Relation between amiodarone and desethylamiodarone plasma concentrations and ventricular defibrillation energy requirements.

The main finding of this prospective, controlled study is that amiodarone and desethylamiodarone plasma concentrations < 1 mg/L are associated with a 23% increase in the acute defibrillation energy requirement and with a 31% increase in the requirement for a subcutaneous patch or array. The defibrillation energy requirement does not correlate with the plasma concentrations of amiodarone, desethylamiodarone, amiodarone plus desethylamiodarone, or with the duration or daily dosage of amiodarone therapy.

Aged↗

A randomized comparison of fixed power and temperature monitoring during slow pathway ablation in patients with atrioventricular nodal reentrant tachycardia.

Temperature monitoring may be helpful for ablation of accessory pathways, however its role in ablation of atrioventricular nodal reentrant tachycardia (AVNRT) using the slow pathway approach is unclear. Therefore, the purpose of this study was to prospectively compare slow pathway ablation for AVNRT using fixed power or temperature monitoring. The study included 120 patients undergoing ablation for AVNRT. Patients were randomly assigned to receive either fixed power at 32 watts, or to temperature monitoring with a target temperature of 60 degrees C. The primary success rate was 72% in the fixed power group and 95% in the temperature monitoring group (p = 0.001). The ablation procedure duration (35 +/- 29 min vs 35 +/- 30 min; p = 0.9), fluoroscopic time (32 +/- 17 vs 35 +/- 19 min; p = 0.4), mean number of applications (10.2 +/- 8.1 vs 8.4 +/- 7.9; p = 0.2), and coagulum formation per application (0.2% vs 0.5%; p = 0.6) were statistically similar in the fixed power and temperature monitoring groups, respectively. The mean temperature (47.3 +/- 4.8 degrees C vs 48.6 +/- 3.8 degrees C; p < 0.01), and the temperature associated with junctional ectopy (48.2 +/- 3.8 degrees C vs 49.3 +/- 3.6 degrees C, p < 0.01) were less for the fixed power than the temperature monitoring group. In the temperature monitoring group, only 31% of applications achieved an electrode temperature of 60 degrees C. During follow up of 6.6 +/- 3.6 months there were two recurrences in the fixed power group and one in the temperature monitoring group (p = 1.0). In summary, power titration directed by temperature monitoring was associated with an improved primary procedural success rate. Applications of energy were associated with a temperature of approximately 50 degrees C with both techniques, suggesting that there is a low efficiency of heating in the posterior septum.

Adult↗

Rise in chronic defibrillation energy requirements necessitating implantable defibrillator lead system revision.

The chronic defibrillation energy requirement (DER) is believed to remain clinically stable in patients with defibrillators. Six patients (two with an epicardial and four with a nonthoracotomy system) were identified with a rise in their chronic DER, which eliminated a 10-J safety margin, thus necessitating a defibrillator lead system revision. The mean increase in DER was 14.7 +/- 4 J and was discovered at a mean of 16.0 +/- 18 months (range 2-41) following implantation. Management included placement of a defibrillator with a biphasic waveform, placement of an additional defibrillation electrode, or both. At 2 months following revision of the defibrillation system, a 10-J DER safety margin was present in each patient. In some patients, there is a progressive increase in the chronic DER with elimination of a 10-J safety margin necessitating revision of the defibrillation system. Routine reevaluation of the chronic DER, therefore, is necessary to identify these patients.

Aged↗

Accuracy of the unipolar electrogram for identification of the site of origin of ventricular activation.

