PubMed Health⌕ Search

Biomedical subjects

E Gautier

Publications and source records attributed to E Gautier.

At least 19 recordsLinked to original sources

Trochanteric flip osteotomy for cranial extension and muscle protection in acetabular fracture fixation using a Kocher-Langenbeck approach.

OBJECTIVE: To describe the advantages and surgical technique of a trochanteric flip osteotomy in combination with a Kocher-Langenbeck approach for the treatment of selected acetabular fractures. DESIGN: Consecutive series, teaching hospital. METHODS: Through mobilization of the vastus lateralis muscle, a slice of the greater trochanter with the attached gluteus medius muscle can be flipped anteriorly. The gluteus minimus muscle can then be easily mobilized, giving free access to the posterosuperior and superior acetabular wall area. Damage to the abductor muscles by vigorous retraction can be avoided, potentially resulting in less ectopic ossification. Ten consecutive cases of acetabular fractures treated with this approach are reported. In eight cases, an anatomic reduction was achieved; in the remaining two cases with severe comminution, the reduction was within one to three millimeters. The trochanteric fragment was fixed with two 3.5-millimeter cortical screws. RESULTS: All osteotomies healed in anatomic position within six to eight weeks postoperatively. Abductor strength was symmetric in eight patients and mildly reduced in two patients. Heterotopic ossification was limited to Brooker classes 1 and 2 without functional impairment at an average follow-up of twenty months. No femoral head necrosis was observed. CONCLUSION: This technique allows better visualization, more accurate reduction, and easier fixation of cranial acetabular fragments. Cranial migration of the greater trochanter after fixation with two screws is unlikely to occur because of the distal pull of the vastus lateralis muscle, balancing the cranial pull of the gluteus medius muscle.

Acetabulum↗

Circulating cell-free fetal DNA in maternal serum appears to originate from cyto- and syncytio-trophoblastic cells. Case report.

Circulating cell-free fetal DNA in maternal serum offers an early and non-invasive method for prenatal diagnosis, but the origin of this DNA is still unknown. We report the absence of the SRY gene in maternal serum of a pregnant woman despite male genitalia at ultrasound. The karyotype was 45,X after direct trophoblast analysis and 45,X/46,Xidic(Yp) after culture and in all fetal tissues studied. Due to the absence of the SRY sequence in maternal blood and in the cytotrophoblast, we presume that free fetal DNA in this case originates from trophoblastic cells. As the case presented here is exceptional, it only has a minor impact on the accuracy of fetal sex determination by maternal serum analysis, but highlights the importance of and the necessity for the complementary ultrasonographic control.

DNA↗

The oxygen concentrator: an appropriate technology for treating hypoxaemic children in developing countries.

The World Health Organization (WHO) recommends supplying oxygen in developing countries by concentrators because cylinders pose considerable logistic and financial problems. This technology was employed to treat children in a hospital in Ndioum, Senegal, who met the WHO oxygenation criteria. There were clear clinical and financial benefits, but neither the nurses' knowledge of the various techniques of oxygen supply nor the maintenance service were satisfactory. The use of concentrators should be encouraged in developing countries. A strategy including technical training, maintenance and monitoring should be adopted. Corrective actions were undertaken in Ndioum, and several concentrators are now being used on a regular basis.

Child, Preschool↗

Ten-year patient and prosthesis survival after unipolar hip hemiarthroplasty in female patients over 70 years old.

We found that 162 unipolar hemiarthroplastics of the hip were performed between 1989 and 1995 on women over 70 years of age in our institution. The mean age was 84 years (70 to 99). Cumulative survival of the prostheses was 98% at 1 year and 94% after 5 and 10 years. Of the original patients, 137 have died. Survival rate for patients was 73% at 1 year, 23% at 5 years, and 6% at 10 years. Eighteen patients could be accounted for, with a mean follow-up time of 7.7 years (5.5-11.3 years). The mean Harris hip score was 80 points (55-100). Protrusion was observed in 3 patients. The treatment of cervical neck fracture with unipolar hip prostheses is a valuable method, with a low complication rate, particularly in women over 70 years for whom life expectancy may be short.

