PubMed Health⌕ Search

Biomedical subjects

E Garcia-Cimbrelo

Publications and source records attributed to E Garcia-Cimbrelo.

12 recordsLinked to original sources

Long-term results of uncemented acetabular cups with an ACS polyethylene liner. a 14-16-year follow-up study.

We assessed the clinical and radiographic results of 40 porous-coated acetabular cups with an Acetabular Cup System polyethylene liner over a minimum 14-year follow-up. Femoral head penetration was estimated using a software package. Fifteen cups were revised, 11 due to polyethylene liner rupture. All cups but two were radiographically stable, and 11 hips showed acetabular osteolysis. The overall femoral head penetration rate in hips without liner fracture with reference to the early penetration point was 0.1188+/-0.070 mm per year. Polyethylene liner fractures were associated with higher early femoral head penetration (P<0.0001) and a vertical cup position (P=0.0016). The 14-year survival without cup revision for any reason was 63.9%, 71.8% with no ACS polyethylene liner fracture and 65.3% with no acetabular osteolysis. Most cups showed a good clinical outcome in general, but major Acetabular Cup System liner failure and osteolysis were frequent. Patients with the ACS cups still in place should be monitored closely.

Aged↗

The Harris-Galante total hip arthroplasty: a minimum 8-year follow-up study.

A total of 93 Harris-Galante Porous I (HGP- I) prostheses were analyzed with a mean follow-up of 10.2 years. Thigh pain (28 hips) correlated with unstable fixation (P<.005), female gender (P<.045), young age (P<.05), poor distal femoral fill (P<.002), subsidence (P<.0001), and osteolysis (P<.05). Thirteen stems and 6 metallic shell cups were revised. Kaplan-Meier analysis showed 13-year survival rates of 92.5% +/- 5.8% for the metallic shell cup, 79.7% +/- 13% for the HGP-I cup, and 76.3% +/- 14.0% for the stem. Five polyethylene liners were changed because of wear >1 mm. Radiographic loosening occurred in 8 cups. Radiographic bone ingrowth was present in 54 stems, stable fibrous fixation was present in 24 stems, and unstable fixation was present in 15 stems. The mean polyethylene wear was 0.17 mm/y. Eleven hips (11.8%) had acetabular osteolysis, and 24 (25.8%) had femoral osteolysis, the latter being more frequent in unstable stems (P<.007). The HGP-I metallic cup shows better clinical and radiographic results than the stem, which frequently is associated with pain, unstable fixation, and osteolysis. Excessive polyethylene wear is frequent.

Arthroplasty, Replacement, Hip↗

Low-friction arthroplasty in patients younger than 40 years old: 20- to 25-year results.

A total of 67 low-friction arthroplasties were performed from 1971 through 1978 in patients <40 years old and followed an average of 21.7 years. There have been 33 cup loosenings and 17 stem loosenings. The average rate of wear of the cup was 0.12 mm/y for the entire series and 0.16 mm/y for the revised cups. Although the preoperative diagnosis leading to low-friction arthroplasty commonly reflected some deficiency in bone structure, particularly in the acetabulum, there were no primary osteoarthrosis cases. The femoral stem proved to be durable, but acetabular cups gave poorer results in younger patients than in older patients. The 2 major factors limiting the longevity of the cemented cup were acetabular bone quality and wear.

Adolescent↗

Loosening of the cup after low-friction arthroplasty in patients with acetabular protrusion. The importance of the position of the cup.

Between 1972 and 1990, we performed 168 primary low-friction arthroplasties in 125 patients with acetabular protrusion. Twelve hips were lost to follow-up within eight years and eight which became infected were excluded from the final study. Of the 148 hips remaining, 62 with a mild protrusion were classified as group 1, 54 with moderate or severe protrusion as group 2 and, after 1985, 32 with moderate and severe protrusion which required bone grafts as group 3. The mean follow-up was 18.3 years (3 to 24) for group 1, 17.4 years (8 to 22) for group 2 and ten years (8 to 13) for group 3. There were 31 revisions of the cup, 12 in group 1 and 19 in group 2. According to the Kaplan-Meier analysis the overall rates at 20 years were 21 +/-10.79% in group 1 and 37 +/- 11.90% in group 2. There have been 43 radiological loosenings: 22 in group 1, 21 in group 2 and none so far in group 3, at ten years. The overall loosening rates at 20 years were 42 +/-14.76% in group 1 and 49 +/- 19.50% in group 2. The grafts were well incorporated in all group-3 hips, and the bone structure appeared normal after one year. The distance between the centre of the head of the femoral prosthesis and the approximate true centre of the femoral head was less in group 3 than in groups 1 and 2 (p < 0.01). According to the Cox proportional-hazards regression this was the single most important factor in loosening of the cup (odds ratio 1.11; 95% CI 1.05 to 1.18/mm). Better results were obtained in moderate and severe protrusions reconstructed with bone grafting than in hips with mild protrusion which were not grafted.