INTRODUCTION: The purpose of this study was to determine the accuracy of the unipolar electrogram for identifying the earliest site of ventricular activation. The earliest site of ventricular activation may be identified with the unipolar electrogram by the absence of an R wave. However, the accuracy of this technique is unknown. METHODS AND RESULTS: A single ventricular premature complex was induced mechanically at the tip of an electrode catheter to simulate a ventricular premature depolarization site of origin. Unipolar electrograms were recorded from the right ventricular septum at the tip electrode and at 2, 5, 8, and 11 mm from the electrode tip in 20 patients. No R waves were detected at the ventricular premature depolarization site of origin. R waves were detected in 4 of 20 patients (20%) at 2 mm from the tip electrode and 7 of 20 patients (35%) at 5, 8, and 11 mm from the tip electrode. An R wave was not observed at distances < or = 11 mm from the site of tachycardia origin in 13 of 20 patients (65%). CONCLUSIONS: While an R wave in the unipolar electrogram can be seen as close as 2 mm from the site of impulse origin, the absence of an R wave as an indicator of the site of impulse origin in the right ventricle is highly inaccurate. Therefore, the absence of an R wave in the unipolar electrogram is unlikely to be an adequate guide for identification of an effective target site for ablation of right ventricular tachycardia.

Adult↗

Effect of an irregular ventricular rhythm on cardiac output.

Impairment of cardiac function in atrial fibrillation has been attributed to loss of atrial contraction and to a rapid ventricular rate. The results of this study suggest that irregularity of the ventricular rhythm, independent of the ventricular rate, may also contribute to impairment of cardiac function during atrial fibrillation.

Atrial Fibrillation↗

Effect of coupling interval and pacing cycle length on morphology of paced ventricular complexes. Implications for pace mapping.

BACKGROUND: Ventricular pace mapping is performed by comparing the QRS morphology of ventricular paced complexes to that of a template arrhythmia, either a premature ventricular depolarization or a QRS complex during ventricular tachycardia. The objective of this study was to evaluate the effect of coupling interval and pacing cycle length on QRS morphology. METHODS AND RESULTS: The study population consisted of 20 patients (mean age, 38 +/- 16 years) undergoing a clinically indicated electrophysiology procedure. In the first 10 patients, the effect of coupling interval on the morphology of single paced ventricular complexes was evaluated visually and by signal processing techniques. Visually apparent differences in QRS morphology occurred in a mean of 4/12 electrocardiographic leads with a change in coupling interval of > or = 100 ms. In the next 10 patients, the QRS complex morphology during ventricular overdrive pacing at cycle lengths of 600 and 300 ms was found to differ significantly in a mean of 4/12 leads. The QRS morphology during overdrive pacing differed significantly from that of a single paced complex whenever the pacing cycle length differed from the coupling interval of the single paced complex by > 80 ms. CONCLUSIONS: The morphology of single paced QRS complexes may vary, depending on coupling interval, and the QRS morphology during overdrive pacing is affected by the pacing cycle length. During ventricular pace mapping, the coupling interval or cycle length of the template arrhythmia should be matched during pacing. If not, rate-dependent changes in QRS morphology that are independent of the pacing site may confound the results of pace mapping.

Adult↗

Effect of atrial fibrillation on atrial refractoriness in humans.

BACKGROUND: The acute effect of atrial fibrillation (AF) on the atrial effective refractory period (ERP) in humans is unknown. METHODS AND RESULTS: In 20 patients without structural heart disease, the atrial ERP was measured before and after pacing-induced AF at drive cycle lengths of 350 and 500 ms. Immediately after spontaneous AF conversion, the post-AF ERP was measured. The pre-AF ERPs at 350 and 500 ms were 206 +/- 23 and 216 +/- 17 ms, respectively. The time to spontaneous conversion of AF was 7.3 +/- 1.9 minutes. The first post-AF ERPs at drive cycle lengths of 350 and 500 ms were 175 +/- 30 ms (P < .0001 versus pre-AF) and 191 +/- 30 ms (P < .0001 versus pre-AF), respectively. The post-AF ERP returned to the pre-AF ERP value after a mean of 8.4 +/- 0.3 minutes. In 15 patients, during the determination of the post-AF ERP, secondary episodes of AF lasting 1 +/- 1.5 minutes were reinduced 6 +/- 3 times per patient. There was a significant inverse logarithmic relationship between the time to reinduction of AF and the duration of secondary episodes of AF (P < .0001, r = 5). CONCLUSIONS: In humans, several minutes of induced AF is sufficient to shorten the ERP for up to approximately 8 minutes. The temporal recovery of the ERP is reflected in progressively shorter episodes of reinduced AF. These data imply that AF transiently shortens the atrial wavelength and suggest a mechanism by which AF may perpetuate itself.