Aged↗

[Biological internal fixation -- guidelines for the rehabilitation].

The process of fracture healing restores the biological and mechanical state of the bone tissue. In contrast to other tissues, bone has the unique capacity to heal through a real repair process resulting not in a scar but in a regular reconstitution of its original tissue structure. During the last two decades, the understanding of bone biology continuously evolved leading to the new concept that preservation of the viability of the bone fragments is the key to unimpaired fracture healing. The biological fracture management provides environmental conditions that allow the natural healing process to occur as quickly and undisturbed as possible. In comminuted diaphyseal and metaphyseal fractures, the reduction process strives for restoration of proper length and axial and torsional alignment. Thereby, the reduction technique is mainly indirect, i.e. without direct visualization of the fracture area. The primary stability of an osteosynthesis seems to be of secondary importance for achieving sound bone healing. Stabilization can either be performed with an intramedullary nail or a bridging plate. The new biological plating technique imitates the concept of intramedullary fixation. It requires the use of a long implant working with improved leverage. This reduces both, the loading of the screws and the loading of the plate. The good healing capacity of viable fragments and their integration into the fracture callus protects the implant (especially a plate) from fatigue failure. To help to accomplish this new concept of biological plate fixation, new implants such as the Locking Compression Plate (LCP) have been introduced. The mechanical efficiency of this new plate generation is enhanced due to its possibility for angular stability screw insertion; load transfer by friction can be replaced by a load transfer by interlocking (internal fixator), reducing the biological interference of this implant (no contact implant). Functional rehabilitation with painfree mobilization needs to be performed carefully because the loading capacity of the biological plate osteosynthesis is low until radiological signs of bone healing via callus formation is visible. Clinical signs of overload and radiological indicators of potential mechanical failure of the fixation have to be identified by the general practitioners, and the compliance of the patient has to be controlled during the rehabilitation phase to avoid complications after biological internal fixation.

Bone Plates↗

[Relevance and advantages of new angular stable screw-plate systems for diaphyseal fractures (locking compression plate versus intramedullary nail].

Intramedullary nailing still remains the golden standard for the treatment of diaphyseal fractures of the long bones in adults. The operative technique is standardised and usually minimal invasive, the primary healing rate is high, and complications arise rarely. However, for problem zones (meta-diaphyseal region), in poor bone quality and in other relative contraindications for nailing (narrow medullary canal, fractures in adolescents and polytrauma) the new angular stable screw-plate-systems (LISS, LCP) offer an excellent alternative for the operative stabilisation. The high primary stability in combination with newly developed minimal-invasive techniques (MIPO = minimal invasive plate osteosynthesis) are the bases for a functional after treatment and a rapid bony consolidation with a low complication rate.

Adolescent↗

Recombinant adenovirus shedding after intratumoral gene transfer in lung cancer patients.

We conducted two phase 1 trials of direct intratumoral injection of a recombinant E1E3-deleted adenovirus (AdR) encoding either the bacterial enzyme beta-galactosidase (Ad.RSVbetagal) or interleukin 2 (IL2, AdTG5327) into primary nonsmall-cell lung cancers of 21 patients. We report here virus shedding and the duration of virus expression in the tumor after intrabronchial injection of 10(7), 10(8) or 10(9) PFU of adenovirus. The infectious AdR and the viral DNA were detected in PBL, plasma, stool and aerodigestive samples in a dose-dependent manner, since cell cultures and PCRs were found to be positive mainly for samples from patients who received the highest AdR dose (10(9) PFU). We detected beta-galactosidase activity in the tumor biopsy samples of 66% of the patients, seemingly dose related, and only low levels of IL2 mRNA could be detected in tumor biopsy samples. E1 sequences were not detected by PCR in any of the PBL and bronchial samples collected after virus delivery, except in one patient. In this patient, E1 sequences were detected in PBL as well as in tumor biopsy samples collected at days 8, 30 and 60 and were correlated with longer beta-galactosidase expression in tumor samples. PBL tested before and after virus delivery contained both E1 sequences indicating that they did not result from replication-competent adenovirus (RCA) E1 sequences present in the inoculum. In addition, only on the day of the injection was Ad.RSVbetagal also detected in E1-positive PBL, indicating that virus replication in blood was very unlikely.

