Assessment of calibration methods for estimating bone mineral densities in trauma patients with quantitative CT: an anthropomorphic phantom study.

RATIONALE AND OBJECTIVES: Osteoporosis may contribute to the increased morbidity and mortality of elderly persons involved in motor vehicle accidents. Such patients commonly undergo whole-body computed tomographic (CT) studies that may be analyzed with quantitative CT. Various quantitative CT calibration techniques were investigated for use with patients who have suffered trauma, who are typically scanned on a backboard. MATERIALS AND METHODS: Lumbar simulator phantoms were used to simulate small and large patients. Vertebral spongiosa inserts with a wide range of bone and fat compositions were placed in the phantoms, and their bone mineral densities (BMDs) were measured by using calibration lines derived from the CT numbers of a calibration standard. Four calibration techniques were tested. In three the lumbar simulator and the calibration standard were scanned simultaneously, with the standard placed beneath the backboard (method 1), on top of the backboard adjacent to the lumbar simulator (method 2), or on top of the abdomen region of the lumbar simulator (method 3). The fourth technique employed a single calibration line derived from a separate scan of the calibration standard beneath the small lumbar simulator without the backboard, with correction for patient body size. RESULTS: The best overall results were obtained with the single calibration line method. The root mean square errors of the BMD values were 2.9-18.4, 2.5-7.5, 2.5-14.9, and 0.3-2.8 mg/cm3 for methods 1, 2, 3, and 4, respectively (ranges represent variations in the errors of the measured BMDs of the inserts due to changes in scanner table height and lumbar simulator phantom size). CONCLUSION: The single calibration line method is an accurate means of measuring BMD in trauma patients.

Bone Density↗

Phototimer setup for CR imaging.

A study was performed to investigate the feasibility of using the standard deviation (sigma) of the pixel values in a computed radiography (CR) image and a measure of the median incident exposure on the imaging plate (IP) as parameters for setting up phototimers in a CR system. Slabs of Lucite 4-, 6-, and 8-in.-thick were imaged with a CR system at 70, 90, and 125 kVp at various mA s values both with grid and without grid. Incident IP exposures were measured with an ionization chamber. Images were analyzed on a workstation. The sigma's in the "flat field" images were found to be approximately related to the mean incident exposure E by the relationship: sigma is proportional to E(-1/2), indicating the quantum-noise-limited operation of the system. Derived relationships between the reading sensitivity of the (IP) reader (S number) and sigma can be used to obtain images with a specific noise level. At our institution, where a 400 speed screen-film system is used for general radiography and 200 speed for chest radiography, radiologists generally find CR image quality acceptable when sigma < or = 11 (S< or =400) for general radiography (50-90 kVp), and sigma < or =8 (S< or =200) for chest radiography (125 kVp). However, factors other than the amount of x-ray quanta that form the useful image, such as the image processing mode and the amount of collimation, may affect both the sensitivity value and the image quality.

Humans↗