Adult↗

Ventricular rate during atrial fibrillation before and after slow-pathway ablation. Effects of autonomic blockade and beta-adrenergic stimulation.

BACKGROUND: Radiofrequency catheter modification of AV conduction can be used to control the ventricular rate during atrial fibrillation both in the baseline state and during exercise. Slow-pathway ablation has been suggested to be the mechanism for this response. The purpose of this study was to determine the effect of slow-pathway ablation on the ventricular rate in atrial fibrillation during autonomic blockade and sympathetic stimulation in patients with AV nodal reentrant tachycardia (AVNRT). METHODS AND RESULTS: Thirty-five patients undergoing slow-pathway radiofrequency ablation for AVNRT were assigned to autonomic blockade (0.2 mg/kg propranolol and 0.04 mg/kg atropine; n = 14) or isoproterenol (2 micrograms/min; n = 21). Atrial fibrillation was induced before and after slow-pathway radiofrequency ablation. During autonomic blockade, the mean ventricular cycle length (448 +/- 34 versus 525 +/- 103 ms, P < .01) and maximum ventricular cycle length (640 +/- 105 versus 798 +/- 226 ms, P = .04) were prolonged after ablation, whereas the minimum ventricular cycle length did not change significantly (361 +/- 42 versus 403 +/- 83 ms, P = .05). During isoproterenol infusion, the mean ventricular cycle length (375 +/- 52 versus 390 +/- 61 ms, P = .2), maximum ventricular cycle length (520 +/- 88 versus 537 +/- 106 ms, P = .3), and minimum ventricular cycle length (307 +/- 59 versus 298 +/- 33 ms, P = .4) did not change significantly after slow-pathway ablation. CONCLUSION: Slow-pathway ablation slows the ventricular rate during atrial fibrillation under conditions of autonomic blockade but not during sympathetic stimulation. Therefore, slow-pathway ablation alone cannot account for the clinical results obtained with radiofrequency modification of AV conduction in patients with atrial fibrillation.

Adult↗

Response of type I atrial fibrillation to atrial pacing in humans.

BACKGROUND: High-density mapping studies of atrial fibrillation (AF) have suggested the presence of an excitable gap. The purpose of this study was to assess the local and left atrial response to pacing at the high right atrium during type I AF in humans. METHODS AND RESULTS: Pacing was performed at the high right atrium during type I AF in 24 patients in the electrophysiology laboratory. The response to pacing was assessed at cycle lengths 10, 20, 30, 40, and 50 ms less than the mean baseline atrial cycle length. Digitized tracings of the baseline tachycardia and the response to pacing were recorded from the high right atrium and from the distal coronary sinus. Computer analysis of these signals was used to calculate a left atrial electrogram density before, during, and after pacing. Two hundred eight-eight segments of AF with a duration of 3.9 +/- 0.5 seconds (mean +/- SD) were analyzed. Local capture of the right atrium during AF was demonstrated for at least one pacing cycle length in each patient. The left atrial electrogram density was significantly greater than baseline at each pacing cycle length that resulted in local capture, except when pacing at 50 ms less than the mean AF cycle length. There was no significant change in the baseline left atrial electrogram density compared with baseline when pacing did not result in local capture of AF. CONCLUSIONS: Local right atrial capture is often possible by pacing during type I AF and consistently influences the left atrial electrograms recorded in the coronary sinus. These results confirm the presence of excitable tissue in the right and left atria in type I AF.