Adenoviridae↗

The relationship between cup design and the radiological signs of aseptic loosening in total hip arthroplasty.

We assessed differences in the incidence and appearance of the radiological signs of loosening of the cup for various types of design. This was an observational study based on hip registry data of 15,340 patients with 17,951 total hip arthroplasties collected over a period of 33 years in 49 hospitals in Central Europe. The threaded and the press-fit titanium cups showed significantly less aseptic loosening than the other systems. The direction of migration and the frequency of the radiological signs of loosening differed between the cup systems and were time-dependent. Our findings indicate the superiority of uncemented threaded cups and press-fit titanium cups over other designs of cup.

Acetabulum↗

[First trimester fetal sex determination in maternal serum using real-time PCR].

OBJECTIVE: Fetal sex prediction can be achieved using PCR targeted at the SRY gene by analyzing cell-free fetal DNA in maternal serum. Unfortunately, the results reported to date, show lack of sensitivity, especially in the first trimester of pregnancy. Therefore, determination of fetal sex by maternal serum analysis can not replace caryotype analysis following chorionic villus sampling. PATIENTS AND METHODS: A new highly sensitive real-time PCR was developed to detect a SRY gene sequence in maternal serum. Analysis was performed on 121 pregnant women during their first trimester of pregnancy (mean gestational age: 11.8 weeks). Among them, 61 had at least one previous male-bearing pregnancy. Results were compared to fetal sex. RESULTS: SRY PCR analysis of maternal serum was in complete concordance with fetal sex. Among the 121 pregnant women, 61 were bearing a male fetus and 60 a female fetus No false negative results were observed. Furthermore, no false positive results results occurred although 27 women carried female fetus during the current pregnancy, had at least one previous male-bearing pregnancy. DISCUSSION AND CONCLUSION: This study demonstrates that a reliable, non-invasive sex determination can be achieved by PCR analysis of maternal serum during the first trimester of pregnancy. This non-invasive approach for fetal sex prediction should have great implications in the management of pregnant women carriers of an X-linked genetic disorder. Prenatal diagnosis is thus performed for male fetuses only, avoiding invasive procedures and the risk of fetal loss for female fetuses.

DNA↗

Treatment of cartilage defects of the talus by autologous osteochondral grafts.

We reviewed retrospectively 11 patients who had been treated surgically by open autologous osteochondral grafting for symptomatic chondral or osteochondral defects of the dome of the talus between 1996 and 1999. The mean ages of the eight men and three women were 34.2 and 25.9 years, respectively, with a mean time to follow-up of 24 months. The results of functional outcome were prospectively obtained using the MODEMS AAOS foot and ankle follow-up questionnaire, the AOFAS ankle-hindfoot scale and the Hannover scores for the ankle. The grafts were harvested from the ipsilateral knee. Good to excellent results were obtained for the ankle without adverse effects on the knee. We believe that autologous osteochondral grafting should be considered for the patient with a symptomatic osteochondral defect of the talus.

Adolescent↗

Cardiovascular effects of SL65.0472, a 5-HT receptor antagonist.