Acetabulum↗

Porous-coated cementless acetabular cups in revision surgery: a 6- to 11-year follow-up study.

Between 1986 and 1991, 65 cementless hemispherical acetabular cups were implanted in 60 patients in revision surgery. Different designs were used, including PCA (29 cups), Duraloc (14 cups), Harris-Galante (12 cups), and Omnifit (10 cups). The mean age of patients was 54.7 years. The Paprosky types of the acetabular tone defects were type 1, 2 hips; type 2, 38 hips; type 3A, 15 hips; and type 3B, 10 hips. For unrevised hips, the mean follow-up was 8.3 years (range, 6-11 years). Bone allografts were used in 56 hips: Morcellized cancellous graft was used in 42 hips, structural graft for contained defects was used in 7 hips, and structural graft for uncontained defects was used in 7 hips. There were poor clinical results in 14 hips (22%). Re-revision was necessary in 7 hips (10.8%). There was definite radiographic loosening in 18 hips and possible loosening in 4 hips. Screw failure occurred in 6 hips, and a radiolucency in 1 or more DeLee-Charnley zones was apparent in 45 hips (69.2%). Moderate or severe graft resorption were found in 4 of the 42 morcellized grafts, in 6 of the 7 structural grafts for uncontained defects, and in all 7 of the 7 structural grafts for contained defects. The best results were obtained in hips with a bone defect of less than 30%. The use of a cementless acetabular cup supplemented with screws is contraindicated in hips with a bone defect greater than 50%. Hip reconstruction using structural bone-graft to stabilize the prosthesis gives the worst results.

Acetabulum↗

Femoral osteolysis after low-friction arthroplasty. A planimetric study and volumetric estimate.

Sixty-three cases of femoral osteolytic cavities were analyzed in a consecutive series of 680 low-friction arthroplasties of the hip performed in 598 patients between 1971 and 1979. Follow-up evaluation averaged 15 years 9 months (range, 2-22 years). The total cumulative probability of osteolysis developing after 20 years was 11% according to survivorship analysis. The mean time of appearance of the osteolytic lesion was 9 years 3 months after operation. Most of the cavities were seen in Gruen zones 3, 5, and 7 in decreasing order. Osteolytic cavities were classified as follows: group 1, cavities in cases with radiographic definite stem loosening (20 cases); group 2, cavities in cases with an acetabular wear equal to or greater than 2 mm (22 cases); and group 3, cavities in cases combining both of the above-mentioned findings (21 cases). Cementing defects such as voids and thin mantles were less frequent in group 2 than in groups 1 and 3 (P < .005). Poor clinical results were more frequent in groups 1 and 3 (P < .05), in all instances). Focal cavities were more frequent in group 2, and multifocal and diffuse cavities were more frequent in groups 1 and 3 (P < .05). The average planimetric area on radiographic diagnosis was 0.81 cm2, and the average approximate volume was 1.86 cm3, with significant differences among the three groups of cavities. Progression of the cavity area and volume was linear over time (P < .001) and more aggressive in groups 1 and 3 than in group 2 (P < .05). Thus, loosening of the stem was a more deciding factor than acetabular wear in the progression of cavities.

Adult↗

Mittelmeier ceramic-ceramic prosthesis after 10 years.

The clinical status of 83 Mittelmeier ceramic-ceramic (Mark II) cementless total hip prostheses (Autophor, Osteo AG, Selzach, Switzerland) implanted between 1978 and 1984 was analyzed. Retrieved tissue from the revised hips was studied histologically. The mean patient age was 47.5 years (range, 19-71 years). One or both components of 12 hips were revised (16% at 16 years in the survival study). Eleven acetabular components and seven stems were revised, with three of the sockets fractured. The mean follow-up period for the patients with unrevised hips was 12.3 years. Osseointegration was uncommon in both the cup and stem. Radiographic cup loosening was observed in 53% of hips at 16 years in the survival study, with most having a complete radiolucent line of 2 mm around the cup. Radiographic stem loosening appeared in 15% of hips at 16 years. Fibrous stable fixation was present in 64% of stems. Significant radiographic acetabular wear was not observed in any hip. The Mittelmeier Mark II prosthesis had worse long-term results than reported with cemented or other uncemented prostheses. Although there was no significant acetabular wear, intracellular ceramic wear debris was seen in the retrieved tissues.