Adult↗

Evaluation and extraction of the Accufix atrial J lead.

The Accufix (Telectronics Pacing Systems, Englewood, Colo.) atrial active fixation pacemaker lead has a preformed J stiff retention wire that can fracture and erode through the atrium. We screened 85 patients with digital fluoroscopy and detected 18 (21%) lead fractures. Fourteen (16%) leads were successfully extracted by percutaneous techniques. The mean time for extraction and placement of a new atrial lead was 109 +/- 53 min, and a lead > 1 year old but not in the presence of a fracture was associated with a significantly longer extraction time. There were two extraction complications. One patient had a fever following the extraction, and one patient had a focal sensory deficit 1 week after the extraction probably caused by a paradoxical embolus. Standard percutaneous extraction tools can be used for successful and safe removal of a fractured Accufix lead.

Aged↗

Oral antibiotic treatment of right-sided staphylococcal endocarditis in injection drug users: prospective randomized comparison with parenteral therapy.

PURPOSE: To compare the efficacy and safety of inpatient oral antibiotic treatment (oral) versus standard parenteral antibiotic treatment (intravenous) for right-sided staphylococcal endocarditis in injection drug users. PATIENTS AND METHODS: In a prospective, randomized, non-blinded trial, febrile injection drug users were assigned to begin oral or intravenous (IV) treatment on admission, before blood culture results were available. Oral therapy consisted of ciprofloxacin and rifampin. Parenteral therapy was oxacillin or vancomycin, plus gentamicin for the first 5 days. Antibiotic dosing was adjusted for renal dysfunction. Administration of other antibacterial drugs was not permitted during the treatment or follow-up periods. Bacteremic subjects having right-sided staphylococcal endocarditis received 28 days of inpatient therapy with the assigned antibiotics. Test-of-cure blood cultures were obtained during inpatient observation 6 and 7 days after the completion of antibiotic therapy, and again at outpatient follow-up 1 month later. Criteria for treatment failure and for drug toxicity were prospectively defined. RESULTS: Of 573 injection drug users who were hospitalized because of a febrile illness and suspected right-sided staphylococcal endocarditis, 93 subjects (16.2%) had two or more sets of blood cultures positive for staphylococci; 85 of these bacteremic subjects (14.8%) satisfied diagnostic criteria for at least possible right-sided staphylococcal endocarditis (no other source of bacteremia was apparent) and entered the trial. Forty-four (oral, 19; IV, 25) of these 85 subjects completed inpatient treatment and evaluation including test-of-cure blood cultures. There were four treatment failures (oral, 1 [5.2%]; IV, 3 [12.0%]; not significant, Fisher's exact test). Drug toxicity was significantly more common in the parenterally treated group (oral, 3%; IV, 62%; P < 0.0001), consisting largely of oxacillin-associated increases in liver enzymes. CONCLUSIONS: For selected patients with right-sided staphylococcal endocarditis, oral ciprofloxacin plus rifampin is effective and is associated with less drug toxicity than is intravenous therapy.

Administration, Oral↗

2:1 atrioventricular block during atrioventricular node reentrant tachycardia.

OBJECTIVES: The purpose of this study was to determine the incidence and to clarify the mechanism of 2:1 atrioventricular (AV) block during AV node reentrant tachycardia induced in the electrophysiology laboratory. BACKGROUND: In patients with 2:1 AV block during AV node reentrant tachycardia, the absence of a His bundle potential in the blocked beats has been considered evidence of intranodal, lower common pathway block. METHODS: In consecutive patients with AV node reentrant tachycardia, the incidence of 2:1 AV block and the response to atropine and a single ventricular extrastimulus was observed. RESULTS: Persistent 2:1 AV block occurred in 13 of 139 patients with AV node reentrant tachycardia. A His bundle deflection was present in the blocked beats in eight patients and absent in five. Patients with 2:1 AV block had a shorter tachycardia cycle length than did patients without such block (mean +/- SD 312 +/- 32 vs. 353 +/- 55 ms, p < 0.01). Atropine did not alter the 2:1 block in any patient. In every patient, a single ventricular extrastimulus introduced during the tachycardia converted the 2:1 block to 1:1 conduction. CONCLUSIONS: The incidence of induced 2:1 AV block during AV node reentrant tachycardia is approximately 10%. The lack of a response to atropine and the consistent conversion of 2:1 block to 1:1 conduction by a ventricular extrastimulus indicate that, regardless of the presence or absence of a His bundle potential in blocked beats, 2:1 block during AV node reentrant tachycardia is due to functional infranodal block.