In this study, we describe the cardiovascular effects of SL65.0472 (7-fluoro-2-oxo-4-[2-[4-(thieno[3,2-c] pyridin-4-yl) piperazin-l-yl] ethyl]-1, 2-dihydroquinoline-1-acetamide), a novel 5-hydroxytryptamine (5-HT) receptor antagonist developed for the treatment of cardiovascular disease, in several in vivo models. The haemodynamic profile of SL65.0472 was evaluated in anaesthetised dogs. Following i.v. bolus doses of 0.03 mg/kg i.v. and 0.3 mg/kg, no significant changes in cardiac output, contractility or rate, systemic and pulmonary pressures, regional blood flows and vascular resistances or electrocardiogram were noted. After 1 mg/kg i.v. SL65.0472 significantly reduced arterial blood pressure. In conscious spontaneously hypertensive rats administration of SL65.0472 0.5 mg/kg p.o. had no effect on mean arterial blood pressure or heart rate. Vasoconstriction produced by 5-HT results primarily from the stimulation of two receptor subtypes, 5-HT(1B) and 5-HT(2A) receptors. In anaesthetised dogs SL65.0472 antagonised sumatriptan-induced decreases in saphenous vein diameter (5-HT(1B)-receptor mediated) with an ID(50) of 10.1 microg/kg i.v. (95% c.l. 8.3-12.4). In anaesthetised pithed rats SL65.0472 inhibited 5-HT pressor responses (5HT(2A)-receptor mediated) with ID(50) values of 1.38 microg/kg i.v. (95% c.l. 1.15-1.64) and 31.1 microg/kg p.o. (95% c.l. 22.6-42.6). The duration of the 5-HT(2A)-receptor antagonist effect of SL65.0472 following oral administration was evaluated in conscious rats. SL65.0472 (0.1 mg/kg p.o.) markedly inhibited 5-HT pressor responses 1 and 6 h after administration. Therefore, in vivo, SL65.0472 potently antagonises vasoconstriction mediated by 5-HT(1B) and 5-HT(2A) receptors but has minimal direct haemodynamic effects.

Animals↗

Prenatal diagnosis of congenital toxoplasmosis by duplex real-time PCR using fluorescence resonance energy transfer hybridization probes.

The diagnosis of congenital toxoplasmosis frequently relies on PCR tests of amniotic fluid (AF). A duplex real-time quantitative PCR test based on fluorescence resonance energy transfer was developed to quantify the parasite load and to decrease the risk of contamination. An internal control based on the detection of 10 pg mouse DNA added to the AF was included to check for PCR efficiency. The relationship between the parasite load and the occurrence of ultrasonographic abnormalities in 87 samples of AF was analyzed. Seven AF (8%) had a parasitic load > 10(3); 14 (16%) had > 10(2)-< or =10(3); 26 (30%) had > 10-< or = 10(2); and 40 (46%) had < or = 10 parasites/ml. Four of the six AF with cerebral ventriculomegaly had >10(3) parasites/ml. The other two had 130 and 24 parasites/ml, respectively. No parasitic loads of > 10(3) parasites/ml and no ultrasonographic abnormalities were observed in the 11 AF with maternal toxoplasmosis in the third trimester. Therefore, there is a trend to associate high parasite count with ultrasonographic abnormality, but the main concern remains early maternal infection. The importance of quantification should be better evaluated with postnatal studies. The duplex LightCycler PCR test currently provides rapid and safe results.

Amniocentesis↗

First-trimester fetal sex determination in maternal serum using real-time PCR.

Fetal sex prediction can be achieved using PCR targeted at the SRY gene by analysing cell-free fetal DNA in maternal serum. Unfortunately, the results reported to date show a lack of sensitivity, especially during the first trimester of pregnancy. Therefore, determination of fetal sex by maternal serum analysis could not replace karyotype analysis following chorionic villus sampling. A new highly sensitive real-time PCR was developed to detect an SRY gene sequence in maternal serum. Analysis was performed on 121 pregnant women during the first trimester of pregnancy (mean gestational age: 11.8 weeks). Among them, 51 had at least one previous male-bearing pregnancy. Results were compared with fetal sex. SRY PCR analysis of maternal serum was in complete concordance with fetal sex. Among the 121 pregnant women, 61 were bearing a male fetus and 60 a female fetus. No false-negative results were observed. Furthermore, no false-positive results occurred, even though 27 women carrying a female fetus during the current pregnancy had at least one previous male-bearing pregnancy. This study demonstrates that a reliable, non-invasive sex determination can be achieved by PCR analysis of maternal serum during the first trimester of pregnancy. This non-invasive approach for fetal sex prediction should have great implications in the management of pregnant women who are carriers of an X-linked genetic disorder. Prenatal diagnosis might thus be performed for male fetuses only, avoiding invasive procedures and the risk of the loss of female fetuses.