Adult↗

The fixation of porous-coated femoral stems. A radiographic study of 113 cases with a 4 to 8 year follow up.

Changes occurring in the fixation of 113 porous-coated PCA uncemented femoral stems were studied in 90 patients who were operated on between 1984 and 1988. The average follow up was 5 years. Fixation was classified in radiographs as osteointegration, stable fibrous fixation or unstable. Four femoral components were revised. Metaphyseal osteoporosis was associated with those with a stem diameter greater than 13 mm. After 2 years, osteointegration was present in 73% and instability in 24% which was not related to the position of the stem. At the end of the follow up period, 20% of the stems showing osteointegration had changed and become unstable.

Adult↗

Long-term results of aseptic cemented Charnley revisions.

One hundred eighty low-friction arthroplasties of the hip in 164 patients in first-time revision surgery were operated between 1973 and 1985. This series used only cement fixation, and aseptic loosening and femoral stem fractures were the only indications for revision. The average follow-up period was 11.5 years. Intra-operative and postoperative complications were frequent: femoral shaft fracture (13 cases), femoral shaft perforation (12 cases), deep infection (14 cases), and dislocation (15 cases). Twenty-eight hips were rerevised or removed (resulting in a total cumulative probability of rerevision of 20% after 16 years, according to survivorship analysis). Nineteen cups were rerevised (13% after 16 years, according to survivorship analysis), and 24 femoral stems were rerevised (16% after 16 years, according to survivorship analysis). Radiographic cup and femoral loosening appeared in 29 and 36 cases, respectively (24 and 22% after 16 years, respectively, according to survivorship analysis). Good results were observed when there was a healthy and intact bone bed, whereas poor results were related to inadequate bone stock in the acetabulum and femur. Radiolucent lines were frequent in both components; radiolucent lines less than 2 mm wide were frequent in acetabular zone 1. Pistoning of the prosthesis and the cement within the bone and calcar pivot was the most frequent type of stem loosening.

Bone Cements↗

Fixation of cementless acetabular cups. A radiographic 4-8-year study of 102 porous-coated components.

We studied fixation changes over time in 113 porous-coated Howmedica (PCA) cementless acetabular cups inserted in 90 patients 1984-1988. The mean follow-up was 5 years. Radiographic fixation was classified as stable, fibrous-stable, or unstable. 9 cups, 3 in neutral position and 6 vertical, were revised. At follow-up, 40/75 neutral cups were stable versus 7/27 vertical cups. Most stable cups and two thirds of the unstable cups were clinically good. After the first 2 years, 28/75 neutral cups and 10/27 vertical cups changed their fixation; 12 had improved fixation and 26 had a worse one.

Acetabulum↗

Femoral shaft fractures after cemented total hip arthroplasty.

Thirty-seven femoral shaft fractures occurred in 2360 cemented hip arthroplasties carried out between 1971 and 1989 at varying intervals after operation (average 3.7 years). Three types of fracture were recognised and treatment depended on the type, as did the prognosis. Good results were obtained in 70% of the cases.

Adult↗

The femoral component in low-friction arthroplasty after ten years.

In 623 low-friction arthroplasties ten years after implantation, 70 hips (18.04% after 16 years) showed loosening of the femoral component. Eighty-four percent appeared within ten years. Fracture of the stem occurred in 4.3% of cases after 16 years, and resorption over 5 mm of the femoral neck occurred in 9.3%. Calcar cysts appeared in 2.9% and endosteal cavitations in 18.04% after 16 years; both findings were related to acetabular wear greater than 2 mm. Gruen's Type III (calcar pivot) was the least common loosening (6.8%) during the first ten years. After this time its incidence increased to 17.1%. Loosening of the femoral component was not related to age, weight, or activity. It was, however, associated with poor surgical technique, i.e., varus position (46%), cementation defects (34%), and/or femoral neck osteotomy on the lesser trochanter (36%).

Adolescent↗