Adult↗

Temperature and impedance monitoring during slow pathway ablation in patients with AV nodal reentrant tachycardia.

INTRODUCTION: Successful radiofrequency ablation of an accessory pathway has been demonstrated to be associated with an electrode-tissue interface temperature of approximately 60 degrees C or an impedance change of -5 to -10 omega. However, the temperature and impedance changes associated with ablation of AV nodal reentrant tachycardia (AVNRT) using the slow pathway approach have not been reported. Therefore, the purpose of this study was to define the temperature and impedance changes achieved during ablation of AVNRT: METHODS AND RESULTS: The study included 35 consecutive patients with AVNRT undergoing radiofrequency ablation of the slow pathway with a fixed power output of 32 W, and using a catheter with a thermistor bead embedded in the distal 4-mm electrode. The procedure was successful in each patient. The steady-state electrode-tissue interface temperature during successful applications of energy was 48.5 +/- 3.3 degrees C (range 42 degrees to 56 degrees C), and the steady-state temperature during ineffective applications was 46.8 degrees +/- 5.5 degrees C (P = 0.03). The mean impedance change during all applications of energy was -1.4 +/- 2.8 omega, and did not differ significantly during effective and ineffective applications. Coagulum formation resulted during five applications (2.7%) in two patients (5.7%). There were no recurrences during 114 +/- 21 days of follow-up. CONCLUSIONS: Successful ablation of AVNRT using fixed power output is achieved at an electrode-tissue interface temperature of approximately 48 degrees C and is associated with a drop in impedance of 1 to 2 omega. These findings suggest that slow pathway ablation requires less heating at the electrode-tissue interface than does accessory pathway or AV junction ablation.

Adult↗

The mechanisms responsible for lack of reproducible induction of atrioventricular nodal reentrant tachycardia.

INTRODUCTION: AV nodal reentrant tachycardia (AVNRT) is not always reproducibly inducible. The purpose of this study was to determine the mechanisms responsible for the lack of reproducible induction of AVNRT. METHODS AND RESULTS: The induction of AVNRT was assessed with atrial burst pacing, and with atrial and ventricular programmed stimulation, each with one and two extrastimuli, in 103 patients with AVNRT. The stimulation protocol was repeated 10 times in the baseline state, during isoproterenol infusion, and after atropine administration, or until AVNRT was induced in 7 of 10 attempts. The mechanisms responsible for < 7 of 10 inductions were classified as: (1) the inability to achieve critical AH prolongation; (2) fast pathway block; and (3) slow pathway block. The induction endpoint was achieved in 90 patients: 55 in the baseline state, 34 during isoproterenol infusion, and 1 after atropine. The mechanism of noninducibility in the baseline state (n = 48) was the inability to achieve a critical AH interval in 20%, fast pathway block in 49%, and slow pathway block in 31% (P = 0.02). During isoproterenol administration (n = 14) and after atropine administration (n = 13), the three mechanisms were equally responsible for nonreproducible induction of AVNRT. CONCLUSIONS: The induction of AVNRT is poorly reproducible in approximately 10% of patients. In the baseline state, the most common reason for the inability to reproducibly induce AVNRT is fast pathway block. In the presence of isoproterenol or atropine, each of the three mechanisms was equally responsible for noninducibility of AVNRT.