DNA↗

Low reoperation rate with the Medoff sliding plate: 1 technical failure in 63 trochanteric hip fractures.

The Medoff sliding plate was designed to treat unstable intertrochanteric and subtrochanteric fractures. This plate has a dual sliding capability along both the femoral shaft and neck in order to improve bone coaptation, interfragment compression and hence load-sharing between bone and implant in hip fractures. In a retrospective study of 63 patients (mean age 82 (51-98) years) with intertrochanteric (n 44) and high subtrochanteric fractures (n 19), we assessed the results with the Medoff sliding plate. All patients, except 1 lost to follow-up, were examined clinically and radiographically. 14 patients died within 1 year, and in the other, the mean follow-up was 15 (6-30) months. 1 technical failure occurred, leading to a single reoperation. The low technical failure rate suggests that the Medoff sliding plate with combined compression modus is suitable for treating intertrochanteric and high subtrochanteric fractures.

Aged↗

Accuracy of computer-guided screw fixation of the sacroiliac joint.

Computer-assisted image guidance allows precise preoperative planning and intraoperative localization of surgical instruments. The technique recently was validated for the insertion of pedicle screws. In the laboratory, the precision of a surface-matching algorithm was evaluated for registration and accuracy and safety of screw placement into the vertebral bodies of S1 and S2 for fixation of the sacroiliac joint. Using six plastic pelves, 24 screw holes were made through the sacroiliac joint into the vertebral body of S1, and 12 holes were made through the sacroiliac joint into S2. The accuracy of the hole position was evaluated using a postoperative computed tomography examination. The safety factor was assessed by analysis of the remaining bone stock around the holes calculating a theoretical cylindrical volume being outside bone with increasing bore hole diameters. The registration was accurate with a mean error less than 1.4 mm in the posterior parts of the pelvis. The drilling followed precisely the preoperatively planned trajectories; perforation of the cortex of the sacrum was not observed. The safety factor of the S1 vertebral body is higher than that of S2 allowing larger diameter screw insertion into S1. This technique provides a safe and precise guide for transcutaneous or open insertion of iliosacral screws in cases of iliosacral dislocation or sacral fracture.

Algorithms↗

Surgical dislocation of the adult hip a technique with full access to the femoral head and acetabulum without the risk of avascular necrosis.

Surgical dislocation of the hip is rarely undertaken. The potential danger to the vascularity of the femoral head has been emphasised, but there is little information as to how this danger can be avoided. We describe a technique for operative dislocation of the hip, based on detailed anatomical studies of the blood supply. It combines aspects of approaches which have been reported previously and consists of an anterior dislocation through a posterior approach with a 'trochanteric flip' osteotomy. The external rotator muscles are not divided and the medial femoral circumflex artery is protected by the intact obturator externus. We report our experience using this approach in 213 hips over a period of seven years and include 19 patients who underwent simultaneous intertrochanteric osteotomy. The perfusion of the femoral head was verified intraoperatively and, to date, none has subsequently developed avascular necrosis. There is little morbidity associated with the technique and it allows the treatment of a variety of conditions, which may not respond well to other methods including arthroscopy. Surgical dislocation gives new insight into the pathogenesis of some hip disorders and the possibility of preserving the hip with techniques such as transplantation of cartilage.

Adolescent↗