% and 11.1 +/- 6% during 0 Gz. Fractional area change was augmented of 20.9 +/- 29.1% at 1.8 Gz, while it remained unchanged at 0 Gz, compared with 1 Gz values. Furthermore, LV filling due to atrial contraction was increased at 0 Gz of 39 +/- 35.6%.

Adult↗

Time-variant spectral analysis of heart rate variability during parabolic flight with and without LBNP.

Modifications of autonomic activity during parabolic flight were studied by a time-variant model able to estimate low (LF, 0.04-0.14 Hz) and high (HF, 0.14-0.35 Hz) frequency spectral components on a beat-to-beat basis. Ten subjects were studied with and without lower body negative pressure (LBNP). ECG and Gz load were digitized (500 Hz) and RR interval variability series extracted. Beat-to-beat mean RR, variance, LF and HF power were obtained. One-way ANOVA (p<0.01) was used to compare values obtained during starting 1Gz (I), first 1.8Gz (II), 0Gz (III), second 1.8Gz (IV), ending 1Gz (V). Without LBNP, total and LF power increased during 0Gz to 1.69 +/- 1.41 and 2.87 +/- 4.66 respectively (mean +/- SD, normalized by phase I value). With LBNP, their change during 0Gz (1.38 +/- 1.37 and 1.54 +/- l.04 respectively) reached significance only with phase II and phase V. Phase I HF power was higher than in the other phases, both without and with LBNP.

Journal Article↗

RR-arterial pressure variability relationships.

Methodological aspects of a causal black-box model of heart period/arterial pressure interaction, arterial pressure closed-loop regulation and respiration effects on both heart period and arterial pressure are revisited in the "time" (more exactly heart beat count) domain. Parameters are estimated from experimental data (model identification) by means of multiple linear regressions of actual samples over the past ones. The elements composing either heart period or systolic arterial pressure variability are visualised as beat-by-beat series. Indexes describing the signal interactions, the loop properties and the spectral components of the variability series are consequently summarised. In 17 normal young volunteers, the analysis was carried out during active standing, rest, mild clinostatic pedalling exercise at 10%, 20%, and 30% of the maximum effort, and recovery. A negative effect of heart period changes on systolic arterial pressure of - 13.3 mm Hg/s was found at rest. This effect, though augmented by exercise, appeared insignificant in explaining arterial pressure variability. Arterial baroreflex was assessed by alphaart index which had a value of 5.18 mm Hg/ms at rest, 3.78 mm Hg/ms during active standing, and decreased progressively with exercise down to 0.55 mmHg/ms. The pressure regulation loop displayed a tendency to amplify disturbances at low frequency (around 0.1 Hz) 5.94 times at rest, augmented to 8.88 times during standing, 7.55 at 30% exercise. The first parameter of the pressure auto-regression was slightly higher than 1 at rest and even more augmented during standing, thus, indicating a tendency of arterial pressure perturbations to persist from one beat to the next. These mechanisms appear important in the genesis of low-frequency pressure waves. Nonetheless, the trace of different sources was evident in the regression residuals. Noticeably, during exercise it explained 10.16% of total heart period variability compared to 12.49% related to the low-frequency oscillations of closed-loops. The origin of high-frequency waves synchronous with respiration appeared miscellaneous as well. Arterial pressure appeared negligibly affected by heart period changes. Conversely, a limited effect of arterial pressure waves was found on heart period superimposed to a large effect of cardiopulmonary reflexes directly modulating the sinus node. In conclusion, both high-frequency and low-frequency waves are composite phenomena and a multi-channel analysis comparing heart period and arterial pressure variability yields a variety of figures assessing cardiovascular regulation and cardiorespiratory coupling.

Adult↗

Combined assessment of myocardial perfusion and regional left ventricular function by analysis of contrast-enhanced power modulation images.

BACKGROUND: Echocardiographic contrast media have been used to assess myocardial perfusion and to enhance endocardial definition for improved assessment of left ventricular (LV) function. These methodologies, however, have been qualitative or have required extensive offline image analysis. Power modulation is a recently developed imaging technique that provides selective enhancement of microbubble-generated reflections. Our goal was to test the feasibility of using power modulation for combined quantitative assessment of myocardial perfusion and regional LV function in an animal model of acute ischemia. METHODS AND RESULTS: Coronary balloon occlusions were performed in 18 anesthetized pigs. Transthoracic power modulation images (Agilent 5500) were obtained during continuous intravenous infusion of the contrast agent Definity (DuPont) at baseline and during brief coronary occlusion and reperfusion and were analyzed with custom software. At each phase, myocardial perfusion was assessed by calculation, in 6 myocardial regions of interest, of mean pixel intensity and the rate of contrast replenishment after high-power ultrasound impulses. LV function was assessed by calculation of regional fractional area change from semiautomatically detected endocardial borders. All ischemic episodes caused detectable and reversible changes in perfusion and function. Perfusion defects, validated with fluorescent microspheres, were visualized in real time and confirmed by a significant decrease in pixel intensity in the left anterior descending coronary artery territory after balloon inflation and reduced rate of contrast replenishment. Fractional area change decreased significantly in ischemic segments and was restored with reperfusion. CONCLUSIONS: Power modulation allows simultaneous online assessment of myocardial perfusion and regional LV wall motion, which may improve the echocardiographic diagnosis of myocardial ischemia.

Animals↗

Evaluation of respiratory influences on left ventricular function parameters extracted from echocardiographic acoustic quantification.

This study was designed to assess, using the echocardiographic acoustic quantification technique, the influence of respiration on left ventricular (LV) function and its modifications connected with the ageing process, quantifying in a non-invasive way the respiratory contribution to the LV volume variability. An automated algorithm is applied to extract the beat-to-beat measurements of LV function parameters from the LV volume signal, obtained from recordings lasting a few minutes. Mean values, amount of variability and spectral content were studied in a population of 17 normal young (mean age 25 +/- 1 years) and 12 normal old (mean age 64 +/- 2 years) subjects. Mean values of the beat-to-beat measurements of LV function parameters were able to point out alterations connected with the ageing process in peak filling rate, peak atrial filling rate and peak ejection rate. Spectral analysis, applied to the extracted variability series, displayed a predominance of the high-frequency (HF) component corresponding to respiration in all LV function parameters; moreover, age related changes of HF variability were observed in peak ejection rate. The HF power spectrum component of beat to beat series extracted from the LV signal can provide a non-invasive assessment of the fluctuations in ventricular parameters associated with respiration.

Adult↗