Adrenergic beta-Agonists↗

Comparison of early and late complications in patients undergoing coronary artery bypass graft surgery with and without concomitant placement of an implantable cardioverter defibrillator.

Previous studies have reported a significant morbidity and mortality associated with coronary artery bypass graft (CABG) surgery in conjunction with the placement of an implantable cardioverter defibrillator (ICD) with an epicardial lead system. In the absence of a control group, how significantly the component of concomitant placement of the ICD system contributes to these untoward outcomes remains unknown. The purpose of this study was to assess the short- and long-term complications in patients undergoing CABG surgery in conjunction with the placement of an ICD with epicardial leads and to compare these complications with those of patients who had only CABG surgery (control group). The study group (group A) consisted of 56 patients who underwent CABG surgery and placement of an ICD pulse generator with epicardial leads. A control group (group B) consisted of 56 patients who underwent CABG surgery only during the same time period. The two groups were matched for age, sex distribution, left ventricular function, surgical approach, number of bypass grafts per patient, bypass pump time, and length of follow-up period. The early mortality for group A was 7.1% versus 1.8% for group B (p > 0.05). The incidence of early morbidity (congestive heart failure, infection, supraventricular and ventricular arrhythmias) for groups A and B was similar (26.8% vs 25.0%, p > 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Electrocardiographic response during dobutamine stress echocardiography.

Studies assessing dobutamine stress (DS) echocardiography (echo) have included 12-lead electrocardiograms (ECG) in their protocol. We retrospectively reviewed the records of 76 patients who were referred for DS echo and coronary angiography to assess the incremental diagnostic value of DS ECG beyond the results of the echocardiographic images of the DS echo. The prevalence of coronary artery disease was 86%. Baseline ST-segment abnormalities prohibited assessment of ischemic ST-segment changes in 35 (46%) patients. For the detection of a > or = 50% stenosis on coronary angiography, DS echo alone had a sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of 92%, 73%, 95%, 62%, and 89%, respectively. The DS ECG alone had a sensitivity, specificity, PPV, NPV, and accuracy of 38%, 45%, 81%, 11%, and 39%, respectively. Combined results of the DS echo and the DS ECG slightly increased sensitivity, but with a marked reduction in specificity, PPV, NPV, and accuracy. We conclude that (1) DS ECG is interpretable for ischemic ST-segment changes in about 50% of patients referred for DS echo; (2) DS ECG is a poor predictor of coronary artery disease; and (3) DS ECG response only slightly increases the sensitivity of the echo findings of a DS echo study. Because the incremental diagnostic value of the DS ECG response is poor, elimination of the 12-lead DS ECG is unlikely to diminish the diagnostic value of the DS echo and may result in a substantial cost savings.

Coronary Angiography↗

Incidence of implantable defibrillator discharges after coronary revascularization in survivors of ischemic sudden cardiac death.

Coronary revascularization has been suggested as sole therapy for secondary prevention of sudden cardiac arrest associated with ischemia. The use of implantable defibrillators (ICD) in combination with coronary revascularization for this patient population is unclear. Among 412 consecutive patients receiving an ICD, 23 (6%) were identified as sudden cardiac arrest survivors who were noninducible with programmed stimulation and had unstable angina or ischemia on a functional study; they underwent successful coronary revascularization. During a follow-up of 34 +/- 18 months, 10 (43%) of the 23 patients received ICD shocks (8 +/- 8 per patient, range 1 to 22 shocks), and nine of the 10 patients had syncope/presyncope associated with at least one ICD discharge. Patients with ICD discharges were compared with those without ICD discharges, and no clinical characteristics were statistically different between the two groups. In conclusion, revascularization alone may be inadequate therapy for survivors of sudden cardiac arrest associated with ischemia who are noninducible with programmed stimulation, and clinical variables cannot predict which patients are likely to have recurrent malignant ventricular arrhythmias.

Aged↗